1. Please read this manual thoroughly before operating the monitor.
2. Unplug monitor from the wall outlet before cleaning the LCD screen. Do not use liquid cleaners or aerosol
cleaners. Use ONLY a damp cloth provided.
3. Don’t use any unauthorized accessories not recommended by the manufacturer as they may cause
hazards.
4. Don’t operate this monitor near damp or wet surfaces.
5. Use only the recommend manufacturer mounting hardware accessories.
PORTABLE CART WARNING
(symbol provided by RETAC)
Slots and openings in the cabinet and the back or bottom are provided for
ventilation, and to insure reliable operation of the monitor and to protect it
from overheating, these openings must not be blocked or covered.
6. This appliance should be operated only from the type of power source
indicated on the marking label.
If you are not sure of the type of power supplied to your home, consult your
dealer or local power company. For appliance designed to operate from
battery power, refer to the operating instructions.
7. This appliance system is equipped with a 3-wire grounding type plug (a plug having a third (grounding) pin).
This plug will only fit into a grounding-type power outlet. This is a safety feature.
If you are unable to insert the plug into the outlet, contact your electrician to replace your outlet.
Do not ignore the safety purpose of the grounding plug.
8. For added protection for this product during a lightning storm, or when it is left unattended and unused for
long periods of time, unplug it from the wall outlet. This will prevent damage to the product due to lightning
and power-line surges.
9. Do not allow anything to rest on the power cord.
10. Follow all warnings and instructions marked on the appliance.
11. Do not overload wall outlets and extension cords as this can result in fire or electric shock.
12. Do not attempt to service this monitor without a qualified service personnel.
2
Page 3
FCC Notice
This device complies with Part 15 of FCC Rules.
Operation is subject to the following two conditions:
(1)This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
To assure continued compliance, follow the attached installation instruction and do not make any unauthorized
modifications.
Note:
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
The user may find the booklet “Something About Interference” available from FCC local regional offices helpful.
Warning:
To assure continued FCC emission limit compliance, the user must use only shielded interface cables when
connecting to host computer or peripheral devices. Also, any unauthorized changes or modifications to this
equipment could void the user’s authority to operate this device.
3
Page 4
Safety Precautions
WARNING:
CAUTION
RISK OF ELECTRICAL SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE ELECTRICK SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
The lightning flash with arrowhead symbol,
within an equilateral triangle, is intended to
alert the user to the presence of uninsulated
“dangerous voltage” within the product’s
enclosure that may be of sufficient magnitude
to constitute a risk of electric shock to persons.
The exclamation point within an equilateral
triangle is intended to alert the user to
the presence of important operating and
maintenance (servicing) instructions in the
literature accompanying the appliance.
TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD, DO
NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD,
KEEP THIS EQUIPMENT AWAY FROM ALL LIQUIDS. USE
AND STORE ONLY IN LOCATIONS WHICH ARE NOT
EXPOSED TO THE RISK OF DRIPPING OR SPLASHING
LIQUIDS, AND DO NOT PLACE ANY LIQUID CONTAINERS
ON TOP OF THE EQUIPMENT.
CAUTION:
In order to maintain adequate ventilation, do not install or
place this unit in a bookcase, built-in cabinet or any other
confined space. To prevent risk of electric shock or fire
hazard due to overheating, ensure that curtains and any
other materials do not obstruct the ventilation.
CAUTION:
TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD AND
ANNOYING INTERFERENCE, USE THE RECOMMENDED
ACCESSORIES ONLY.
CAUTION:
This apparatus can be operated at a voltage in the range of
100-240 V AC.
THIS EQUIPEMNT MUST BE GROUNDED
To ensure safe operation, the three-pin plug must be inserted
only into a standard three-pin power outlet which is effectively
grounded through normal household wiring. Extension cords
used with the equipment must have three cores and be
correctly wired to provide connection to the ground. Wrongly
wired extension cords are a major cause of fatalities. The
fact that the equipment operates satisfactorily does not imply
that the power outlet is grounded or that the installation is
completely safe.
For your safety, if you are in any doubt about the effective
grounding of the power outlet, please consult a qualified
electrician.
CAUTION:
THE AC RECEPTACLE (MAINS SOCKET OUTLET) SHALL
BE INSTALLED NEAR THE EQUIPMENT AND SHALL BE
EASILY ACCESSIBLE.
