Copyright (C) 2003 PLANET Technology Corp. All rights reserved.
The products and programs described in this User’s Manual are licensed products of PLANET
Technology, This User’s Manual contains proprietary information protected by copyright, and
this User’s Manual and all accompanying hardware, software, and documentation are copyrighted.
No part of this User’s Manual may be copied, photocopied, reproduced, translated, or reduced
to any electronic medium or machine-readable form by any means by electronic or mechanical.
Including photocopying, recording, or information storage and retrieval systems, for any purpose other than the purchaser's personal use, and without the prior express written permission
of PLANET Technology.
Disclaimer
PLANET Technology does not warrant that the hardware will work properly in all environments
and applications, and makes no warranty and representation, either implied or expressed, with
respect to the quality, performance, merchantability, or fitness for a particular purpose.
PLANET has made every effort to ensure that this User’s Manual is accurate; PLANET disclaims liability for any inaccuracies or omissions that may have occurred.
Information in this User’s Manual is subject to change without notice and does not represent a
commitment on the part of PLANET. PLANET assumes no responsibility for any inaccuracies
that may be contained in this User’s Manual. PLANET makes no commitment to update or keep
current the information in this User’s Manual, and reserves the right to make improvements to
this User’s Manual and/or to the products described in this User ’s Manual, at any time without
notice.
If you find information in this manual that is incorrect, misleading, or incomplete, we would
appreciate your comments and suggestions.
CE mark Warning
The is a class B device, In a domestic environment, this product may cause radio interference,
in which case the user may be required to take adequate measures.
Trademarks
The PLANET logo is a trademark of PLANET Technology. This documentation may refer to
numerous hardware and software products by their trade names. In most, if not all cases, these
designations are claimed as trademarks or registered trademarks by their respective companies.
Revision
User’s Manual for PLANET Internet Camera:
Model: ICA-100/ICA-100W
Rev: 2.0 (July 2003)
Part No. EM-ICA100v2
APPENDIX A FREQUENTLY ASKED QUESTIONS...................................................59
APPENDIX B TROUBLE SHOOTING.........................................................................61
APPENDIX C I/O CONNECTORS...............................................................................63
APPENDIX D ADJUST FOCUS/ REPLACE LENS.....................................................65
Adjust Internet Camera Focus...........................................................................65
Replace the Lens.................................................................................................66
APPENDIX E INSTALL XPLUG CONTROL UTILITY.................................................67
Install on Web Server..........................................................................................67
Install to Local PC...............................................................................................67
APPENDIX F SPECIFICATION...................................................................................71
APPENDIX G GLOSSARY OF TERMS.......................................................................73
i
1
Chapter 1
Introduction
This Chapter provides an overview of Internet Camera 's features and
capabilities.
Internet Camera provides a low cost solution for enterprise and SOHO users to enhance the ability of network environment. By connecting directly to an Ethernet or Fast
Ethernet, the high quality video image can be monitored everywhere. The main difference from the conventional PC Camera is that Internet Camera is a standalone system.
There is no need to attach another computer with Internet Camera like usual PC
cameras do. Via a web browser, Internet Camera can be managed, accessed and
controlled remotely over the Intranet or Internet. Management can be more efficient
and relative cost will be reduced by this way.
ICA-100/ICA-100W Features
Internet Camera includes many advanced features, which are designed to provide
powerful functions while being easy to use.
Vivid Your Website.
Live-images on web site is a new trend of Internet nowadays. Must websites always
be immutable and frozen with only text and static pictures? Add ICA-100 series to
make websites more vigorous.
User-friendly Interface.
Internet Camera supports both ActiveX mode for Internet Explorer and Java mode
for Internet Explorer and Netscape Navigator. The only requirement for configuration
and image viewing is a web browser software such as Internet Explorer 5.0 or above
or Netscape 6.0 or above. Via user-friendly web interface, even a beginner with less
knowledge about network can manage easily.
Remote Monitoring and Management.
ICA-100 series can fully integrate with your network. By the conveniences of world
wide Internet, you can do the monitoring anywhere. Via add-on utility, network administrators can decide whether individuals or the whole team may access ICA100 series.
Multi-user password protection support offers more flexibility while managing ICA100
series.
Alarm Trigger Function.
