Platinum Tools TDG310 Users Guide

Page 1
TDG310K1C Digital Tone and Probe Kit
TDG310 Digital Tone and Probe Kit
User Manual
PLATINUMTOOLS_TDG310_MANUAL
Page 2
Table of Contents
Contents
Operating Instructions ...........................................................................10
Setup ................................................................................................10
1. General Cable Tracing ....................................................................10
2. Bundled cables ..............................................................................11
3. LED Signal Strength Indicators ......................................................11
4. Mapping Unknown Cables, Cable Faults and Wire Map Indicators .11
5. Connector Wiring and Short Circuit Detection ................................12
6. 2-Pair/4-Pair Indicator ...................................................................12
7. A Break in the Wire ........................................................................12
8. Use with PoE switches...................................................................12
Wire Map Detection ...........................................................................12
Cable Conguration Detection ...........................................................12
Network Cable Port Continuity Detection ...........................................13
Short circuit test ................................................................................14
Continuity Detection with Cables Connected to a Switch ...................15
PD (Powered Device) Emulation.........................................................15
Other Features ..................................................................................16
Specications ........................................................................................17
2 3
Page 3
SAFETY INFORMATION
FEATURES AND BENEFITS
This product is intended for use in compliance with the local electrical
safety rules and should not be used where electrical sparks may be exposed to ammable or explosive gases (gas stations, hospitals, etc.).
Use this product within operating temperature specications.
This product is only intended for low voltage testing up to 60 Volts.
Do not use this instrument for high voltage circuits. Doing so may damage the instrument or cause injury or death.
GENERAL WARNINGS
To retain functional integrity, keep this product dry and do not store it in
humid environments when not in use.
Remove batteries when not in use for extended periods to
prevent corrosion.
Do not expose the contacts of the connectors to moisture or dust.
Impacts, collisions and vibrations may cause damage to internal
components during transportation or use.
Avoid disassembling the instrument, as no component inside can be
repaired by the user.
This instrument is not intended to be used in environments with strong
electromagnetic interference.
The TDG310 Digital Tone and Probe Kit allows tracing and locating of single cables or bundles that are connected to unpowered or active networks such as phone lines, network cables or coax cables. The built-in test functions can verify proper network termination or test for shorts in the single-ended test mode. The tone generator can also determine the status modes of analog telephone lines.
Features
Trace and locate cables in unpowered or live circuits.
Includes audible and visual strength indicators.
Built-in testing capacity for RJ45 termination.
Equipped to test PoE ports for power and speed congurations.
Checks status of analog phone lines.
Comes with a built-in high-intensity ashlight.
Benets
Digital tone generation and detection rejects extraneous analog noise
to locate cables quickly and easily.
Trace and test cables in the same interface.
Identify cable types, including 2-pair or 4-pair, straight, cross or other.
Cable scan and continuity testing for UTP, STP, RJ45, and RJ11 cables.
Identify the status in the working telephone line: standby, ringing
or off-hook.
Quickly detect the near-end, mid-end and far-end cable faults.
The RJ45 port withstands a maximum voltage of 60VDC and the wire can
be traced directly to a powered PoE port.
Perform continuity tests on shielded cable and shielding layers.
PD powered detection detects whether the power output of the PoE switch
is normal and detects the pins used for the power supply.
Switch between Audible or Silent mode.
Work in the dark with the built-in high-intensity LED ashlight.
4 5
Page 4
Tone Generator
INTERFACES AND FUNCTIONSINTERFACES AND FUNCTIONS
1
2
3
4
5 6
1
Telephone status indicator
2
Functions switch: SCAN/UTP, OFF, UTP cable test
Category cable sequence, continuity and cable shielding
3
detection indicators
4
Category cable type indicators: straight, cross, other
5
2-pair / 4-pair indicator
6
Cable Shielding Indicator: Green-UTP (Unshielded), Red-STP (Shielded)
SET: Switches function between shielded and unshielded in cable
7
tracer mode and local, remote or switch in UTP cable test mode
8
Battery strength indicator
9
SWITCH connection indicator
10
LOCAL/Remote connection indicators
2-pr
10
9
8
7
11 12
13
11
BNC interface
12
RJ45 cable port
13
RJ11 port
Note: Please turn the tone generator OFF when testing the telephone line status. The STATUS indicator light ashing corresponds to telephone status (standby/ringing/off-hook).
