Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp. All
other trademarks belong to their respective owners.
Disclaimer
PLANET Technology does not warrant that the hardware will work
properly in all environments and applications, and makes no warranty
and representation, either implied or expressed, with respect to
the quality, performance, merchantability, or tness for a particular
purpose.
PLANET has made every effort to ensure that this User’s Manual is
accurate; PLANET disclaims liability for any inaccuracies or omissions
that may have occurred.
Information in this User’s Manual is subject to change without notice
and does not represent a commitment on the part of PLANET. PLANET
assumes no responsibility for any inaccuracies that may be contained in
this User’s Manual. PLANET makes no commitment to update or keep
current the information in this User’s Manual, and reserves the right
to make improvements to this User’s Manual and/or to the products
described in this User’s Manual, at any time without notice.
If you nd information in this manual that is incorrect, misleading, or
incomplete, we would appreciate your comments and suggestions.
FCC Warning
This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with
the Instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area
is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may
cause radio interference, in which case the user may be required to
take adequate measures.
WEEE Warning
To avoid the potential effects on the environment and human
health as a result of the presence of hazardous substances in
electrical and electronic equipment, end users of electrical and
electronic equipment should understand the meaning of the
crossed-out wheeled bin symbol. Do not dispose of WEEE as unsorted
municipal waste and have to collect such WEEE separately.
Revision
PLANET Industrial Power over Coaxial Extender Kit User's Manual
Thank you for purchasing PLANET Industrial Power over Coaxial
Extender Kit, the VC-205-KIT, consisting of the VC-205PT and
VC-205PR. The descriptions of the two models are as follows:
VC-205PT
VC-205PR
“Industrial Power over Coaxial Extender Kit” mentioned in this
Manual represents the above two models.
Open the box of the Industrial Power over Coaxial Extender Kit and
carefully unpack it. The box should contain the following items:
For VC-205-KIT
Industrial Power over Coaxial Extender – Transmitter x 1 l
Industrial Power over Coaxial Extender – Receiver x 1 l
User's Manual x 1 l
Warning Sticker x 1 l
If any of these are missing or damaged, please contact your dealer
immediately; if possible, retain the carton including the original packing
material, and use them again to repack the product in case there is a
need to return it to us for repair.
1.2 Product Features
Physical Port
Model
Name
VC-205PT1 x 10/100Base-TX (PoE IN)Power Transmitter
VC-205PR1 x 10/100Base-TX (PoE OUT) Power Receiver
CopperBNC
Ports
5
Power over Ethernet
Eliminates Power cabling with PoE over Coaxial l
Ethernet over coaxial up to 1km with 5C2V/RG6 75Ω cablel
Complies with IEEE 802.3af / IEEE 802.3at Power over Ethernet on l
RJ-45 ports
Supports PoE Power up to 30.8 watts (Vary on Power Source and l
Coaxial Distance)
Auto detect powered device (PD) (VC-205PR) l
Layer 2 Features
Supports Auto-negotiation and 10/100Mbps half / full duplex mode l
Prevents packet loss with back pressure (Half-Duplex) and IEEE l
802.3x PAUSE frame ow control (Full-Duplex)
VDSL2 Features
Denes Symmetric Band Plans for the transmission of Upstream and l
Downstream signals
Industrial Case / Installation
Supports extensive LED indicators for network diagnostics l
IP30 metal case protection l
Compact size, DIN Rail and Wall Mount Design l
Power Input: External DC or PoE power input (VC-205PT) l
Power Output: PoE power output (VC-205PR) l
Supports EFT protection 2000 VDC for power line l
Supports 2000 VDC Ethernet ESD protection l
-10 to 60 degrees C operating temperature l
6
1.3 ProductSpecications
ModelVC-205PTVC-205PR
Hardware Specications
10/100Base-TX RJ-45
Copper
Interface
Coaxial
DC Socket
(Optional)
LED Indicators
ESD Protection2KV DC
EFT Protection2KV DC
EnclosureIP30 metal case
InstallationWall mount or DIN rail with optional kit
BNC
44~57V DC
(depending on what the
DC/PoE Power Input is)
RJ-45, both Mid-Span and
End-Span
Input Range: 44~57V DC
BNC : 25 wattsRJ-45 : 20 watts
IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX Fast Ethernet
IEEE 802.3af Power over Ethernet (802.3at Type 1)
IEEE 802.3at Power over Ethernet Plus (802.3at Type 2)
Operating: -10~60 degrees C
Storage: -20~70 degrees C