Description
Motion Manager is a distracted driving solution that limits the functionality of mobile computers while the vehicle is moving. Motion Manager helps to prevent distracted driving to:
comply with legislation and corporate safety policies
reduce risk
minimize organization liability
provide a safer workplace
Motion Manager is a microcontroller-based peripheral that incorporates sensor technology to detect vehicle motion. When connected, via a USB port, to a Microsoft Windows computer with Motion Manager software Motion Manager system can be set-up to blank the display when the sensed vehicle motion is above the configured threshold.
The Motion Manager system consists of:
Sensor hardware
Detects vehicle motion
USB A to Mini B cable
Connects the Sensor Hardware to the computer / docking station
Proprietary Software
Resides on the Windows computer
Communicates with the Sensor Hardware
Mini USB Port
Rugged Aluminum Case
LED Status Indicator Light
Mounting Plate
with holes (x2)
Dimensions
1.20” x 1.00” x 0.50 excluding mounting plate
2.10” x 1.00” x 0.50 including mounting plate
Mounting Manager Hardware Sensor
Parts and Layout
Motion Manager Features Overview
Basic function
Detects vehicle motion and blanks screen
Product Description
Microcontroller
-based peripheral with integrated motion
sensor, USB cable
System requirements
Operating system: MS Windows XP (SP3), Vista, 7 , 8 or 10
USB port
Data Logging
Administrator configurable:
Exports to CSV file
Mounting
Compact, robust aluminum case with mounting holes
Usage / working
environment
Unit
can be configured based on variety of driving
situations; has fast screen refresh
Key Features
In Motion Options
Blank display
Viewable display with disabled user inputs (note: user must
have administrator rights)
Screen Activation Options
User interaction: Prevents screen from becoming active when stopped temporarily
Screen automatically refreshes on stop after set time threshold
Undocked
Computer Options
Computer functions as normal
Blanks display
Operation
Once the administrator completes the installation and configurations the operation of Motion Manager requires no user interaction for start up.
The Motion Manager Sensor Hardware can remain connected to a USB port on the dock at all times or it can be connected when required.
The Motion Manager Sensor Hardware will start automatically as soon as it becomes receives power.
When properly installed in the Start-up menu of the computer, the Motion Manager software will automatically start when the computer is started.
When the software detects the hardware a connection is automatically established and the Motion Manager system will function.
The Motion Manager Sensor Hardware is equipped with a LED status indicator light:
Blinking green: Motion sensed is below the configured threshold
Blinking red: Motion sensed is above the configured threshold
Installation
1) Software
Sign on to the computer under a user with Administrator credentials.
Locate the exe file “BlackWhiteController1vXXX.exe” provided by PMT
or your equipment provider (possibly in a zip file that will need to be extracted before proceeding.
In the Program Files (x86) folder
Create a “PMT” folder and in that folder create a “BWC” folder
Place the exe file in the “BWC” folder
Place a shortcut to the exe file into the Startup folder of the Windows
Start menu.
Under Win7
Click on the Start button
Right-click on the All Programs item and select “Open All
Users”
Double-click on the Programs Folder
Double-click on the Start up Folder
Place a shortcut to the application in the Start-up folder
Give the program the ability to run as an administrator for
all users by right clicking on the shortcut and using Properties -> Compatibility -> Change settings for all users
Under Windows XP the procedure is similar
Under Windows 8 and 10 locate the user Startup folder and
place a shortcut to the exe file
Installation
2) Drivers
In order for Motion Manager to communicate with the computer you will need a driver for the UART communication port to the Motion Manager Sensor Hardware.
In most cases the computer will automatically download the driver.
Ensure that the computer has Internet connectivity before connecting
the Motion Manager Sensor Hardware
Connect the Motion Manager Sensor Hardware
Plug the Motion Manager Sensor Hardware into a USB port on
the computer OR dock the computer in a dock equipped with the Motion Manager Sensor Hardware
After the driver has finished loading, restart the computer. This will properly start the PMT Motion Manager Controller.
If your computer doesn’t download the driver automatically, the driver
is also provided by PMT in 32 bit and 64 bit or it can be manually downloaded at http://www.ftdichip.com/Drivers/VCP.htm
Installation
3) Sensor Hardware
Note: If you have purchased a PMT vehicle dock that has been integrated with Motion Manager then skip this step.
Select a position on the vehicle that will allow the Motion Manager
Sensor Hardware to sense motion of the vehicle. Positions where the
Motion Manager will sense movement of the operator should be avoided.
The Motion Manager Sensor Hardware may be screwed down or fixed
into position with industrial strength double sided tape or Velcro. For best results ensure that the Motion Manager Sensor Hardware is not mounted to anything that will absorb vibrations . A good solid mount to something connected to the chassis is recommended.
