2LEM-AURA WITH CT - CT DESIGNATES THAT THE LED LIGHT
OUTPUT CAN BE COLOR TUNED ACCOMPLISHING A COUPLE
DIFFERENT DESIRED OUTCOMES.
1. THE WHITE LIGHT OUTPUT CAN BE ADJUSTED IN COLOR
TEMPERATURE FROM WARM TEMPERATURES OF 1650K UP TO
COOL TEMPERATURES OF 4000 K.
2. COLOR SATURATIONS CAN BE ALTERED CHANGING THE
LIGHT OUTPUT FROM "WH ITE" TO ANY COLOR OF THE
SPECTRUM.
FIXTURES MAY BE PROGRAMMED WITH UP TO 5 PRESET SCENES
WHICH CAN BE RECALLED VIA SIMPLE 0-10V CONTROLS (BY
OTHERS).
WITH PROPER DMX CONTROL SYSTEMS (BY OTHERS) IT IS
POSSIBLE TO SET FIXTURES WITH CT TO CONSTANTLY COLOR
CHANGE THRU THE RANGE OF COLORS FOR DYNAMIC
ACCENT LIGHTING.
SEE WIRING DIAGRAMS ON FOLLOWING PAGES FOR VARIOUS
SETUP AND CONTROL OPTIONS.
(1200 Lumen)
20
(2000 Lumen)
T
T-Grid
F
Flanged
L
Flangeless
G
Slotted
T-Grid
P
Pendant
24" standard
S
Surface
Clarus 2LEM-AURA series offers all the benefits of
accent adjustable MR16
's with LED technology.
Clarus AURA series fixtures powered by Lumenetix
araya5 tunable LED technology featuring a wide
range of color and dimming options.
20, 40 and 60° beam spreads
Heads that rotate 190° and tilt up to 45° either
side
Versatile lamping and mounting configurations
Up to 1200lm output, 90+ CRI standard.
Factory wired for ease of installation
LED Drivers accessible from below the ceiling on
recessed version
Chicago Plenum - CCEA - Consult Factory
Fixtures are ETL/cETL listed for damp locations and
have standard electronic drivers
Each fixture is tested at the factory before
shipment.
CLARUS SERIES LED FIXTURES CARRY A 5 YEAR
LIMITED WARRANTY.
20
20° BEAM
40
40° BEAM
60
60° BEAM
1
C
(Commission ing
1
Tool Setup)
Single
2
2 Circuit
3
3 Circuit
4
4 Circuit
SOME OPTIONS MAY NOT BE AVAILABLE IN COMBINATIONS - ALL
FIXTURE COFIGURATIONS SUBJECT TO FINAL FACTORY APPROVAL
I
(iOS App Setup
via Bluetooth)
CX
(Commission ing
Tool Setup
with DMX
capabilities)
IX
(iOS App Setup
via Bluetooth
with DMX
capabilities)
CE
(Commission ing
Tool Setup
with Lutron
EcoSystem
capabilities)
IE
(iOS App Setup
via Bluetooth
with Lutron
EcoSystem
capabilities)
120*
277*
347**
step down transformer -
CONSULT FACTORY
*Voltage must be
specified for recessed
L
Linear
2
S
3
Square
4
** 347v uses a
versions
NONE
GLR Fuse
B
Black
W
White
S
Silver
Z
Bronze
C
Custom
MOUNTING OPTIONS
F - FLANGED
L - FLANGELESS
T - T GRID
G - SLOT GRID
G
100 GILBANE STREET - WARWICK, RI - 02888
TEL: (401)738-7266 FAX: (401)738-0618
www.PMCLIGHTING.com
S - SURFACE
CONSULT FACTORY OR VISIT OUR WEBSITE FOR SPECIFIC INSTALLATION INSTRUCTIONS
Specifications and Dimensions are subject to change without notice.
P - PENDANT
2LEM-AURA - 000
INSTALLATION / WIRING
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING LUMINAIRE.
This luminaire is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before installation.
To prevent electric shock, turn off electricity at main power supply before proceeding. Retain these instructions for maintenance reference.
4LE-AURA SERIES FIXTURE MUST BE INSTALLED IN AMBIENT TEMPERATURE ENVIRONMENTS NOT EXCEEDING 50°C TO AVOID POSSIBLE DAMAGE TO THE LED
MODULE FROM OVERHEATING. 6LE-AURA SERIES LUMINAIRES INCORPORATE LED MODULES WITH ON-BOARD THERMAL PROTECTION WHICH REDUCES
CURRENT TO THE LED WHEN THE MAXIMUM TEMPERATURE IS EXCEDED PREVENTING OVERHEATING BY SLIGHTLY DIMMING THE LED MODULE.