Adding external sensors to the auxiliary I/O connecter of ICA-100 series can let you
program event-based notification to fit various security demands. Internet Camera can
connect up to two input and two output external devices.
DDNS Support
Internet users can access the live images with a DDNS registered hostname instead of
knowing camera’s real IP address.
1
Broadband Router User Guide
Motion Detection
Monitor any suspicious movement in a specific area.
Wired and Wireless Network Support.(ICA-100W only)
ICA-100W provides both wired and wireless function. You can use ICA-100W in different LAN environment by simple mode switching.
Package Contents
The following items should be included:
• Internet Camera unit
• Camera Stand Accessory
• Power Adapter
• CD-ROM
• Quick Installation Guide
• Wireless Antenna*2 (ICA-100W only)
If any of the above items are damaged or missing, please contact your dealer immediately.
Physical Details
Front Panel
Power LED
LAN LED
Figure 1-1: Front Panel
Power LED
The Power LED is positioned on the right side of ICA-100 series’s lens while facing
ICA-100 series. Steady blue confirms ICA-100 series is powered on.
LAN ( /WLAN ) LED
The LAN ( /WLAN ) LED is positioned on the far right side of ICA-100 series’s lens
while facing ICA-100 series. It is located right of the Power LED. Steady orange confirms good connection to LAN or WLAN connectivity. Dependent on the data traffic the
LED will begin to flash to indicate ICA-100 series is receiving/ transferring from/to the
LAN or WLAN network.
Note:
2
Introduction
There are three settings for the Power and LAN ( /WLAN ) LED to control the light
illumination for monitoring purpose from Normal / Off / Dummy. Please refer to the
Web Configuration section for detailed information and usage.
Rear Panel
Figure 1-2: Rear panel of ICA-100
Figure 1-3: Rear panel of ICA-100W
Network Cable Connector
Internet Camera provides an RJ-45 connector for connections to 10Base-T Ethernet
cabling or 100Base-TX Fast Ethernet cabling (which should be Category 5 twisted-pair
cable). The port supports the NWay protocol, allowing ICA-100 series to automatically
detect or negotiate the transmission speed of the network.
DC Power Connector
The DC power input connector is located on ICA-100 series’s rear panel and is labeled
DC 5V with a single jack socket to supply power to ICA-100 series. Power will be
generated when the power supply is connected to a wall outlet.
Reset Button
Reset will be initiated when the reset button is pressed once and Power LED begins to
flash.
Factory Reset of ICA-100: Press the reset button for three seconds or until Power LED
3
Broadband Router User Guide
begins to light up, then release the reset button and the Power LED will begin to flash
indicating ICA-100 is changing to factory reset. When factory reset is completed the IP
address will return to the default setting as 192.168.0.20.
Factory Reset of ICA-100W: Press the reset button for three seconds or until Power
LED begins to light up, then release the reset button and the Power LED will begin to
flash indicating ICA-100W is changing to factory reset. When factory reset is completed ICA-100W will be set to default on channel 11 and EES-ID is set as “NULL
String” (This default setting will let ICA-100W able to connect ANY access point on the
infrastructure network). The IP address will also return to the default setting as
192.168.0.20.
I/O Connector
There are four I/O connectors, two for input and two for output situated on the rear
panel. The I/O connectors provide the physical interface to send and receive digital
signals to a variety of external alarm devices. Please refer to the User’s Guide appen-dix for detailed information.
Slide Switch( ICA-100W only)
The slide switch permits user to determine the type of network communication media
for ICA-100W and is positioned on the rear panel. The three settings are as follows:
· LAN (Local Area Network)
· LAN/WLAN (Local Area Network/Wireless Local Area
Network)
· WLAN (Wireless Local Area Network)
Antenna Connector( ICA-100W only)
There are two Reverse Polarity SMA type antenna connectors located at the rear panel
of ICA-100W providing connection for two high sensitivity antenna included with the
device. You can also install the antenna with higher dB gain to get longer distance
connection. However, only antenna connector above the DC power connector is used
to transmit wireless signal. Thus, only connect the high dB gain antenna to this connector. The other one should still connect with bundled antenna.
Top Panel
Figure 1-4:Top Panel of ICA-100
4
Introduction
Figure 1-5:Top Panel of ICA-100W
Screw Hole
Located on the top panel of ICA-100 series, the screw hole is used to connect the
camera stand onto ICA-100 series by attaching the screw head on the camera stand
into the screw hole of ICA-100 series.
