Platinum Access Systems BLSL3060 Installation Instructions & Owner's Manual

BLSL3060
BLSL3060 Manual_Layout 1 6/21/2015 10:44 AM Page 1
1
Installation Instructions & Safety Information Manual
BLSL3060
Vehicular Gate Operator
TA BLE OF CONTENTS
Gate Operator Class Categories & Example Protection Against Entrapment Use & Application Important Safety Instructions Maintenance Instructions Intended Use Types of Installations Mounting Instructions
Entrapment Protection Inductive Loops Alarm Reset Switch Warning Placards Electrical Limit Switches Primary/Secondary Connections Loop Rack Accessory Connections Selectable Features
Solar Installation Parts Diagram Gate Operator Trouble Shooting Procedure
....................................................2
....................................................3
....................................................4
....................................................5
....................................................6
....................................................7
.................................................8-9
.............................................10-12
..................................................13
.............................................14-15
..................................................16
.............................................17-18
.............................................19-20
..................................................21
..................................................22
.............................................23-26
.............................................27-28
..................................................29
..................................................30
.............................................31-32
BLSL3060 Manual_Layout 1 6/21/2015 10:44 AM Page 3
2
Gate operator class categories and examples
HOTEL
FACT ORY
DOCK
HANGAR 00
READ AND FOLLOW ALL INSTRUCTIONS MANUAL BEFORE ATTEMPTING ANY INSTALLATION
Residential Vehicular Gate Operator Class I
A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or a garage or parking area associated therewith.
Commercial/General Access Vehicular Gate Operator Class II
A vehicular gate operator (or system) intended for use in a commercial location or building such
DVDPXOWLIDPLO\KRXVLQJXQLW¿YHRUPRUHVLQJOH
family units), hotel, garages, retail store, or other building servicing the general public.
Industrial/Limited Access Vehicular Gate Operator Class III
A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public.
Restricted Access Vehicular Gate Operator Class IV
A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel.
BLSL3060 Manual_Layout 1 6/21/2015 10:44 AM Page 4
3
PROTECTION AGAINST ENTRAPMENT
Usage Class
Gate Operator Category
Horizontal Slide, Vertical lift, and Vertical Pivot
Swing and Vertical Barrier (arm)
Primary Type* Secondary Type* Primary Type* Secondary Type*
Vehicular I and II
Vehicular III Vehicular IV
A
A, B1, or B2
A, B1, B2, or D
B1, B2, C, or D A, B1, B2, C, D, or E A, B1, B2, C, D, or E
B1, B2, or D A, B1, B2, D, or E A, B1, B2, D, or E
A, or C
A, B1, B2, or C
A, B1, B2, C, or D
Note - The same type of device shall not be utilized for both the primary and the secondary entrapment protection means. Use of a single device to cover both the opening and closing directions is in accordance with the requirement; however, a single device is not required to cover both directions. A combination of one Type B1 for one direction and one Type B2 for the other direction is the equivalent of one device for the purpose of complying with the requirements of either the primary or secondary entrapment protection areas.
a
Entrapment protection Types:
Type A: Inherent entrapment protection system.
Type B1: Provision for connection of, supplied with, a non-contact sensor (photoelectric sensor
or the equivalent).
Type B2: Provision for connection of, or supplied with, a contact sensor (edge device or the equivalent)
Type C: Inherent adjustable clutch or pressure relief device.
Type D: Provision for connection of, or supplied with, an actuating device requiring continuous pressure to
maintain opening or closing motion of the gate.
Type E: An audio alarm.
BLSL3060 Manual_Layout 1 6/21/2015 10:44 AM Page 5
4
Use and Application
The model BLSL3060 is intended for Class I, II, III and IV usage on a vehicular slide gate application.
a) Install the gate operator only when:
1) The operator is appropriate for the construction of the gate and the usage Class of the gate,
2) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.22 m) above the ground to prevent a 2-1/4 inch (57.2 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position,
3) All exposed pinch points are eliminated or guarded, and
4) Guarding is supplied for exposed rollers.
b) The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with
a separate access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.
c) The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent
structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas.
d) The gate must be properly installed and work freely in both directions prior to the installation of the gate opera-
tor. Do not over-tighten the operator clutch or pressure relief valve to compensate for a damaged gate.
e) For gate operators utilizing Type D protection:
1) The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving,
2 The placard equivalent to the following: “To reduce the risk of electric shock the operator power is to be
provided from a weatherproof outlet in the case of attachment plug connection or weatherproof junction box in the case of permanent wiring according to the National Electrical Code, NFPA 70.” shall be placed adjacent to the controls,
3) An automatic closing device (such as a timer, loop sensor, or similar device) shall not be employed, and
4) No other activation device shall be connected.
BLSL3060 Manual_Layout 1 6/21/2015 10:44 AM Page 6
5
Important Safety Instructions
WARNING – To reduce the risk of injury or death:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Never let children operate or play with gate controls. Keep the remote control away from children.
3. Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.
4. Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of injury or death.
5. Use the emergency release only when the gate is not moving.
repairs to gate hardware.