TO COMPLETELY DISCONNECT THIS EQUIPMENT FROM
THE AC MAINS, DISCONNECT THE POWER CORD PLUG
FROM THE AC RECEPTACLE.
Voltage other than 120V are not intended for U.S.A and
Canada.
CAUTION:
Operation at a voltage other than 120V AC may require
the use of a different AC plug. Please contact either a local
service center for assistance in selecting an alternate AC
plug.
Notice (U.S.A. only):
This product has a fluorescent lamp that contains a
small amount of mercury. It also contains lead in some
components. Disposal of these materials may be regulated
in your community due to environmental considerations. For
disposal or recycling information please contact your local
authorities, or the Electronics Industries Alliance:
http://www.eiae.org.
4
Page 5
Safety Precautions continued
Caution for AC Power Cord
FOR YOUR SAFETY PLEASE READ THE FOLLOWING TEXT CAREFULLY.
Appropriate AC Power Cord must be used in each local area.
FOR CONTINENTAL EUROPE, ETC
Not for use in the U.K.
FOR U.S.A. and Canada
Information on Disposal for Users of Waste Electrical & Electronic Equipment (private households)
This symbol on the products and/or accompanying documents means that used electrical and
electronic products should not be mixed with general household waste.
For proper treatment, recovery and recycling, please take these products to designated
collection points, where they will be accepted on a free of charge basis. Alternatively, in some
countries you may be able to return your products to your local retailer upon the purchase of an
equivalent new product.
FOR U.K. ONLY
If the plug supplied is not suitable for your socket outlet,
it should be cut off and appropriate one fitted.
Disposing of this product correctly will help to save valuable resources and prevent any potential negative effects
on human health and the environment which could otherwise arise from inappropriate waste handling. Please
contact your local authority for further details of your nearest designated collection point.
Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.
For business users in the European Union
If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further
information.
Information on Disposal in other Countries outside the European Union
This symbol is only valid in the European Union.
If you wish to discard this product, please contact your local authorities or dealer and ask for the correct method of
disposal.
CE NOTICE
This is Class B product. In a domestic environment this may cause radio interference in which
case the user may be required to take adequate measures.
The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids,
such as vases, shall be placed on the apparatus.
14. Update and Modification of Product ......................................................................... 29
6
Page 7
1. Outline
The PLURA PBM-070/PBM-070X is a comprehensiveand powerful monitor that consists of true black wide screen
7” LCD with LED backlighting technology that graties all type of users. The PBM-070/PBM-070X Series supports
HD / SD-SDI, RGB, Component and Composite signals.
The PBM-070/PBM-070X offers an elegant slim design with fast response time for smooth video streaming, high
brightness, contrast ratio, wide viewing angles, accurate color reproduction and quality picture consistency
that meets your HD Monitoring application.
The PBM-070/PBM-070X supports an auto calibration mechanism using ICAC (Intelligent Connection for Alignment
& Calibration) and sophisticated calibration tools to adjust and calibrate color temperatures and gamma settings.
In addition the new and advanced Plura PBM-070/PBM-070X supports Closed Captioning CEA (608 / 708),
advanced Waveform (Y.Cb.Cr, selectable), Vector Scope (75%,100%), and EBU / User Markers & Source ID display.
The PBM-070/PBM-070X also provides various display functionality such as time code, audio metering display and
offers user friendly menu functions to control brightness, color temperature and EQ function of HD SDI input.
2. Main Features
• Complies with EBU-2330 TECH, SMPTE-C and ITU-R BT.709 Standards
• Cutting edge De-interlacing and Scaling Technology
This is the Analog input terminal. Three types of input signal are supported.
1) Composite 1,2,3
2) Component Y,U,V (Y,Pb,Pr) and R,G,B
3) S-Video(Y,C).
Please refer to section 5 “Input Select” for more detailed information.
LOOPOUT Terminal ,BNC -> Option
Loop output terminal of Analog input signal. If you do not need the LOOP output, select
“Analog Loop: NO” in the OSD menu.
DVI-I / PC-RGB Input Terminal (DVI-I Jack)
1) DVI Digital Signal Input.
2) When using DVI to VGA Gender, PC-RGB(VGA) Signal Input available.
REMOTE Port ,RJ-45 Jack –Through (RJ-45)Terminal -> Option
Terminal for controlling the monitor by an external control. (Make/Trig Type)
Please refer to section 8 “Remote Terminal Assignment” for more detailed information.