Bottom Panel
Figure 1-6 Bottom Panel
Screw Hole
Located on the bottom panel of ICA-100 series the screw hole is used to connect the
camera stand onto ICA-100 series by attaching the screw head on the camera stand
into the screw hole of ICA-100 series.
.
5
2
Chapter 2
Installation
This Chapter covers the physical installation of ICA-100 Series.
Requirements
ICA-100 ICA-100W
Network Environment
LAN
Monitoring System Recommended to Access ICA-100 series
System Hardware
Web Browser
System Requirement for IPView Application
Support OS
System Hardware
10/ 100M Ethernet 10/ 100M Ethernet
IEEE 802.11b Wireless LAN
• CPU: Pentium II, 266 MHz or above
• Memory Size: 32 MB (64 MB recommended)
• VGA card resolution: 800x600 or above
• Internet Explorer 5.0 or above (ActiveX & JAVA Mode –
Image View for Windows OS and JAVA Mode – Image
View for other OS)
• Netscape 6.0 or above (JAVA Mode – Image View)
Win 98, Win 98 SE, Win 2000, Win Me, Win XP
• CPU: Pentium III, 450 MHz or above
• Memory Size: 128 MB (256 MB recommended)
• VGA card resolution: 800x600 or above
Connecting ICA-100 series to the Camera Stand
ICA-100 series comes with a camera stand accessory with a swivel ball screw head
that can be attached to ICA-100 series 's top or bottom screw hole. Attach the camera
stand to ICA-100 series and station it for your application. There are three holes located in the base of the camera stand allowing ICA-100 series to be mounted on the
ceiling or any wall securely.
6
Installation
Figure 2-1: Camera Stand
Hardware Install Procedure
ICA-100
1.Connect an Ethernet cable
Connect one end of an Ethernet cable to the LAN port located on the ICA-100 rear
panel and attach the other end to the network device (hub or switch).
2.Attach the external power supply
Connect the provided power adapter to the ICA-100’s connector labeled "5VDC" on
rare panel.
3.Check the LEDs
The PWR and ACT LEDs should be on.
ICA-100W
1.Attach Wireless Antenna (LAN+WLAN or WLAN mode)
Screw the 2 external Antenna provided into the antenna connector located on ICA100W’s rear panel.
2.Connect an Ethernet cable (LAN or LAN+WLAN mode)
Connect one end of an Ethernet cable to the LAN port located on the ICA-100W’s rear
panel and attach the other end to the network device (hub or switch).
3.Switch to appropriate network type
Select the desired Network communication type for ICA-100W from the Slide Switch.
Position the Slide Switch to the setting required.
4.Attach the external power supply
Connect the provided power adapter to the ICA-100W’s connector labeled "5VDC" on
rare panel.
5.Check the LEDs
The PWR and ACT LEDs should be on.
7
3
Chapter 3
Configuration
This Chapter provides details of the software configuration process.
Login
ICA-100 series must be configured through its built-in Web-based Configuration.
Extensive knowledge of LAN will be helpful in setting up. From the web browser, type
http ://192.168.0.20 in the address box to access Home page of ICA-100 series.
If you can't connect
If ICA-100 series do not respond, check the following:
• Machine is properly installed, LAN or WLAN connection is OK, and it is
powered ON. You can test the connection by using the "Ping" command:
• Open the MS-DOS window or command prompt window.
• Enter the command:
ping 192.168.0.20
If no response is received, either the connection is not working, or
your PC's IP address is not compatible with ICA-100series’ IP Addresses. (See next item.)
• Ensure that your PC is using an IP Address within the range
192.168.0.1 to 192.168.0.254 (excluding 192.168.0.20).
Also, the Network Mask should be set to 255.255.255.0 to match ICA100 series.
In Windows, you can check these settings by using Control Panel-Network to check the Properties for the TCP/IP protocol.
Home Page
After the default IP address is entered from the browser, the Home page will appear
with a still image. There will be three options to choose from to set-up and view your
Internet Camera and they are as follows:
• View Image – ActiveX Mode
• View Image – Java Mode
• System Administration
8
PC Configuration
Figure 3-1:Home Page
System Administration
Click on “System Administration” from the Home page to access the settings required for ICA-100 series. There will be several options in the menu bar to choose
from to set your Internet Camera and they are as follows:
• System
• Image
• Users
• DateTime
• Trigger
• Upload
• Information
• Tools
System
The System menu contains commands for settings that are required for inputting key
details to set-up ICA-100 series for operation.
