Thank you for purchasing PLANET industrial 8-Port 10/100TX 802.3at PoE+ + 2-Port
Gigabit TP/SFP combo Ethernet Switch, IFGS-1022HPT. In the following section, the
term “Industrial PoE+ Switch” means the IFGS-1022HPT.
Open the box of the Industrial PoE+ Switch and carefully unpack it. The box
should contain the following items:
Industrial PoE+ Switch x 1User’s Manual x 1
DIN Rail Kit x 1Wall-mount Kit x 1
If any of these are missing or damaged, please contact your dealer immediately;
if possible, retain the carton including the original packing material, and use them
again to repack the product in case there is a need to return it to us for repair.
3
Page 4
2. Hardware Introduction
2.1 Physical Dimensions
Dimensions (W x D x H): 161 x 107 x 72mm
Front View
DIPON
1
Long Reach Mode
2
3
4 5 6 7 8
Standard
Extended
P1 P2 FAULT
910
7
5
3
1
802.3at PoE+
LNK
1000
109
8
6
4
LNK
2
PoE In-Use
IFGS-1022HPT
Side View
Top View
ACT
1A@24V
DC1DC2
Input DC 48V~56V
Fault
Side View
ACT
Bottom View
Dimensions ( unit = mm )
4
Page 5
2.2 Switch Front Panel
The front panel of the Industrial PoE+ Switch consists of 8 10/100/BASE-TX ports
featuring 30-watt 802.3at PoE+, and 2 additional Gigabit copper/SFP combo
interfaces for Gigabit Ethernet extension and video uplink. The LED indicators are
also located on the front panel of the Industrial PoE+ Switch.
Figure 2-1 shows the front panel of Industrial PoE+ Switch.
DIPON
1
Long Reach Mode
2
3
4 5 6 7 8
Standard
Extended
P1 P2 FAULT
910
ACT
LNK
1000
109
7
5
3
1
802.3at PoE+
8
6
4
LNK
ACT
2
PoE In-Use
IFGS-1022HPT
Figure 2-1: IFGS-1022HPT Front Panel
Fast Ethernet TP interfaces (Port 1 to port 8)
10/100BASE-TX copper, RJ45 twisted-pair: Up to 100 meters.
Gigabit TP Interfaces (Port 9 to port 10 TP/SFP Combo Interfaces)
10/100/1000BASE-T copper, RJ45 twisted-pair: Up to 100 meters.
Gigabit SFP Slots (Port 9 to port 10 TP/SFP Combo Interfaces)
The Industrial PoE+ Switch has a built-in solid DIP switch that provides
“Standard” and “Extend” operation modes. The Industrial PoE+ Switch operates
as a normal IEEE 802.af/at PoE+ Switch in the “Standard” operation mode.
In the “Extend” operation mode, the Industrial PoE+ Switch operates on a perport basis at 10Mbps full duplex operation but can support 30-watt PoE power
output over a distance of up to 250 meters overcoming the 100m limit on Ethernet
UTP cable. With this brand-new feature, the Industrial PoE+ Switch provides an
additional solution for 802.3af/at PoE+ distance extension.
Default PoE Mode
PoE
100 meters (328 feet)
Extended PoE Mode
PoE
250 meters (820 feet)
PoE IP
Camera
PoE
PoE IP
Camera
100BASE-TX UTP with PoE
6
Page 7
2.3 LED Indicators
System
LEDColorFunction
P1Green Lit: indicates power 1 has power.
P2Green Lit: indicates power 2 has power.
FAULTRedLit: indicates neither power 1 or power 2 has no power.
Per 802.3at PoE+ 10/100BASE-TX Interface (Port 1 to Port 8)
LEDColorFunction
Lit: indicates the link through that port is successfully
LNK/
ACT
PoE
In-Use
Per 10/100/1000BASE-T Interface (Shared with Port 9 to Port 10)
LEDColorFunction
LNK/
ACT
1000Orange
Green
Orange
Green
established at 10Mbps or 100Mbps.