6 7
Page 5
INTERFACES AND FUNCTIONSINTERFACES AND FUNCTIONS
Digital Probe
5
6
7
8
1
High-intensity LED Flashlight
2
Power Indicator
3
UTP Wire Map / Signal Strength Indicator
4
RJ45 Shield Indicator
5
Earphone Jack
6
RJ45 Test Port
7
LED Flashlight On/Off Switch
1
2
3
4
8
2-pair/4-pair Indicator
9
Switch/Sensitivity Knob
MUTE Button (long press for silent mode, short press for port con-
10
nectivity detection)
11
RJ45 Cable Type Indicator: straight, cross or other
Port Continuity Detection Indicator (ON indicates local end cable connectivity
12
function, OFF indicates cable sequence function)
9
10
11
12
PoE PD Powered Test Port (detects pin conguration of cable
13
and PoE type)
13
Note: Probe port continuity detection only tests the local end. The tone generator can support near end, middle end and far end port detection.
8 9
Page 6
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
Setup
Check the connector for proper termination, then insert the network cable into the tone generator’s RJ45 port, connect the BNC cable to the tone generator’s BNC interface or connect the RJ11 telephone line to the RJ11 port. If the cable is not terminated, use the alligator cable to clip the bare copper wires of the cable.
RJ45
2-pr 2-pr 2-pr
1. General Cable Tracing
Switch the tone generator to the “SCAN/UTP” mode, then press the “SET” key to switch to UTP/STP mode. The color of the “UTP/STP” LED indicates the instrument’s mode, with green for unshielded and red for shielded. Turn on and use the tone probe to trace the wire.
BNC
RJ12
2-pr
2. Bundled cables
The tone may bleed into the other cables of a cable bundle. Rotate the sensitivity knob of the probe to isolate and trace a specic cable if cables are closely routed or bundled.
3. LED Signal Strength Indicators
Press and hold the “MUTE” button for silent mode. In this mode, the signal strength indicator light is used to trace the wire. The stronger the signal, the more indicator lights are lit. Press “MUTE” again to exit the MUTE mode.
4. Mapping Unknown Cables, Cable Faults and Wire Map Indicators
To quickly locate or map the end of an unknown cable, insert one end of the cable in the RJ45 port in the tone generator,
12345678
then insert the other end of the unknown cable to the RJ45 port in the tone probe. If the “Straight/ Cross/Other” LED lights, this is the other end of the unknown cable. The indicator also shows if there are cable faults. The 1-8 and G indicators show the wire map sequence by default, and the order in which the indicator lights up is the sequence of the line. When connected to the cable, the probe indicator the cable status by sound: the “di” sound means connected pair lines, while the “du” sound means short circuit pair lines. All indicator lights of short circuit pairs are on at the same time.
10 11
Page 7
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
5. Connector Wiring and Short Circuit Detection
Press the “MUTE” button on the probe: when the indicator light of the port is lit, the 1-8 and G indicator lights show that the connection between the cable wires and the connector is continuous. For a single­ended shorts test, insert one end of the network cable into the RJ45 port of the probe, then press “MUTE”. If the “Port” LED is lit, there is a short circuit in the network cable.
6. 2-Pair/4-Pair Indicator
Connect the ends of the network cable to Switch and to the RJ45 port of the tone generator, then press the “SET” key to switch to the “SWITCH” mode. If the 1, 2, 3 and 6 indicators LEDs are lit, only 2 pairs in the cable or port are continuous. If all indicators 1-8 are lit, all 4 pairs of the cable or port are continuous.
7. A Break in the Wire
A tone that is not detected at the end of the cable may indicate a break in the wire(s). Trace the cable until the signal is not heard. This would indicate where the break is located. You may need to cut off the connector to trace the wires in a twisted pair cable individually with the alligator clip accessory.
8. Use with PoE switches
The RJ45 ports of tone generator and probe can withstand a maximum of 60VDC, the wire can be traced directly in connection with PoE switch.
Wire Map Detection
Cable Conguration Detection
Step 1: Insert the ends of the network cable into the RJ45 port of the tone generator and the RJ45 jack of the probe. Turn on the probe.
Step 2: Switch the tone generator to UTP mode. The 1-8 and G indicators will show the type of cable and the 2-pair or 4-pair indicators show the cable or port is continuous on wires 1, 2, 3 and 6 or wires 1-8.
Quickly determine the cable conguration through the tone generator or tone probe. If the Direct or Cross indicator is lit, the cable conguration is wired correctly according to TIA568A/B standards. Once the indicators
ash, the tone probe will beep to indicate the cable conguration. A single beep indicates a standard TIA568A/B congured cable, a double beep indicates a cross cable and a triple beep is a different or wrong conguration.
Network Cable Port Continuity Detection
In the UTP mode, press the “SET” key to switch to “LOCAL” mode.
Local Port (Near-End) Continuity Detection
When the “LOCAL” indicator LED is on, connect the other end of the network cable to the tone probe “UTP” port or disconnect the UTP port. The 1-8 and G lights indicate the near-end continuity status of network cable or ports within 1 meter of the tone generator.