Click on "System" in the system administration menu bar and the System screen will
appear. The screen below is from ICA-100W; the screen of ICA-100 is the same but
has no “Wireless Interface” parameters.
9
Broadband Router User Guide
10
PC Configuration
Figure 3-2: System Screen of ICA-100W
Camera Name:
This field is used for entering a descriptive name for the device. The default setting for
the Camera Name is CS-xxxxxx, where xxxxxx is the last six digit of the MAC Address.
The maximum length is 32 (Printable ASCII).
Location:
This field is used for entering a descriptive name for the location used by ICA-100
series.
Admin:
This field is used for entering the Administrator ID along with the password to access
the System Administration settings. Be sure to enter the password twice to confirm the
details once in the Admin Password field and again in the Confirm Password field. The
default setting for Admin is blank space (Null String) you need to key in the Admin ID
with a maximum length of 12 (Printable ASCII) characters and enter the Admin Password with a maximum length of 8 (Printable ASCII) characters. Please note that Admin
ID and Admin Password must be set before using IPView utility to connect Internet
Camera; otherwise the Internet Camera can not be added to IPView.
IP Assignment:
There are two options to select from the IP Assignment.Note: Access to ICA-100 series is done through assigning a proper IP address. Please
make sure to use a vacant IP address when you assign the IP address for ICA-100
series. This will prevent errors from occurring if the IP address is overlapped.
Manually Assign
You can click “Manually Assign”and directly enter the IP address.
The default settings are as follows:
· Default IP – 192.168.0.20
· Subnet Mask – 255.255.255.0
· Default Gateway – 0.0.0.0
Assign Automatically Using
If your network is using RARP, BOOTP or DHCP server you can click “Assign
Automatically Using”and click on “RARP”, “BOOTP”or “DHCP”. Under this
setting ICA-100 series will automatically assign an IP address from RARP, BOOTP
or DHCP server. Each time ICA-100 series starts up be sure the RARP, BOOTP or
DHCP server is setup as assign a static IP to your Internet Camera. If your application requires direct connection from an ADSL modem through ICA-100 series’s RJ45 LAN port and you also have an ISP PPPoE account. Click on “PPPoE” option
and enter the Service Name, User ID and Password into the respective fields. ICA100 series will get an IP address from the ISP each time ICA-100 series starts up.
DNS IP Address:
DNS (Domain Name System) server is an Internet service that translates domain
names into IP addresses. Enter at least one DNS IP Address.
Dynamic DNS:
Click Yes/No to enable/disable DDNS function. Before you use this function, you must
register a hostname from a DDNS service provider first.
Service Provider
11
Broadband Router User Guide
Enter the URL of the DDNS service provider whom you registered to.
Host Name
Enter the hostname you registered.
User Name
Enter the user name that used to login the DDNS web site.
Password
Enter the password of your account.
Wireless Interface: (ICA-100W only)
Connection Mode:
Use the Connection Mode to determine the type of wireless communication for ICA100W. There are three choices of Infrastructure mode, 802.11 Adhoc mode and
Adhoc mode. The default setting for the Connection Mode is Infrastructure.
Note: Keep in mind after setting the Wireless Interface, making sure that the Slide
Switch on the rear panel is positioned to either LAN/WLAN or WLAN setting for the
wireless communication to take effect.
Network Name:
This field is used to setup which wireless network (ESS-ID Extended Service Set ID)
ICA-100W is to be connected for communication. The ESS-ID is a unique identifier
shared among all points in a wireless network environment. The default Network
Name is blank space (NULL String), this default setting will let ICA-100W connect
to ANY access point under the infrastructure network mode. To connect ICA-100W
to a specific access point on the network make sure to set the ESS-ID of ICA-100W
to correspond with the access point’s ESS-ID for communication. Type any string
up to 32 characters long (spaces, symbols, and punctuation are not allowed) in the
Network Name box.
To connect ICA-100W to an Ad-hoc wireless workgroup make sure to set the same
wireless channel and ESSID to match with the PC/Notebook wireless channel and
ESS-ID for direct wireless communication under the Ad-hoc wireless workgroup
(ad-hoc and 802.11 ad-hoc modes).
