Platinum 22000 tl, 19000 tl, 13000 tl, 16000 tl Installation And Operating Manual

Page 1
Installation and Operating Manual
INVERTER TL
Mat. No. 737 576-AB, Version 05/2010
Page 2
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Thank you for buying a PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL.
In this instruction, we have compiled all information that is important for installation and operation.
If you still have any trouble, please call our service hotline.
Service hotline
You can reach the PLATINUM service hotline as follows: Phone +49 7522 73 777 Fax +49 7522 73 737 E-Mail service.platinum@diehlako.com
2
Page 3
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
1 Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1.1 Warning notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1.2 Other symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.3 Symbols on the product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
2 Safety and Dangers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
3 Intended Use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
4.1 Variants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
4.2 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5 Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
5.1 Scope of delivery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
5.2 Transport. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
5.3 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
5.4 Mounting the inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
5.5 Connection of the inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
6 Start Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
6.1 Initial startup of inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
6.2 Phase Balancer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
6.3 Replacing devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
7 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
7.1 DC disconnector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
7.2 Display and operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
7.3 Standard screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
7.4 Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
7.5 Operating Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
7.6 Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
7.7 Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
7.8 Error display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
8 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
8.1 Service Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
9 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
9.1 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
9.2 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
10 Placing out of operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
10.1 Dismounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
Installation and operating manual:PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
3
Page 4
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
11 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
12 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
12.1 Table of events. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
13 Standards and Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
14 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
15 EC Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
16 Manufacturers Warranty of Diehl AKO Stiftung & Co. KG . . . . . . . . . . . . . . . . . . . . . . . . . . 89
4
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
Page 5
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
1Symbols
1.1 Warning notices
Classification of warning notices
The warning notices differentiate between three types of dangers indicated by the following signal words:
Î Caution warns of material damage. Î Warning warns of bodily harm. Î Danger warns of a danger to life.
Layout of the warning notices
Type and source of the danger!
 Action to avoid the danger.
Signal words
Symbols
1.2 Other symbols
Instructions
Layout of instructions: Â Instruction to do something.
Result of the action, if necessary.
Lists
Layout of bulleted lists:
Î List level 1
t List level 2
Layout of numbered lists:
1. List level 1
2. List level 1
2.1 List level 2
2.2 List level 2
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
5
Page 6
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Symbols
1.3 Symbols on the product
6
Page 7
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
2 Safety and Dangers
 Use inverters according to their intended use.  Use inverters in original and technically fully intact condition
without unauthorized modifications.
 Ensure that inverters are installed and serviced by qualified
specialists only.
t The qualified specialist personnel requires a license from the
relevant energy suppliers.
 Always mount inverters in a vertical position.  Ensure that all protection devices are fully operational.  Verify that ventilation openings are not blocked or covered.  Protect inverters from direct sunlight.  Prior to installation and maintenance work, make certain that the
inverter is de-energized.
 Ensure that regulations stipulated by trade associations and
inspection authorities and agencies are observed and that the connection conditions of the relevant energy supplier or equivalent national and international rules and regulations are adhered to.
 Observe conditions of use (see 14 Technical Data).
Safety and Dangers
3 Intended Use
 Use the inverter exclusively to feed photovoltaically converted
solar energy into the public 230 V/50 Hz mains.
 Do not use the inverter in autonomous power systems.  Do not use the inverter in vehicles.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
7
Page 8
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Function
4Function
4.1 Variants
The PLATINUM line includes the following variants with different power ranges (see 14 Technical Data):
Î PLATINUM 13000 TL Î PLATINUM 16000 TL Î PLATINUM 19000 TL Î PLATINUM 22000 TL
Possible types:
Î wall-mounted device Î free-standing device Î free-standing device, outside
4.2 Options
Upgrades for an inverter or an inverter system:
Î Inverter networking via PLATINUM network (EIA 485 bus) Î Optical and acoustical indicator (warning) devices. Î Remote monitoring or remote readout with PLATINUM
WebMaster
Î Central display of systems with PLATINUM ViewMaster Î Evaluation of system data with PLATINUM PV-Monitor Î Remote control of AC power in connection with PLATINUM
PowerCommander, PLATINUM WebMaster and a control device on the mains supply side.
8
Page 9
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
5Mounting
5.1 Scope of delivery
Wall-mounted device:
Î PLATINUM inverter with protector Î Mounting fixture Î Installation and operating manual
Free-standing device:
Î PLATINUM inverter preassembled in Power Block protective
housing TL Large
Î Power Block protective housing Î Protector Î Installation and operating manual
Free-standing device, outside:
Î PLATINUM inverter with protector preassembled in Power Block
protective housing with protective cover and protective grate
Î Installation and operating manual
Mounting
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
9
Page 10
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Mounting
5.2 Transport
Danger to life due to inverter dropping from the wall!
 Transport packaged inverter exclusively with a forklift
truck and on a transport pallet.
Danger
Transport with lifting gear
 Load thread on inverter exclusively in longitudinal direction.  Ensure that carrying straps or ropes are at least 2 m long.
- or -
 Use yoke.
 Do not tilt inverter.  Transport inverter exclusively with lifting gear.
1
Fig. 1 Transport with lifting gear
 Screw DIN 580 M10 eyebolts into threaded holes 1 on inverter.  Fasten lifting gear on eyebolts.
Note
10
Eyebolts are not included in delivery.
2
(1) Threaded holes for transport eyebolts (2) Recessed grip
Page 11
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
5.3 Unpacking
Unpacking the wall-mounted device
Mounting
1
2
3
4
Fig. 2 Unpacking the wall-mounted device
(1) Upper part of packaging (2) Wooden protection elements (3) Bottom part of packaging (4) Transport pallet
 Put transport pallet 4 with inverter on even ground.  Remove upper part of packaging 1.  Lift inverter out of bottom part of packaging 3.
Use wooden protection elements 2 for carrying.
 Take inverter to installation site.
On installation site: Â Unscrew wooden protection elements 2 from inverter.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
11
Page 12
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Mounting
Unpacking the free-standing device
1
Fig. 3 Unpacking the free-standing device
(1) Transport pallet
 Take inverter to installation site on transport pallet 1.  Put transport pallet with inverter on even ground.  Remove plastic protective packaging.  Put inverter on intended installation site.
12
Page 13
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
5.4 Mounting the inverter
Danger to life due to electric shock!
 Have the inverter opened exclusively by the
PLATINUM service or service partners authorized by
Danger
Danger
Danger
DIEHL AKO.
Danger to life due to incorrect connection of inverter!
 Have inverters installed by qualified specialists only.
The qualified specialist personnel requires a license from the relevant energy suppliers.
Danger to life due to inverter dropping from the wall!
 Use mounting elements appropriate for the mounting
wall and the weight of the inverter unit.
During mounting and dismounting:
 Wear protective shoes.  Ensure a stable position.
Mounting
Material damage due to unprotected installation site!
 Observe admissible ambient temperature.
(see 14 Technical Data).
Caution
Material damage due to excessive dust formation!
 PDegree of protection IP65 does not apply to
communication interface.
Caution
 Avoid excessive dust formation.  Avoid dust formation with electrically conductive dust
particles.
DIEHL AKO advises against installing the inverter in living spaces.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010
Mat. No. 737 576-AB
Note
13
Page 14
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Mounting
Protector
1
Fig. 4 Removing protector
(1) Protector
For versions with protector, prior to installation of inverter:
 Hold protector 1 on bottom side and pull away from inverter.
14
Page 15
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting of wall-mounted device
Mounting
1
> 500
> 500
³ 258
³ 208
525
³
³ 204
2
Fig. 5 Spacing for position of mounting fixture (indications in mm)
(1) Mounting fixture (2) Ventilation openings (3) Slotted piece for mounting bolts (4) Mounting bolts (5) Grip moldings
Mounting fixture
3 1
4
5
Install the mounting fixture as follows:
 Unscrew mounting fixture 1 from the back of the inverter.  Mark the mounting holes using the mounting fixture as a
template.
t Observe dimensions and distances. t Observe a minimum distance of 50 cm between inverter and
floor.
t Observe a minimum distance of 50 cm between inverter and
ceiling.
