PLANET makes no representations or warranties, either expressed or implied, with respect to the
contents hereof and specifically disclaims any warranties, merchantability or fitness for any particular
purpose. Any software described in this manual is sold or licensed "as i s". Should the programs
prove defective following their purchase, the buyer (and not this company, its distributor, or its dealer)
assumes the entire cost of all necessary servicing, repair, and any incidental or consequential
damages resulting from any defect in the software. Further, this company reserves the right to revise
this publication and to make changes from time to time in the conte nts hereof without obligation to
notify any person of such revision or changes..
All brand and product names mentioned in this manual are trademarks and/or register ed trademarks
of their respective holders.
FCC Caution:
To assure continued compliance.(example-use only shielded interface cables when connecting to
computer or peripheral devices). Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the Following two
conditions: (1) This device may not cause harmful interference, and (2 ) this Device must accept any
interference received, including interference that may cause undesired operation.
Federal Communication Commission (FCC) Radiation Exposure
Statement
This equipment complies with FCC radiation exposure set forth for an uncontrol led environment. In
order to avoid the possibility of exceeding the F CC radio frequency expos ure limits, human proximit y
to the antenna shall not be less than 20 cm(8 inches) during normal operation.
CE Mark Warning
This is a Class B product. In a domestic environment, this product may cause radio interference, in
which case the user may be required to take adequate measures.
Protection requirements for health and safety – Article 3.1a
Testing for electric safety according to EN 60950 has been conducted. These are considered relevant
and sufficient.
Protection requirements for electromagnetic compatibility – Article 3.1b
Testing for electromagnetic compatibility according to EN 301 489-1, EN 301 489-17 and EN 55024
has been conducted. These are considered relevant and sufficient.
Effective use of the radio spectrum – Article 3.2
Testing for radio test suites according to EN 300 328-2 has been conducted. T hese are considered
relevant and sufficient.
CE in which Countries where the product may be used freely:
France: except the channel 10 through 13, law prohibits the use of other channels
Safety
This equipment is designed with the utmost care for the safety of those who install and use it. However,
special attention must be paid to the dangers of electric shock and static electricity when working with
electrical equipment. All guidelines of this and of the computer manufacture must therefore be allowed
at all times to ensure the safe use of the equipment.
WEEE regulation
To avoid the potential effects on the environment and human health as a result of
the presence of hazardous substances in electrical and electronic equipment, end
users of electrical and electronic equipment should understand the meaning of the
crossed-out wheeled bin symbol. Do not dispose of WEEE as unsorted municipal
waste and have to collect such WEEE separately.
Revision
User’s Manual for PLANET 802.11g WLAN Outdoor CPE AP
Model: WAP-6100
Rev: 1.0 (June, 2006)
Part No. EM-WAP6100
APPENDIX A GLOSSARY.................................................................................................................33
Chapter 1 Introduction
The WAP-6100 is an outdoor 802.11g CPE AP with 12dBi antenna built in. This manual describes the
details of how to manage this equipment.
1.1 Package Contents
Make sure that you have the following items:
• One WAP-6100
• One Power Cord
• One PoE Injector
• One Metal Ring
• One 25m CAT5 Cable with RJ-45 plug and ODU connector
• One 1.9m CAT5 Cable with RJ-45 plugs
• One User’s Manual and Utility CD
• One Quick Installation Guide
Note:
If any of the above items are missing, contact your supplier as soon as
possible.
1.2 Features
‧ Wireless LAN IEEE802.11b/g compliant
‧ Solid housing provides protection against rigorous weather conditions
‧ Four operating modes support: AP, Wireless Bridge, Wireless Client, and Repeater
‧ Strong network security with 64/128/152-bit WEP encryption, WPA and WPA-PSK
‧ Built-in 12dBi patch antenna
‧ 5 levels of adjustable transmit power control
‧ Super G mode raises the data rate up to 108Mbps
‧ Support DHCP Client
‧ Provides “Connection Status” indication for Repeater and Client modes
‧ Power over Ethernet design
1.3 Specification
Model WAP-6100
Standard IEEE 802.11b, 802.11g
Signal Type DSSS (Direct Sequ ence Spread Spectrum)
Modulation OFDM with BPSK, QPSK, 16QAM, 64QAM, DBPSK, DQPSK, CCK
Port 10/100Mbps RJ-45 port * 1
Antenna Built-in 12dBi patch antenna
Output Power 18dBm@11Mbps / 17dBm@54Mbps (typical)
Group Key Update Interval: 300
Super G mode Up to 108Mbps
Data Rate
Dimensions (L x W x H) 185 x 106 x 62mm
Weight 400g
Environmental
Specification
Power Requirement 48V DC, 0.4A
Electromagnetic
Compatibility
802.11g
802.11b Up to 11Mbps (1/2/5.5/11)
Operating temperature: -10 – 70 degree C
Storage temperature: -30 – 80 degree C
Relative humanity: 0% – 90% (non-condensing)
FCC, CE
Up to 54Mbps (6/9/12/18/24/36/48/54)
1.5 Wireless Performance
The following information will help you utilizing the wireless performanc e, and operating coverage of
WAP-6100.
