1.5PRODUCT FEATURES .................................................................................................................................. 4
2.1.2 LED Indicators................................................................................................................................................... 10
3.3.1 Web Management............................................................................................................................................. 15
3.3.2 Login the Media converter................................................................................................................................. 15
4. WEB CONFIGURATION...............................................................................................17
4.1MAIN MENU .............................................................................................................................................. 17
4.2.1 System Information ........................................................................................................................................... 18
4.2.5 System Reboot.................................................................................................................................................. 22
4.4.4 Virtual COM Mode............................................................................................................................................. 32
4.4.5 Telnet Server Mode........................................................................................................................................... 40
4.4.6 Pair Connection– Local Mode ...........................................................................................................................45
5.1INSTALLING THE VCOMUTILITY ................................................................................................................ 55
5.2SEARCH THE DEVICE................................................................................................................................. 58
A.6POWER INFORMATION ............................................................................................................................... 65
-5-
User’s Manual of ICS-10x
1. INTRODUCTION
Thank you for purchasing PLANET Serial over Fast Ethernet Media Converter – ICS-10x series. Terms of “Serial Media
Converter” means the products mentioned titled in the cover page of this User’s manual
1.1 Package Contents
Open the box of the Serial Media Converter and carefully unpack it. The box should contain the following items:
Check the contents of your package for following parts:
Serial Media Converter x1
CD-ROM User's Manual x1
Quick Installation Guide x1
External 5VDC / 2.5A Power Adapter x 1
If any of these are missing or damaged, please contact your dealer immediately, if possible, retain the carton including the
original packing material, and use them against to repack the product in case there is a need to return it to us for repair.
1.2 How to Use This Manual
This Media Convert e r Us er Man u al i s st r uc tu r ed as fo l lows:
Section 2, Installation
It explains the functions of ICS-10x and how to physically install the ICS-10x.
Section 3, Management
The chapter explains how to manage the converter by Web interface.
Section 4, Web Configuration
It contains information about the Smart function of ICS-10x.
Section 5, So ftware VCOM Utility
It explains the software VCOM how to use with the operation Virtual COM.
Appendix A
It contains cable and Smart Discovery utility information of ICS-10x.
-1-
User’s Manual of ICS-10x
1.3 Product Description
The Web-Smart ICS-10x series Media Converter / Device Server provide to converts Serial RS-232 / RS-422 / RS-485
communication interface over Fast Ethernet networking. There are RJ-45/SC connectors and
single-mode/multi-mode media for your needs. Ethernet signal that allows two types of segments to connect easily,
efficiently and inexpensively. This converter can be used as a stand-alone unit or as a slide-in module to the PLANET
Media Converter Chassis (MC-700, MC-1500 and MC-1500R). It’s time saving expense for user and SI, no need to
replace the existing Serial equipment and software system.
It extends the distance of deploying Serial equipments and hosts. The selectable fiber-Optic wires on the basis of
distance are flexibly provided. Therefore, this product will perfectly satisfy the diverse demands while providing reliable
and efficient network solutions based on the distance and budgets of installation.
The ICS-10x make connected Serial equipment becomes IP-based. That also makes them be able to connect to a
TCP/IP networking immediately. Each Web-Smart converter is able to manage through the Web Interface. The powerful
Web-Smart Media Converter supports Application mode, Serial operation mode connect alarm and IP address, etc.
Management function helps reduce the amount of valuable time that a network administrator spends detecting and
locating network problems, otherwise it requires visual inspection of cabling and equipment. Multiple connection options
for large networking environment are available as well.
1.4 Applications
Access Control System – Traditional Installation
Most of the enterprise and government use access control plate and Mifare or RFID to authorize the entrance identity.
With traditional deploy, access control machine use RS-232 or RS-485 serial interface and cables connect to login server.
With connection to ICS-10x Serial over Fast Ethernet Converter, the access control machine is able to be extend over
longer distances via fiber optical interface. The distance can be up to 15km in a local range. Or the ICS-10x can be linked
to a xDSL router to get the internet access capability; the access control can be set and monitored over the internet.
Figure 1-1 Serial Converter for Access Control System Application
-2-
User’s Manual of ICS-10x
Process Control
To monitor, configure and manage the Robot conveyer including other machines in a manufacturing, PLC (Programmable
Logical Control) is required. The PLC is used to drive above the manufacturing machines process. The ICS-10x can be set
to TCP Server mode and connect the PLC. The administrator can configure and set command settings through Fast
Ethernet intranet to control the PLC, the administrator and workstation. There is no need to be always sets by the side of
the I/O machine.
Figure 1-2 Serial Converter for Factory PLC Application
RTU Data Collect – UDP Mode
Connect with RTU (Remote Terminal Unit) to collect and monitor the data of waves, signal and power utilization. ICS-10x
can be used to set-up UDP mode and send data over Fast Ethernet to Local server or over internet to remote server
automatically.
Figure 1-3 Serial Converter for Factory RTU Application
-3-
User’s Manual of ICS-10x
Surveillance Motion Control – Pair Connection Mode
Using pair connection along with fiber optical patch cord, the ICS-10x extend RS-232/RS-485 interfaces distance from
surveillance and scanner to the control keyboard/joystick which is installed in the remote monitor center.
Figure 1-4 Serial Converter for Distance Extend Application
1.5 Product Features
Serial Interface
One RS-232/422/485 port to one 10/100Base-TX or 100Base-FX Media Converter
Cost effective solution for RS-232 to Ethernet application
Supports RS-232, 4-wire RS-422 or 2/4-wire RS485 operation
Asynchronous serial data rates up to 230400b/s
Ethernet Interface
Complies with IEEE 802.3, IEEE 802.3u 10/100Base-TX, 100Base-FX standard
Supports auto MDI/MDI-X function on RJ-45 Port
Choice of fiber-connector from ST / SC, multi-mode / single-mode fiber
Smart Functions
Standard TCP/IP interface and versatile operation modes
PWR Green Lights to ind the is poweicate that Converterred on.