 Drill the mounting holes and insert the screw anchors.  Bolt down mounting fixture 1.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
15
Page 16
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Mounting
Inverter
> 500
³ 150
743
> 500
> 500
262
³ 150
Fig. 6 Spacing for mounting of inverters (indications in mm)
Mount inverters as follows:
 Observe a minimum distance of 50 cm to the floor.  Observe a minimum distance of 50 cm to the ceiling.  Slide cooling element of the inverter into the mounting fixture 1.  Hold the inverter on recessed grips 5 and push up until mounting
bolts 4 drop into slotted pieces for mounting bolts 3 on both sides.
 Let down the inverter.
Mounting bolts 4 are seated in the slotted pieces.
 Verify that minimum distances are kept (see Fig. 6).  Verify that the inverter is hanging in the mounting fixture
16
correctly.
Page 17
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting of free-standing device
Mounting
1
Fig. 7 Mounting of free-standing device
(1) Power Block protective housing TL Large
 Put inverter in intended position.  Secure inverter against toppling over and shifting with screws in
base of Power Block protective housing TL Large 1.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
17
Page 18
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Mounting
5.5 Connection of the inverter
Note
Terms relating to the alternating voltage side will be combined with AC below. Terms relating to the direct voltage side will be combined with DC below.
Danger to life due to high AC voltage!
 Switch off the mains power supply (AC side) before
connecting the inverter (fuse).
Danger
Danger
 Connect inverter exclusively to TN or TT mains
(see IEC 60364-1) with 230 V.
 Maximum allowed fuse on alternating voltage side:
40 A, C-characteristics.
Danger to life due to high DC voltage!
 Prior to connecting the inverter, verify that voltage is
applied to the generator-side DC terminal.
 Prior to connecting the inverter, verify that the DC
voltage polarity is correct.
 Wear insulating protective clothing and face
protection if there is voltage present at the DC input.
 Remove DC cable exclusively if inverter is out of
operation.
18
Caution
Caution
Risk of burns due to hot surfaces!
After a longer operation with high power, housing temperatures of > 60 °C are possible.
 Do not touch hot surfaces.
Material damage due to DC plug connectors that don’t fit!
 Use exclusively DC cable connectors and DC
receptacles of the same type and manufacturer.
 Make sure that cable connector in latched in socket
correctly.
Page 19
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Caution
Caution
Mounting
Lack of performance and functionality due to inappropriate cables!
 Ensure that wire cross sections and fuses conform to
VDE 100 Part 430.
 Ensure that any network cables between two
inverters are not longer than 30 m.
 Ensure that network cable of entire PV plant is not
longer than 1,000 m.
 For DC lines, use a wire cross section of at least
2
2.5 mm
 Ensure that admissible power dissipation of mains line
is not exceeded.
Material damage due to excessive voltage!
 Ensure that the max. DC voltage is not exceeded
(see 14 Technical Data).
 Connect exclusively safety extra low voltage on the
contact of the external indicator.
.
For free-standing devices, the possibilities for cable routing through Power Block protective housing TL Large are as follows:
Î from front Î from below Î from back
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010
Mat. No. 737 576-AB
19
Page 20
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Mounting
Terminal side
11 2
7
4
3
Fig. 8 Terminal side inverter
6
4
3
(1) Control unit (2) Holder for installation and operating manual (3) Fan (4) Switch knob DC disconnector (5) Cover of AC voltage connection (6) Bushing for AC voltage cable (7) Type plate
4
35
20
Page 21
AC terminal
Caution
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting
Creation of inadmissibly high unbalanced load!
AC power varies along with DC power.
 Observe maximum admissible unbalanced load of AC
side.
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL feed on all three phases of the mains connection.
1
2
Fig. 9 Cover of AC voltage connection
(1) Mounting screws for cover (2) Cover of AC voltage connection
Note
Establish AC voltage connection as follows:
 Loosen mounting screws 1.  Open cover of AC voltage connection area 2.  Put cable through bushing for AC voltage connection cable.
Suitable for cable diameters between 12 and 21 mm.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
Note
21
Page 22
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
123
4
5
6
7
Mounting
Fig. 10 AC terminal
Note
(1) PE (2) N (3) L1 (4) L2 (5) L3 (6) Release opening (7) Cable input
To connect the cables:
 Use lines matching the type-dependent AC.  Fuse lines accordingly.
Max. fuse: 40 A, C-characteristics.
 Stick screwdrive in release opening 6 and press release.  Push cable into cable input 7 as far as it will go.
Ensure that no uninsulated cable parts are visible.
 Unlock release.  Pull out screwdriver.
Clamp suitable for single-wire (rigid) lines with line diameter of 2.5 to
2
10 mm 6mm
or multi-wire (flexible) lines with line diameter of 2.5 to
2
.
22
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
Page 23
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
To guarantee degree of protection IP65:
 Use a seal between cover and housing.  Ensure that joint is undamaged.  Ensure that no cables are trapped between cover and housing.
When the AC voltage connection is completed: Â Fixate AC cables with screw connection of bushing for AC
voltage connection cable.
 Close cover of AC voltage connection area.  Fasten cover with screws.
Mounting
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
23
Page 24
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Mounting
DC voltage connection
4
12
1 2
Fig. 11 DC voltage connection
3 4
(1) DC disconnector (2) DC terminal ­(3) DC terminal + (4) Fan
31 4231
Note
Note
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL are equipped with three MPP trackers working separately, with three connection areas for direct voltage.
 Distribute strings of PV generator among the three areas so that
t there are the same module types with the same horizontal
orientation and vertical tilt and approximately the same DC power connected in every area.
t there is no electrical connection between the three areas.
 Allocate DC connectors within the same area in pairs (+ and -).
It is possible that DC powers of different connection areas differ.
Establish DC voltage connection as follows: Â Establish a connection to the solar panel on the DC input with a
cable with a DC plug connector.
 Use exclusively DC cable connectors and DC receptacles of the
same type and manufacturer.
 Make sure that cable connector in latched in socket correctly.  Put protective caps on unused plug connectors.
24
Page 25
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Connection to PLATINUM network
Mounting
1
Fig. 12 Layout of network terminals
2
3
4
(1) Terminal strip (2) Twist-on connector for PLATINUM network (EIA 485) (3) Nwtwork connector for PLATINUM network (EIA 485) (4) Connection diagram for terminating resistor (5) PC interface to EIA232 (exclusively for service purposes)
It is possible to connect up to 50 PLATINUM inverters.
5
Note
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
25
Page 26
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Mounting
Terminal strip connectors
Note
Fig. 13 Layout of terminal strip connectors
11 2 3 4 5 6 7 8910 11 12
(1) Alarm contact (break contact) (2) Alarm contact (center contact) (3) Alarm contact (NO contact) (4) not allocated (5) Input, max. 12 V (option) (6) Supply voltage for ext. consumer 12 V,
max. 300 mW (7) Supply voltage for ext. consumer 0 V, (8) Shielding EIA485 (RS485) (9) Line A for PLATINUM network (EIA 485) (10)Line B for PLATINUM network (EIA 485) (11)Line A for PLATINUM network (EIA 485) (12)Line B for PLATINUM network (EIA 485)
Terminal strip is protected through cover. Opening the cover is possible without tools.
DIEHL AKO recommends to use connectors of EIA485 bus line on terminal strip as follows:
Î For incoming line pair:
t connector 9 t connector 10
Î For outgoing line pair:
t connector 11 t connector 12
26
Page 27
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Connection for PLATINUM network (EIA 485)
12111
Fig. 14 Network layout
(1) Termination option for engaging the terminating resistor (2) PLATINUM network (EIA 485)
Material damage due to interchanged lines!