7. The entrance is for vehicles only. Pedestrians must use separate entrance.
8. SAVE THESE INSTRUCTIONS
Maximum Gate Weight: 3000 lbs. Maximum Gate Length: 60 feet Opening Time: 12" per second Power Requirements: 120 VAC Single Phase at 2 Amps or 220 VAC Single Phase at 1 Amp Main Power: Power Input: 100-240 VAC Select 115 /230 VAC Single Phase Built-in 24VDC battery backup
(33AmpHr 12VDC x 2)
Operating Temperature: -20°C (-4°F) to 70°C (158°F) Operator Weight: 210 lbs.
Operator Dimensions:
SPECIFICATIONS
25 1/2
24
15
1
/
2
BLSL3060 Manual_Layout 1 6/21/2015 10:44 AM Page 7
6
Maintenance Instructions
Maintenance instructions of BLSL3060 performed by a qualified gate operator technician Installation, all connections, programming, repair and modifications must be done by a qualified professional gate operator installer.
Maintenance instructions of BLSL3060 performed by the end user/home owner
The following services need to be periodically performed:
• Check and adjust the gate operator for force, speed, and sensitivity.
• Make sure all power (AC/DC ) connections are corrosion free.
• Check all batteries for proper voltage of the intended use. A fully charged battery must be 26 VDC minimum.
&KHFNWKHLQFRPLQJOLQHYROWDJHDQGFRQ¿UPLWLVZLWKLQRILWVUDWLQJRUYROWV
• Verify battery backup functionally by turning off the power source (115 VAC and 230 VAC). Don’t forget to restore power after testing.
• Check the wheels, guide rollers, chain, and lubricate where needed with a heavy-duty, highperformance lubricant and avoid spillage.
• Inspect the track for any signs of cracking or separation.
• Test (use caution) all contact and non-contact sensors, all vehicle detectors, keypad, telephone entry system or other control devices applicable.
• Test the manual release feature on the operator.
,QVWDOODWLRQDOOFRQQHFWLRQVSURJUDPPLQJUHSDLUDQGPRGL¿FDWLRQVPXVWEHGRQHE\DTXDOL¿HGSURIHVVLRQDO
JDWHRSHUDWRULQVWDOOHU(QGXVHUVKRPHRZQHUVPXVWFDOODTXDOL¿HGSURIHVVLRQDOJDWHRSHUDWRULQVWDOOHUIRU
SURJUDPPLQJFKDQJHVUHSDLUVDQGPRGL¿FDWLRQV
Although all Platinum Access Systems’ gate operators are virtually maintenance free to an end user/home own minimal maintenance is recommended to ensure a smooth operation of this unit.
End users/home owners:
• Perform maintenance every six months, or when strenuous noise from wheels and/or guide rollers is detected. Lubricate them with heavy-duty, high-performance lubricant and avoid spillage.
• DO NOT take the cover off the operator and/or the electrical control box to perform maintenance.
• Make sure there are no cars in the path of the gate while performing maintenance.
• Make sure the person performing maintenance is the only person in control of all control devices in order to avoid possible involuntary activation of the gate operator.
• Keep spraying water hoses and sprinkler systems away from the gate, gate operator and the electrical control box at all times. Keep that general area as clean as humanly possible.
• Test (use caution) all non-contact sensors, all vehicle detectors, keypad, telephone entry system or other control devices applicable.
BLSL3060 Manual_Layout 1 6/21/2015 10:44 AM Page 8
7
Intended Use
The operator is intended for installation on a vehicular slide gate only.
The operator IS NOT intended to be used for any pedestrian gate.
BLSL3060 Manual_Layout 1 6/21/2015 10:44 AM Page 9
8
Types of Installations
FRONT INSTALLATION
Gate Operator
Open Position Closed Position
Gate Operator
Concrete Pad
Track Concrete Pad
BLSL3060 Manual_Layout 1 6/21/2015 10:44 AM Page 10
9
Types of Installations
REAR INSTALLATION
Gate
Safety Guard Fixed Pulley
Route Chain As Shown
etail of Rear Install ain Rote
Gate Operator Concrete Pad
Gate Operator
Concrete Pad
Gate
Operator
Open Position Closed Position
Track Concrete Pad
See Detail Below
Parts Not Supplied by
Platinum Access Systems
BLSL3060 Manual_Layout 1 6/21/2015 10:44 AM Page 11
10
Mounting Instructions
CONCRETE PAD
1.
Follow the local building code to determine the requirement of the concrete pad.
2. We recommend the Pad measurements should be at least 28
"
long, 20" wide,
and 24
"
deep to ensure the stable operation of the operator, and a minimum
of 4
"
above level grade to avoid any flooding of the operator.
3. To support the weight of the gate, we recommend the path of the track should be at least 10
"
wide and 6" deep.
Drill for a 1/2" x 31/2" Red Head Anchor (4) Places
20"
24"
10"
6”
Track
2"
9
1
/4"
Minimum
4"
Minimum
28"
203/8"4"
Gate Operator Concrete Pad
Gate Operator Concrete Pad
Install a Positive Stop at Both Ends of the Track
Operator Cover
Track Concrete Pad
Track Concrete Pad
Gate
Grade Level See Note 2
Operator Chassis
127/8"
Chain
6"
BLSL3060 Manual_Layout 1 6/21/2015 10:44 AM Page 12
Loading...