Note : ICA-100W ad-hoc mode supports two modes (802.11 ad-hoc mode and
proprietary ad-hoc mode). Which option should be chosen depends on which adhoc mode is supported by your wireless card driver on the PC/ Notebook. Some
driver supports both modes, however, some driver support only one of the modes.
The names of each ad-hoc mode may not be consistent between each wireless
card vendor therefore you may need to try each of the ad-hoc mode (802.11 mode
and proprietary mode) and select the mode that can communicate with each other.
Wireless Channel:
The pull down menu provides the wireless channel for communication. A "channel"
is a range of frequencies to be used in communication between ICA-100W and Access Point in infrastructure mode or ICA-100W and PC/Notebook in Ad-hoc mode.
Select the appropriate channel from the list provided depending on the regulatory
region that the unit is sold. The default setting is at channel 11.
Encryption WEP Key:
Wireless network communications are easily intercepted. WEP (Wired Equivalent
Privacy) is an encryption method specified by the IEEE 802.11b standard to make
any intercepted communications extremely difficult to interpret by unauthorized parties. To enable WEP Encryption, first decide which WEP key format will be applied.
12
PC Configuration
Click on ASCII or HEX check box to select input format as ASCII format or HEX
format, and then input WEP key. To Confirm the WEP key you must enter the data
once again in the Confirm WEP Key field.
ASCII input format:
ASCII format causes each character to be interpreted as an eight-bit value. All
unaccented upper- and lower-case Western European characters that can be
input through your keyboard's typing zone are valid. To setup 64-bit WEP key,
input 5 ASCII characters, for example, ‘12345’. To setup 128-bit WEP key, input
13 ASCII characters, for example, ‘1234567890123’. These character counts
result in bit counts of 40 and 104, respectively; ICA-100W will automatically pad
your input to a bit count of 64 or 128.
HEX input format:
Hex format causes each pair of characters you type to be interpreted as an
eight-bit value in hexadecimal (base 16) notation. Only the digits 0 through 9 and
the letters A through F (in upper or lower case) are valid. To setup 64-bit WEP
key, input 10 HEX format, for example, ‘3132333435’, this is the same with
ASCII input ‘12345’. To setup 128-bit WEP key, input 26 HEX format, for example, ‘31323334353637383930313233’, this is the same with ASCII input ‘1234567890123’. These character counts result in bit counts of 40 and 104, respectively; ICA-100W will automatically pad your input to a bit count of 64 or 128.
On the Confirm WEP Key field, input the same characters as the Encryption
Code field. Make sure the Encryption Code is the same with the access point’s
encryption code that ICA-100W is to be connected under Infrastructure mode.
Your PC/Notebook’s encryption code also needs to be setup the same with ICA100W's encryption code under either Infrastructure mode or Ad-hoc mode.
The default setting for the Encryption Key is Disable therefore, to secure the
wireless transmission be sure to Enable the Encryption Key by entering the relevant data.
Note: Carefully input Encryption Code, any error setting will cause communication link to fail.
LED Control:
The LED control allows user to setup the LED illumination as desired. This feature
provides the flexibility when surveillance activity is ON.
There are three options as follows:
Normal
Power - Steady On of the LED indicator.
LAN - Steady On of the LED indicator. When LAN activity is present the LED indica-
tor will flash steadily.
OFF
Power - LED indicator is off
LAN - LED indicator is off
Dummy
Power - Steady On of the LED indicator.
LAN - Steady On of the LED indicator with random flashing.
The default setting for the LED control is at Normal. When you have configured the
LED control the correct illumination will set in after 1 minute.
13
Broadband Router User Guide
Note: This function is built-in to the LED indicators to add extra capabilities. The three
options allow the Administrator to configure and camouflage the illumination for the
LED indicator to falsify the monitoring status. In Normal Mode the LED indicator functions as normally. Under Off Mode the LED indicators are both off however, it is still
monitoring the activity. In Dummy Mode the LED indicators operate in monitoring
condition but monitoring activity is off or on.
Loading ActiveX From:
This field is used to specify the location of Xplug Control (ActiveX) plug-in program.
Enter the information as required in .ocx format, for example: http://www.<your com-pany>.com/xplug.ocx where <your company> must be replaced with your company’s
DNS name.
