Platinum Tools TFT100 Data Sheet

The only way to see why, when,
Fault Trapper
and where a circuit breaker trips!
See Beyond The Circuit Breaker
Stop guessing about circuit breaker tripping issues! For the rst time, you can detect the type of fault and locate the position of an electrical “event” that causes intermittent or persistent circuit breaker trips and No Fault Found (NFF) conditions, thus giving you the critical information needed to reduce call backs for circuit breaker trips.
The Fault Trapper is a new class of tester using Spread Spectrum Time Domain Reectometry (SSTDR) to monitor live circuits. Running on in-line power for extended battery life, it
captures time and distance to Opens, Shorts and Arc Faults saving the event information in memory for later investigation. The in-line 40 Amp Module isolates the circuit being monitored from the breaker panel and all other breakers. The last faults can be viewed off-line using the back-up battery.
Fault Trapper allows unattended monitoring of energized dedicated circuits for NFF conditions. Just set it up, press the
Test button to begin monitoring and walk away. Come back later or the next day to nd out the why-when-and-where’s of circuit breaker trips and NFF conditions.
Allows unattended monitoring to identify electrical events.
We Make Connections EZ!
• In-line monitoring of energized dedicated circuits up to 300 VAC and 40 amps
• Allows unattended monitoring of intermittent or sustained electrical events
• No Splicing – Plug in with existing wiring
• Identies opens, shorts and arc faults
• Detects the last event whether or not the breaker trips
• Runs on in-line power in monitor mode
• Fault location reported as distance from the Fault Trapper in feet/meters
• Easy-to-use three-button operation
• Backlit LCD display for dark areas
• Back-up battery allows capture of breaker trips/unpowered display of results
California, USA
Phone: 805.384.2777/800.749.5783
Fax: 800.749.5784
www.platinumtools.com
2016 Platinum Tools, All rights reserved
TFT100 Fault Trapper
Distance to fault
Flashes when
monitoring
Type of fault
Time since test started
Open Short
Voltage
ft m
See Beyond The Circuit Breaker
Physical Dimensions
Input Rating
Measurement units
Remaining battery
Icon on if fault tripped breaker
Measurement
Battery Use and Life
Specications
Fault Trapper Meter (Main Unit) Size: 15.25 x 7.6 x 3.8 cm (6.0 x 3.0 x 1.5 inches) Weight: 255 grams (9 oz.) With battery
In-Line 40 Amp Module Size: 11.5 x 7.6 x 5.85 cm (4.5 x 3.0 x 2.3 inches) Weight: 312 grams (11 oz.)
Fault Trapper Meter (Main Unit) 90 to 265 Volts AC RMS 50/60Hz, 4 Watts max.
In-Line 40 Amp Module 300 Volts AC RMS, 40 Amp circuits maximum supplies power to main unit
Method: Spread Spectrum Time Domain Reectometry (SSTDR)
Accuracy: +/- 10% of the reading Maximum Length: 300 ft on NM-B or Wire in Conduit
Used to view results when not AC powered Battery Low Level: Approximately 5.5 volts Battery Life (9 Volt alkaline battery, typical)
Standby Mode (Non-viewing): 2 years Active Viewing Mode: 4 hours typical
Ordering Information
Description P/N UPC Code
Fault Trapper Kit. Includes Banana Plug Assembly, Plug in Terminal Blocks and Insulated Screwdriver
TFT100 849160008057
We Make Connections EZ!
Environmental Temperature
Rating
Safety Compliance
Warranty
Operating: 0 to 50°C (32 to 122°F) Storage temperature: -20 to 60°C (-4 to 140°F) Long Term Storage w/ battery:
35°C maximum (95°F) Humidity: 10% to 90%, non-condensing Altitude: 2,000 meters (6,561ft) maximum
300V CAT III, 120/240Vac, 40 amps or less, single phase.
TüV-tested to UL 61010-1:2012, CAN/
CSA-C22.2 No. 61010-1-12
1 year
* Specications are subject to change without notication
California, USA
Phone: 800.749.5783
Fax: 800.749.5784
www.platinumtools.com
2016 Platinum Tools, All rights reserved
Fault Trapper 3.16