Planika GaLiO Fire Pit Corten INSTALLATION and USER’S MANUAL

Copyright Planika Sp. z o.o. www.planikafires.com IG0281#01 02.17.2020 1
INSTALLATION and USER’S MANUAL
GaLiO Fire Pit Corten
Natural Gas/Propane-Butane/Propane
H H1
H2
H3
D1
D2
[mm]
650
320
30
300
350
950
H
D1
D2
H2
H1
H3
2
IT IS OBLIGATORY TO READ AND KEEP THIS INSTRUCTION MANUAL.
TABLE OF CONTENTS
1. INTRODUCTION ........................................................................................................................................................................................... 3
2. SAFETY INSTRUCTIONS ................................................................................................................................................................................ 5
2.1 Safety instruction regarding the use of the gas cylinders. ..................................................................................................................... 6
3. INSTALLATION ............................................................................................................................................................................................. 7
3.1. Box contents........................................................................................................................................................................................... 7
3.2. Unboxing and installation ...................................................................................................................................................................... 7
4. MONTAGE ................................................................................................................................................................................................... 8
4.1. Installation of glass screens .................................................................................................................................................................. 10
4.2. Installation of the gas linkage ............................................................................................................................................................... 10
4.2.1. Natural gas connection .................................................................................................................................................................... 10
4.2.2. Connection and replacement of the gas cylinder (LPG version) ...................................................................................................... 11
5. OPERATING INSTRUCTIONS ...................................................................................................................................................................... 11
5.1. General Notes ...................................................................................................................................................................................... 11
5.2. Setting up signal code .......................................................................................................................................................................... 11
5.3. Replacing the batteries ........................................................................................................................................................................ 12
5.4. Remote control (if delivered) ............................................................................................................................................................... 13
5.4.1. Setting fahrenheit or celsius ............................................................................................................................................................ 14
5.4.2. Setting the time ............................................................................................................................................................................... 14
5.4.3. Child proof ....................................................................................................................................................................................... 14
5.4.4. Switch the Fire ON and OFF ............................................................................................................................................................. 15
5.4.5. Stand-by mode (Pilot flame) ............................................................................................................................................................ 16
5.4.6. Flame height adjustment ................................................................................................................................................................. 16
5.4.7. Flame height directly to minimum position .................................................................................................................................... 16
5.4.8. Flame height directly to maximum position .................................................................................................................................... 16
5.4.9. Countdown timer ............................................................................................................................................................................ 17
5.4.10. Automatic Turn Down To Pilot ........................................................................................................................................................ 17
5.4.11. Automatic Shut Off .......................................................................................................................................................................... 17
5.5. Touchpad .............................................................................................................................................................................................. 18
6. TESTING ..................................................................................................................................................................................................... 18
6.1. Checking for gas leaks. ......................................................................................................................................................................... 18
6.2 Checking the flame appearance. .......................................................................................................................................................... 19
7. MAINTENANCE AND UPKEEP .................................................................................................................................................................... 19
7.1. Testing and cleaning ............................................................................................................................................................................. 19
7.2. Glass cylinder cleaning ......................................................................................................................................................................... 20
8. TROUBLESHOOTING .................................................................................................................................................................................. 20
9. PRESSURE ADJUSTMENT ........................................................................................................................................................................... 22
10. ELECTRICAL DIAGRAMS ............................................................................................................................................................................. 27
11. TECHNICAL SPECIFICATION ....................................................................................................................................................................... 28
12. MANUFACTURER’S CONTACT DETAILS...................................................................................................................................................... 29
13. DISTRIBUTOR’SCONTACT DETAILS ............................................................................................................................................................ 29
3
1. INTRODUCTION
The GaLiO Fire Pit Corten fireplace is a decorative fuel-effect gas appliances intended only for outdoor use. It is
obligatory to acquaint oneself with the below installation manual and user’s manual before committing to the
installation and use of the GaLiO Fire Pit Corten fireplace. This manual is to be kept safe for the lifetime of the device.
