The purpose of the document is to specify a Single phase AC input, single output
switching power supply. This specification is suitable for: EA10681T Series
This product is AC to DC switching power transfer device, it can provide
for a 54V,1.33A max & 72W max DC output with constant voltage source.
This Specification defines the input, output, performance characteristics, environment,
noise and safety requirement for a power supply.
2-0. Input Requirements
2-1. AC Input Voltage
Maximum Voltage: 264Vac
Normal Voltage : 100~240Vac
Minimum Voltage: 90Vac
2-2. AC Input Frequency
Maximum Frequency: 63Hz
Normal Frequency: 50~60Hz
Minimum Frequency: 47Hz
2-3. Input Current
2.0A (Max.) @ 100Vac/60Hz-240Vac/50Hz with full load.
2-4. Energy saving standards:
2-4-0.Designed to meet the following standard :
Energy Efficiency level VI
2-4-1.Efficiency
≧88% ( avg. ) at 115Vac/60Hz & 230Vac/50Hz input voltage and 25%, 50%, 75%
&100% of max output current.
2-4-2 No Load Power Consumption.
No Load Watt<= 0.21W at normal line input.
2-5. Configuration
3-wire AC input (Line ,Neutral, FG)
2-6. Input Fuse
The hot line side of the input shall have a fuse, rating (3.15A/250V)
2-7. Inrush Current
≦80A at 110 Vac
≦ 120A at 220 Vac At cold start, maximum load.
2-8. Line Regulation
This line regulation is less than ± 1%, of rated output voltage @ full load.
2-9. Hold Up Time
≧ 8.3 mSec., @ Normal line, with full load.
2-10. Rise Time
≦50 mSec., @ 115V AC input, with full load.
From 10% to 90% of output voltage.
2-11. Turn-ON Time
The output voltage should rise to 90% of rated output voltage
in less than 3 SEC. from AC apply to 110Vac start up.
3-0. Output Requirements
3-1. Output Voltage and Current
Output Voltage (Vdc) Current Min.(A)Current Max.(A)
3-2. Load Regulation
Voltage (Vdc)Tolerance (%) Regulation (Vdc)
3-3. Dynamic Load Regulation
±5% excursion for 50% - 100% or 100% - 50% load change of DC output at
+54V 0 1.33A
+54V +5/, -5 51.3~56.7V
any frequency up to 1KHz(duty 50%)
3-4. Ripple & Noise
The power supply shall not exceed the following limits on the indicated voltage for 60Hz
or 50Hz ripple, Switching frequency ripple and noise and dynamic load variations
measured with a 20MHz bandwidth
Output Ripple/Noise
+54V
Input condition : for rated voltage , Output condition : for max load
Ripple / Noise: 60Hz ripple + switching ripple and noise
Ripple & Noise are measured at the end of output cable which are
added a 0.1uF ceramic capacitor and a 47uF electrolytic capacitor
3-5. Over Voltage Protection
150% Max. of rated voltage.
The output voltage shall be shutdown and auto-recover mode when OVP occurred.
3-6. Stability
2% Max. at constant load with constant input (after 30 minutes of operation).
3-7 Over Current Protection
110~200% output current. At 100-240Vac input,
The adapter can withstand continuous short at DC output and no damage.
1.0% max. of rated output voltage
It will enter into normal condition if the fault condition is removed.
3-8.Temperature Rise
Less than 45℃ on top/bottom case at normal AC input & 80% load of DC output at
environment temperature 25℃.
3-9. Drop-out
Output voltage shall remain within the specified regulation range, through the absence of
a line input during 1/2 cycle, at full load and normal AC line input
3-10. Voltage Isolation
The DC ground will be isolated from the AC neutral and AC line.
DC ground is also isolated (1KV) from Earth Ground.
4-0.Reliability
4-1. MTBF ( MIL-HDBK-217F )
The power supply shall be designed and produced to have a mean time between failure
( MTBF) of 100,000 hours at 25 degrees C.
5-0. Environment
5-1 Temperature
a. Operating : 0 to 40 ℃
b. Storage : -20 to 85 ℃
5-2 Humidity
a. Operating : 10 to 90 %
b. Storage: 5 to 90 %
5-3 Altitude
From sea level to 5,000 Meters (operation) and 5,000 Meters (non operation)
6-0. Safety
6-1. Hi-Pot Test
3000Vac, 10mA 2Sec. between primary and secondary circuit
1800Vac, 10mA 2Sec. between L,N and FG circuit
6-2. Insulation Test
500Vdc, 2 Sec. between primary and secondary circuit
IR should ≧ 50 MΩ.
RS Frequency: 1KHz Field Strength: 3V/M IEC 61000-4-3
EFT 1.0 KV on input AC power ports. IEC 61000-4-4
Line to Line: ± 1KV (peak)
SURGE
Line to F.G : ± 2KV (peak)
IEC 61000-4-5
6-6. EMI
Comply with Standards
CISPR 32, EN 55032 Class B
FCC (PART 15 CLASS B)
7-0. Mechanical Characteristics
7-1. Physical Size : 113 mm (L) * 49 mm (W) * 35.0mm (H)
7-2. Enclosure material : 94V-1 minimum
7-3. Output Cable (Reference) : UL1185 #18
7-4. Vibration Test
The vibration frequencies are set at 20Hz, with total amplitude of 1.5mm
Along the 3 directions namely X-Y-Z. The each direction should be vibrated
for 60 minutes, after testing no abnormal electrical or mechanical should occur.
7-5. Drop Test (Referencing to CSA C22.2 No.950/UL1950/UL1310/EN60950)
Products shall be dropped from a height of 900 mm onto a horizontal surface
consists of hardwood at 13mm thick, mounted on two layers of plywood each
19mm to 20mm thick, all supported on a concrete or equivalent non-resilient
floor. Upon conclusion of test, the equipment need not be operational.
7-6. Net Weight (Reference) : 300 g