10
11
12
Audio Input/Output Terminal
Input/Output terminal for the external Audio and Embedded Audio Signal.
Please refer to 3-3 Audio Input/Output.
UPDATE Port (RJ-11 Jack)
Serial Communication Port
This port is used to modify the monitor program or to control the Monitor.
Please refer to section 7 “Program Update Port” for more detailed information,
DC INPUT Terminal
Used to supply DC power. Please verify DC voltage Input. In case of Battery power, the
range is 11V to 17V.
11
Page 12
3. Controls continued
3-3. Tally & Audio
1. Tally
2. Audio
1
2
Input/Output
Analog Audio L/R Input Terminal (RCA Phone Jack)
Analog Audio L/R Input Terminal
The external
Analog Audio L/R Output Port (Stereo Pin Jack)
Te rmi nal
available
12
Three Tally Colors are supported by external contact terminal
GPI 5 ON=> RED, GPI 6 ON GREEN, GPI 5&6 ON => YELLOW
1
2
audio
signal
is
for output of
by a Menu Setting.
De-embedded Analog
available
Please refer
through the
Tally La mp
speaker
Audio
to 6-6 Embedded Audio Setup for more
by a Menu setting
signal
from
SDI. The
16ch Audio
Signal
detailed
output is
information.
Page 13
3. Controls continued
3-4. Function Buttons for FUNCTION 1 and FUNCTION 2
Used to select the functions to be assigned to individual buttons F1 and F2 (front-panel buttons).
Selectable Functions:
Note:
1. H/V Delay On/Off
2. Blue Only-Grayscale On/Off
3. Audio Display On/Off
4. Pixel to Pixel On/Off
5. Anamorphic On/Off
6. Aspect
7. 1 : 1 Scan
8. Waveform Display
9. Time Code Display
10. Audio Mute On/Off
11. PaP On/Off
When the input modes are DVI, PC-RGB signal, the
following functions are not available:
1) H/V Delay
2) Gray (MONO)
3) MARKER
4. Display Status
This is used to confirm the operating status. Some functions are not supported, depending on the installed options.
Video Waveform
& Vectorscope
Display Left:
CH-1
CH-3
CH-5
CH-7
CH-9
CH-11
CH-13
CH-15
Closed Caption Display:
Time Code Display
Closed Caption !
High Quality & Multi Format LCD Monitor
Standard 608 (VANC, Transcoded, Line 21), 708 (SDI Digital)
12:20:50:19
Displays up to 16 channels(L/R each 8channels) of audio level by De-Embedded
of HD/SD-SDI’s serial Audio Signal.
Display Right:
CH-2
CH-4
CH-6
CH-8
CH-10
CH-12
CH-14
CH-16
13
Page 14
4. Display Status continued
1. Audio Level Meter Display
Set “ON/OFF” and “ Position” from the Audio Level Display Menu.
On: Left (even channel), Right (odd channel), OFF : Hide Level Bar
Level Meter Position: Position audio display at the top or bottom of the screen.
2) Waveform Monitor/Vector Scope Display
Set “ON/OFF” and “Position” from the W-FORM/VECTOR Button WFM/Vector Position : Position
Waveform/Vector from Display Menu( Left Top, Right Top, Left Bottom, Right Bottom)
(These functions are available only in SDI, CVBS, S-Video, YPbPr Mode).
Display Position is can be toggled when Up( ) button is pressed.
3) Time Code Display (SDI Input Mode)
Set “ON/OFF” and “Position” from Display Menu Setup.
Time Code Position : Position Time Code at the top or bottom of the screen.
5. Input Select Menu
INPUT MODE DISPLAY
These buttons are used to select desired video input or
to convert the corresponding video input. Information for
selected input signal can be viewed for 3 seconds through
Mode Display Window displayed at the left top of the screen.
When Menu control is not ON, if user press Enter button, then
currently selected input information appears.
When changing the input signal, there is a possibility that the signal will not be detected,
or the mode indication may be incorrect, or the screen size may be displayed incorrectly.
14
Page 15
6. Control and Use of OSD Menu
1. Press “MENU” button for OSD Display .
2. Press “ENTER” button after menu selection by using UP ( ) / DOWN ( ) buttons.
3. Adjust status on the selected item with ENTER and UP ( ) / DOWN ( ) buttons.
4. Move to previous menu by using MENU button;
5. Close the OSD screen by holding MENU continuously.
If there is no input signal or no detected signal, the menu might not be displayed.