 Ensure that lines A and B are allocated correctly.  Use exclusively CAT-5 cables with twisted lines and
Warning
Establish connection to network as follows:
shielding.
Mounting
 Establish connection between inverters or inverters and
monitoring devices on serial interface EIA485 using a cable with RJ45 plugs or cable on terminal connector (connection A and B) (see Fig. 12).
 For lines without RJ45 plugs, connect lines A and B in RJ45 plugs
on connectors A and B.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
27
Page 28
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Mounting
Fig. 15 Termination plug
It is possible to engage the integrated terminating resistor on both open ends of the network.
Note
The termination plug is clamped into the inside of the protector and fixated with a sticker labelled Netzwerk Terminierungsstecker / Network Termination Plug.
On first and last inverter in PLATINUM network:
 Plug termination plug into slot for network connection 1.
Alarm contact
 Connect any external indicator device to the potential-free
contact.
t When an error is detected, the contact is closed and
activates the indicator device (optical or acoustic warning).
t Setting: see menu Settings t function Alarm contact
 Only use safety extra low voltage (SELV) of max. 24 V as supply
voltage.
28
Page 29
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Mounting protector
1
2
3
Mounting
Fig. 16 Mounting protector
(1) upper part of protector (2) upper fixture (3) lower fixture
 Put upper part of protector 2 on upper fixture 1 and slightly push
down housing.
 Slide bottom part of protector in lower fixture 3.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
29
Page 30
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Mounting
Locking protective cover
For the free-standing device for outside installation, a protective cover provides additional protection from rain, sunlight and theft.
1 2
3
Fig. 17 Free-standing device for outside installation
(1) Protective cover (2) Protective grate (3) Power Block protective housing TL Large
 Make closed protective cover snap into place by pressing.
To lock open protective cover in position:
 Open protective cover as far as it will go.  Push protective cover to the left.  Lower protective cover until protective cover snaps into place.
To close protective cover locked in position:
 Lift protective cover as far as it will go.  Push protective cover to the right.  Close protective cover.
It is possible to lock the protective cover as a protection from impermissible access.
30
Page 31
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
2
1
Fig. 18 Locking protective cover
(1) Opening for locking
(2) Protective cover To lock protective housing: Â Thread cable rope or similar (max. Diameter 13 mm) through
designated holes 1 in bottom of cover and in Power Block protective housing.
 Secure cable rope or similar with lock.
Mounting
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
31
Page 32
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Start Up
6 Start Up
Note
Note
Independent of demand, the inverter activates the fan as soon as power input is started (e.g. every morning). When feeding in, the inverter activates the fan as required.
During the startup, several basic settings such as language selection, date and time settings are set. Information on display and operation see 7.2 Display and operation.
In order to transfer all settings correctly, it is necessary to do one complete startup.
If several inverters are installed which are networked via the EIA 485 interface, the startup can be carried out at any one of the installed inverters (master programming). This inverter transmits the configuration settings to all other inverters in the network. Every inverter is automatically assigned a number at its initial startup. The free allocation of this number is possible in a further step.
The inverters that are not used for input entries display other screen contents depending on the menu. If no entry is possible, the inverter shows the start screen.
Start screen
If any input has been entered in the inverter, the inverter shows the start screen after a restart.
All inverters that are not operated during the configuration will show the blocking screen.
Note
If parameters of the inverter have been adapted to special requirements of the energy supplier, this is indicated on the start screen.
32
Page 33
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
After changing parameters, the inverter shows the following screen:
6.1 Initial startup of inverter
Lack of function due to missing setting!
 Adjust Phase Balancer settings within 4 hours after
startup of inverter (see 6.2 Phase Balancer).
Caution
Setting at a later time is no longer possible.
 Reconfigure country code within four hours after star-
tup of inverter. Setting at a later time is no longer pos­sible.
Start Up
 Switch on the main power supply (fuse). For inverters with DC disconnector:  Set switch knob to 1. The inverter is supplied with power. Configuration through the
following dialogs.
Initial startup
Key Function
OK Start configuration process with this inverter.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
33
Page 34
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Start Up
Language selection
Key Function
ST
OK Accept selected language.
Select language.
After the configuration process has been started:
Î the inverter scans the network connected by the EIA485-Bus for
other inverters.
Î all inverters connected to the network are blocked.
EIA485 bus
As long as the network scan (Scanning Network) is still in process, the display shows the following screen:
When the network scan is completed, the display shows the number of detected bus participants. In case of a single inverter, the display shows 01.
34
Page 35
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
The network scan can only recognize more than 1 inverter if the inverters are correctly networked via the EIA 485 interface.
If the number of detected bus participants (e.g. inverters, data loggers, etc.) does not agree with the installation:
 Check connections (EIA 485 interfaces) if required.  Select REPEAT.  Press OK key.
If the number of detected bus participants is in agreement with the installation:
 Select OK.  Press OK key.
In case of a single inverter:
Î Screen Country Code appears.
Note
In case of several networked inverters:
Î Screen Inverter numbering appears.
If one or several inverters have been replaced or not all inverters are numbered correctly, this can be corrected (see 6.3 Replacing devices).
Inverter numbering
It is possible to network several inverters via the EIA 485 interface. Inverter numbers are allocated automatically during the network scan. The inverter number is displayed in the lower left corner of the screen.
For a clearer overview, the inverters can be re-numbered for specific requirements. For instance, the inverter number can be defined according to the installation sequence.
the middle one no. 2 and the right-hand one no. 3.
The following screen is not displayed if only one inverter is configured.
Note
ExampleWith three inverters installed, the left-hand one is allocated the no. 1,
Note
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
35
Page 36
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Start Up
Screen Inverter numbering:
Key Function
Note
WX
OK Confirm selection.
YES = Allocate user-defined number to inverter. NO = Accept inverter number unchanged.
If NO was selected:
Î The inverter adopts the displayed number und switches to the
Settings Date screen.
If YES was selected:
Î The display shows the following screen.
The following screen is not displayed if only one inverter is started up.
Key Function
OK The inverter adopts the next available number.
After OK was selected: Â Allocate numbers to inverters in the required sequence.
Example As soon as the OK key was pressed at the first inverter, this inverter is
allocated no. 1, which is shown on the display. When the OK key was pressed at the second inverter, this inverter is allocated no. 2, etc..
36
t The inverter adopts the next available number. t The display shows the screen below.
Page 37
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
The following screen is not displayed if only one inverter is started up.
Î Entry only at one inverter. All inverters connected to the network
are blocked.
Î With the number allocation completed, the inverter switches to
the Country Code screen.
Country code
In the menu Country code, the country where the inverter is operated is set. Country-specific net conditions are set automatically in dependence on the selected country.
The setting can be changed within 4 hours after the setting and the start of the feeding into the mains supply. Without feeding, the period is prolonged. After the period has expired, the setting cannot be changed anymore.
Note
Note
Key Function
ST
OK Accept selection.
Select country.
To select country code:
 Select desired country.  Press OK key.
The inverter automatically transmits the country code setting to all network participants.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010
Mat. No. 737 576-AB
37
Page 38
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Start Up
After the transmission is successfully completed, the inverter shows the selected country setting.
Note
If an inverter is replaced, only the country code of the replaced inverter can be changed.
Date
Key Function
ST
WX
OK Accept date setting.
Increment or decrement present digit.
Select next or previous digit.
38
Page 39
Time
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Start Up
Key Function
ST
WX
OK Accept time setting.
Increment or decrement present digit.
Select next or previous digit.
Changing date or time can result in overwriting saved data or cause gaps in data recording.
To accept time setting:
 Select SELECT.  Press OK key.
The inverter automatically shares the new time setting with all network participants.
Note
To rese t t ime:
 Select BACK.  Press OK key.
After setting the time, the configuration (language, date and time) are automatically transferred to all other inverters in the network (if available).