Blinking: indicates that the switch is actively sending or
receiving data over that port.
Lit: indicates the port is providing DC in-line power.
Off: indicates the connected device is not a PoE powered device
(PD).
Lit: indicates the link through that port is successfully
established at 10/100/1000Mbps.
Blinking: indicates that the switch is actively sending or
receiving data over that port.
Lit: indicates the link through that port is successfully
established at 1000Mbps.
Off: indicates the link through that port is successfully
established at 10/100Mbps.
Per 1000X SFP Slot (Shared with Port 9 to Port 10)
LEDColorFunction
Lit: indicates the link through that port is successfully
LNK/
ACT
1000Orange
Green
established at 1000Mbps.
Blinking: indicates that the switch is actively sending or
receiving data over that port.
Lit: indicates the link through that port is successfully
established at 1000Mbps.
Off: indicates the link through that port is not established.
7
Page 8
2.4 Switch Upper Panel
The upper panel of the Industrial PoE+ Switch consists of one terminal block
connector within two DC power inputs.
Figure 2-2 shows the upper panel of the Industrial PoE+ Switch.
1A@24V
1 2 3 4 5 6
DC1DC2
Fault
Input DC 48V~56 V
Figure 2-2: Industrial PoE+ Switch Upper Panel
2.5 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of Industrial PoE+ Switch
is used for two DC redundant power inputs. Please follow the steps below to insert
the power wire.
When performing any of the procedures like inserting the wires or
tightening the wire-clamp screws, make sure the power is OFF to
prevent from getting an electric shock.
1. Insert positive and negative DC power wires into contacts 1 and 2 for POWER 1,
or 5 and 6 for POWER 2.
1A@24V
1 2 3 4 5 6
DC1DC2
Fault
Input DC 48V~56 V
8
Page 9
2. Tighten the wire-clamp screws for preventing the wires from loosening.
123456
Power 1FaultPower 2
+-+-
1. The wire gauge for the terminal block should be in the range
between 12 and 24 AWG.
Note
2. The DC power input range is 48V ~ 56V DC.
2.6 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block connector as the
picture shows below. Inserting the wires, the Industrial PoE+ Switch will detect
the fault status of the power failure and then forms an open circuit. The following
illustration shows an application example for wiring the fault alarm contacts.
Note
The Fault Alarm Contacts are
energized (CLOSE) for normal
Fault Alarm Contacts
Fault
operation and will OPEN when
failure occurs
Insert the wires into the fault alarm contacts
1. The wire gauge for the terminal block should be in the range
between 12 and 24 AWG.
2. Alarm relay circuit accepts up to 30V, max. 3A currents.
9
Page 10
2.7 Product Features
Physical Port
Eight 10/100BASE-TX Fast Ethernet RJ45 ports with IEEE 802.3at/af
PoE+ Injector (Port-1 to Port-8)
Two 10/100/1000BASE-T Gigabit Ethernet RJ45 ports (Port-9 and Port-10)
Two 1000BASE-X mini-GBIC/SFP slots for SFP type auto detection (Port-9
and Port-10)
Power over Ethernet
Complies with IEEE 802.3at Power over Ethernet Plus, end-span PSE
Backward compatible with IEEE 802.3af Power over Ethernet
Up to 8 ports of IEEE 802.3af/802.3at devices powered
240-watt PoE budget
Supports PoE power up to 30 watts for each PoE port
Auto detects powered device (PD)
Circuit protection prevents power interference between ports
Remote power feeding up to 100 meters
Industrial Case and Installation
IP30 metal case
DIN rail and wall-mount design