If you set the menu with an unstable signal status, it may cause an error.
The MENU setting values depend on the input signal mode. Therefore, please check the
input mode at the bottom of the menu when changing settings.
6-1. Video Setup
•Brightness: Adjusts brightness
•Contrast: Adjusts contrast
•Chroma:Adjusts chroma
•Phase:Adjusts phase
•Sharpness:Adjusts sharpness (This function can be
controlled by VR control Knob on the front panel.)
Note: In PC-RGB Input Mode,
•RGBColorSet:Controls RGB Level in YPbPr,RGB,PC-
RGB input mode. Select Default or User Adjust
•NTSCSetup:Select 0 IRE or 7.5 IRE. 7.5 IRE is used in
NTSC or YUV mode.
•AnalogLoop(Option): This function is only available
on products with the Loop Terminal. Set up On/Off
impedance of Analog Loop output terminals. Yes ->using
Loop output. No -> Not using Loop output.
When Loop terminal is not used, select Analog Loop ‘No’
15
Page 16
6. Control and Use of OSD Menu continued
6-1-1. VIDEO (PC-RGB Mode) Setup
This Menu is displayed when selecting Auto Color Adjust
as User Adjust in YPbPr, RGB, PC-RGB Input Mode
•PaPSub:Selects input of right (sub) screen from PaP
(Picture and Picture) mode. Selectable sub source is
automatically changed depending on Main Source.
PaP MainPaP Sub
16
Page 17
6. Control and Use of OSD Menu continued
6-2-1. DISPLAY (PC-RGB)
•WFM&VectorPosition: Display’s input signal as a format of waveform on the screen .
Display Position: locates the Waveform & vector scope Position
Display Position can be located in any of the four corner.
This is displayed when PC-RGB signal is selected.
•PCSCAN: Set output status as Fill or Aspect mode.
•V.Position: Adjust vertical position of screen for PC mode
input.
•H.Position: Adjust horizontal position of screen for PC
mode input.
•Phase: Adjust digital sampling phase of SC of input signal
(VGA mode).
•Clock: Used to adjust digital sample clock in PC-RGB
mode. (VGA)
•AUTOAdjust: Used to adjust the best display position
automatically in PC-RGB mode. (VGA)
•PaPMain,PaPSub(Option): Select input of right (Main) /
left (Sub) screen in PaP mode.
Display Position:
Left Upper, Right Upper, Left Bottom,
Right Bottom
Vector
Waveform
•VectorColor75%/100%:
Sets Input Color Reference Level in Vector Display.
Depending on 100% or 75%, Color, Marker position is changed.
•TimeCodeDisplay(Option):Displays Time Code on the screen in HD/SD-SDI signal input
•PixeltoPixel(Option): This displays native input HD-SDI signal, 1920 x 1080 without scaling down. The
active display can be set to Left Upper, Right Upper, Left Bottom, Right Bottom, and Center.
Depending on the screen size & input signal resolution, pixel to pixel indicator moves as follows.
Shift ( ) button
17
Page 18
6. Control and Use of OSD Menu continued
6-3. COLOR Setup
•ColorTemperature: Set the color temperature or White
Balance on screen among VAR 3200°K, 5400°K,
6500°K, 9300°K, USER.
•VARNumber-> Selectable in steps from 1 to 63 from
3000°K ~ 9300°K
•USER-> Controls each RGB Gain and Bias.
•R,G,BGain: Individually Controls R,G & B Gain in the
User Mode.
•R,G,BBias: Individually Controls R,G & B bias in the
User Mode
•Clock: Adjusts digital sample clock in PC-RGB mode
•AUTOAdjust: Adjusts the best display position
automatically in PC-RGB mode (VGA)
•PaPMain,PaPSub(Option): Selects main input in PaP
mode (left), Selects sub input in PaP. Please refer to
section 6-2 for detailed
Use professional probe (not included) to adjust Color Temperature (White Balance)
to precise adjustment.
Color matrix Parameters use ITU Standard color. EBU color is set assuming parameters for an LCD panel;
the best color is produced according to the standard for SDTV (ITU-R/BT.601) and HDTV (ITU-R/BT.709).
18
Page 19
6. Control and Use of OSD Menu continued
6-4. MARKER Setup
•SafetyArea4:3:Selects the range of the Safe Area in 4: 3 SD mode.