The Planika company designs and manufactures gas devices that meet the highest standards of quality, and safety.
The device meets the essential Gas appliances General requirements of the AS/NZS 5263.0:2017 and must be installed
in accordance with AS/NZS 5601.
Each gas fireplace produced by Planika is subjected to factory quality control, during which it undergoes rigorous safety
tests. Materials of the highest quality used for its production guarantee the user a smooth and reliable functioning of
the device.
The device is delivered together with the instruction manual and assembly instructions. The assembly instructions
provide the necessary information to install the device in such a way that it works properly and safely. In addition, you
can find technical data about the device, information on its maintenance and possible failures that may occur, along
with their possible causes and how to resolve them.
WARNING! The installer must be a certified and qualified specialist in gas heating and electricity and should have all
the qualifications required by local law.
CE Declaration of conformity
We hereby declare that both the design and construction of a gas heating device manufactured by Planika Sp. z o.o. (with registered office at
Bydgoska 38, 86-061 Brzoza, Poland) meet the essential requirements contained in the Directive and the Ordinance on gas appliances.
Product: Gas device with decorative combustion effect for outdoor use
Type Galio Insert, Galio Corten , Galio Corten Remote, Galio Fire Pit Insert , Galio Fire Pit Insert Remote, Galio Fire Pit Corten , Galio Fire Pit
Corten Remote
Standards: AS/NZS 5263.0:2017
The notified body: IAPMO R&T Oceana (7-11 Fullard Road, NARRE WARREN VIC. 3805 AUSTRALIA) has issued the certificate no. GMK10583 for
the above mentioned devices.
The company's quality control system guarantees that the mass-produced devices meet the essential requirements of the applicable Directives
and Regulations as well as the standards contained therein. This Declaration is annulled if any modifications are made to the device without the
prior written consent of Planika.
Brzoza 14.11.2019 Chairman of the Board
Jarosław Dąbrowski
4
INSTALLATION NOTICE
The installation of this appliance is only to be carried out by an authorized person in accordance with the
Manufacturers Instructions, local gas fitting regulations, AS/NZS5601.1 installation code for gas burning
appliances and any other relevant statutory regulations.
In all cases the installation of this appliance shall meet the requirements as set out in AS/NZS5601.1
IMPORTANT SAFETY NOTICES
DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE.
DO NOT USE OR STORE FLAMMABLE MATERIAL NEAR THE APPLIANCE.
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILST IT IS IN OPERATION.
DO NOT MODIFY THIS APPLIANCE.
THIS APPLIANCE IS DESIGNED TO OPERATE WITH LUMINOUS FLAMES. THIS MAY EXHIBIT SLIGHT CARBON
DEPOSITS. THIS IS A NORMAL CONDITION AND IS NOT COVERED BY WARRANTY THE GUARD IS FITTED TO
THIS APPLIANCE TO REDUCE THE RISK OF FIRE OR INJURY FROM BURNS AND NO PART OF IT SHOULD BE
PERMANENTLY REMOVED. FOR PROTECTION OF YOUNG CHILDREN OR THE INFIRM, A SECONDARY GUARD
IS REQUIRED.
WARNING
This fireplace has a naked flame, care should be taken when it is operating if children or the infirm are in close
proximity. A safety screen is recommended if constant supervision is not possible. It is recommended that a secondary
guard complying with AS-NZS2286 be installed.
The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilitites, or lack of experience and knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not
play with the appliance.
5
2. SAFETY INSTRUCTIONS
Read the instructions before using the appliance.
Use outdoors only.
The GaLiO Fire Pit Corten fireplace should be installed and serviced annually according to the below installation
manual as well as enforced national and local laws regarding gas safety (installation and use).
One needs to assess whether the data on the product plaque complies with the local type of gas and pressure.
