1.5PRODUCT FEATURES .................................................................................................................................. 8
2.1.2 LED Indicators................................................................................................................................................... 12
2.1.3 DB9 and Terminal Block Pin Define .................................................................................................................. 12
2.1.4 Industrial Serial Converter Upper Panel............................................................................................................ 13
2.1.5 Wiring the Power Inputs .................................................................................................................................... 13
2.1.6 Wiring the Fault Alarm Contact ......................................................................................................................... 14
3.3.1 Web Management............................................................................................................................................. 21
3.3.2 Login the Media converter................................................................................................................................. 21
4. WEB MANAGEMENT ...................................................................................................23
4.1MAIN MENU .............................................................................................................................................. 23
4.2.1 System Information ........................................................................................................................................... 24
4.2.6 System Reboot.................................................................................................................................................. 28
4.4.4 Virtual COM Mode............................................................................................................................................. 38
4.4.5 Telnet Server Mode........................................................................................................................................... 44
4.4.6 Pair Connection– Local Mode ........................................................................................................................... 49
5.1INSTALLING THE VCOMUTILITY ................................................................................................................ 59
5.2SEARCH THE DEVICE................................................................................................................................. 61
Thank you for purchasing PLANET Industrial RS-232/RS-422/RS-485 over 10/100Base-TX/100Base-FX Media Converter –
ICS-210x series. Terms of “Industrial Serial Converter” means the products mentioned titled in the cover page of this
User’s manual.
1.1 Package Contents
Open the box of the Industrial Serial Converter and carefully unpack it. The box should contain the following items:
Check the contents of your package for following parts:
Industrial Serial Co nverter x1
CD-ROM User's Manual x1
Quick Installation Guide x1
Wall Mount Kit x 1
If any of these are missing or damaged, please contact your dealer immediately, if possible, retain the carton including the
original packing material, and use them against to repack the product in case there is a need to return it to us for repair.
1.2 How to Use This Manual
This Media Convert er Us er Man u al i s st r uc tu r ed as fo l lows:
Section 2, Installation
It explains the functions of ICS-210x and how to physically install the ICS-210x.
Section 3, Management
The chapter explains how to manage the converter by Web interface.
Section 4, Web Configuration
It contains information about the Smart function of ICS-210x.
Section 5, So ftware VCOM Utility
It explains the software VCOM how to use with the operation Virtual COM.
Appendix A
It contains cable and Smart Discovery utility information of ICS-210x.
1.3 Product Description
The Web-Smart ICS-210x series Media Converter / Device Server provide to converts Industrial Serial RS - 23 2 / RS-4 22
/ RS-485 communication interface over Fast Ethernet networking. There are RJ-45/SC/LC connectors and
single-mode/multi-mode media for your needs. Ethernet signal that allows two types of segments to connect easily,
efficiently and inexpensively. It’s time saving expense for user and SI, no need to replace the existing Serial equipment and
software system.
It extends the distance of deploying Serial equipments and hosts. The selectable fiber-Optic wires on the basis of distance
are flexibly provided. Therefore, this product will perfectly satisfy the diverse demands while providing reliable and efficient
network solutions based on the distance and budgets of installation.
-5-
User’s Manual of ICS-210x
The ICS-210x make connected Serial equipment becomes IP-based. That also makes them be able to connect to a TCP/IP
networking immediately. Each Web-Smart converter is able to manage through the Web Interface. The powerful
Web-Smart Media Converter supports Application mode, Serial operation mode connect alarm and IP address, etc.
Management function helps reduce the amount of valuable time that a network administrator spends detecting and locating
network problems, otherwise it requires visual inspection of cabling and equipment. Multiple connection options for large
networking environment are available as well.
The ICS-210x provides a high level of immunity to electromagnetic interference and heavy electrical surges typical of
environments found on plant floors or in curb side traffic control cabinets. The feature of operating temperature range of -10
to 60 Degree C coupled with hazardous location certification (Class 1 Division 2) allows the ICS-210x to be placed in almost
any location.