ELECTRICAL CONNECTIONS TO BE MADE IN ACCORDANCE WITH ALL APPLIC ABLE LOCAL AND NATIONAL CODES
CONNECT GROUND TO GREEN OR BARE COPPER FIXTURE WIRE (DEPENDING ON MODEL)
DISCONNECT ALL POWER TO FIXTURE BEFORE MAKING OR CHANGING ANY CONTROL WIRE CONNECTIONS
CONNECT SUPPLY HOT TO BLACK FIXTURE WIRE
CONNECT SUPPLY COMMON TO WHITE FIXTURE WIRE
4LE-AURA-CT with "C" Setup / Control Option
WIRELESS OPERATION USING THE COMMISSIONING TOOL (LCT)
FOR COMPLETE WIRELESS OPERATION USING
THE LCT COMMISSIONING TOOL TO
CONTROL DIMMING, CCT, COLOR HUE AND
COLOR SATURATION:
THE PURPLE AND GREY CONTROL WIRES MUST
BE CONNECTED TO EACH OTHER
THE BLUE AND WHITE CONTROL WIRES MUST BE
CONNECTED TO EACH OTHER
NOTE: FOR COMMISSIONING TOOL (LCT) SETUP
AND OPERATION FIXTURES MUST BE ORDERED
AS "C" TO BE ABLE TO COMMUNICATE WITH THE
LCT. "I" FIXTURES DO NOT HAVE LCT
COMMUNICATION CAPABILITIES.
4LE-AURA-CT with "I" Setup / Control Option
WIRELESS OPERATION USING iOS APP FOR iPHONE or iPAD
FOR COMPLETE WIRELESS OPERATION USING
THE iOS APP FOR iPHONE OR iPAD TO
CONTROL DIMMING, CCT, COLOR HUE AND
COLOR SATURATION:
NO CONTROL WIRES ARE ATTACHED TO THE
LED MODULE
NOTE: FOR iOS APP SETUP AND OPERATION
FIXTURES MUST BE ORDERED AS "I" TO INCLUDE
BLUETOOTH COMMUNICATION. "C" FIXTURES
DO NOT HAVE BLUETOOTH CAPABILITIES.
100 GILBANE STREET - WARWICK, RI - 02886
TEL: (401)738-7266 FAX: (401)738-0618
www.PMCLIGHTING.com
Specifications and Dimensions are subject to change without notice.
CONSULT FACTORY OR VISIT OUR WEBSITE FOR SPECIFIC INSTALLATION INSTRUCTIONS
2LEM-AURA - 000
INSTALLATION / WIRING
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING LUMINAIRE.
This luminaire is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before installation.
To prevent electric shock, turn off electricity at main power supply before proceeding. Retain these instructions for maintenance reference.
4LE-AURA-CT with "C" or "I" Setup / Control Option
0-10v DIMMER HARD WIRED CONTROL OF CCT AND DIMMING
WIRELESS CONTROL OF COLOR HUE AND SATURATION USING THE COMMISSIONING TOOL (LCT) or iOS APP
FOR HARD WIRED CONTROL USING 0-10V DIMMING DEVICES TO
CONTROL CCT AND DIMMING:
Connect a standard 0-10v Dimming Switch control device to the Blue and
White wires on the LED Module control wire assembly. The Dimming
Switch will control the CCT over the full tunable range of the module.
Connect a standard 0-10v Dimming Switch control device to the Purple
and Grey wires on the LED Module control wire assembly. The Dimming
Switch will control the Dimming over the full dimming range of the module.
Minimum dimming level is 1%.
Color Hue and Saturation are controlled wirelessly by the LCT
Commissioning Tool.
For non-dimming applications connect Purple and Grey wires on the LED
Module together and use the LCT Commissioning Tool set the desired
light output level. Fixture will retain this output level.
DO NOT USE THE ON-OFF SWITCHING OF THE DIMMER USED FOR
CCT CONTROL TO POWER THE FIXTURES. FIXTURES MAY BE
POWERED ON AND OFF FROM THE DIMMER USED FOR DIMMING.
4LE-AURA-CT with "C" or "I" Setup / Control Option
0-10v DIMMER HARD WIRED CONTROL OF DIMMING
WIRELESS CONTROL OF CCT, COLOR HUE AND SATURATION USING THE COMMISSIONING TOOL (LCT) or iOS APP
FOR HARD WIRED CONTROL USING 0-10V DIMMING DEVICES TO
CONTROL DIMMING:
Connect the Blue and White wires on the LED Module control wire
assembly together.
Connect a standard 0-10v Dimming Switch control device to the Purple
and Grey wires on the LED Module control wire assembly. The Dimming
Switch will control the Dimming over the full dimming range of the module.
