Planet IGS-510TF operation manual

1. Package Contents
Thank you for purchasing PLANET industrial compact 5-port Gigabit Ethernet Switch, IGS-500T/IGS-510TF. In the following section, the term “Industrial Gigabit Ethernet Switch” means the IGS-500T or IGS-510TF.
Open the box of the Industrial Gigabit Ethernet Switch and carefully unpack it. The box should contain the following items:
Ethernet Switch x 1
DIN-rail Kit x 1 RJ45 Dust Caps
If any of these are missing or damaged, please contact your dealer immediately; if possible, retain the carton including the original packing material, and use them again to repack the product in case there is a need to return it to us for repair.
User’s Manual x 1 Wall-mount Kit x 1
SFP Dust Cap x 1
(IGS-510TF only)
IGS-500T x 5
IGS-510TF x 4
Power Consumption (Ethernet Full
Max. 3.6 watts/12.28BTU
Max. 4.3 watts/14.67BTU
Loading)
Dimensions (W x D x H)
30 x 70 x 104 mm
Weight 252g 270g
Enclosure IP30 metal case
Installation DIN-rail kit and wall-mount kit
ESD Protection 6KV
EFT Protection 6KV
Switch Specications
Switch Architecture
Store-and-Forward
Switch Fabric 10Gbps
Throughput (packet per
7.4Mpps@64bytes
second)
Address Table 4K entries
Buer Memory 1M bits on-chip buer memory
Jumbo Frame 9Kbytes
Flow Control
Back pressure for half duplex IEEE 802.3x pause frame for full duplex
3. Hardware Introduction
3.1 Switch Front Panel
The front Panels of the Industrial Gigabit Ethernet Switches consist of Ethernet interfaces and LED indicators.
Front View
P1 P2
P1 P2 Fault
ACTLNK
ACTLNK
1000
1000
10/
100
1000
10/
100
LNK/
100
ACT
ACTLNK
IGS-510TF
IGS-500T
1
1
2
2
3
3
4
4
5 5
Figure 1:
IGS-500T Front View
P1 P2
ACTLNK
1000
10/
100
1000
10/
100
LNK/ ACT
1
2
3
4
5
IGS-510TF
Figure 2:
IGS-510TF Front View
1 2 3 4
V1+
V2+
V1-
V2-
DC Input: 9-48V , 0.6A max.
PWR1
PWR2
AC Input: 24V , 0.3A max.
Figure 4: IGS-510TF Top View
3.4 Wiring the Power Inputs
The terminal block connector on the top panel of Industrial Gigabit Ethernet Switch is used for two DC redundant power inputs. Please follow the steps below to insert the power wire.
When performing any of the procedures like inserting the wires or tightening the wire-clamp screws, make
Caution
[IGS-500T]
1. Insert positive and negative DC power wires into contacts 1 and 2 for POWER 1, or contacts 5 and 6 for POWER 2.
sure the power is OFF to prevent from getting an electric shock.
Max. fault loading: 24V, 1A
1 2 3 4 5 6
V1+
PWR1
V2+
PWR2Fault
DC Input: 12-48V AC Input: 24V
, 0.3A max.
, 0.28A max.
- 1 -
2.ProductSpecications
Model IGS-500T IGS-510TF
Hardware Specications
4 10/100/1000BASE-T RJ45 auto-MDI/MDI-X ports
1 1000BASE-SX/LX/ BX SFP interface compatible with 100BASE-FX SFP
Removable 4-pin terminal block Pin 1/2 for Power 1; Pin 3/4 for Power 2
--
9~48V DC, redundant power with reverse polarity protection function, 24V AC power support
Copper Ports
SFP Slot --
Connector
Alarm
Power Requirements
5 10/100/1000BASE-T RJ45 auto-MDI/MDI-X ports
Removable 6-pin terminal block Pin 1/2 for Power 1; Pin 3/4 for fault alarm; Pin 5/6 for Power 2
One relay output for power failure. Alarm relay current carry ability: 1A@DC 24V
12~48V DC, redundant power with reverse polarity protection function, 24V AC power support
Standards Conformance
Regulatory Compliance
FCC Part 15 Class A, CE
IEC 60068-2-32 (free fall)
Stability Testing
IEC 60068-2-27 (shock) IEC 60068-2-6 (vibration)
IEEE 802.3 Ethernet IEEE 802.3u Fast Ethernet
Standards Compliance
IEEE 802.3ab Gigabit Ethernet IEEE 802.3az Gigabit SX/LX (IGS-510TF only) IEEE 802.3x Full-Duplex Flow Control
IEEE 802.3az Energy Ecient Ethernet (EEE)
IEEE 802.1p Class of Service
Environment
Temperature
Humidity
Operating: -40~75 degrees C Storage: -40~75 degrees C
Operating: 5~90% (non-condensing) Storage: 5~90% (non-condensing)
- 3 -
- 5 -
3.2 LEDDenition:
LED Color Function
P1 Green Lights to indicate power input 1 has power.
P2 Green Lights to indicate power input 2 has power.
Fault Red
Lights to indicate that power 1 or power 2 has failed. (For IGS-500T only)
Lights to indicate the port is running at
1000 LNK/ACT
Green
1000Mbps speed and successfully established.
Blinks to indicate that the Switch is actively sending or receiving data over that port.