After the data transmission, the inverter will show the menu Time settings (see 7.6 Settings).
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
39
Page 40
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Start Up
6.2 Phase Balancer
An unbalanced load ist he difference between the nominal AC power on the three mains phases.
The energy provider and the power plant operator determine the admissible maximum unbalanced load for the installation of inverters on different phases of the supply mains.
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL are equipped with three inverter modules, each of which feeds AC power on a mains phase.
The Phase Balancer function makes sure that the admissible maximum unbalanced load is not exceeded.
Î Failure of an inverter module Î different AC powers occurring in dependence of the load
It is possible to set the admissible maximum power (unbalanced load) and the reaction time according to the specifications of the power plant operator (see 8.1 Service Menu).
6.3 Replacing devices
If one or more PLATINUM inverters in a PV system are replaced by another device, it is possible to transfer the device numbers of the replaced inverters.
During the network scan, the inverter automatically identifies any replaced devices.
It is possible to either use the old device numbers for the substitute devices or renumber the devices.
If inverters without a device number or doubly allocated device numbers are detected during the network scan, it is possible to correct this by renumbering them.
Display and operation are confined to the replaced inverters. All other inverters show the start screen.
40
Page 41
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
To accept device numbers of replaced inverters: Â Select EXCHANGE INVERTER. To renu m b er:
 Select REASSIGN NUMBERS.
Replacement of devices
After EXCHANGE INVERTER was selected, the replaced inverters show the following screen:
Key Function
Start Up
WX
OK Accept selected device number.
Select device number.
On every replaced inverter:
 Select desired device number.  Press OK key.
Inverter does another network scan.
The inverter automatically transmits the device numbers to all other inverters.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
41
Page 42
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Start Up
Inverter is added to PLATINUM network. Inverter shows main menu. Inverter shows device number of the replaced device in the lower left corner.
After device replacement: Â Set date and time.
Reassign numbers
 Reassign numbers see 6.1 Initial startup of inverter.
42
Page 43
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
7 Operation
7.1 DC disconnector
Operation
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL have a separate DC disconnector at each of the three DC inputs.
The DC disconnector enables switching on and off the solar generator.
To engage the solar generator: Â Set DC disconnector to 1 for all three connection areas.
To switch off the solar generator: Â Set DC disconnector to 0 for all three connection areas.
DIEHL AKO recommends to actuate the DC disconnector once a year to prevent the welding of contacts.
DIEHL AKO recommends to switch off the mains voltage (AC) before switching off the DC disconnector to minimize wear and tear of the contacts.
Note
Note
Fig. 19 DC disconnector
(1) DC disconnector
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
1
43
Page 44
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Operation
7.2 Display and operation
Note
If there is no input for approx. 2 minutes, inverter switches to standard display during feed.
134 56
12
11
10
32
Fig. 20 Display and operation
44
8 79
(1) Time (2) LED red (3) Scroll arrows horizontal (4) Title (5) LED green (6) Date (7) OK key (8) Navigation keys (9) ESC key (10)Device number (11)Scroll arrows vertical (12)Day
Page 45
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Time
Time display in 24-hour format.
LEDs
Two LEDs indicate the operating status of the inverter.
Display Operating status
LED off Normal operation
LED flashes - Error
- Contact for external indicator closed (depending on selected setting)
Display Operating status
LED on Power feed on
Operation
LED redThe LED red indicates the following:
LED greenThe LED green indicates the following:
LED flashes Preparing for power feed
LED off Inverter off
scan.
Scroll arrows
The menu contains other menu items. Â Navigate using keys T and S or W and X.
Title
Title of the selected menu.
Date
Date display in formats DD.MM.YY, MM.DD.YY oder YY.MM.DD. Adjustable in menu Time settings.
Keys
The functions of the keys are indicated in the tables under the illustrations.
Both LEDsBoth LEDs blinking indicate that the inverter is performing a network
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
45
Page 46
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Operation
Device number
Displays the inverter number.
Day
Displays the day of the week.
7.3 Standard screen
Key Function
WX
ST
ESC Call up Main Menu.
Navigate within the display period.
Switch to screen Current.
Arrow to the right of the table:
Î designation of physical value displayed in graphic
Number in the top left corner of the graphic:
Î maximum value of scale Î depending on max. DC power of the inverter
7.4 Main Menu
Key Function
ST
Navigate within menu.
OK Call up selected menu.
To return to main menu from all menus: Â Press ESC repeatedly.
46
Page 47
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
7.5 Operating Display
The operating display shows a list of physical values and a corresponding evaluation graph. Type and value of the displayed physical value depend on the selected period. The illustration below shows an example for the period TODAY.
Key Function
Operation
WX ST
ESC Back to Main Menu.
Navigate within the display period.
Switch to menu Current.
Arrow to the right of the table:
Î designation of physical value displayed in graphic
Units:
Î W: feed power Î kWh or MWh: feed power for the indicated period Î EUR: rebate for the indicated period (Adjustable in menu
Settings.)
Î kg: quantity of saved carbon dioxide (CO
)
2
Number in the top left corner of the graphic:
Î maximum value of scale Î dependent on inverter power
Horizontal axis in graphic:
Î time scale (e. g. hours of a day)
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
47
Page 48
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Operation
Current
Screen Current shows the distribution of the current power to the individual inverter modules.
Î Bar frame displays maximum power of respective inverter. Î Bar content displays current power of respective inverter.
Key Function
S Call up screen Operating Display.
T Call up screen Current Phase 1.
ESC Back to Main Menu.
Show current phase 1, phase 2 or phase 3:
Î List of current electrical values for DC and AC side. Î Separate AC currents for all three phases.
48
Page 49
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Key Function
S Call up screen Current.
T Call up screen Current Phase 2.
ESC Back to Main Menu.
Operation
Key Function
S Call up screen Current Phase 1.
T Call up screen Current Phase 3.
ESC Back to Main Menu.
Key Function
S Call up screen Current Phase 2.
T Call up screen Operating Display.
ESC Back to Main Menu.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
49
Page 50
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Operation
Physical values
The following physical values are indicated:
Î feed power in W (graphically depicted in the periods TODAY and
YESTERDAY)
Î feed energy in kWh or MWh (graphically depicted as columns in
the periods WEEK, MONTH and YEAR)
Î Rebate in country-specific currency
t Values > 999,000 are displayed as a factor t Example: 1,234,567 € is displayed as 1,234E6
Î CO Î DC and AC voltage
Î DC and AC Î DC and AC power
Display period
The following display periods can be selected:
Î Tod ay Î Yesterday Î Current week Î Previous week Î Current month Î Previous month Î Current year Î Previous year Î Since startup
emission reduction in kg or t
2
Note
The values displayed by the inverter may differ from the readings of calibrated electricity meters.
50
1 2
(1) Physical values (2) Graphic of physical value
Page 51
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Physical values:
t Designation of the physical value t Current value ( ) t Peak value ( ) t Cumulative value ( )
Graphic of physical value:
Î Day: in hours (0 - 24) Î Week: one column per day (Mo. - Su.) Î Month: one column per day Î Year: one column per month (Jan. – Dec.)
Operation
Type and value of the displayed physical value depend on the selected period. Graphic: For the display periods TODAY and YESTERDAY, the progress of the feed power is displayed. For all other display periods the feed energy per time interval is displayed. Table: For the display period TODAY, the current power value is displayed. For all other periods, the maximum value is displayed.
Note
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
51
Page 52
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Operation
7.6 Settings
In the menu Settings the following settings are possible:
Î Time settings Î Language Î Alarm volume Î Alarm contact function Î LCD Î Rebate Î System Î Energy meter
Key Function
ST
Navigate within menu.
ESC Back to Main Menu.
OK Call up selected menu.
Time settings In the menu Time settings, the following settings are possible:
Î Date Î Time Î Date format Î Daylight saving time
Key Function
ST
ESC Back to menu Settings.