95%, 93%, 90%, 88%, 85%, 80%, EBU Action 16:9, EBU Graphic 16:9, EBU Action 14:9, EBU Graphic
14:9,EBU Action 4:3, EBU Graphic 4:3,Off
•CenterMarker: Center Marker ON / OFF
•Marker16:9
Set the type of marker when the aspect ratio setting is
16 : 9 in HD signal.
•TypeofMarker
4:3,15:9,14:9,13:9,1.85:1,2.35:1, USER, Off
•SafetyArea16:9
Selects the size of the safe area in 16 : 9 HD screen.
95%, 93%, 90%, 88%, 85%, 80%, Off
EBU Action 16:9,EBU Graphic 16:9,
EBU Action 14:9,EBU Graphic 14:9,
EBU Action 4:3,EBU Graphic 4:3,Off
•MarkerColor:Selects Marker Color: White, Red, Green, Blue, Gray, Black
•MarkerBackColor: Sets background transparency among Normal, Half, and Grayscale excluding Safety area.
•MarkerThickness: Sets Marker Thickness as Pixel unit(1~10 pixel)
•UserMarkerH1: Set the vertical line of Marker (left side: refer to below picture)
•UserMarkerH2: Set the vertical line of Marker (right side)
•UserMarkerV1: Set the horizontal line of Marker (upper)
•UserMarkerV2:Set the horizontal line of Marker (lower)
Marker H1Marker H2
Marker V1
Marker V2
19
Page 20
6. Control and Use of OSD Menu continued
6-5. OSD Setup
•ClosedCaption: This function is available in Composite, YPbPr and Digital (HD/SD-SDI) signal.
There are three selectable mode : OFF, CC 708, CC 608 (Transcoded, VANC, Line 21)
This function displays character information included in CC signal on the screen.
•Status/MenuDisplayTime
Sets Menu and Information.
Select one of off, 0(continute)~60 seconds.
•Status/MenuBlend
Set transparency of menus and Indication windows on
the screen Selects 0~15 levels
•MenuPosition
Select for Center, Left Top, Right Top, Left Bottom,
Right Bottom.
•InternalPattern: Without additional Input signal, it provides internal Test Pattern of 1920 x1080 30p format
on the screen. (Off, Blue, Green, Red, 0~100% White)
•SourceIDDisplay: User can enter Monitor ID on the screen.
•SourceIDCharacter:User can enter Source (Monitor) ID which is displayed on the Monitor.
Up to 10 digits writable.
•SourceIDPosition: Sets ID display position (Left-Top, Left-Bottom, Right-Top, Right-Bottom, Center)
Menu Position: Left-Top, Left-Bottom, Right-Top, Right-Bottom, Center
Closed Caption !
High Quality & Multi Format LCD Monitor
CAMERA 1
Source ID
Closed Caption Display: Standard 608 (VANC, Transcoded, Line 21),
708(SDI Digital)
When Loop terminal is not used, select Analog Loop ‘No’.
20
Page 21
6. Control and Use of OSD Menu continued
6-6. AUDIO Setup
•EmbeddedAudio(L):Select Digital Audio (L) output from
1 to 16 channels when using SDI input.
•EmbeddedAudio(R): Select Digital Audio (R) output from
1 to 16 channels when using SDI input.
•AudioLevelMeter: Select ON/OFF for the function which
can display the SDI Embedded Audio signal level on a
Level Meter on the screen.
•LevelMeterPosition: Select position of Audio Level
Meter as Upper/Lower screen.
•SpeakerSource(Option): Select Speaker between Line
(external input) and SDI (De-embedded).
•SpeakerOutput(Option): Select Speaker output status
Speaker setting menu is used only when the speaker option is present.
•GPIControl:Select external control ON/OFF. It is not
possible to control with Remote terminal when it is OFF.
•GPIPort1,2,3,4,5,6,7: Assign each GPI Port of external
Remote Control Terminal (RJ-45). Double function for
each port is prohibited. Please refer to section 8-1,2,3
for detailed information.
GPI Port 7 is fixed at Standby.
•RemoteIDNumber: Set the number when controlling IR
remote controller (Option).
•SerialRemote: Select whether to use external Serial Port
control or not. Front Key and IR remote control will be
unavailable when Serial Remote is ON.
To terminate Serial Remote status (Update, Remote ON): Press Menu button for 3 sec.