Lights to indicate the port is running
100 LNK/ACT
Amber
at 10/100Mbps speed and successfully established.
Blinks to indicate that the Switch is actively sending or receiving data over that port.
3.3 Switch Upper Panel
The upper panels of the Industrial Gigabit Ethernet Switches consist of one terminal block connector within two power input.
Max. fault loading: 24V, 1A
1 2 3 4 5 6
V1+
PWR1
V2+
PWR2Fault
DC Input: 12-48V AC Input: 24V
, 0.3A max.
, 0.28A max.
Figure 3: IGS-500T Top View
- 7 -
2. Tighten the wire-clamp screws for preventing the wires from loosening.
1 2 3 4 5 6
Power 1 Fault Power 2
+ - + -
[IGS-510TF]
1. Insert positive and negative DC power wires into contacts 1 and 2 for POWER 1, or contacts 3 and 4 for POWER 2.
1 2 3 4
V1+
V2+
V1-
V2-
DC Input: 9-48V , 0.6A max.
PWR1
PWR2
2. Tighten the wire-clamp screws for preventing the wires from loosening.
1 2 3 4
Power 1 Power 2
+ - + -
AC Input: 24V , 0.3A max.
- 2 -
- 4 -
- 6 -
- 8 -
Note
Top View
The wire gauge for the terminal block should be in the range between 12 and 24 AWG.
4.1 DIN-rail Mounting Installation
1
1. The power input range is 12V ~ 48V DC for IGS­500T, 9 ~ 48V DC for IGS-510TF and supports 24V
Note
AC.
2. Use one power input when using 24V AC.
3.5 Wiring the Fault Alarm Contact (IGS-500T Only)
The fault alarm contacts are in the middle of the terminal block connector as the picture shows below. Inserting the wires, the Industrial Gigabit Ethernet Switch will detect the fault status of the power failure and then forms an open circuit. The following illustration shows an application example for wiring the fault alarm contacts.
1 2 3 4 5 6
The Fault Alarm Contacts are energized (CLOSE) for normal
Fault Alarm Contacts
Note
Fault
1. The wire gauge for the terminal block should be in the range between 12 and 24 AWG.
2. Alarm relay circuit accepts up to 24V DC, 1A.
operation and will OPEN when failure occurs
2
4.2 Wall-mount Plate Mounting
4.3 Side Wall-mount Plate Mounting (IGS-510TF Only)
You must use the screws supplied with the wall­mounting brackets. Damage caused to the parts by
Caution
using incorrect screws would invalidate your warranty.
- 9 -
3.6 Grounding the Device
Users MUST complete grounding wired with the device; otherwise, a sudden lightning could cause fatal damage to the device.
Earth Ground
1 2 3 4
V1+
V2+
V1-
V2-
DC Input: 9-48V , 0.6A max. AC Input: 24V , 0.3A max.
Note
PWR1
PWR2
EMD (Lightning) DAMAGE IS NOT CONVERED UNDER WARRANTY.
4. Installation
This section guides you to installing the Industrial Gigabit Ethernet Switch on the DIN rail and wall. Please read this chapter completely before continuing.
- 11 -
5. Three-View Diagram
The three-view diagram of the Industrial Gigabit Ethernet Switch consists of multiple auto-sensing 10/100/1000BASE-T RJ45 ports and one removable terminal block. The LED indicators are also located on the front panel.
IGS-500T
V1+
Max. fault loading: 24V, 1A
PWR1
V2+
PWR2Fault
DC Input: 12-48V
AC Input: 24V
, 0.3A max.
, 0.28A max.
Mounting Kit
9.00
91.00
18.00
28.00
18.00
Mounting Kit
40.00
48.80
40.00
DIN-Rail Kit
Front View
P1 P2 Fault
ACTLNK
1000
1
2
100
ACTLNK
IGS-500T
30.00
Bottom View
104.00
3
4
5
70.00
30.00
50.00
Rear ViewSide View Side View
52.00
52.00
21.69
28.65
18.00
IGS-510TF
30.00
50.00
Top View
V1+
PWR1
V1-
V2+
PWR2
V2-
DC Input: 9-48V , 0.6A max.
AC Input: 24V , 0.3A max.
Mounting Kit
9.00
18.00
91.00
28.00
18.00
Mounting Kit
Front View
P1 P2
ACTLNK
1000
10/ 100
1000
10/ 100
LNK/ ACT
IGS-510TF
30.00
Bottom View
Rear ViewSide View Side View
30.16
1
2
104.00
3
4
5
70.00
52.00
52.00
21.69
28.65
18.00
Figure 6: IGS-510TF Three-View Diagram
40.00
48.80
40.00
Customer Support
Thank you for purchasing PLANET products. You can browse our
online FAQ resource on PLANET web site rst to check if it could
solve your issue. If you need more support information, please contact PLANET switch support team.
PLANET online FAQs: http://www.planet.com.tw/en/support/faq
Switch support team mail address: support@planet.com.tw
DIN-Rail Kit
Unit: mm
Note
This following pictures show how to install the device. However, the device in the picture is not IGS-500T or IGS-510TF.
- 10 -
Figure 5: IGS-500T Three-View Diagram
- 12 - - 13 - - 14 -
Unit: mm
Copyright © PLANET Technology Corp. 2019. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.
Loading...