OK Call up selected menu.
Navigate within menu.
52
Page 53
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Key Function
Operation
Date
ST WX
OK Accept date setting.
Increment or decrement present digit.
Select next or previous digit.
Key Function
ST WX
OK Accept time setting.
Increment or decrement present digit.
Select next or previous digit.
Changing date or time can result in overwriting saved data or cause gaps in data recording.
Time
Note
To accept time setting:
 Select SELECT.  Press OK key.
The inverter automatically shares the new time setting with all network participants.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
53
Page 54
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Operation
To not accept time setting:
 Select CANCEL.  Press OK key.
Date format
Key Function
Daylight saving time
ST
OK Confirm format.
ESC Return to menu Time setting.
Select format.
Key Function
ST
OK Confirm selection.
ESC Return to menu Time setting.
Navigate within menu.
MANUALLY
Î Manual setting of daylight saving time required.
AUTOMATIC
Î Inverter sets daylight saving time automatically, depending on set
country and calendar.
54
Page 55
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
If the MANUALLY option is selected, the following screen will appear the next time the date or time is set:
To set daylight saving time:
 Select YES.  Press OK key.
Inverter adds 1 hour to set time.
To not set daylight saving time:
 Select NO.  Press OK key.
Operation
Inverter uses set time unchanged.
Alarm volume
Key Function
ST
ESC Back to menu Settings.
OK Accept alarm volume setting.
Increase or reduce alarm volume.
The inverter automatically transfers the alarm volume setting to all network participants.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
55
Page 56
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Operation
Alarmkontakt
Key Function
ST
ESC Back to menu Settings.
OK Accept setting.
Navigate within menu.
OFF
Î The alarm contact (NO contact) is constantly open if a safety-
relevant or blocking error occurs.
Î Alarm contact deactivated.
INTERVAL
Î The alarm contact (NO contact) opens and closes periodically if a
safety-relevant or blocking error occurs.
CONTINUOUS
Î If a safety-relevant or blocking error occurs, the alarm contact
(NO contact) is constantly closed until the error is remedied.
TEST
Î Close alarm contact temporarily while selecting a menu item.
56
Page 57
LCD
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
Key Function
ST WX
ESC Back to menu Settings.
OK Accept setting.
Increase or reduce contrast or brightness.
Navigate between input fields.
Feed payback
Key Function
CURRENCY Currency in which the rebate is displayed.
VALUE/KWH Value for 1 kWh feed current (for rebate calculation).
ST WX
ESC Back to menu Settings.
Increment or decrement present digit.
Navigate between input fields.
OK Accept setting.
If the inverters are connected to the PLATINUM network, the input of the value for the rebate is only necessary in one inverter. After the input is finished, the value is automatically transferred to all other inverters.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
Note
57
Page 58
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Operation
System
Key Function
ST
WX
ESC Back to menu Settings.
OK Accept setting.
Increment or decrement present digit.
Navigate between input fields.
Energy meter
The energy meter enables the metering of energy and operating hours since the start of the inverter or since a reset of the energy meter.
Key Function
BACK Back to menu Settings.
RESET Set energy meter to 0.
WX
Select BACK or RESET.
OK Confirm selection.
ESC Back to menu Settings.
58
Page 59
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
7.7 Information
The menu Information shows the following information:
Î Operating data Î System data Î Inverter type Î Inverter version Î Event information
Operation
The menu Information merely displays values. It is not possible to change the values.
Operating data
Key Function
S T
ESC Back to menu Main Menu.
OK Back to menu Main Menu.
GENERAL
Î Shows feed data of the inverter since the startup. Î Resetting is not possible.
Call up screen Inverter version.
Call up screen System data.
Note
METER 2
Î Shows feed data of the inverter since the latest reset of meter 2.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
59
Page 60
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Operation
System data
Key Function
S
T
ESC Back to menu Main Menu.
OK Back to menu Main Menu.
Call up screen Operating data.
Call up screen Inverter type.
NAME
Î Shows the name of the PV system.
NO. OF PARTICIPANTS
Î Indicates number of network participants (e. g. inverter and
monitoring devices such as PLATINUM PV-Monitor, PLATINUM ViewMaster and PLATINUM Webmaster).
NO. OF INVERTERS
Î Shows the number of inverters in the network.
60
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
Page 61
Inverter type
Key Function
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Operation
S
T
ESC Back to menu Main Menu.
OK Back to menu Main Menu.
Call up screen System data.
Call up screen Inverter version.
TYPE
Î Indicates inverter type.
S/N
Î Indicates inverter serial number.
When contacting the PLATINUM service, have the serial number ready.
After changing the inverter network parameters, the display indicates
USER-DEFINED NETWORK MONITORING..
Note
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
61
Page 62
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Operation
Inverter version
Key Function
S T
ESC Back to menu Main Menu.
OK Back to menu Main Menu.
Call up screen Inverter type.
Call up screen Operating data.
FIRMWARE
Î Shows the inverter firmware version.
HARDWARE
Î Shows the inverter hardware version.
EIA485
Î Shows the data bus software version.
BL
Î Shows version of bootloader software.
62
Page 63
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
7.8 Error display
The error displays are meant for the user. Any detected errors are displayed with a slight delay. In case of an error, the inverter displays the error type and error code. Error causes and measures see 12 Troubleshooting.
Three types of errors:
Î fatal errors Î blocking errors Î non-blocking errors
Fatal errors
Destruction of invterter due to fatal errors!
 Switch off AC.  Switch off DC.
Warning
If available:
 Set DC disconnector to 0.
Operation
 Notify PLATINUM service.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
63
Page 64
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Operation
Blocking errors
Danger to life due to electric shock!
 Have the inverter opened exclusively by the
PLATINUM service or service partners authorized by
Danger
In case of a blocking errror:
Î the inverter is permanently off. Î the inverter gives an optical alarm (red LED flashing). Î the inverter gives an acoustic alarm. Î the inverter closes the alarm contact.
Setting: see screen Settings t function Alarm contact.
DIEHL AKO.
Exclusively service personnel can remedy the blocking error and switch the inverter back on.
To stop the acoustic alarm: Â Press any key. To delete the error display: Â Press ESC key.
If the acoustic alarm is activated:
Î Inverter switches off acoustic alarm.
 Press key ESC again.
Inverter shows start screen. Red LED flashes as long as the error persists.
64
Page 65
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Non-blocking errors and warnings
Key Function
OK Clears the error display
ESC Leave error display.
Non-blocking errors are of a transient nature (e.g. mains voltage surge). The inverter remains switched off until the error cause no longer persists.
When the error has been remedied, the inverter automatically switches to normal operation.
Operation
Until the error is resolved:
Î The inverter displays the screen Non-blocking error. Î The red LED is flashing.
 Delete error display with key ESC.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
65
Page 66
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Service
8 Service
8.1 Service Menu
The menu Service offers the following information and functions:
Î display event list Î display parameters Î set max. unbalanced load (Phase balancer) Î Reconfiguration Î display startup date Î display feed meter
Note
Displaying other parameters or changing the parameters is exclusively possible with a separate service tool.
To call up the Service Menu: Â Go to menu Settings and select menu item Time setting and
press buttons W and X for about 3 s.
Key Function
ST
ESC Return to standard display.
OK Call up selected menu.
Navigate within menu.
66
Page 67
Event list
Key Function
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Service
ST
ESC Return to menu Service.
Navigate within the event list.
Columns:
Î 1. column: Event no. Î 2. column: If available, designation of unit within inverter Î 3. column: Event date Î 4. column: Event time Î 5. column: Event code
The inverter shows the last 100 detected events.
Explanations about the events see 12.1 Table of events.
Have the event code and the serial number ready when contacting the PLATINUM service.
Note
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
67
Page 68
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Service
Parameters
In some supply areas, the values for supply voltage and frequency may differ temporarily or permanently from the factory settings. It is possible to adapt the PLATINUM inverter to these values. Contact the PLATINUMservice for this.