The ICS-210x equips with compact, IP-30 standard metal case that allows either DIN rail or wall mounting for efficient use
of cabinet space, the ICS-210x provides an integrated power supply source with wide range of voltages (12 to 48V DC or
24V AC) for worldwide operability with high availability applications requiring dual or backup power inputs.
1.4 Applications
Access Control System – Traditional Installation
Most of the enterprise and government use access control plate and Mifare or RFID to authorize the entrance identity. With
traditional deploy, access control machine use RS-232 or RS-485 serial interface and cables connect to login server. With
connection to ICS-210x Serial over Fast Ethernet Converter, the access control machine is able to be extend over longer
distances via fiber optical interface. The ICS-210x also can be linked to a xDSL router to get the internet access capability; the
access control can be set and monitored over the internet.
Figure 1-1 Industrial Serial Converter for Access Control System Application
-6-
User’s Manual of ICS-210x
Process Control
To monitor, configure and manage the Robot conveyer including other machines in a manufacturing, PLC (Programmable
Logical Control) is required. The PLC is used to drive above the manufacturing machines process. The ICS-210x can be set
to TCP Server mode and connect the PLC. The administrator can configure and set command settings through Fast Ethernet
intranet to control the PLC, the administrator and workstation. There is no need to be always sets by the side of the I/O
machine.
Figure 1-2 Industrial Serial Converter for Factory PLC Application
RTU Data Collect – UDP Mode
Connect with RTU (Remote Terminal Unit) to collect and monitor the data of waves, signal and power utilization. ICS-210x
can be used to set-up UDP mode and send data over Fast Ethernet to Local server or over internet to remote server
automatically.
Figure 1-3 Industrial Serial Converter for Factory RTU Application
-7-
User’s Manual of ICS-210x
Surveillance Motion Control – Pair Connection Mode
Using pair connection along with fiber optical patch cord, the ICS-210x extend RS-232/RS-485 interfaces distance from
surveillance and scanner to the control keyboard/joystick which is installed in the remote monitor center.
Figure 1-4 Industrial Serial Converter for Distance Extend Application
1.5 Product Features
Serial Interface
One RS-232 and the other RS-422/485 port to one 10/100Base-TX or 100Base-FX Media Converter
Cost effective solution for RS-232/RS-422/RS-485 to Ethernet application
Supports RS-232 with DB9 interface, 4-wire RS-422 or 2-wire RS-485 with 4-Pin terminal block operation
Asynchronous serial data rates up to 921600bps
Ethernet Interface
Complies with IEEE 802.3, IEEE 802.3u 10/100Base-TX, 100Base-FX standard
Supports auto MDI/MDI-X function on RJ-45 Port for ICS-2100
Supports 100Base-FX Multi-mode SC connector up to 2km for ICS-2102
Supports 100Base-FX Single-mode SC connector up to 15km for ICS-2102S15
Supports 100Base-FX Multi-mode / Single-mode LC connector, distance from 2km up to 120km for ICS-2105A
Smart Functions
Standard TCP/IP interface and versatile operation modes
Built-in IP-Base Web interface for remote management
Serial Operation mode selected via Web management
Pair Connection mode for connecting two serial devices over a network
PLANET Smart Discovery utility automatically finds client devices on the network
Firmware upgrade via HTTP protocol
-8-
User’s Manual of ICS-210x
Hardware
LED indicators for easy network diagnose
Reset Button at the front panel for reset to factory default