1. Site selection
To avoid interferences, please locate WAP-6100 and wireless clients away from transformers,
microwave ovens, heavy-duty motors, refrigerators, fluorescent lights, and other industrial
equipments. Keep the number of walls, or ceilings between AP and clients as few as possible;
otherwise the signal strength may be seriously reduced. Place WAP-6100 in open space or add
additional WAP-6100 as needed to improve the coverage.
2. Environmental factors
The wireless network is easily affected by many environmental factors. Every environment is
unique with different obstacles, construction materials, weather, etc. It is hard to determine the
exact operating range of WAP-6100 in a specific location without testing.
Chapter 2 Hardware Installation
Before you proceed with the installation, it is necessary t hat you have enough information about the
WAP-6100.
1. Locate an optimum location and use the provided metal ring to secure WAP-6100 to a mast.
2. Using provided CAT5 waterproof cable; connect the waterproof connector port of the WAP-6100
to the “P+DATA OUT” port of PoE Injector.
3. Using Category 3 or higher UTP or STP cable, connect the “DATA IN” port of PoE Injector to a
10Mbps or 10/100Mbps Ethernet hub or switch, and connect the management station to a hub or
switch on the same LAN.
4. Connect the power cord to the PoE Injector, and plug it into an AC outlet to power up the
WAP-6100.
Note: ONLY use the power adapter supplied with the WAP-6100. Otherwise, the product may be
damaged.
OUTDOOR INSTALLATION WARNING
!
IMPORTANT SAFETY PRECAUTIONS:
LIVES MAY BE AT RISK! Carefully observe these instructions and any special instructions that are
included with the equipment you are installing.
CONTACTING POWER LINES CAN BE LETHAL. Make sure no power lines are anywhere where
possible contact can be made. Antennas, masts, towers,
guy wires or cables may lean or fall and contact these
limes. People may be injured or killed if they are touching
or holding any part of equipment when it contacts electric
lines. Make sure there is NO possibility that equipment or
personnel can come in contact directly or indirectly with
power lines.
Assume all overhead lines are power lines.
The horizontal distance from a tower, mast or antenna to the nearest power line should be at least twice
the total length of the mast/antenna combination. This will ensure that the mast will not contact power if it
falls either during installation or later.
TO AVOID FALLING, USE SAFE PROCEDURES WHEN WORKING AT HEIGHTS ABOVE GROUND.
z Select equipment locations that will allow safe, simple equipment installation.
z Don’t work alone. A friend or co-worker can save your life if an accident happens.
z Use approved non-conducting lasers and other safety equipment. Make sure all equipment is in
good repair.
z If a tower or mast begins falling, don’t attempt to catch it. Stand back and let it fall.
z If anything such as a wire or mast does come in contact with a power line, DON’T TOUCH IT
OR ATTEMPT TO MOVE IT. Instead, save your life by calling the power company.
z Don’t attempt to erect antennas or towers on windy days.
MAKE SURE ALL TOWERS AND MASTS ARE SECURELY GROUNDED, AND ELECTRICAL
CABLES CONNECTED TO ANTENNAS HAVE LIGHTNING ARRESTORS. This will help prevent fire
damage or human injury in case of lightning, static build-up, or short circuit within equipment connected
to the antenna.
zThe base of the antenna mast or tower must be connected directly to the building protective
ground or to one or more approved grounding rods, using 1 OAWG ground wire and
corrosion-resistant connectors.
zRefer to the National Electrical Code for grounding details.
IF A PERSON COMES IN CONTACT WITH ELECTRICAL POWER, AND CANNOT MOVE:
z DON’T TOUCH THAT PERSON, OR YOU MAY BE ELECTROCUTED.
z Use a non-conductive dry board, stick or rope to push or drag them so they no longer are in
contact with electrical power.
Once they are no longer contacting electrical power, administer CPR if you are certified, and make sure
that emergency medical aid has been requested.
Loading...
+ 24 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.