The screens Parameters show the valid ENS type and the currently set parameters such as start time, minimum and maximum values of frequency and voltage with the respective reaction times.
The parameters can exclusively be modified by certified persons with the PLATINUM service tool.
Version Screen Version shows information on inverter type.
Key Function
S T
ESC Back to menu Main Menu.
Return to menu Service.
Call up screen Frequency Limits.
68
Page 69
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Î set frequency limits Î switch-off times for exceeding or falling below frequency limits
Key Function
Service
Frequency limitsScreen Frequency Limits shows:
S
T
ESC Back to menu Main Menu.
Î set voltage limits Î switch-off times for exceeding or falling below frequency limits
Call up screen Version.
Call up screen Voltage Limits.
Key Function
S T
ESC Back to menu Main Menu.
Call up screen Frequency Limits.
Call up screen Mains Quality.
Voltage limitsScreen Voltage Limits shows:
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
69
Page 70
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Service
Mains quality Screen Mains Quality shows information on mains quality.
Key Function
S
T
ESC Back to menu Main Menu.
Call up screen Voltage Limits.
Call up screen Fault Current.
Fault current Screen Fault Current shows:
Î set limits for fault currents or fault current changes Î switch-off times for exceeding ot falling below fault current limits
Key Function
S T
ESC Back to menu Main Menu.
Call up screen Mains Quality.
Call up screen Fault Current.
70
Page 71
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Key Function
Service
S T
ESC Back to menu Main Menu.
Î AC and DC powers Î AC and DC currents
Call up screen Fault Current.
Call up screen Limits.
Key Function
S
T
ESC Back to menu Main Menu.
Call up screen Fault Current.
Call up screen Version.
LimitsScreen Limits shows set limits of:
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
71
Page 72
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Service
Phase Balancer
It is possible to set the admissible maximum power (unbalanced load) and the reaction time according to the specifications of the power plant operator.
Operating mode
Key Function
ST
ESC Back to menu Main Menu.
OK Accept selected operating mode.
Select operating mode.
OFF
Î Switch off Phase Balancer function. Î No limit of unbalanced load.
POWER CONTROL
Î Switch on Phase Balancer function. Î The inverter monitors and limits the difference between AC
powers.
ERROR OFF
Î If one inverter module fails, the inverter will disconnect the other
modules from the mains.
ERROR REDUCE
Î If one inverter module fails, the inverter limits the AC power of the
other modules to the set unbalanced load.
72
Page 73
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Key Function
Service
admissible maximum power (unbalanced load)
ST
WX
ESC Back to menu Main Menu.
OK Accept setting.
Increment or decrement present digit.
Select next or previous digit.
Range of values:
Î 200 W to 9,999 W
Factory setting:
Î 5,000 W
Key Function
Reaction time
ST
WX
ESC Back to menu Main Menu.
OK Accept setting.
Increment or decrement present digit.
Select next or previous digit.
Range of values:
Î 10 s to 9,999 s
Factory setting:
Î 300 s
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010
Mat. No. 737 576-AB
73
Page 74
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Service
If the inverter is connected in the PLATINUM network, all parameters and the Phase Balancer settings are transferred to the other inverters of the PLATINUM network after the reaction time has been confirmed.
During the transfer, the inverter shows the following screen.
After a successful transfer, the inverter shows the following screen.
Note
Reconfiguration
Inverter shows screen Start initial startup (see 6.1 Initial startup of inverter).
A reconfiguration of the country is only possible within the first four hours after the connection. Afterwards, this menu item is blocked.
74
Page 75
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Startup
Key Function
OK Return to menu Service.
ESC Return to menu Service.
Shows startup date.
Service
The menu is only a display. Values cannot be changed.
Meter
Key Function
OK Return to menu Service.
ESC Return to menu Service.
The menu is only a display. Values cannot be changed.
Inverter numbering
To change the inverter numbering after startup:
 Select Reconfiguration in the Service Menu.  Change inverter numbers see 6.1 Initial startup of inverter,
subsection Allocating inverter numbers.
Note
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
75
Page 76
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Maintenance
9 Maintenance
Danger to life due to electric shock!
 Have the inverter opened exclusively by the
PLATINUM service or service partners authorized by
Danger
Danger
DIEHL AKO.
Danger to life do to DC and AC high voltage!
 Wear insulating protective clothing and face
protection.
 Have any cleaning or maintenance works carried out
exclusively by trained personnel. The qualified specialist personnel requires a license from the relevant energy suppliers.
Prior to every maintenance work or cleaning:
 Switch off the main power supply (fuse).  Set switch knob of DC connector to 0.  De-energize AC side and secure it against switching
on.
 Condensers require up to 30 min to discharge. Do not
touch connectors (DC/AC) for at least 5 minutes after switching off.
 Ensure that the DC cables are de-energized.
In case of a PLATINUM inverter without DC disconnector and AC cable:
 Disconnect in the following order:
1. Remove cable from terminal strip on AC side.
2. Pull DC plug.
9.1 Maintenance
The inverter is maintenance-free.
76
Page 77
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
9.2 Cleaning
Damage of fan due to high fan speed!
 Exclusively clean the PLATINUM inverter carefully
with compressed air.
Caution
To ensure proper cooling, do the following regularly: Â Clean ventilation openings with:
t vacuum cleaner t soft brush t compressed air
In a dusty environment: Â Check fan and cooling elements regularly and clean them if
necessary.
Maintenance
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
77
Page 78
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Placing out of operation
10 Placing out of operation
10.1 Dismounting
Danger to life do to DC and AC high voltage!
 Wear insulating protective clothing and face
protection.
Danger
 Have inverters uninstalled by qualified specialists
only. The qualified specialist personnel requires a license from the relevant energy suppliers.
 Switch off the main power supply (fuse).  Set switch knob of DC connector to 0.  Condensers require up to 30 min to discharge.
Do not touch connectors (DC/AC) for at least 5 minutes after switching off.
 Ensure that the DC cables are de-energized.
It is possible that DC cables carry dangerously high
voltages even if the DC disconnector is switched off. In case of a PLATINUM inverter without DC disconnector and AC cable:
 Disconnect in the following order:
1. Remove cable from terminal strip on AC side.
2. Pull DC plug.
To disconnect the inverter:
 Switch off the main power supply (fuse).  Remove cable from AC terminal.  Set DC disconnector to 0 and pull plug connector of input voltage
 Disconnect remaining connectors as required.
78
Danger
(DC side).
Danger to life due to inverter dropping from the wall!
 Use mounting elements appropriate for the mounting
wall and the weight of the inverter unit. During mounting and dismounting:
 Wear protective shoes.  Ensure a stable position.
Page 79
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Dismount the inverter as follows: Â Lift the inverter up and out of the mounting fixture.
Remove the mounting fixture as follows:
 Unscrew the mounting fixture.  Insert the mounting fixture at the back of the inverter.
In case of a return consignment: Â Pack the inverter in the packaging of the replacement. If a single inverter is returned: Â Demand additional packaging from Diehl-Controls or reuse it.
Placing out of operation
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
79
Page 80
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Placing out of operation
Packing up the wall-mounted device
1
2
3
4
Fig. 21 Packing up the wall-mounted device
(1) Upper part of packaging (2) Wooden protection elements (3) Bottom part of packaging (4) Transport pallet
 Put transport pallet 4 on even ground.  Put bottom part of packaging on transport pallet 4.  Put inverter in bottom part of packaging 3.  Put upper part of packaging 1 on inverter.  Secure the box with packing straps.
80
Page 81
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Packing up the free-standing device
Fig. 22 Packing up the free-standing device
Placing out of operation
1
(1) Transport pallet
 Put transport pallet 1 on even ground.  Put inverter on transport pallet 1.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
81
Page 82
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Disposal
11 Disposal
 Dispose of packaging and consumed parts
according to the rules and regulations
applicable in the country where the device was
installed.