48~56V DC, redundant power with polarity reverse protect function
Hardware DIP switch for “Standard” and “Extend” mode selection; the
“Extend” mode features 30-watt PoE transmit distance of 250m at speed of
10Mbps
Automatic address learning and address aging
Supports CSMA/CD protocol
10
Page 11
2.8 ProductSpecications
ProductIFGS-1022HPT
HardwareSpecications
Fast Ethernet Copper Ports
Gigabit Ethernet Copper Ports
SFP/mini-GBIC Slots
PoE Injector Port
Switch ArchitectureStore-and-Forward
Switch Fabric5.6Gbps/non-blocking
Switch Throughput@64 bytes 4.1Mpps @64 bytes
MAC Address Table16K entries
Shared Data Buffer4Mb SRAM
Flow Control
Jumbo Frame10 Kbytes
DIP Switch (Port 1 to port 8)
Eight 10/100BASE-TX RJ45 auto-MDI/MDI-X ports
(Port-1 to Port-8)
Two 10/100/1000BASE-T RJ45 auto-MDI/MDI-X
ports (shared with Port-9 and Port-10)
Two 1000BASE-SX/LX/BX SFP interfaces (shared
with Port-9 and Port-10)
Eight ports with 802.3af/802.3at PoE+ injector
function (Port-1 to Port-8)
IEEE 802.3x pause frame for full-duplex. Back
pressure for half-duplex
Standard mode: 30-watt PoE transmit distance of
100m at speed of 10/100Mbps
Extend mode: 30-watt PoE transmit distance of
250m at speed of 10Mbps
LED
3 x LED for System and Power:
Green: DC Power 1
Green: DC Power 2
Red: Power Fault Alarm
2 x LED for PoE Copper Port (Port-1~Port-8):
Green: LNK/ACT (10/100Mbps)
Orange: PoE-In-Use
2 x LED for 10/100/1000T Copper Port
(Port-9~Port-10):
Green: LNK/ACT
Orange: 1000
2 x LED for per mini-GBIC interface
(Port-9~Port-10)
Green: LNK/ACT
Orange: 1000
11
Page 12
Removable 6-pin terminal block
Connector
Alarm
Power Requirements
Power Consumption/
Dissipation
Dimensions (W x D x H)72 x 107 x 161 mm
Weight1034g
ESD Protection6KV DC
EnclosureIP30 aluminum case
InstallationDIN-rail kit and wall-mount kit
Power over Ethernet
PoE StandardIEEE 802.3at Power over Ethernet Plus/PSE
PoE Power Supply TypeEnd-span
Power Pin Assignment1/2(+), 3/6(-)
PoE Power Output
PoE Power Budget
Max. Number of Class 2 PDs8
Max. Number of Class 3 PDs8
Max. Number of Class 4 PDs8
Standards Conformance
Regulatory ComplianceFCC Part 15 Class A, CE
Pin 1/2 for Power 1
Pin 3/4 for power fault alarm
Pin 5/6 for Power 2
One relay output for power failure.
Alarm relay current carry ability: 1A @ 24V AC
48~56V DC, 5.5A (max.)
(>51V DC for PoE+ output recommended)
19 watts, 64BTU (Standby without PoE function)
at DC 56V power input
23 watts, 78BTU (Full loading without PoE
function) at DC 56V power input
244 watts, 832BTU (Full loading with PoE function)
at DC 56V power input
IEEE 802.3af Standard
- Per port 48V~51V DC (depending on the power
supply), max. 15.4 watts
IEEE 802.3at Standard
- Per port 51V~56V DC (depending on the power
supply), max. 30 watts
Dual power input: maximum 240W (depending on
power input)
12
Page 13
IEC 60068-2-32 (free fall)
Stability Testing
Standards Compliance
Environment
Operating Temperature-40 ~ 75 degrees C
Storage Temperature-40 ~ 85 degrees C
Humidity5 ~ 95% (non-condensing)
IEC 60068-2-27 (shock)
IEC 60068-2-6 (vibration)
IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX
IEEE 802.3ab Gigabit 1000BASE-T
IEEE 802.3z Gigabit SX/LX
IEEE 802.3x Flow Control and Back Pressure
IEEE 802.3af Power over Ethernet
IEEE 802.3at Power over Ethernet Plus
13
Page 14
3. Installation
This section describes the functionalities of the Industrial PoE+ Switch’s
components and guides how to install it on the DIN-rail and wall. Basic knowledge
of networking is assumed. Please read this chapter completely before continuing.
