Technical Datasheet Technisches Datenblatt 1/2
Conduit
flexible, divisible, IP40
Wellrohr
exibel, teilbar, IP40
PPCOF
PMA Divisible System
application • in machine building and plant construction
material • specially modified polypropylene PP
characteristics • can be opened and closed again
in longitudinal direction any time
• PMA standard nominal widths can be used
in combination with all PMA fittings
• easy installation
• trouble-free retrofitting
• applicable also for repairs
• self-extinguishing
temperature range –20°C ... +105°C continuous, +150°C short-term
compatible with divisible fittings and lock nuts,
types BLNO-M and BLN-M
and all standard PMA fittings
colour black
order no. conduit size fits to rec. fitting
black NW metr. system
support
Bestell-Nr. Rohr-
grösse
schwarz NW metr. System-
halter
PPCOF-07B 07 10 BFH-07-0 07 M12x1.5 5.6 10.0 25 3.2 2.0 0.15 1.9 50
PPCOF-10B 10 12 BFH-10-0 10 M12x1.5 8.5 12.8 28 3.6 2.2 0.15 2.8 50
PPCOF-12B 12 16 BFH-12-0 12 M16x1.5 11.0 15.6 35 3.5 2.1 0.15 3.7 50
PPCOF-17B 17 20 BFH-17-0 17 M20x1.5 15.1 21.1 45 4.1 2.6 0.15 5.6 50
PPCOF-23B 23 25 BFH-23-0 23 M25x1.5 22.1 28.4 60 4.0 2.3 0.20 9.5 50
PPCOF-29B 29 32 BFH-29-0 29 M32x1.5 26.6 34.5 100 4.0 2.5 0.20 12.8 50
PPCOF-36B 36 40 BFH-36-0 36 M40x1.5 31.8 42.4 120 8.2 5.0 0.25 15.0 30
PPCOF-48B 48 50 BFH-48-0 48 M50x1.5 43.9 54.1 140 7.0 4.8 0.30 22.5 30
PPCOF-70B 70 80 - PMAGRIP NW70 - 60.5 78.0 200 8.6 5.1 0.25 44.0 10
Our customer service dept. or local distribution partner will be pleased to help you concerning product availability and lead time
Unser Kundendienst oder die lokale PMA-Vertretung gibt Ihnen über die Artikelverfügbarkeit und Lieferzeit gerne Auskunft
PMA fittings
for NW
passend zu empf.
PMA-Verschr.
für NW
thread
metric d1 d2 R
Verschr.-Gew.
metrisch d1 d2 R
Teilbares PMA-System
Einsatzbereich • im Maschinen- und Anlagenbau
Material
Eigenschaften
Temperaturbereich –20°C ... +105°C kontinuierlich, +150°C kurzzeitig
passend zu teilbaren Verschraubungen und Gegenmuttern,
Farbe schwarz
• speziell modifiziertes Polypropylen PP
• lässt sich in Längsrichtung jederzeit öffnen
und wieder schliessen
• PMA Standard-Nennweiten können mit sämt-
lichen PMA-Verschraubungen kombiniert werden
• einfachste Installation
• problemlose Nachinstallation
• auch geeignet zu Reparaturzwecken
• selbstverlöschend
Typen BLNO-M und BLN-M
und alle Standard-PMA-Verschraubungen
dimensions in mm (nom.) weight packing
stat.
Dimensionen in mm (nom.) Gewicht Verp.-
stat.
a b s
min.
a b s
min.
kg/100 m PU/m
unit
Einheit
kg/100 m VE/m
Dimensions Dimensionen
ab
s
Code reference Nr.-Schlüssel
PPCO = type Typ
F = flame retarded ammwidrig
10 = nominal width Nennweite
= colour-black Farbe schwarz
B
-
F
BPPCO 10
PPCOF-Index
min. max.
ductility Biegbarkeit
fatigue / reversed bending Dauer- / Biegewechselfestigkeit
pressure resistance Druck- / Trittfestigkeit
cold temperature performance Kälteeigenschaften
weather resistance Witterungseigenschaften
R stat. = lowest recommended bending radius
for static (fixed) installation
kleinster empfohlener Biegeradius für
statische (feste) Verlegung
Technical Datasheet Technisches Datenblatt 2/2
Conduit
flexible, divisible, IP40
Wellrohr
exibel, teilbar, IP40
PPCOF
PMA Divisible System
properties unit value test method according to
Eigenschaften Einheit Wert Prüfmethode nach
Mechanical properties Mechanische Eigenschaften
Impact strength
Compression strength
Pull-out resistance conduit/fitting: Ausreissfestigkeit Wellrohr/Verschraub.:
Connector type BLNO Verschraubung Typ BLNO
Testing at 23°C, 50% r.h., conduit Prüftemperatur 23°C, 50% r.F., Rohr-
nominal width 17, unless otherwise nennweite 17, sofern nicht anders
stated angegeben
Thermal properties Thermische Eigenschaften
Continuous application temperature Dauergebrauchstemperatur
Upper application temperature obere Anwendungstemperatur
Short-term kurzzeitig °C +150 500 h
Fire safety characteristics Brandschutzeigenschaften
Flame class Flammklasse
Schlagfestigkeit (+23°C) J > 4.5 PMA DO 9.21-4330
Scheiteldruckfestigkeit N > 180 PMA DO 9.21-4320
Teilbares PMA-System
N > 125 PMA DO 9.21-4610
°C –20 ... +105 PMA DO 9.21-4510
°C +120 3‘000 h
V2 UL 94
Environmental properties Umwelteigenschaften
RoHS and REACH compliant RoHS- und REACH-konform
Weathering resistance Witterungsbeständigkeit
Weathering (UV/humidity) Bewitterung (UV/Feuchte)
for black colour für schwarze Farbe
Chemical properties Chemische Eigenschaften
Content of delivery Lieferumfang
Conduit Wellrohr
In addition to the national and international standards which consider mainly material properties and general product performance, PMA applies its own internally developed standards when assessing the system
suitability of cable protection products. The PMA standards are based on 30 years experience and allow a better assessment of whether a product is practically appropriate for a specific application.
Neben internationalen und nationalen Normen, die sich vor allem auf Materialeigenschaften und allgemeine Produkteigenschaften beziehen, wendet PMA ergänzend selbst denierte Werknormen zur Beurteilung
der Systemeigenschaften von Kabelschutzprodukten an. Diese erlauben auf der Basis über 30 jähriger Erfahrungen eine bessere Beurteilung der praktischen Eignung eines Produktes für spezische Anwendungen.
yes / ja EU Directive 2002/95/EC
very good /
sehr gut