Industrial Case / Installation
IP-30 Metal case / Protection
DIN Rail and Wall Mount Design
12 to 48V DC / 24V AC redundant power with polarity reverse protect function and connective removable
terminal block for master and slave power
Supports EFT protection 6000 VDC for power line
Supports 6000 VDC Ethernet ESD protection
-10 to 60 Degree C operation temperature
1.6 Product Specification
Model ICS-2100 ICS-2102 ICS-2102S15 ICS-2105A
Serial Port
Interface
Connector
Baud Rate (Data Rate) 300bps to 921600bps
Data Bits 5,6,7,8
Parity Type 1, 1.5/2
Stop Bit Odd, Even, None, Space, Mark
Flow Control H/W, None
Signals
Fast Ethernet Port
Standard 10/100Base-TX 100Base-FX
Connector RJ-45 SC LC
Mode - Multi-Mode Single-Mode
Distance 100m 2km 15km
Optical Wavelength - 1300nm 1310nm (Vary on SFP module)
Cable Twisted-pair
Hardware
LED Indicators
RS-232 x 1
RS-422 / RS-485 x 1
DB9 for RS-232
Terminal block for RS-422 / RS-485
RS-232: DCD, RxD, TxD, GND, RI
RS-422: Tx+, Tx-, Rx+, Rx-
RS-485: Data A (+), Data B (-)
50 or 62.5/125μm
multi-mode fiber
cable
System: Power 1, Power 2, Fault
TP or Fiber Port: Link / Active
9/125μm
single-mode cable
Multi-Mode
Single-Mode
2km up to 120km
(Vary on SFP module)
50 or 62.5/125μm
multi-mode fiber cable
9/125μm single-mode cable
-9-
User’s Manual of ICS-210x
Serial Port: Serial port mode, RS-232, RS-422 or RS-485
Web Management
Management
Operation Mode
Dimension(W x D x H) 135 x 97 x 32 mm
Weight 425g 431g 428g
Power Supply 12~48V DC / 24V AC, Redundant power with polarity reverse protection function
Power Consumption 10.1 Watts / 34.44 BTU (max)
Installation DIN Rail kit and Wall Mount ear
Alarm Provides one relay output for power fail, Alarm Relay current carry ability: 1A @ DC 24V
Mechanical Metal
Environment
Emissions FCC Class A, CE Certification Class A
Standards
Regulatory Approval RoHS
Stability Testing
Note. Reset Button at the front panel for reset to factory default
PLANET Smart Discovery Utility
VCOM
TCP Server
TCP Client
UDP Client
Virtual COM
Telnet Server
Pair Connection – Remote (Slave)
Pair Connection – Local (Master)
Operating Temperature: -10~60 Degree C
Storage Temperature: -20~75 Degree C
Operating Humidity: 10%~90% RH
Storage Humidity: 5%~90% RH
IEEE 802.3 10Base-T,
IEEE 802.3u 100Base-TX / 100Base-FX
EIA/TIA RS-232/422/485
IEC60068-2-32(Free fall),
IEC60068-2-27(Shock),
IEC60068-2-6(Vibration)
-10-
User’s Manual of ICS-210x
2. HARDWARE INSTALLATION
This section describes the hardware features and installation of the ICS-210x’s components on the desktop or shelf. For
easier management and control of the ICS-210x, familiarize yourself with its display indicators, and ports. Front panel
illustrations in this chapter display the unit LED indicators. Before connecting any network device to the Industrial Serial
Converter, please read this chapter completely.
2.1 Hardware Description
2.1.1 Product Layout
Figure 2-1 to Figure 2-3 show front panel of ICS-210x.
ICS-2100 ICS-2102 / ICS-2102S15 ICS-2105A
Figure 2-1
ICS-2100 Front Panel
ICS-2102/2102S15 Front Panel
Figure 2-2
-11-
Figure 2-3
ICS-2105A Front Panel
2.1.2 LED Indicators
LED Color Function
P1 Green Lights Indicate the power 1 has power.
P2 GreenLights Indicate the power 2 has power.
FAULT Green Lights Indicate the either power 1 or power 2 has no power.
TP or Fiber Green
Serial Green
Lights
Blinks To indicate the Fast Ethernet Port is receiving or sending data.
Lights
Lights
and off
Lights
and off
faster
User’s Manual of ICS-210x
To indicate that the Fast Ethernet Port is successfully connecting to the
network at 10Mbps or 100Mbps.