This following picture is telling the user how to install the device,
Note
3.1 DIN-rail Mounting Installation
The DIN-rail is screwed on the Industrial PoE+ Switch when out of factory. When
replacing the wall-mount application with DIN-rail application, Industrial PoE+
Industrial PoE+ Switch. To hang the Industrial PoE+ Switch, follow the following
steps:
Step 1: Screw the DIN-rail on the Industrial PoE+ Switch.
and the device is not IFGS-1022HPT.
14
Page 15
Step 2: Lightly insert the bottom of the switch into the track.
1
2
Step 3: Make sure if the DIN-rail is tightly secured on the track.
Step 4: Please refer to the following procedures to remove the Industrial PoE+
Switch from the track.
1
2
Step 5: Lightly pull out the bottom of the switch for removing it from the track.
15
Page 16
3.2 Wall-mount Plate Mounting
To install the Industrial PoE+ Switch on the wall, please follow the instructions
described below.
Step 1: To remove the DIN-Rail from the Industrial PoE+ Switch, loosen the
screws to remove the DIN-rail.
Step 2: Place the wall mount plate on the rear panel of the Industrial PoE+
Switch.
Step 3: Use the screws to screw the wall mount plate on the Industrial PoE+
Switch.
Step 4: Use the hook holes at the corners of the wall mount plate to hang the
Industrial PoE+ Switch on the wall.
Step 5: To remove the wall mount plate, reverse the steps above.
16
Page 17
3.3 Installing the SFP Transceiver
The sections describe how to insert an SFP transceiver into an SFP slot.
The SFP transceivers are hot-pluggable and hot-swappable. You can plug in and
out the transceiver to/from any SFP port without having to power down the
Industrial PoE+ Switch as Figure 2-3 shows.
MGB Series
Transceiver
Figure 2-3: Plug-in the SFP Transceiver
PLANET Industrial PoE+ Switch supports 1000Mbps mode with both single mode
and multi-mode SFP transceivers.
1. Before we connect Industrial PoE+ Switch to the other network device, we have
to make sure both sides of the SFP transceivers are with the same media type,
for example, 1000BASE-SX to 1000BASE-SX, 1000BASE-LX to 1000BASE-LX.
To connect to 1000BASE-LX or 1000BASE-BX SFP transceiver, please
use the single-mode ber cable with one side being the male duplex LC
connector type.
Connect the Fiber Cable
1. Insert the duplex LC connector into the SFP transceiver.
2. Connect the other end of the cable to a device with SFP transceiver installed.
3. Check the LNK/ACT LED of the SFP slot on the front of the Industrial PoE+
Switch. Ensure that the SFP transceiver is operating correctly.
17
Page 18
4. Check the Link mode of the SFP port if the link fails.
It is recommended to use PLANET SFPs on the Industrial PoE+
Switch. If you insert an SFP transceiver that is not supported, the
Note
Industrial PoE+ Switch will not recognize it.
3.4 Removing the Transceiver Module
1. Make sure there is no network activity by consulting or checking with the
network administrator. Or through the management interface of the switch/
converter (if available) to disable the port in advance.
2. Remove the Fiber Optic Cable gently.
3. Turn the lever of the MGB series module to a horizontal position.
4. Pull out the module gently through the lever.
MGBSeries
Transceiver
18
Note
Figure 2-4: Pull Out from the Transceiver
Never pull out the module without pulling the lever or the push
bolts on the module. Directly pulling out the module with force
could damage the module and the SFP module slot of the Industrial
PoE+ Switch.
Page 19
4. Troubleshooting
This chapter contains information to help you solve issues. If the Industrial PoE+
Switch is not functioning properly, make sure the Industrial PoE+ Switch was set
up according to instructions in this manual.
Q1: The per port LED is not lit
Solution:
Check the cable connection of the Industrial PoE+ Switch.