Open Second Port:
The Web Server field allows settings to open a second port for ICA-100 series. This
will permit users IP Sharing Gateways to support multiple Internet Cameras. By default
Port 80 is always opened for ICA-100 series Web Server access. Select
“Yes” and input the second port value. For example: If you have 5 Internet Cameras
to be installed, each with an IP address from
192.168.0.101
192.168.0.102
192.168.0.103
192.168.0.104
192.168.0.105
You can open the second port for each Internet Camera from port 81 to Port 85 as
illustrated below:
Internet Camera 1 – IP 192.168.0.101, second web port 81
Internet Camera 2 – IP 192.168.0.102, second web port 82
Internet Camera 3 – IP 192.168.0.103, second web port 83
Internet Camera 4 – IP 192.168.0.104, second web port 84
Internet Camera 5 – IP 192.168.0.105, second web port 85
You also need to setup your DSL gateway for Port Mapping.
Port 81 map to 192.168.0.101
Port 82 map to 192.168.0.102
Port 83 map to 192.168.0.103
Port 84 map to 192.168.0.104
Port 85 map to 192.168.0.105
The Transfer Image field allows settings to open a second port for ICA-100 series to
transfer images. The default Port 8481 is open image transfer and you can define a
second port similar to the above.
Save/Cancel:
After making sure all settings in the System are correct, click on the “Save”icon to
store the settings for ICA-100 series. You can alternatively click on the “Cancel” icon
to restore all settings to the values last saved to or retrieved from ICA-100 series.
14
PC Configuration
Image
Image menu in the system administration contains commands to provide the settings
for the images captured by ICA-100 series. Click on “Image” in the system administration menu bar and the Image screen will appear as illustrated below:
Figure 3-3: Image Screen
Video Resolution:
Select the desired video resolution format ranging from 320x240 (default) or 640x480.
Compression Rate:
Select the desired compression rate with five levels from very low to very high. Higher
video compression rate will generate more compact file size with less video quality and
vise-versa. The default setting is at Medium.
Frame Rate:
Select the frame rate desired with default setting at Auto for optimal frame rate.
Brightness Control:
Adjust the brightness level with default setting at 64.
Contrast Control:
Adjust the contrast level with default setting at 64.
Hue Control:
Adjust the hue level with default setting at 64.
Light Frequency:
Adjust the light frequency to suit your area of operation from the options either 50 Hz
or 60 Hz (default).
Note: 50 Hz and 60 Hz variants are available to accommodate the different light
frequency found in USA (60 Hz) and Europe (50 Hz) for ICA-100 series to ensure
better image quality.
Save/Cancel:
15
Broadband Router User Guide
After making sure all settings in the Image are correct, click on the “Save”icon to
store the settings for ICA-100 series. You can alternatively click on the “Cancel” icon
to restore all settings to the values last saved to or retrieved from ICA-100 series.
Users
The User options menu contains commands to allow system administrator to assign
legal users who are permitted to monitor ICA-100 series from the remote site.
Click on “Users” in the system administration menu bar and the Users screen will
appear as illustrated below:
Figure 3-4: Users Screen
Add User:
User Name:
Enter the user name in this field. A maximum of 64 users names are allowed, however each users name must be different. Each user name can be used as a group
given the password for example, if the User Name is “Guest” and the User Password is “Guest” anyone can access ICA-100 series with these details used as a
group of users under the User Name Guest. The maximum length for the User
Name is 12 (Printable ASCII).
User Password:
Enter the user’s password assigned by the administrator. The maximum password
length is 8 (Printable ASCII).
I/O Output Control:
Administrator has the authority to give permission for the privilege to control the I/O
Output Control to user’s by selecting “Yes” or “No” to activate the I/O Output control.
To add a new users name input the necessary information first and click on the “Add”
icon.
Delete User:
Select the user you wish to delete from the pull down menu and click on the “delete”
icon.
Note: Once administrator has configured ICA-100 series Users, any user will be
required to enter a login password to access the video image of ICA-100 series.
The password dialog box is illustrated below.