Minimum dimming level is 1%.
CCT, Color Hue and Saturation are controlled wirelessly by the LCT
Commissioning Tool.
For non-dimming applications connect Purple and Grey wires on the LED
Module together and use the LCT Commissioning Tool set the desired
light output level. Fixture will retain this output level.
FIXTURES MAY BE POWERED ON AND OFF FROM THE DIMMER
USED FOR DIMMING.
100 GILBANE STREET - WARWICK, RI - 02886
TEL: (401)738-7266 FAX: (401)738-0618
www.PMCLIGHTING.com
CONSULT FACTORY OR VISIT OUR WEBSITE FOR SPECIFIC INSTALLATION INSTRUCTIONS
Specifications and Dimensions are subject to change without notice.
2LEM-AURA - 000
INSTALLATION / WIRING
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING LUMINAIRE.
This luminaire is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before installation.
To prevent electric shock, turn off electricity at main power supply before proceeding. Retain these instructions for maintenance reference.
4LE-AURA-CT with "C" or "I" Setup / Control Option
0-10v DIMMER HARD WIRED CONTROL OF SCENE SET SETTING - NO SECONDARY DIMMING
FOR SCENE SET HARD WIRING USING 0-10V DIMMING DEVICE
Aura Fixtures are capable of storing 5 different preset output modes called
scenes - each mode being a combination of dimming level, color saturation,
color hue and color temperature. These levels are set wirelessly via the LCT or
using the iOS APP via a Bluetooth connection from an iOS Smartphone or iPad,
and are stored in the fixture LED module.
Once programmed - the "scene" can be recalled by use of a standard 0-10v wall
dimmer switch. The 0-10v wall dimmer switch is wired to the BLUE and WHITE
wires fron the LED Module. The slide range is recognized by the LED module as
being divided into 5 different zones corresponding to the 5 different preset
scenes. While the slide is on zone 1, the module reacts as programmed for
scene 1, and so on. To change from scene 1 to scene 2, slide the dimmer
control until the scene changes.
When no dimming is to be used, the LED Module purple and grey wires are tied
together.
DO NOT USE THE ON-OFF SWITCHING OF THE SCENE SET DIMMER TO
POWER THE FIXTURES.
4LE-AURA-CT with "C" or "I" Setup / Control Option
0-10v DIMMER HARD WIRED CONTROL OF SCENE SET SETTING AND SECONDARY PROPORTIONAL DIMMING
FOR SCENE SET HARD WIRING USING 0-10V DIMMING DEVICE
Aura Fixtures are capable of storing 5 different preset output modes called
scenes - each mode being a combination of dimming level, color saturation,
color hue and color temperature. These levels are set wirelessly via the LCT or
using the iOS APP via a Bluetooth connection from an iOS Smartphone or iPad,
and are stored in the fixture LED module.
Once programmed - the "scene" can be recalled by use of a standard 0-10v wall
dimmer switch. The 0-10v wall dimmer switch is wired to the BLUE and WHITE
wires fron the LED Module. The slide range is recognized by the LED module as
being divided into 5 different zones corresponding to the 5 different preset
scenes. While the slide is on zone 1, the module reacts as programmed for
scene 1, and so on. To change from scene 1 to scene 2, slide the dimmer
control until the scene changes.
When dimming is to be used, the LED module purple and grey wires are tied to a
second 0-10v wall dimmer switch. DIMMING IS PROPORTIONAL TO THE
DIMMING LEVEL SET FOR EACH SCENE. At 100% on the dimming control
the brightness is as set for the particular scene chosen. The dimmer control
dims the light output down from that preset level. Minimum dimming level is 1%.
DO NOT USE THE ON-OFF SWITCHING OF THE SCENE SET DIMMER TO
POWER THE FIXTURES. FIXTURES MAY BE POWERED ON AND OFF
FROM THE DIMMER USED FOR DIMMING.
100 GILBANE STREET - WARWICK, RI - 02886
TEL: (401)738-7266 FAX: (401)738-0618
www.PMCLIGHTING.com
CONSULT FACTORY OR VISIT OUR WEBSITE FOR SPECIFIC INSTALLATION INSTRUCTIONS
Specifications and Dimensions are subject to change without notice.
2LEM-AURA - 000
INSTALLATION / WIRING
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING LUMINAIRE.
This luminaire is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before installation.
To prevent electric shock, turn off electricity at main power supply before proceeding. Retain these instructions for maintenance reference.