Do not change the structure of the device or its sealed elements nor modify the default settings of the GaLiO
Fire Pit Corten fireplace.
Do not set any additional imitation blocks nor any glowing coal fragments on the burner or in the combustion
chamber.
A CO2 or a powder fire extinguisher needs to be placed near the device.
During the first ignition the GaLiO Fire Pit Corten fireplace needs to be burnt on maximum level for a few hours
in order for the elements to acquire correct temperature and for the remains of paint, lacquer and lubricant to evaporate.
The appliance must be fixed in position and not moved.
GaLiO Fire Pit Corten has been designed for decorative purposes. The surface of the GaLiO Fire Pit Corten
fireplace including the glass screens may get hot (up to 100 degrees Celsius) with the exception of the side walls of the appliance and the control panel. WARNING!!! Parts of the device that are easy to reach may be very hot. Keep children away from the device.
Glass panels must be installed when GaLiO Fire Pit Corten is in use.
This appliance must be kept away from flammable materials during use. Do not place any combustible
materials within a distance of 1 m of GaLiO Fire Pit Corten and 2 m over the appliance (Figure 1).
Figure 1: Minimum distance to flammable materials
• When the GaLiO Fire Pit Corten fireplace is on it’s not to be exposed to rain.
When not being used the GaLiO Fire Pit Corten is to be protected from atmospheric conditions and the main
valve of the gas cylinder needs to be turned off.
If the GaLiO Fire Pit Corten is not in use for a longer period of time (e.g. winter time), we advise you to protect
it with a cover.
Corrosion of the coating of the base of GaLiO Fire Pit Corten is a natural process resulting from the
characteristics of the Corten steel which the fireplace is made of. It is an additional protective layer of the
appliance against the negative influence of unfavorable weather conditions.
Other parts of the GaLiO Fire Pit Corten fireplace are made of stain resistant material.
Never leave a turned on GaLiO Fire Pit Corten without supervision.
6
The GaLiO Fire Pit Corten fireplace needs to be installed in a place inaccessible for children, unauthorised
persons or animals for the direct contact with the flame or hot parts of the device to be impossible.
In case of heavy wind the GaLiO Fire Pit Corten fireplace needs to be immediately turned off and one needs to
await until the heavy wind passes.
In case of noticing any sort of gas leaks the fireplace as well as the main valve of the gas cylinder need to be
turned off.
After use turn off the gas cylinder valve.
2.1 Safety instruction regarding the use of the gas cylinders.
Use only the type of gas and pressure specified by the manufacturer.
The gas cylinders should always be placed in a vertical position – during use and transport.
Always store the gas cylinder in an easily accessible place to allow its immediate turn-off.
During the installation process do not allow an open flame or any ignited object to reach the gas cylinder.
The gas cylinder must be located in accordance with AS/NZS 5601 and AS/NZS 1596.
Leaks should be found with the use of a cleaning liquid and water. If bubbles form on the surface that means
that there’s a leak that must be fixed before operation.
Use only approved and certified hose and regulator assemblies, check condition before each use and replace
every 2 years.
Ensure any hoses are kept away from sharp edges and hot surfaces. Refrain from bends and twists over its full
length.
Remember that the LPG bottle should be stored in a well-ventilated place. LPG gas is heavier than air and its
accumulation near the bottom surface may generate an explosive mixture.
The housing in which the LPG bottle is (optionally) placed needs to have an appropriate ventilation. The
housing needs to have upper and lower ventilation (minimum 200cm2 each, in accordance with AS/NZS
5601.1).
The gas cylinder needs to be shut if the fireplace is not being used.
Filling the gas cylinders is to be commissioned to certified gas filling stations.
Replacement of empty cylinders for full ones is to be conducted only in authorised locations.
7
3. INSTALLATION
3.1. Box contents
1x complete GaLiO Fire Pit Corten gas fireplace
1x remote control (if delivered)
1x Touch panel (installed)
4x AA Batteries
2x AAA Batteries (if remote delivered)
4x bag of decorative stones
1x AS/NZS 1869 hose assembly – installed (only LPG version)
1x pressure regulator– installed (only LPG version)
1x installation manual and user’s manual
1x Tempered glass cylinder
3.2. Unboxing and installation
The contents of the boxes need to be carefully unwrapped from the foam foil.
Remove the bags with decorative stones from the burner reservoir and place them away from it.
Remove the Styrofoam placed on the unit.
Carefully lift the appliance and pull out the glass shield wrapped in cardboard from the inside of the GaLiO Fire
Pit Corten.
Check the completeness of the elements with the contents list.
Make sure that the device nor its elements weren’t damaged during the transportation (if they were, notify
the supplier).
Place GaLiO Fire Pit Corten on a flat, paved surface outside of the building, preferably on the place of final
installation. Leave sufficient space on the side of the appliance where control panel is located (minimum 1 m).
The decorative stones are to be scattered evenly around the reservoir to completely cover the burner of the
fireplace.
WARNING!!! The stones may not cover or be placed inside the device protecting the ignition unit (Photo 1).
It is forbidden to place any other decorative stones which are not supplied by the manufacturer.
Delivered stones (Silicon Carbide – SiC, content 85%-95%).
Photo 1
Carefully install the side glass cylinder (See point 4.1).
In the case of GaLiO Fire Pit Corten powered with natural gas, to obtain the optimum image of the flame, cover
the burner with a single layer of decorative stones leaving some spaces uncovered of approximately every 10 cm (Photo 2).
Photo 2
If all the points were completed according to the instruction the gas bottle can be now connected
8
4. MONTAGE
WARNING!!! All elements above the fireplace need to be made of non-flammable materials.
Select a location where the outdoor fire can be supervised during operation.
The outdoor fire is suitable for outdoor use only and must not be used indoors.
An isolation switch must be fitted at the appliance or on an adjacent wall to allow for emergency shutdown
and maintenance.
Installation must meet Australian gas codes AS/NZS5601.1-2013.
Do not install under trees or overhanging branches.
Do not install under eaves, overhang or ceilings.
Ensure adequate space around the fire to enjoy the flame from a safe distance from the heat and flame.
Appliance should be covered or protected in wet weather. Not suitable for use in wet or windy weather.
Only use this appliance in an above ground open air situation with natural ventilation, without stagnant areas, where
gas leakage and products of combustion are rapidly dispersed by wind and natural convection.
Any enclosure in which the appliance is used shall comply with the following:
An enclosure with walls on all sides, but at least one permanent opening at ground level and no overhead
cover.
Within a partial enclosure that includes an overhead cover and no more than two walls.
Within a partial enclosure that includes an overhead cover and more than two walls the following shall
apply.
o at least 25% of the total wall area is completely open, and
o at least 30% of the remaining wall area is open and unrestricted
In the case of balconies, at least 20% of the total wall area shall be and remain open and unrestricted.
This appliance shall not be used or installed indoors.
The following figures are diagrammatical representations of outdoor areas
9
Gas fire pit minimum height must comply with:
A gas fire pit with a burner less than 1m above the ground must be guarded to the full height of the flame such
that a child aged between 2 and 6 years of age cannot gain access to the flame when assessed in accordance
with IEC Guide 117.
A guard incorporated into an appliance to comply with requirement 2 (above) must be an integral part of the
appliance.
All necessary information concerning the touchable surfaces of the equipment, including the following, shall be
gathered:
Classification of surface temperatures as hot, moderate or cold
Material and texture of the surface
All normal operating conditions of the equipment including the setting that results in maximum temperatures
of the touchable surfaces
The probability of contact, taking into account the arm’s reach of a person shown in below Figure and Table
Age (Years)
Arm’s reach in the vertical direction
(see (a) of Figure measured from the floor (m)
Children from 2 years to less than 6 years
1,5
Loading...