16
PC Configuration
Figure 3-5: User Login Screen
DateTime
The DateTime menu contains commands for setting ICA-100 series' time and date
requirements to provide correct information to users who might be thousands of miles
away in the remote site. There are two options to select from the DateTime menu bar
either Synchronized with Time Server or Set Manually. Click on “DateTime” in the
system administration menu bar and the DateTime screen will appear as illustrated
below:
Figure 3-6: DateTime Screen
DateTime:
Select “Synchronized with Time Server” and the time will be based on GMT setting.
The time will be synchronized every 10 minutes. This is also the default setting for ICA100 series.
IP Address:
Enter the IP Address of the Time Server in this field.
17
Broadband Router User Guide
Note: Please find below NTP server web address for your reference to set the time
server.
http://www.eecis.udel.edu/~mills/ntp/clock1.htm
http://www.eecis.udel.edu/~mills/ntp/clock2.htm
Protocol:
Two options of NTP or Time are available for your selection to link with the Time
Server. The default setting is NTP.
TimeZone:
System administrator must select the time zone for the region. Please refer to the
appendix for the time zone selection table.
To set the Date Time manually select “Set Manually” and system administrator must
enter the Date and Time in the respective field manually.
Note: When you select Set Manually, each time ICA-100 series is powered off and
on you must re-enter the details once again due to time lost.
Save/Cancel:
After making sure all settings in the DateTime are correct, click on the “Save” icon to
store the settings for ICA-100 series. You can alternatively click on the “Cancel” icon
to restore all settings to the values last saved to or retrieved from ICA-100 series.
Trigger
The Trigger menu contains commands for the I/O Trigger connectors providing the
physical interface for 2 digital output and 2 digital input that is used for connecting a
diversity of external alarm devices to ICA-100 series such as IR-Sensor and alarm
relay. Click on “Trigger” in the system administration menu bar and the Trigger
screen will appear as illustrated below:
18
PC Configuration
Figure 3-7: Trigger Screen
The default setting for the I/O Trigger functions are disabled. You must enable the I/O
Trigger first before the Triggers will perform. There are two options to select from the
Trigger screen I/O Input 1 Trigger and I/O Input 2 Trigger.
I/O Input 1 Trigger:
Select “Send e-mail attached with image” and enter the relevant information such
as the SMTP Server Address, Sender e-mail Address, Receiver e-mail Address,
Sending Interval and Sending Times.
SMTP Server Address
SMTP(Simple Mail Transfer Protocol) is a protocol for sending e-mail messages
between servers. The mail server address must be filled in this field. If the SMTP
server needs authentication, ICA-100 series will use Admin ID and Admin Password entered in System page as login account and password.
Sender e-mail Address
The e-mail address of who will be sending the e-mail.
Receiver e-mail
The e-mail address of the person whom will receive the e-mail.
Sending Interval
19
Broadband Router User Guide
The period of time between each email being sent to the receiver. If the setting is at
10 seconds, a new e-mail will be sent in 10 seconds interval to the receiver.
Sending Time
The number of times the e-mail will be sent to the receiver before it terminates.
Select “Trigger I/O Output” and enter the setting for Output 1 time and Output 2 time
in seconds. These fields determine the duration for activating the external output
devices.
I/O Input 2 Triggersetting procedures are same as above.
Save/Cancel:
After making sure all settings in the System are correct, click on the “Save”icon to
store the settings for ICA-100 series. You can alternatively click on the “Cancel” icon
to restore all settings to the values last saved to or retrieved from ICA-100 series.
Please refer to the appendix for detailed information regarding the I/O Connector.
Warning
When connecting other devices through the I/O connectors, please make sure the
maximum current of 100mA is strictly observed. Any failure to do so might cause a
loss of power to ICA-100 series and possibly cause serious damage to ICA-100 series.
Upload
The Upload menu contains commands for setting ICA-100 series to upload images to
a specified FTP server, time scheduling, and manual operation. Click on “Upload” in
the system administration menu bar and the Upload screen will appear as illustrated
below:
Note: Before using the Upload function, please ensure the User account used has
“write” permission of the FTP server or the specified folder.
20
PC Configuration
Figure 3-8: Upload Screen
FTP Server:
Host Address:
Enter the IP address of target FTP server.
Port Number:
Most of the FTP servers using port 21. If the target FTP server uses specific port,
please ask the FTP server administrator to provide the information.
User Name:
Enter the user name used to login FTP server in this field.
Password:
Enter the password used to login FTP server in this field.
Directory Path:
21
Loading...
+ 56 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.