In the picture shown, the 1st wire of the network cable port on the side of tone generator is disconnected.
12 13
Page 8
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
The 1st indicator light is off, indicating that the 1st wire of the port is not connected.
Remote (Far-End) Continuity Detection
While in UTP mode, press the “SET” key to switch to the “REMOTE” function. When the “REMOTE” indicator is lit, connect the other end of the cable to the UTP port of Probe. The REMOTE function in this case determines continuity faults within 1 meter of the probe.
The 1-8 and G LEDs indicate the continuity of the cable port connected to the probe. In the picture shown, the 5th wire of the cable port on the side of the cable tracer (probe) is open, so the 5th indicator in the 1-8 indicators is off.
Mid-Span Cable Continuity Detection
If the cable sequence detects an break in both LOCAL and REMOTE modes, the break point of the cable is mid-span away from the ports on both sides.
Short circuit test
When the cable is connected
6 and 7 wires are short-circuited
to just the tone generator and in SWITCH mode, the indicator lights of the shortened pairs will ash. The same is true if the cable is connected to just the probe in PORT mode. If both are connected, the indicator lights of the short-circuited pairs on both devices will ash.
14 15
Continuity Detection with Cables Connected to a Switch
While in UTP mode, press the “SET” key to change to the “SWITCH” function. When connected to a switch, the 1-8 and G indicator lights show the continuity of the cable: lights on means connected, lights off means disconnected, with the 1, 2, 3 and 6 lines indicating a 100M switch and all lines 1-8 indicating a 1000M. This mode can also detect the short circuit status of network cables. Simply connect one end of the cable to the RJ45 port of tone generator and the other end to the switch, then check the indicator light.
Switch
PD (Powered Device) Emulation
A
B
C
Power detected on pairs
C
1/2, 3/6, 4/5, & 7/8
Power detected on
A
pairs 4/5 & 7/8
1234 5678
Power detected on
B
pairs 1/2 & 3/6
Page 9
OPERATING INSTRUCTIONS SPECIFICATIONS
PD (Powered Device) Emulation
Connect a patch cable from the PoE switch or PSE power supply device to the “PD” port of the probe. If the indicator light is on, it means the port has been congured for PoE output and voltage is detected. There are 4 indicator lights on the “PD” port. When testing the pins used for power, if the 1, 2, 3 and 6 indicators are lit, the PoE port is supplying power through pairs 1/2 and 3/6. If the 4, 5, 7, and 8 indicators are lit, the PoE port is supplying power through pairs 4/5 and 7/8. If all indicators are lit, the PoE port is supplying through all four pairs 1/2, 3/6, 4/5 and 7/8.
This function is useful for checking the pins a PoE switch or other source is using to supply power, to avoid causing damage to a camera or other device.
Other Features
Line DC Level and Positive/Negative Polarity Testing
Using the BNC-to-Alligator clips cable, turn off the tone generator and clip the red and black wire clips to the telephone line or battery. Then, connect the cable to the BNC port of the tone generator. If the telephone cable is terminated with an RJ11 connector, connect the telephone cable to the RJ11 port instead.
If the indicator light is in green, that means the red wire clip is positive and the black clip is negative. If the indicator light is in red, the black is positive and the red is negative. The brightness of the indicator light also shows the level, with a brighter light indicating a higher level.
Item Digital Tone Generator and Probe Kit
Tone Generation Digital signal (rejects noise and false signals)
Cable types RJ45 Twisted pair, RJ11 telephone line, BNC cable, etc.
LED wire map, shielded cable and shielding continuity
UTP cable test
Continuity test of RJ45 cable connectors
PD (powered) test
LED lamp Short press On/Off LED light
Silent mode
Audio output Supports external audio output and mono earphone jack
Power Supply
External power supply
General
Operating Voltage Up to 60VDC between pins
Working Temperature
Working Humidity 30%-90%
Dimension and Weight
Tone generator
Probe
indicator, check cable type indicator: straight/cross/other, 2-pair/4-pair continuity test, triple zone short testing, UTP cable short circuit test
Detect the continuity of the pins on both sides of network cable and short circuits
PoE switch power supplying status test and check the pins used for power supply
Long press “Mute” button to switch silent mode, nd cable through LED strength indicators
Four AA batteries
-10c — +50c
152mm x 62mm x 27mm (6.0” x 2.4” x 1.1”)
0.12Kg (4.23 oz)
218mm x 48mm x 32mm (8.6” x 1.9” x 1.3”)
0.1Kg (3.5 oz)
16 17
Page 10
NOTES
18
Page 11
TDG310 Digital Tone and Probe Kit
User Manual
North Carolina, USA | 800.749.5783
platinumtools.com
PLATINUMTOOLS_TDG310_MANUAL