21
Page 22
6. Control and Use of OSD Menu continued
6-8. SYSTEM Setup
To terminate Update Firmware status:
Press Menu button for 3 sec.
•Function1,2:Select the functions to be assigned to
individual buttons F1 and F2. Please refer to section 3-4
for detailed information.
•BackLight: Adjust brightness of LCD Panel.
•FANMotor: Sets ON/Off internal Fan motor. Only available
in 17” model.
•FrontButtonLED: Sets ON/OFF front LED
•UpdateFirmware: Used to update system software
•SetupLoad: This is used to make a group change of the
function values which have been set.
•Factory: To return to the factory default.
•User1,2,3: Menu setting is transferred to the Menu of
1,2,3 to be saved by user.
•SetupSave: Save current menu setting into one of USER
1,2,3. USER 1,2,3 can be recalled by Setup Load.
•FirmwareVersion: System software version.
•OperatingTime: Product operating time
Note: While Back Light is adjusted, LCD panel requires enough time to be stable adjusting
Phase (brightness). It requires more than 30 minutes
7. Program Update Port
7-1. Program Update Port (RJ-11)
Update Port(RJ-11) can be used in a situation as below.
1) To modify Firmware program
2) To control Color Temperature, Gamma Setting for LCD
3) To control Multi Monitors using PC Exclusive use program “Wall System Control” on PC
1 2 3 4 5 6
1 PIN NC 4 PIN GND
2 PIN RX+ 5 PIN TX+
3 PIN RX- 6 PIN TX-
Update Terminal Assignment
Update (RJ-11)
Please consult with technician for Program Update or for Serial Port use. Incorrect use of this
port may cause damage or malfunction.
22
Page 23
7. Program Update Port continued
7-2. Multi Monitor Control (through Update Port)
Multi Monitor Control can be operated by professional Adaptor (RS-232C - Serial Conversion) Converting
device and by PC where exclusive use program (Wall System Controller) is installed. (Optional)
PC (Control S/W)
Adaptor (RS-232C <-> Serial Data) Converting Device
8. Remote Terminal Assignment
8-1. Remote Terminal (RJ-45) Assignment
Each terminal function can be set from the GPI CONTROL SETUP Menu.
1 2 3 4 5 6 7 8
Remote PIN Assignment
1 PIN GPI Port 1 5 PIN GPI Port 5
2 PIN GPI Port 2 6 PIN GPI Port 6
3 PIN GPI Port 3 7 PIN GPI Port 7
(Stand by/Power ON/OFF)
4 PIN GPI Port 4 8 PIN COMMON (GND)
Remote (RJ-45)
8-2. How to connect GPI Port (RJ-11)
For each port designation, please refer to GPI & REMOTE Menu.
Connecting Method is as belows.
Control Terminal: 1 ~ 7 Pin
Contact Point Switch
It is possible to attach
pin one by one.
GND Terminal: 8 Pin of RJ-45
Please refer to section. 8-3. Remote Terminal Assignment.
23
Page 24
8. Remote Terminal Assignment continued
8-3. Remote Terminal Assignment (GPI Port)
Port Assignment Items Function Operating conditions
CVBS1 Input Switches the input CVBS1
CVBS2 Input Switches the input CVBS2
CVBS3 Input Switches the input CVBS3
SDI1 Input Switches the input SDI-1
SDI2 Input Switches the input SDI-2 (except for 7”)
DVI Input Switches the input DVI
HDMI Switches the input HDMI (except for7”)
VGA Input Switches the input PC-RGB
Y/Pb/Pr Input Switches the input YUV
RGB Input Switches the input RGB
S-Video Input Switches the input Y/C
Audio Display on, off Switches Audio Level ON/OFF Edge operation
Waveform Display On/Off Switches Waveform ON/OFF
Pixel to Pixel on, off Switches Pixel to Pixel ON/OFF.
Anamorphic on, off Switches Anamorphic ON/OFF
Tally Red on, off Switches Red LED ON/OFF of Tally Lamp Level Operation
Tally Green on, off Switches Green LED ON/OFF of Tally Lamp (Connected: ON, Open: Off)
Grayscale on/off Switches Mono ON/OFF
Blue Only on/off Switches Blue Only ON/OFF
MARKER 16:9 Selects Marker 16:9 Mode
MARKER on/off Switches Marker ON/OFF
SD Aspect on/off Switches SD Aspect ON/OFF
1:1 SCAN on/off Switches 1:1 SCAN Function ON/OFF
Center Marker on/off Switches Center Marker ON/OFF
H/V Delay on/off Switches H/V Delay Function ON/OFF
Safety Area 16:9 Controls Safety Area in 16 :9. Edge operation
Safety Area 4:3 Controls Safety Area in 4 :93
SCAN Selects Screen Size as shown in the front button
KEY-UP CURSOR UP during Menu Control.