 Do not dispose of the PLATINUM inverter in the
household waste.
Note
DIEHL AKO takes back PLATINUM inverters completely.
It is possible to dispose of PLATINUM inverter through communal disposal of electrical appliances.
12 Troubleshooting
12.1 Table of events
To isolate the error, have the following information ready when calling Service:
Î displayed error number (No.) Î serial number of the inverter (see 7.7 Information)
No. Operating status Measure
Fatal errors
90 AC voltage too high Separate inverter from mains.
Check connection of AC plug.
91 DC voltage too high Separate inverter from mains.
Separate inverter from DC terminal. Check module interconnection.
92 Polarity of DC connection
reversed
93 Insulation error between PV+ or
PV- and earth
94 Fatal
system error
95 Fatal
system error
82
Check DC connection.
Check insulation of PV modules. Check insulation of PV wiring.
Disconnect AC connector from inverter input. Call Service. Provide the service with the error code if required.
Call Service. Provide the service with the error code if required.
Page 83
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
No. Operating status Measure
Blocking errors
100
Blocking
to
system error
106
107
Blocking
to
system error
129
130 Connections L and N reversed Check connections L and N on AC plug.
131
Blocking
to
system error
199
Separate inverter from mains. Restart inverter.
If measure is not successful: Call Service.
Separate inverter from mains. Restart inverter.
If measure is not successful: Call Service.
Separate inverter from mains. Restart inverter.
If measure is not successful: Call Service.
Troubleshooting
167 Error in AC overvoltage protec-
tion
171 Error in DC overvoltage protec-
tion
175 Error in power electronics Call Service.
Non-blocking errors
201 AC voltage on feed phase below
or above limits
202
exclusively for 3 phase ENS
to
Voltage on one of the outer con-
204
ductors below or above limits
208 System incident on feed phase
(voltage peak)
Call Service. Provide the service with the error code if required.
Call Service. Provide the service with the error code if required.
Provide the service with the error code if required.
Have AC voltage of feed phase checked.
Ensure that all fuses are switched on.
Startup: Have inverter 3-phase connected.
If error occurs frequently: Have all bondings and fuses between the consumer’s terminal and the inverter checked. Have the mains quality checked.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
83
Page 84
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Troubleshooting
No. Operating status Measure
209 Mains quality limit
exceeded
210
Mains frequency above or
211
below limits
212
Diagnosis support during
to
service
213
214
too high fault current when
to
switching on
218
220
measured temperatures too
to
high
225
226 max. mains current exceeded Check AC side for short circuit.
230
Temperature sensor defective Separate inverter from mains. to 233
If mains voltage on feeding point is permanently too high: Check voltage dip on mains lead. Inform power plant operator. Check value for mains quality limit.
If inverter is running on emergency power (different main frequency): No measure required.
Provide the service with the error code if required.
If error occurs frequently: Check insulation resistance on DC side.
Check ventilation openings.
Restart inverter.
If measure is not successful: Call Service.
234
Diagnosis support during ser­to
vice 261
262 power supply on interface card
overloaded
263
Diagnosis support during to
service 289
271
max. AC exceeded Check AC side for short circuit. to 273
84
Separate inverter from mains. Restart inverter.
If measure is not successful: Call Service.
Disconnect connections on interface card Check connections on interface card for short circuit.
If measure is not successful: Call Service. Provide the service with the error code if required.
Provide the service with the error code if required.
Page 85
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Standards and Approvals
No. Operating status Measure
274 min. DC voltage not reached
275 manual stop Check position of EMERGENCY STOP switch.
Call Service. Provide the service with the error code.
291
Diagnosis support during
to
service
299
Warning
300
Diagnosis support during
to
service
399
Inverter stores warning in event memory
Information
400
Diagnosis support during
to
service
499
Inverter stores warning in event memory
Provide the service with the error code if required.
Provide the service with the error code if required.
Provide the service with the error code if required.
Causes
500
Diagnosis support during
to
service
599
Inverter stores warning in event
Provide the service with the error code if required.
memory
13 Standards and Approvals
The inverter complies to the following standards:
Î DIN EN 50178: 1998-04 Î DIN EN 61 000-3-2: 2006-10 Î DIN EN 61 000-3-12: 2005-09 Î DIN EN 61 000-3-3: 1994 / A2: 2005 Î DIN EN 61 000-3-11: 2001-04 Î DIN EN 61 000-6-2: 2006-03 Î DIN EN 61 000-6-3: 2007-09
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
85
Page 86
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Technical Data
14 Technical Data
Input characteristics 13000 TL 16000 TL 19000 TL 22000 TL
Maximum PV power 14,700 Wp 18,000 Wp 21,300 Wp 24,300 Wp
Maximum DC power 12,900 W 15,900 W 18,900 W 21,600 W
PV-voltage range, MPPT 351 – 710 V 349 – 710 V 350 – 710 V 351 – 710 V
Maximum DC voltage 880 V
Maximum input current 3 x 13.0 A 3 x 16.0 A 3 x 18.5 A 3 x 21.0 A
Number of string inputs 6 6 9 9
Number of MPP trackers 3
DC section switch device DC disconnector, integrated in the appliance
Reverse battery protection yes
Output characteristics
Nominal AC power rating 11,250 W 13,800 W 16,550 W 18,900 W
Nominal AC-intensity 3 x 16.3 A 3 x 20.0 A 3 x 23.9 A 3 x 27.4 A
Maximum AC power 12,360 W 15,000 W 18,000 W 20,700 W
Maximum AC intensity 3 x 17.9 A 3 x 21.7 A 3 x 26.1 A 3 x 30.0 A
Feed operation starts at 7 W 7 W 7 W 8 W
Mains output voltage range 3 x 230 V (+/-20%) feeding on three phases
Internal consumption at night below 6 W
Mains frequency 47.5 Hz – 52.2 Hz
Short-circuit proof yes
Interfaces
DC input DC plug, Multicontact MC3, MC4, Tyco
AC output Spring clamp connectors
PLATINUM network EIA 485, 2x RJ45 Western Modular add. plug connector with
terminal screws
Service interface EIA 232, SubD 9-pole socket
Potential-free contact Change-over contact, maximum 24 V
terminal screws
Appliance data
Maximum degree of efficiency 97.3% 97.4% 97.7% 98.0%
European efficiency 96.8% 96.8% 97.3% 97.6%
/2 A, plug connector with
AC
Weight 81 kg 84 kg 87 kg 87 kg
86
Page 87
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Technical Data
Input characteristics 13000 TL 16000 TL 19000 TL 22000 TL
Dimensions H 743 mm x W 972 mm x D 262 mm
Working temperature range -20 °C to +60 °C
Maximum temperature during nominal power
Storage temperature -20 °C to +80 °C
Maximum air humidity 95%
Degree of protection (except digital interface)
Optical display Full graphic 170 x 76 pixels
Integrated datalogger Storage capacity sufficient for 30 yrs operating time
Circuit concept Transformerless, DIVE, RAC-MPP, ENS according to VDE 0126-1-1
IP65 according to DIN EN 60529
Technical data apply to maximum height above MSL of 2,000 m.
+45 °C
Note
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
87
Page 88
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL EC Declaration of Conformity
15 EC Declaration of Conformity
Issuer’s name and address:
Diehl AKO Stiftung & Co. KG Pfannerstraße 75 D-88239 Wangen im Allgäu, Germany
Product
Solar inverter
designation:
Type designation: PLATINUM 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL
PLATINUM 13000 TL, 16000 TL, 19000 TL, 22000 TL
The designated devices comply with the provisions of EU directives. Especially the Low Voltage Directive 2006/65/EG and the EMC
directive 2004/108/EG.