The orientation of the Motion Manager Sensor Hardware is not
important. Orient the Motion Manager Sensor Hardware to make cable placement efficient.
Connect the sensor to one of the dock’s USB Ports.
4) Configuration
When first installed, you will need to configure the sensor through the
Motion Manager software. Complete configuration instructions are included with this User Guide
After applying the completed configuration, close the configuration
window and minimize the status window. The system will save the settings to a file on that computer. Each time the system starts it will recall the last saved configuration.
If you change computers you will have to install the software and set
the configurations again.
Configuration
Open the System Tray and double click on the PMT icon.
Double clicking the PMT icon will open the status window.
The status window will show one of the following
Vehicle Stopped
Vehicle Moving
Waiting to search
Hunting
Configuring
Click the advanced button and enter the password “MMAdmin14”
Click OK
Current detected motion
Current motion threshold
Configuration Continued
This will open the PMT Motion Manager Settings window
As a starting point, set values to match those shown above
Note: Communications Port value can be different based on the
system that Motion Manager is connected to.
Configuration Tab Definitions & Settings
Communications: Port
The Motion Manager software is programmed to automatically
detect the USB port in use with the Motion Manager Sensor Hardware. User setting is usually not required.
USB serial port can be located using the device manager. It will be the last entry in the Ports (Com & LPT) list.
Each time the computer starts up it will search for the device and
download the last configuration when found. (Note: On the first start-up after the controller software is installed it will download the default configuration)
Communications: Status Rate
The time between communications from the sensor to the
computer. The sensor collects data at 400Hz and processes it to determine the motion status, but only updates the motion status to the computer as often as set by the status rate setting.
The units for the number in this field is X*10 milliseconds
1 equals 10 milliseconds equals 1/10 second
50 equals 500 milliseconds equals ½ second
100 equals 1000 milliseconds equals 1 second
Setting the update rate to a long period will increase the time
required for the screen to turn on after a stop as it waits for the sensor to send the current status. With a long setting it is
possible to miss a very short stop which is very desirable. (Note:
The duration settings are also designed to limit false starts and stops)
Communications: Speed
User setting not required.
Leave at 38400
Configuration Tab Definitions & Settings
Detection Parameters: Motion Threshold
The amount of sensor movement that is considered to be vehicle
motion.
Higher values require more vehicle motion to trigger the screen shut down.
Detection Parameters: Exp Period
The amount of smoothing of the sensor signal. Higher values
create a smoother signal.
For most applications we recommend 7 for this value. (smoothing over ~1/3 sec)
Detection Parameters: Trigger Duration & Clear Duration
Trigger and clear duration settings are used to limit false signals
by requiring a number of samples to be above or below the threshold value.
The Trigger Duration value sets the number of data samples required to be above the threshold before blanking the display.
The Clear Duration value sets the number of data samples required to be below threshold before turning on the display.
Detection Parameters: Scale Factors
User setting not required.
Leave at 256
Configuration Tab Definitions & Settings
Actions: On Motion
Sets what happens once motion threshold is exceeded
Options are:
No action
Nothing happens and computer functions are
normal
Blank Display
Screen goes blank (black)
Block Input
Display remains viewable and user input is disabled
Actions: No Sensor
Sets what happens when the sensor hardware is not detected
(sensor unplugged or computer undocked)
Options are:
No action
Nothing happens and computer functions are
normal
Blank Display
Screen goes blank (black)
Actions: Restore screen when stopped
When this box is checked the screen will automatically reactivate
from blank (black) once the vehicle is stopped (recommended for
forklift applications)
When this box is unchecked the user has to manually reactivate the screen by pressing a key on the keyboard, touching a touch screen or touching a touch pad (recommended for automobile applications)
Actions: Test “On Motion” Option
By pressing this button the system will simulate exceeding the
motion threshold and display the configured actions
Configuration Tab Definitions & Settings
PMT Banner
Use this option to display and position a banner that reads
“PMT Motion Manager Active”
The banner will help to inform the user that the Motion Manager
is active and is particularly useful when the action is set to Block Input
Change Password
Change password from default
Apply
When making changes to the settings always press Apply before
Close
Status Tab Definitions & Settings
Section 1 shows transmitted data status and the firmware version.
Section 2 shows the active configuration settings
Section 3 shows the actual data being measured by the sensor
Section 4 check box sends measurement data to the log page
1
2
3
4
Log Tab Definitions & Settings
By default this tab shows a running log of actions and status
To add data to the log
Check the “Enable logging of status packets” box on the Status tab
The log automatically starts when the computer starts and is erased when
the computer is powered down.
The Log to File function allows the log to be automatically saved to a file making the data available for future review
This function can be used to determine if and when the Motion Manager has been disconnected from the computer
Browse to set the file location and check the “Enabled” box
The data file can be saved to a local file or mapped network file
Loading...