Pluribus Networks Freedom Series Quick Start Manual

Secondary DNS IP (0.0.0.0): ip-address <return> Domain name (pluribusnetworks.com): domain-name <return> Automatically Upload Diagnostics (yes): <return>
NOTE: The MGMT and in-band IP addresses must be on separate networks.
Pluribus Networks Freedom Series
Quick Start Guide
Quick Start Guide Overview
This guide describes the inial setup of a Pluribus Networks server-switch, and is intended for experienced network administrators. You are guided through the inial configuraon of a Pluribus Networks server-switch and the inial connecvity to your management and data
networks.
Pluribus Networks server-switches provide out-of-band management on the MGMT1 port. A separate interface provides in-band management which is configured during inial setup. Use the in-band interface to manage available services on the server-switch such as SSH or vManage.
This guide assumes that you have basic networking skills including Layer 2 and Layer 3, along with basic system administraon skills, and you have installed your server-switch in your network rack.
Console Port F64
Console PortE28Q
Before You Begin
Gather the following informaon:
System Name:______________________________________________ Password for network-admin(default login):______________________
(Six characters or more required.) MGMT interface IP address and netmask:________________________
In-band IP address and netmask:_______________________________
Default gateway IP address:___________________________________
CAUTION! Do not connect any ports to the network unl the server-switch is configured. You can accidentally create loops on the network which may cause network connecvity problems..
1. Log into the server-switch with the username network-admin and the default password, admin.
2. Accept the EULA by entering Yes. To view the EULA, type eula and the
enre EULA is displayed for your review.
3. You can begin inial configuraon using the setup quesons in the Quick Start Wizard.
console login: network-admin Password: admin Last login: Fri Oct 3 12:23:04 on console Pluribus Command Line Interface v2.2 System setup required: System Name (switch): hostname <return> network-admin Password: password <return> Re-enter Password: password <return> Mgmt IP/Netmask: ip-address/netmask <return> In-band IP/Netmask: ip-address/netmask <return> Gateway IP (0.0.0.0): ip-address <return> Primary DNS IP (0.0.0.0): ip-address <return>
Performing the Inial Configuraon
Note: Fabric Communicaon
All fabric communicaon occurs over the in-band or MGMT interfaces
on a server-switch.
In order for server-switches to form a fabric, the server-switches communicate using Layer 2 or Layer 3 networking on the in-band or MGMT interfaces.
You must create a fabric even if you have only one server-switch. If the server-switch is joining an exisng fabric, then you can add it to the fabric using a few simple commands.
1. To create a new fabric name corp-fabric, use the following command:
>fabric-create name corp-fabric network-type
in-band|mgmt
2. You can create a password for the fabric so that other server-switches can only join the fabric if the administrator knows the password. Add the password, sw0rdf1$h, using the following command:
>fabric-create name corp-fab password <return>
password: <sw0rdf1$h> You can now join the fabric, corp-fabric, using the fabric-join command:
>fabric-join name corp-fab <return>
fabric password:<sw0rdf1$h>
1
2
Joining an Exisng Fabric
When a server-switch joins an exisng fabric, it receives the rest of the configuraon from the fabric and then keeps track of the fabric state.
1. To join the an exisng fabric, ,network-fab, use the fabric-join
command:
>fabric-join name network-fab
2. If the fabric was created with an oponal password, you must enter the correct password to join the fabric:
>fabric-join name network-fab password
fabric password: <password>
Using the fabric-join command restarts nvOS and causes a short interrupon on the network.
Once you complete the inial configuraon, you can display the system
setup using the switch-setup-show command. Plug your network cable
into the MGMT port and the network port.
Configuring the Inial Fabric
3
Console Port E68
You can connect to the server-switch by connecng a rollover cable to the console port or connecng a keyboard and monitor
to the server-switch.
Connect the console port on the server-switch to your laptop or terminal concentrator using a serial cable.
Set terminal emulator connecon to 9600 bps, 8 data bits, parity - none, stop bits 1, flow control - none.
Plugin and power on the server-switch.
qsg-glossy-final-new-green-bleeds.pdf 1 12/14/2015 11:18:10 AM
Aer you’ve connected your server-switch, you may want to take the me to ensure that you have connecvity by pinging an external IP address.
To ping the external network from the server-switch, use the ping command:
>ping 98.138.253.109 : 56 data bytes
98.138.253.109 is alive.
To ping a domain, use the ping command again:
>ping yahoo.com yahoo.com is alive.