The designated devices conform to the following norms:
Î DIN EN 50178: 1998-04 Î DIN EN 61 000-3-2: 2006-10 Î DIN EN 61 000-3-12: 2005-09 Î DIN EN 61 000-3-3: 1994 / A2: 2005 Î DIN EN 61 000-3-11: 2001-04 Î DIN EN 61 000-6-2: 2006-03 Î DIN EN 61 000-6-3: 2007-09
Consequently the products mentioned above carry the CE mark. Furthermore, we declare that the products mentioned above comply
with the prescriptions of the VDEW (German Electricity Industry Association) that apply to solar inverters according to the “Directive for the Connection and Parallel Operation of Energy Generation Equipments in the Low-Voltage Mains”.
Wangen im Allgäu, 09/01/2009 Diehl AKO Stiftung & Co. KG
ppa. Klaus Frehner CEO Photovoltaics
Phone: +49 (0) 7522 73 0 Fax: +49 (0) 7522 73 300 Mailto: info@diehlako.com www.diehlako.de
88
Page 89
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Manufacturers Warranty of Diehl AKO Stiftung & Co. KG
16 Manufacturers Warranty of Diehl AKO
Stiftung & Co. KG
(Address: D-88239 Wangen im Allgäu, Pfannerstraße 75)
1. Warranted Products This manufacturer’s warranty applies to transformerless three-phase
string inverters of the PLATINUM range of inverters for photovoltaic systems manufactured by Diehl AKO Stiftung & Co. KG (Diehl AKO), as far as these inverters were evidently purchased as new units from Diehl AKO or MATRIX Power Systems GmbH or from a wholesaler, retailer or specialist installation company authorized by Diehl AKO or MATRIX Power Systems (Warranted Products). Such evidence is regarded as given when Diehl AKO is provided with an original invoice documenting the delivery of a Warranted Product to the Warranted User and if Diehl AKO is identified as the manufacturer by an authentic manufacturer label on the Warranted Product.
2. Beneficiaries from this manufacturer’s warranty Diehl AKO grants this manufacturer’s warranty only to users who
demonstrably have purchased, and are the actual users of a Warranted Product (Warranted User). Traders of any kind and trade level do not gain from this manufacturer’s warranty any rights and claims against Diehl AKO.
3. Establishment of the warranty The manufacturer’s warranty is meant as an offer by Diehl AKO
directly to the Warranted User on entering a warranty agreement under the conditions laid down in this document. The warranty contract is established directly and automatically between Diehl AKO and the Warranted User at the moment of purchase of a Warranted Product, if the Warranted User does not object to the establishment of the warranty agreement, in writing to Diehl AKO within 2 (two) weeks from the purchase date of a Warranted Product.
4. Coverage of the manufacturer’s warranty The manufacturer’s warranty grants the Warranted User warranty
rights in addition to the Warranted User’s warranty rights granted by the respective vendor. Warranty rights vis-à-vis the respective vendor and statutory product liability rights are unaffected by the manufacturer’s warranty.
5. Period and assertion of the manufacturer’s warranty The manufacturer’s warranty applies to defects of the Warranted
Products which demonstrably occur between the beginning of the twenty-fifth and the end of the sixtieth month after installation and commissioning of a Warranted Product at the Warranted User’s premises (Warranty Period). This Warranty Period ends not later than
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
89
Page 90
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Manufacturers Warranty of Diehl AKO Stiftung & Co. KG
66 months after the manufacturing date of the Warranted Product, as stated on the type plate of the Warranted Product. For Warranted Products repaired or replaced by Diehl AKO, the manufacturer’s warranty expires with the end of the original Warranty Period. Legal and/or contractual warranty claims of any kind, which arise during a statutory or contractual warranty period, can not be derived from this manufacturer’s warranty.
Any claims based on the manufacturer’s warranty must be asserted in writing by the Warranted User to Diehl AKO within the Warranty Period. Such warranty claims can be submitted through an authorized specialist retailer, wholesaler or specialist installation company, or through MATRIX Power Systems GmbH.
6. Rights under the manufacturer’s warranty – Damage and costs not covered
If a defect of the Warranted Product occurs during the Warranty Period and if Diehl AKO is responsible for this defect and if this defect impairs or reduces the functionality of the Warranted Product to a significant extent, Diehl AKO will choose to carry out either free-of­charge repairs or free-of-charge replacement of the Warranted Products with a product that offers at least the same or the same type of functionality and performance.
Such repairs or replacement will be carried out only at the Diehl AKO factory. Transport to Diehl AKO must be in the original packaging or other packaging that is at least of the same quality as the original packaging. If the Warranted user requests repair or replacement at a site other than the Diehl AKO factory, Diehl AKO can agree to this request. In this case, however, the Warranted User will bear any travel costs and additional labor costs according to DIEHL AKO standard rates.
Any claims from the manufacturer’s warranty beyond free-of-charge repair or free-of-charge replacement are ruled out, especially any claims on compensation for defect-related capital damage, e.g. loss of profit including compensation for lost power feeds, costs of installation and de-installation, costs of fault diagnostics, recall costs and interruption to production processes.
If no defect is found in the Warranted Product sent in for repair or replacement, or if there is no claim based on the manufacturer’s warranty for any other reason, Diehl AKO may demand from the Warranted User an administration fee (flat rate per product) plus the costs of transport back to the Warranted User.
Any claims based on this manufacturer’s warranty expire 6 months after occurrence of the fault, but not later than 3 months after the end of the Warranty Period.
90
Page 91
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL
Manufacturers Warranty of Diehl AKO Stiftung & Co. KG
7. Exclusion cases
Any claims of the Warranted User are excluded in the following cases:
Î Improper use Î Unprofessional or incorrect installation, installation not complying
to standards, or installation not following the installation directions or instructions provided by Diehl AKO
Î Unprofessional or incorrect operation and use, or operation and
use against the operating directions or instructions provided by Diehl AKO
Î Operation with defective protective systems Î Any unauthorized modifications or repairs Î Use of replacement parts and accessories non-compliant with the
original Diehl AKO specifications
Î Failure to perform continuous maintenance according to the
maintenance directions and instructions provided by Diehl AKO
Î Removal, damage or destruction of the sealing or the type plate
installed by Diehl AKO or MATRIX Power Systems
Î Foreign-body influence and force majeure Î Non-compliance with applicable safety regulations Î Transpor t damage Î Lightning damage
8. Portability of the guarantee This agreement on guarantee and the rights that result from it can
only be transferred from a licencee to a third party with a previous, written approval. When the guaranteed products are removed from the original assembly and operation spot and reassembled at a different location the guarantee expires automatically.
In cases other than those agreed on the guarantee may be tranferred to a third licencee when (i) the third licencee acquires the operation real estate from the licencee entitled to the guarantee, (ii) proof of the acquisition is presented to Diehl AKO in written and with the naming of the third licencee, (iii) the products assembled that are guaranteed remain unchanged and (iv) the third licencee declares to Diehl AKO its agreement to these conditions of guarantee in written form.
Installation and operating manual: PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Version 05/2010 Mat. No. 737 576-AB
91
Page 92
PLATINUM Inverter 13000 TL, 16000 TL, 19000 TL, 22000 TL Manufacturers Warranty of Diehl AKO Stiftung & Co. KG
9. General provisions
Claims by the Warranted User based on this manufacturer’s warranty can only be transferred to third parties with prior written consent of Diehl AKO.
Should any clause of this manufacturer’s warranty be or become void, all other stipulations of the manufacturers warranty remain in force. In place of the clause that is or has become void, a valid clause is automatically regarded as agreed. The replacement clause will be as close as possible to the voided clause in its economic substance. The same rule applies to any missing clause in this agreement.
This manufacturer’s warranty is subject only to the laws of the Federal Republic of Germany, excluding the stipulations of Private International Law and the UN Convention on the International Sale of Goods.
The exclusive place of jurisdiction in case of any conflict arising from, or in connection with this manufacturer’s warranty, is Wangen im Allgäu/FRG.