To indicate that the RS-232 Port is connected successfully
To indicate the RS-422 Port is receiving or sending data
To indicate the RS-485 Port is receiving or sending data
2.1.3 DB9 and Terminal Block Pin Define
DB9 Pin Define for RS-232
Terminal Block Define for RS-422/485
Terminal Block Pin4-wire for RS-4222-wi re for RS -4 85
DB9-PIN RS-232
1 DCD
2 RXD
3 TXD
4
5 GND
6
7
8
9 RI
RX+ RX+ Data A(+)
RX- RX- Data B(-)
TX+ TX+
TX- TX-
-12-
User’s Manual of ICS-210x
2.1.4 Industrial Serial Converter Upper Panel
The upper panel of the Industrial Serial Converter consist one terminal block connector within two DC power inputs. Figure
2-4 shows the upper panel of the industrial serial converter.
Figure 2-4 Industrial Serial Converter upper Panel.
2.1.5 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of Industrial Serial Converter is used for two DC redundant powers
input. Please follow the steps below to insert the power wire.
1. Insert positive / negative DC power wires into the contacts 1 and 2 for POWER 1, or 5 and 6 for POWER 2. Figure 2-5
shows PWR1 and PWR2 of the industrial serial converter.
Figure 2-5 PWR1 & PWR2 of Industrial Serial Converter.
-13-
User’s Manual of ICS-210x
2. Tighten the wire-clamp screws for preventing the wires from loosing. Figure 2-6 shows PWR1 and PWR2 pin of the terminal
block.
1 2 3 4 5 6
Power 1 Fault Power 2
- + - +
Figure 2-6 PWR1 & PWR2 pin of terminal block.
The wire gauge for the terminal block should be in the range between 12 ~ 24 AWG.
2.1.6 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block connector as the picture shows below. Inserting the wires, the
Industrial Serial Converter will detect the fault status of the power failure, or port link failure (available for managed model) and
then forms an open circuit. The following illustration shows an application example for wiring the fault alarm contacts. Figure
2-7 shows fault pin of the terminal block & figure 2-8 shows fault alarm contact.
1 2 3 4 5 6
Insert the wires into the fault alarm contacts
Figure 2-7 Fault pin of terminal block.
-14-
User’s Manual of ICS-210x
1. The wire gauge for the terminal block should be in the range between 12 ~ 24 AWG.
2. Alarm relay circuit accepts up to 30V, max. 3A currents.
Figure 2-8 Fault alarm contact.
2.2 Mounting Installation
This section describes how to install the Industrial Equipment and make connections to it. Please read the following topics and
perform the procedures in the order being presented.
In the installation steps below, this Manual use IGS-801(PLANET 8 Port Industrial Gigabit
Switch) as the example. However, the steps for PLANET Industrial Switch & Industrial Media
/ Serial Converter are similar.
2.2.1 DIN-Rail Mounting
The DIN-Rail is screwed on the Industrial Equipment when out of factory. When need to replace the wall mount application
with DIN-Rail application on Industrial Equipment, please refer to following figures to screw the DIN-Rail on the Industrial
Serial Converter. To hang the Industrial Switch, follow the below steps:
Step 1: Lightly press the button of DIN-Rail into the track. Figure 2-9 shows how to install Industrial Equipment in DIN-Rail
mount.
Figure 2-9 Install Industrial Equipment in DIN-Rail mount.
-15-
User’s Manual of ICS-210x
Step 2: Check the DIN-Rail is tightly on the track. Figure 2-10 shows that install Industrial Equipment finish in DIN-Rail mount.
Figure 2-10 Industrial Equipment installed in DIN-Rail mount.
2.2.2 Remove DIN-Rail Mounting
Step 1: Please refer to following procedures to remove the Industrial Equipment from the track. Figure 2-11 shows how to
remove Industrial Equipment in DIN-Rail mount.
Figure 2-11 Remove Industrial Equipment in DIN-Rail mount.
Step 2: Lightly press the button of DIN-Rail for remove it from the track.
-16-
User’s Manual of ICS-210x
2.2.3 Wall Mount Plate Mounting
To install the Industrial Equipment on the wall, please follows the instructions described below.
Step 1: Remove the DIN-Rail from the Industrial Equipment; loose the screws to remove the DIN-Rail.
Step 2: Place the wall mount plate on the rear panel of the Industrial Equipment. Figure 2-12 shows how to attach brackets to
one side of the Industrial Equipment.