You are now ready to connect your ports to the network .
4
Configuring Port Connecvity
A port on the server-switch becomes acve automacally aer a cable
is connected to another device on the network. To check port status,
use the following command:
>port-show port 31 format all layout vertical switch: corp1 port: 31 ip: 192.168.42.10 mac: 64:0e:94:28:00:8e hostname: pubdev01 status: up,LLDP lport: 31 rport: 31 config: fd,10g trunk: auto-129
The port comes up with RSTP and LLDP enabled but no LACP trunk.
Connecng to a Third Party Switch or Server
To connect to a third party switch or server, you may need to change the speed on the interface, turn off autonegoaon, or adjust other sengs on the port. It is important to match the interface sengs of the server­switch to interfaces on other devices.
5
8
Subming a Service Request
You can purchase oponal support contracts from your partner, reseller, or Pluribus Networks. Purchasing a support contract from a local partner is somemes preferred due to geographical or language requirements. Please contract your local partner to beer understand the available service
programs and pricing.
If you purchased a Pluribus FreedomCare maintenance agreement, you can contact Pluribus Networks directly for support requirements. To review the various service offerings, please visit
www.pluribusnetworks.com/support, or you can send your inquiries to servicerenewals@pluribusnetworks.com.
For those under a current PluribusCare contract, you may submit support requests through the Pluribus Networks customer portal, by e-mail, or by telephone. Please visit www.pluribusnetworks.com/support. To provide technical feedback on this document, or to report errors or omissions, please send your comments to
doc-feedback@pluribusnetworks.com.
Confirming Connecvity on the Network
Documentaon
Product documentaon is located at
www.pluribusnetworks.com/support/documentaon.
You can login using your username and password sent to you by the Pluribus Networks Support team.
pnsupport@pluribusnetworks.com
Pluribus Networks
2455 Faber Place Suite 100 Palo Alto, CA 94303
855.GET.VNET
Instrucons for upgrading to the latest version of nvOS may be obtained from your partner. If you have purchased a FreedomCare contract, the instrucons are included in the Release Notes located at
www.pluribusnetworks.com/support/documentaon.
Upgrading soware requires a connecon to the Internet or you can upgrade using offline soware packages located on the Pluribus Support
site.
Upgrading nvOS Soware Using Offline Packages
To upgrade nvOS without an Internet connecon, you can download and install offline packages. You need soware such as Winscp for Windows or use the terminal applicaon on your Mac.
1. Log into nvOS and use the admin-sftp-modify command to enable SFTP and create a password for SFTP.
2. Launch your SFTP client and create a profile for the server-switch using sp as the user name and the password you created.
3. Connect to the server-switch and accept the key for the first me.
4. Navigate to the import/ folder and copy the downloaded nvOS package.
5. Return to the server-switch and log into it using SSH.
6. Run the following command:
>software-upgrade package import/nvOS-2.2.X-XXXX­ platform.pkg
The plaorm is either aquila (F64) or leo (E68 or E28Q). The soware automacally begins upgrading to the new version. You can
monitor the upgrade process using the software-upgrade-status-show
command. Once the upgrade is complete, the server-switch automacally reboots to the new version of nvOS.
3. To show fabric details, use the fabric-show command:
>fabric-show
name switch-ip id vlan network-type tid
-------------------------------------------------- -----
corp-fab 192.168.11.1 a000030:5537b46c 3 in-band 216
Use the following command:
>port-config-modify
The server-switch port connected to a server becomes acve once a cable is connected and the server NIC is acve.
You add VLANs to the server-facing port as necessary and configure them as tagged or untagged depending on your requirements. To create a VLAN and then assign it to the port use the commands:
>vlan-create id 21 scope local
>vlan-port-add id 21 port 54 untagged > vlan-show id 21 switch id scope name ports untagged-ports
-------- -- ----- ------- ------------ -------------­corp1 21 local vlan-21 54,65-72,129 54
6
Upgrading nvOS Soware
Licensing Informaon
7
The server-switch comes pre-installed with a base license. To view license details, use the software-license-show command.
To install a new license, use the software-license-install command and follow the instrucons on the license cerficate included with the documentaon package.
To upgrade a license use the software-license-upgrade command and follow the instrucons on the license cerficate.
P/N 17-0002 Rev C
qsg-glossy-final-new-green-bleeds.pdf 2 12/14/2015 11:18:10 AM
Loading...