KEY-DOWN CURSOR DOWN during Menu Control.
KEY- MENU Switches Menu ON/OFF.
KEY-ENTER Switches Enter Button ON/OFF
KEY-Standby Port 7 Fixed. (Stand by Power ON/OFF)
24
Page 25
9. List of Compatible Signal Formats
9-1. Video Signals
Composite Component
No Input Signal Formats Video
1 NTSC P- - - - -
2 PAL P- - - - -
3 525/60i (SD) - P P P - -
4 625/50i (SD) - P P P - -
5 720*480/59.94p - P - - P P
6 720*576/50p - P - - P P
7 1280*720/23.98p - - - - - -
8 1280*720/24p - - - - - -
9 1280*720/50p - P - P P P
10 1280*720/59.94p - P - P P P
11 1280*720/60p - P - P P P
12 1920*1035/59.94i - - - P P P
13 1920*1035/60i - - - P P P
14 1920*1080/50i - P - P P P
15 1920*1080/59.94i - P - P P P
16 1920*1080/60i - P - P P P
17 1920*1080/23.98p - P - P P P
18 1920*1080/23.98psf - P - P - -
19 1920*1080/24p - P - P P P
20 1920*1080/24psf - P - P - -
21 1920*1080/25p - P - P P P
22 1920*1080/25psf - - - P - -
23 1920*1080/29.97p - P - P P P
24 1920*1080/29.97psf - - - - - -
25 1920*1080/30p - P - P P P
26 1920*1080/30psf - - - - - -
27 1920*1080/50p - P - - P -
28 1920*1080/59.94p - P - - P -
29 1920*1080/60p - P - - P -
30 2048*1080/23.98p - - - P - -
31 2048*1080/23.98psf - - - P - -
32 2048*1080/24p - - - P - -
33 2048*1080/24psf - - - P - -
Y,Pb,Pr R,G,B(SOG)
HD/SD-SDI DVI HDMI
• With Analog YPbPr mode, 1035/59.94i,60i signal input, Marker is displayed in 1080/59.94i,60i and output.
• Output screen mode can be output with automatic control in DVI mode.
• STATUS Display of Input Signal might be different with real screen.
• Safety Area Edge part may not be displayed in some modes.
25
Page 26
9. List of Compatible Signal Formats continued
9-2. Computer Signal (PC-RGB/DVI)
No Input Signal Names Screen Resolution VGA (PC-RGB) DVI Vertical Frequency
1 VGA 640*480 P P60Hz ~ 100Hz
2 SVGA 800*600 P P56Hz ~ 85Hz
3 XGA 1024*768 PP 86Hz ~ 100Hz
4 WXGA 1280*768 PP 50Hz ~ 85Hz
5 SXGA 1280*1024 PP 60Hz ~ 76Hz
6 WSXGA+ 1680*1050 PP 50Hz~60Hz
7 UXGA 1600*1200 PP60Hz Only
8 WUXGA* 1920*1080 PP60Hz
9 WUXGA 1920*1200 - P60Hz,( PC Only)
26
Page 27
10. Specifications
Function PBM-070/PBM-070X
INPUT HD/SD-SDI Input 1EA, HD/SD Serial Digital , 1.485G/270M ,BNC Jack
Analog Input 3EA,Composite,YC(S-Video),YPbPr,RGB,BNC Jack
PC-RGB(DVI) Input 1EA,DVI + Analog Jack (with gender) (24Pin + 5Pin)
DVI Input 1EA, DVI-I, 24pin, Female
OUTPUT SDI Output 1EA, BNC, Active Loop Output
ANALOG INPUT Composite (CVBS) 1.0Vp-p(with sync), NTSC/PAL
LEVEL YC(S-Video) Y :1.0Vp-p, C:0.286Vp-p
Component (Y/Pb/Pr) Y :1.0Vp-p, Pb :0.7Vp-p, Pr :0.7Vp-p
Component (R/G/B) G :1.0Vp-p(with Sync), B :0.7Vp-p, R :0.7Vp-p