Figure 2-12 Attach brackets to the Industrial Equipment.
Step 3: Use the screws to screw the wall mount plate on the Industrial Equipment.
Step 4: Use the hook holes at the corners of the wall mount plate to hang the Industrial Equipment on the wall.
Step 5: To remove the wall mount plate, reverse steps above.
2.2.4 Stand-alone Installation
To install an ICS-210x stand-alone, on a desktop or shelf, simply complete the following steps:
Step 1: Turn off the power of the device/station in a network to which the ICS-210x will be attached.
Step 2: Ensure that there is no activity in the network.
Step 3: Attach RJ-45 / SC / LC Fiber cable from the ICS-210x to the network.
Step 4: Attach RS-232/RS-485 cable from the ICS-210x to the want to connect devices.
Step 5: Connect the DC power to the ICS-210x and verify that the Power LED lights up.
Step 6: Turn on the power of the device/station; the PWR LED (Green) should light when all cables are attached.
-17-
User’s Manual of ICS-210x
Figure 2-13 ICS-2100 stand alone installation
Figure 2-14 ICS-2102 / ICS-2102S15 stand alone installation
-18-
User’s Manual of ICS-210x
Figure 2-15 ICS-2105A stand alone installation
Please refers to APPENDIX-A for detailed wiring information of the ICS-210x.
To prevent from optic acceptor malfunction, check the both wires / transmitter before power on the
converter.
-19-
User’s Manual of ICS-210x
3. INDUSTRIAL MEDIA CONVERTER
MANAGEMENT
This chapter describes how to manage the ICS-210x. Topics include:
- Overview
- Management methods
- Assigning an IP address to the ICS-210x
- Logging on to the ICS-210x
3.1 Overview
This chapter gives an overview of converter management. The ICS-210x provides a simply WEB browser interface. Using
this interface, you can perform various converter configuration and management activities, including:
System
Network Configuration
Operation Mode
Serial Port Configu ration
SMTP
Please refer to the following Chapter 4 for more details.
3.2 Requirements
■ Network cables.
For ICS-2100: Use standard network (UTP) cables with RJ-45 connectors.
For ICS-2102 / ICS-2102S15: Use Multi-mode or Single-mode fiber patch cord with SC connectors.
For ICS-2105A: Use Multi-mode or Single-mode fiber patch cord with LC connectors.
■ Subscriber PC installed with Ethernet NIC (Network Card)
■ Workstations of subscribers running Windows 98/ME, NT4.0, 2000/2003/XP/7, MAC OS X or later, Linux, UNIX or
other platform compatible with TCP/IP protocols.
■ Above PC installed with WEB Browser, such as Microsoft Internet Explore or Mozilla Firefox
It is recommended to use Internet Explore 7.0 or above to access Industrial Serial
Media Converter.
-20-
User’s Manual of ICS-210x
3.3 Management Methods
Theway to manage the ICS-210x:
- Web Management via a network or dial-up connection
3.3.1 Web Management
The PLANET Industrial Web-Smart Serial Converter provides a built-in browser interface. You can manage the ICS-210x
remotely by having a remote host with web browser, such as Microsoft Internet Explorer, Netscape Navigator or Mozilla
Firefox.
Using this management method:
The ICS-210x must have an Internet Protocol (IP) address accessible for the remote host.
Figure 3-1 Web Management over Ethernet
3.3.2 Login the Media converter
Before you start configure the ICS-210x, please note the ICS-210x is configured through an Ethernet connection, make sure
the manager PC must be set on same the IP subnet address.
For example, the default IP address of the ICS-210x is 192.168.0.100, then the manager PC should be set at 192.168.0.x
(where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.
1. Use Internet Explorer 7.0 or above Web browser. Enter IP address http://192.168.0.100 (the factory-default IP
address) to access the Web interface.
2. When the following login screen appears, please enter the default username and password (default user name and
password is "admin"). Press Login to enter the main screen of ICS-210x. The login screen in Figure 3-2 appears.
Default IP Address: 192.168.0.100
Default Account: admin
Default Password: admin
-21-