Q2 :Per port LED is lit, but the trafc is irregular
Solution:
Check whether the attached device is not set to dedicated full duplex. Some
devices use a physical or software switch to change duplex modes. Autonegotiation may not recognize this type of full-duplex setting.
Q3: Why the Industrial POE+ Switch doesn’t connect to the network
Solution:
Check each port LED on the Industrial PoE+ Switch. Try another port on the
Industrial PoE+ Switch. Make sure the cable is installed properly and the right
type. Turn off the power. After a while, turn on the power again.
Q4: Can I install MGB-SX or other non wide temperature SFP module into
SFP slot of Industrial PoE+ Switch?
Solution:
Yes, you can. However, the MGB-SX and the other non wide temperature SFP
module cannot operate under -40 to 75 degrees C.
19
Page 20
APPENDIX A: Networking Connection
A.1 PoE RJ45 Port Pin Assignments (End-span)
PIN NORJ45 POWER ASSIGNMENT
1 2 3 4 5 6 7 8
A.2 Switch’s RJ45 Pin Assignments
1000Mbps, 1000BASE-T
ContactMDIMDI-X
1BI_DA+BI_DB+
2BI_DA-BI_DB-
3BI_DB+BI_DA+
4BI_DC+BI_DD+
5BI_DC-BI_DD-
6BI_DB-BI_DA-
7BI_DD+BI_DC+
8BI_DD-BI_DC-
1Power +
2Power +
3Power -
6Power -
10/100Mbps, 10/100BASE-TX
RJ45 Connector Pin Assignment
Contact
1Tx + (transmit)Rx + (receive)
2Tx - (transmit)Rx - (receive)
3Rx + (receive) Tx + (transmit)
4, 5Not used
6Rx - (receive) Tx - (transmit)
7, 8Not used
Media Dependent Interface
MDI
Media Dependent Interface - Cross
20
MDI-X
Page 21
A.3 RJ45 Cable Pin Assignments
The standard RJ45 receptacle/connector
There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The
following shows the pin allocation and color of straight-through cable and crossover
cable connection:
Straight Cable
12345678
12345678
Crossover Cable
12345678
12345678
SIDE 1
SIDE 2
SIDE 1
SIDE 2
SIDE 1
1 = White/Orange
2 = Orange
3 = White/Green
4 = Blue
5 = White/Blue
6 = Green
7 = White/Brown
8 = Brown
SIDE 1SIDE 2
1 = White/Orange
2 = Orange
3 = White/Green
4 = Blue
5 = White/Blue
6 = Green
7 = White/Brown
8 = Brown
SIDE 2
1 = White/Orange
2 = Orange
3 = White/Green
4 = Blue
5 = White/Blue
6 = Green
7 = White/Brown
8 = Brown
1 = White/Green
2 = Green
3 = White/Orange
4 = Blue
5 = White/Blue
6 = Orange
7 = White/Brown
8 = Brown
Figure A-1: Straight-through and Crossover Cable
Please make sure your connected cables are with the same pin assignment and
color as the above picture before deploying the cables into your network.
21
Page 22
A.4 Fiber Optic Cable Connection Parameter
The wiring details are shown below:
1000X Fiber Optic Cables:
StandardFiber TypeCableSpecications
1000BASE-SX
(850nm)
1000BASE-LX
(1300nm)
Wiring Distances:
StandardFiber
1000BASE- SXMM
1000BASE- LX
Multi-mode50/125μmor62.5/125μm
Multi-mode50/125μmor62.5/125μm
Single-mode9/125μm
Diameter
(micron)
62.5
62.5
50
50
62.5
MM
SM9N/A5000*
50
50
Modal Bandwidth
(MHz * km)
100
200
400
500
5
4
5
Max. Distance
(meters)
220
275
500
550
550
22
Page 23
APPENDIX B: Approved PLANET SFP Transceivers
The following list of approved PLANET SFP transceivers is correct at the time of
publication: