Planika G20, G25, G30, G31 User Manual

Copyright Planika Sp. z o.o. www.planikafires.com IG0033#09 19.05.2020 1
INSTALLATION and USER’S MANUAL
Galio Corten/Black Automatic
G20/G25 (Natural Gas) G30/G31 (Propane-Butane/Propane)
Planika Sp. z o.o.
Bydgoska 38
86-061 Brzoza
Poland
H1
D
H
H2
D1
L
L4
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#09 19.05.2020 2
IT IS OBLIGATORY TO READ AND KEEP THIS INSTRUCTION MANUAL.
TABLE OF CONTENTS
1. INTRODUCTION .......................................................................................................................................................................... 3
2. SAFETY INSTRUCTIONS ............................................................................................................................................................... 3
2.1 Safety instruction regarding the use of the gas cylinders. ................................................................................................ 4
3. INSTALLATION ............................................................................................................................................................................ 5
3.1. Box contents ...................................................................................................................................................................... 5
3.2. Outline of the device ......................................................................................................................................................... 5
3.3. Unboxing and installation .................................................................................................................................................. 5
3.4. Installation of glass screens ............................................................................................................................................... 6
3.5. Gas cylinder montage (only LPG version) .......................................................................................................................... 7
3.6. Installation of the gas linkage ............................................................................................................................................ 8
3.6.1. Natural gas connection ................................................................................................................................................. 8
3.6.2. Connection and replacement of the gas cylinder (LPG version) ................................................................................... 8
3.6.3 Regulator replacement (LPG version) ......................................................................................................................... 10
4. OPERATING INSTRUCTIONS ..................................................................................................................................................... 12
4.1. General Notes .................................................................................................................................................................. 12
4.2. Setting up signal code before using the appliance for the first times ............................................................................. 12
4.3. Replacing the batteries .................................................................................................................................................... 12
4.3.1. Receiver ....................................................................................................................................................................... 13
4.4. Remote control (optionally) ............................................................................................................................................ 16
5.1.1 Switch the Fire ON and OFF ........................................................................................................................................ 16
5.1.2 Stand-by mode (Pilot flame) ....................................................................................................................................... 17
5.1.3 Flame height adjustment ............................................................................................................................................ 18
5.1.4 Flame height directly to minimum position ................................................................................................................ 18
5.1.5 Flame height directly to maximum position ............................................................................................................... 18
4.4.1. Automatic Turn Down To Pilot .................................................................................................................................... 19
4.4.2. Automatic Shut Off ..................................................................................................................................................... 19
4.5. Touchpad ......................................................................................................................................................................... 20
5. TESTING .................................................................................................................................................................................... 20
5.1 Checking for gas leaks. .................................................................................................................................................... 21
5.2 Checking the flame appearance. ..................................................................................................................................... 21
6. MAINTENANCE AND UPKEEP ................................................................................................................................................... 21
6.1. Testing and cleaning ........................................................................................................................................................ 21
6.2. Glass cleaning .................................................................................................................................................................. 22
7. TROUBLESHOOTING ................................................................................................................................................................. 22
8. TECHNICAL SPECIFICATION ...................................................................................................................................................... 23
9. MANUFACTURER’S CONTACT DETAILS .................................................................................................................................... 23
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#09 19.05.2020 3

1. INTRODUCTION

The Galio Corten/Black Automatic fireplace is a decorative fuel-effect gas appliances destined only for outdoor use.
It is obligatory to acquaint oneself with the below installation manual and user’s manual before committing to the
installation and use of the Galio Corten/Black Automatic fireplace. This manual is to be kept safe for the lifetime of the device.

2. SAFETY INSTRUCTIONS

Read the instructions before using the appliance.
Use outdoors only.
The Galio Corten/Black Automatic fireplace should be installed and controlled annually according to the below
installation manual as well as enforced national and local laws regarding gas safety (installation and use).
One needs to assess whether the data on the product plaque complies with the local type of gas and pressure.
Do not change the structure of the device or its sealed elements nor modify the default settings of the Galio
Corten/Black Automatic fireplace.
Do not set any additional imitation blocks nor any glowing coal fragments on the burner or in the combustion
chamber.
A CO2 or a powder fire extinguisher needs to be placed near the device.
During the first ignition the Galio Corten/Black Automatic fireplace needs to be burnt on maximum level for
a few hours in order for the elements to acquire correct temperature and for the remains of paint, lacquer and lubricant to evaporate.
Do not move the device while it’s working.
Galio Corten/Black Automatic has been designed for decorative purposes. The surface of the Galio
Corten/Black Automatic fireplace including the glass screens may get hot (up to 100 degrees Celsius) with the exception of the side walls of the appliance and the control panel. WARNING!!! Parts of the device that are easy to reach may be very hot. Keep children away from the device.
Glass panels must be installed when Galio Corten/Black Automatic is in use.
This appliance must be kept away from flammable materials during use. Do not place any combustible
materials within a distance of 1 m of Galio Corten/Black Automatic and 2 m over the appliance (Figure 1).
Figure 1: Minimum distance to flammable materials
• When the Galio Corten/Black Automatic fireplace is on it’s not to be exposed to rain.
When not being used the Galio Corten/Black Automatic is to be protected from atmospheric conditions and
the main valve of the gas cylinder needs to be turned off.
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#09 19.05.2020 4
If the Galio Corten/Black Automatic is not in use for a longer period of time (e.g. winter time), we advise you
to store it inside.
Corrosion of the coating of the base of Galio Corten is a natural process resulting from the characteristics of
the Corten steel which the fireplace is made of. It is an additional protective layer of the appliance against the negative influence of unfavorable weather conditions.
Other parts of the Galio Corten/Black Automatic fireplace are made of stain resistant material.
Never leave a turned on Galio Corten/Black Automatic without supervision.
The Galio Corten/Black Automatic fireplace needs to be installed in a place inaccessible for children,
unauthorised persons or animals for the direct contact with the flame or hot parts of the device to be impossible.
In case of heavy wind the Galio Corten/Black Automatic fireplace needs to be immediately turned off and one
needs to await until the heavy wind passes.
In case of noticing any sort of gas leaks the fireplace as well as the main valve of the gas cylinder need to be
turned off.
After use turn off the gas cylinder valve.

2.1 Safety instruction regarding the use of the gas cylinders.

Use only the type of gas and pressure specified by the manufacturer.
The gas cylinders should always be placed in a vertical position – during use and transport.
Always store the gas cylinder in an easily accessible place to allow its immediate turn-off.
During the installation process do not allow an open flame or any ignited object to reach the gas cylinder.
The gas cylinder should be in a distance not shorter than 1,5 metres away from the Galio Corten/Black
Automatic fireplace.
Leaks should be found with the use of a cleaning liquid and water. If bubbles form on the surface that means
that a there’s an existing leak.
Always use a pressure regulator between the gas bottle and the device. Replace the pressure regulator every
5 years. The allowed pressures are: 30mbar, 37mbar (recommended), 50 mbar. Use only regulators complying with the European EN16129 Norm.
Use only approved and certified gas connection linkage. Replace the linkage every 2 years.
The elastic linkage connecting gas to the fireplace is to be led away from sharp edges and hot surfaces. Refrain
from bends and twists of the elastic connection on its full length.
Remember that the LPG bottle should be stored in a well-ventilated place. LPG gas is heavier than air and its
accumulation near the bottom surface may generate an explosive mixture.
The housing in which the LPG bottle is (optionally) placed needs to have an appropriate ventilation. The
housing needs to have an upper ventilation slot above the top of the bottle (of an area min 1/100 of the area of the base of the housing) and a lower ventilation slot (of an area min 1/50 of the area of the base of the housing).
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#09 19.05.2020 5
The gas cylinder needs to be shut if the fireplace is not being used.
Filling the gas cylinders is to be commissioned to certified gas filling stations.
Replacement of empty cylinders for full ones is to be conducted only in authorised locations.

3. INSTALLATION

3.1. Box contents

1x complete Galio Corten/Black Automatic gas fireplace
1x remote control and 2x AAA Batteries (optionally)
2x Tempered glass screen
1x Touch panel (installed)
4x AA Batteries
4x bag of decorative stones
1x 4 metre rubber gas linkage – installed (only LPG version)
1x pressure regulator (37mbar) – installed (only LPG version)
1x installation manual and user’s manual

3.2. Outline of the device

Figure 2

3.3. Unboxing and installation

The contents of the boxes need to be carefully unwrapped from the foam foil.
Remove the bags with decorative stones from the burner reservoir and place them away from it.
Remove the Styrofoam placed on the unit.
Carefully lift the appliance and pull out the glass shield wrapped in cardboard from the inside of the Galio
Corten /Black Automatic.
Check the completeness of the elements with the contents list.
Make sure that the device nor its elements weren’t damaged during the transportation (if they were, notify
the supplier).
Place Galio Corten/Black Automatic on a flat, paved surface outside of the building, preferably on the place
of final installation. Leave sufficient space on the side of the appliance where control panel is located (minimum 1 m).
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#09 19.05.2020 6
The decorative stones are to be scattered evenly around the reservoir to completely cover the burner of the
fireplace.
WARNING!!! The stones may not cover or be placed inside the device protecting the ignition unit (Photo 1).
Photo 1
Install carefully the side glass shields (See point 3.4).
In the case of Galio Corten/Black Automatic powered with natural gas, to obtain the optimum image of the
flame, cover the burner with a single layer of decorative stones leaving some spaces uncovered of approximately every 10 cm (Photo 2).
Photo 2
If all the points were completed according to the instruction the gas bottle can be now
connected (See point 3.5).

3.4. Installation of glass screens

Carefully remove cardboard and foam foil from the glass screens.
Remove all contaminations from the glass shields which could burn out on the glass during operation of the
Galio Corten/Black Automatic (in particular fingerprints).
Install glass shields in the corresponding slots on the appliance as shown on Figure 3.
Copyright Planika Sp. z o.o. www.planikafires.com IG0033#09 19.05.2020 7
Figure 3
Remove the glass shield only in case of damage of the glass.

3.5. Gas cylinder montage (only LPG version)

The gas linkage attached to the device allows to place the gas bottle maximally 3 meters away from the connected control panel, however it cannot be placed nearer to the device than 1,5 meters.
Figure 4
The optional housing for the gas bottle cannot be airtight and has to be correctly ventilated. The housing needs
to have an upper ventilation slot above the top of the bottle (of an area min 1/100 of the area of the base of the housing) and a lower ventilation slot (of an area min 1/50 of the area of the base of the housing). The dimensions of the housing may vary to accommodate different types and dimensions of the gas bottles however they also have to be sufficient for hassle-free installation of the gas bottle.
Figure 5