Configuration Tab Definitions & Settings
• Communications: Port
• The Motion Manager software is programmed to automatically
detect the USB port in use with the Motion Manager Sensor
Hardware. User setting is usually not required.
• USB serial port can be located using the device manager. It will
be the last entry in the Ports (Com & LPT) list.
• Each time the computer starts up it will search for the device and
download the last configuration when found. (Note: On the first
start-up after the controller software is installed it will download
the default configuration)
• Communications: Status Rate
• The time between communications from the sensor to the
computer. The sensor collects data at 400Hz and processes it to
determine the motion status, but only updates the motion
status to the computer as often as set by the status rate setting.
• The units for the number in this field is X*10 milliseconds
• 1 equals 10 milliseconds equals 1/10 second
• 50 equals 500 milliseconds equals ½ second
• 100 equals 1000 milliseconds equals 1 second
• Setting the update rate to a long period will increase the time
required for the screen to turn on after a stop as it waits for the
sensor to send the current status. With a long setting it is
possible to miss a very short stop which is very desirable. (Note:
The duration settings are also designed to limit false starts and
stops)
• Communications: Speed
• User setting not required.
• Leave at 38400