Platinum Tools 106220, 106230 Specsheet

Cat6A Flex Connector
90º Flex so cables hang vertically!
106230
The Cat6A Flex Connector makes Cat6A and
Cat7 terminations easier than ever. The unique patented design ensures top tier performance for Cat6A and Cat7 cabling. These connectors provide a low cost, easy termination solution with high performance and superior connectivity options.
Tool-less termination design
Minimal tools required for preparation
Accommodates Cat6A and Cat7 Cables up to
9.0mm and 26-22 AWG Conductors.
Works with both solid and stranded conductors
Machine-precision-set contact height
Frequency rated up to 1GHz
10-Gigabit certified
PoE+ rated
Flexible design:
- Can flex 90 degrees down
- Can flex 45 degrees up
- Allows the cable to hang vertically, eliminating bending and the need for strain reliefs
106220
We Make Connections EZ!
Shielded
Non-Shielded
Ordering Information
P/N Description UPC Code
106220 Cat6A Flex Connector, Non-Shielded 849160008316
106230 Cat6A Flex Connector, Shielded 849160008323
Patent information:
US patent: US008764476 Taiwan patent: I493808 TAA Compliant
See reverse for additional information.
California, USA
Phone: 805.384.2777 / 800.749.5783 • Fax: 800.749.5784
www.platinumtools.com
2016© Platinum Tools. All rights reserved. Cat6A Flex Connector PF 07/16 TS
Cat6A Flex Connector
Cat6A Flex Connector Termination Guide
1. Tools required: Flush cutters (PN 10531C), a cable jacket stripping tool (PN 15010C), and the flex connector.
2. Strip jacket and remove any pull cords or internal strength members. Shown is wiring for TIA568B. Cut Green and Blue pairs shorter for easier wire management.
3. Slide pairs into the connector orienting them according to the colors on the wiring guide. Seat the cable jacket up against wire guide.
4. Untwist pairs and align in the corresponding wire slots in the wire guide. The wires will seat into these guides and stay firmly in place.
5. Using flush cutters trim the excess wire flush with the connector wire guide ensuring all wires are in the correct slots.
1
2
3
4
Grounding the Cat6A Shielded Flex Connector:
10. The metal tab on the back end of the wiring guide is used for grounding the Cat6A Flex Connector. This tab can be used for either a drain wire as well as foil or braid.
11. The drain wire can be wrapped up around the divot in the tab. Hold the drain wire and wrap it around this tab 2-3 times making sure it is secure. Solder can be used if necessary.
12. For extra grounding and security this tab can also be inserted into the cable jacket to make contact with the foil or braid. The cable shown here shows both the drain wire and foil being used for grounding.
13. The above guide can be used for terminating both the shielded (PN 106230) and non-shielded (PN 106220) Cat6A flex connectors.
10
11
6. Once all conductors are cut flush you are ready for termination.
7. Fold over the wiring guide and press firmly to close. With larger conductors there may be some resistance and a set of pliers can be used to finish the termination.
8. Once connector is snapped closed, use the included cable tie to secure the cable jacket onto the connector. Insert through the slot on the back end and wrap around the cable jacket.
9. Cinch the cable tie tight and the termination is complete.