4LE-AURA-CT with "CX" Setup / Control Option
COMMISSIONING TOOL SETUP WITH HARD WIRED DMX CONTROL
DMX HARD WIRING FOR FIXTURES WITH LCT COMMISSION
TOOL SETUP
Aura Fixtures are capable of control via DMX inputs. For "CX"
models, the DMX controls are provided via a Digital Control Adapter
onboard the fixture. It is possible to control multiple fixtures from a
single Digital Control Adapter. The Digital Control Adapter is
addressable. One adapter per fixture makes each fixture
addessable. Multiple fixtures on one adapter are not individually
addressable. Consult factory for configuration questions.
NOTES:
1. Maximum of 32 fixtures in Parallel/Star with one 120 ohm
terminator at end of run. Maximum run distance 1800 feet.
2. Additional fixtures, or additional length, may be added by use of a
DMX Booster (by others).
3. Module Data +/- wiring is class 2 rated. RS-485.
4. Suggested control wire (onless otherwise required by code) is
Belden or equal #9842 2-Pair, Polyethylene Insulation, Chrome PVC
Jacket, Drain Wire, UL AWM Style 2919, 30V 80degC, DMX 512.
POWER (120/277VAC) TO FIXTURE TO BE CONSTANT - DO NOT
SUPPLY POWER FROM SWITCHED SOURCE
4LE-AURA-CT with "IX" Setup / Control Option
iOS APP SETUP WITH HARD WIRED DMX CONTROL
DMX HARD WIRING FOR FIXTURES WITH iOS APP SETUP
Aura Fixtures are capable of control via DMX inputs. For "IX"
models, the DMX controls are built into the LED Module.
Configuration of DMX Channels is accomplished thru the iOS
APP. Each fixture is individually addressable.
NOTES:
1. Maximum of 32 fixtures in Parallel/Star with one 120 ohm
terminator at end of run. Maximum run distance 1800 feet.
2. Additional fixtures, or additional length, may be added by use
of a DMX Booster (by others).
3. Module Data +/- wiring is class 2 rated. RS-485.
4. Suggested control wire (onless otherwise required by code) is
Belden or equal #9842 2-Pair, Polyethylene Insulation, Chrome
PVC Jacket, Drain Wire, UL AWM Style 2919, 30V 80degC,
DMX 512.
POWER (120/277VAC) TO FIXTURE TO BE CONSTANT - DO
NOT SUPPLY POWER FROM SWITCHED SOURCE
100 GILBANE STREET - WARWICK, RI - 02886
TEL: (401)738-7266 FAX: (401)738-0618
www.PMCLIGHTING.com
CONSULT FACTORY OR VISIT OUR WEBSITE FOR SPECIFIC INSTALLATION INSTRUCTIONS
Specifications and Dimensions are subject to change without notice.
2LEM-AURA - 000
INSTALLATION / WIRING
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING LUMINAIRE.
This luminaire is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before installation.
To prevent electric shock, turn off electricity at main power supply before proceeding. Retain these instructions for maintenance reference.
4LE-AURA-CT with "CE" or "IE" Setup / Control Option
COMMISSIONING TOOL or iOS APP SETUP WITH HARD WIRED LUTRON ECOSYSTEM CONTROL
LUTRON ECOSYSTEM HARD WIRING FOR FIXTURES
WITH LCT COMMISSION TOOL or iOS APP SETUP
Aura Fixtures are capable of control via Lutron ECOSystem
inputs. Lutron ECOSystem controls are provided via a
Digital Control Adapter onboard the fixture. It is possible to
control multiple fixtures from a single Digital Control
Adapter. The Digital Control Adapter is addressable. One
adapter per fixture makes each fixture addessable. Multiple
fixtures on one adapter are not individually addressable.
Consult factory for configuration questions.
NOTES:
1. Maximum of 32 fixtures in Parallel/Star with one 120 ohm
terminator at end of run. Maximum run distance 1800 feet.
2. Module Data +/- wiring from Digital Control Adapter to
LED Module (if required - multiple LED Modules with one
DCA) is class 2 rated. RS-485. By others.
3. Suggested control wire (unless otherwise required by
code) is Belden or equal #9842 2-Pair, Polyethylene
Insulation, Chrome PVC Jacket, Drain Wire, UL AWM Style
2919, 30V 80degC, DMX 512.
POWER (120/277VAC) TO FIXTURE TO BE CONSTANT DO NOT SUPPLY POWER FROM SWITCHED SOURCE
100 GILBANE STREET - WARWICK, RI - 02886
TEL: (401)738-7266 FAX: (401)738-0618
www.PMCLIGHTING.com
CONSULT FACTORY OR VISIT OUR WEBSITE FOR SPECIFIC INSTALLATION INSTRUCTIONS
Specifications and Dimensions are subject to change without notice.
2LEM-AURA - 000
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.