To isfully connectin
indicate that the Fast Ethernet Port s succesg to the
network at 10Mbps or 100Mbps
To indi the Fast Port is receiving or sending data cateEthernet
To indte that the Port is connecteccessfully ica UARTd su
To indte the UArt is receiving oring data icaRT Po send
TP or Fiber Green
Serial Green
Lights
Blinks
Lights
Blinks
User’s Manual of ICS-10x
2.1.3 DB9 Pin Define
DB9 Pin Define for RS-232 / RS-422 / RS-485
DB9-PIN RS-232
1 DCD
2 RXD
3 TXD
4 DTR RX- Data B(-)
5 GND
6 DSR TX-
7 RTS RX+ Data A(+)
8 CTS TX+
9 RI
RS-422/485
4-wire
RS-485
2-wire
-10-
User’s Manual of ICS-10x
2.1.4 ICS-10X Rear Pan
The rear panel of the converter indicates one DC jack, which accepts input power with 5V DC 2.5A.
■ ICS-10x ser
ies
el
Figure 2-5 Rear Panel of ICS-10x
1. The device is a power-required device, it means, it will not work till it is powered. If your networks
should active all the time, please consider using UPS (Uninterrupted Power Supply) for your
Power
Notice:
device. It will prevent you from
2. In some area, installing a s
Converter from being damaged by unregulated surge or current to the converter or the power
adapter.
network data loss or network downtime.
urge suppression device may also help to protect your Media
To press and release the RESET button. The ICS-10x will back to the factory default mode. Be sure that
you backup the current configuration of ICS-10x; else the entire configuration will be erased when
pressing the “RESET” button.
• Press and release the RESET
• Press the RESET button more than 10 seconds, the device will back
mode; the entire configuration will be erased.
button shortly, the device will be rebooted.
to the factory default
2.2 Install the Converter
This section describes how to install your ICS-10x Web Smart Media Converter and make connections to the converter.
Please read the following topics and perform the procedures in the order being presented. The hard
PLANET ICS-10x Web Smart Media Converter do not need software configuration. To install your ICS
shelf, simply complete the following steps.
2.2.1 Stand-alone Installation
ware installation of
-10x on a desktop or
To install an ICS-10x stand-alone, on a desktop or shelf, simply complete the following steps:
Step 1: Turn off the power of the device/station in a network to which the ICS-10x will be attached.
Step 2: Ensure that there is no activity in the network.
Step 3: Attach RJ-45 / SC / ST Fiber cable from the ICS-10x to the network.
Step 4: Attach RS-232/RS-485 cable from the ICS-10x to the want to connect devices.
Step 5: Connect the 5VDC power adapter to the ICS-10x and verify that the Power LED lights up.
-11-
User’s Manual of ICS-10x
Step 6: Turn on the power of the device/station; the PWR LED (Green) should light when all cables are attached.
Figure 2-6 ICS-100 stand alone installation
Figure 2-7 ICS-101 / ICS-102 / ICS-102S15 stand alone installation
Please refers to APPENDIX-A for detailed wiring information of the ICS-10x.
To prevent from optic acceptor malfunction, check the both wires / transmitter before power on the
converter.
-12-
User’s Manual of ICS-10x
2.2.2 Chassis Installation and Rack Mounting
To install the Media Converter in a 10-inch or 19-inch with standard rack, follow the instructions described below.
Step 1: Place your ICS-10x on a hard flat surface, with the front panel positioned towards your front side.
Step 2: Carefully slide in the module until it is fully and firmly fitted into the slot of the chassis.
Figure 2-8 Insert a Media Converter into an available slot
Step 3: of the Chassis with supplied screws attached to the package. Attach a rack-mount bracket to each side
Step 4: After the brac
shown in Figu
Step 5: Precede with the steps 4 and steps 5 of session 2.2.1 Stand-alone Inst al l atio n to connect the network cabling
and supply power to your converter.
kets are attached to the chassis, use suitable screws to securely attach the brackets to the rack, as
re 2-9.
You must use the screws supplied with the mounting brackets. Damage caused to the parts by using
incorrect screws would invalidate your warranty.
Figure 2-9 Mounting the Chassis in a Rack
-13-
User’s Manual of ICS-10x
3. MANAGEMENT
This chapter describes how to manage the ICS-10x. Topics include:
- Overview
- Management methods
- Assigning an IP address to the ICS-10x
- Logging on to the ICS-10x
3.1 Overview
This chapter gives an overview of converter management. The ICS-10x provides a simply WEB browser interface. Using
this interface, you can perform various converter configuration and management activities, including:
System
Network Configuration
Operation Mode
Serial Port Configuration
SMTP
Please refer to the following Chapter 4 for more details.
3.2 Requirements
■ Network cables.
For ICS-100: Use standard network (UTP) cables with RJ-45 connectors.
For ICS-101: Use Multi-mode fiber patch cord with ST connectors.
For ICS-102 / ICS-102S15: Use Multi-mode or Single-mode fiber patch cord with SC connectors.
■ Subscriber PC installed with Ethernet NIC (Network Card)
■ Workstations of subscribers running Windows 98/ME, NT4.0, 2000/2003/XP, MAC OS X or later, Linux, UNIX or
other platform compatible with TCP/IP protocols.
■ Above PC installed with WEB Browser, such as Microsoft Internet Explore or Mozilla Firefox
It is recommended to use Internet Explore 6.0 or above to access Serial Media
Converter.
-14-
User’s Manual of ICS-10x
3.3 Management Methods
Theway to manage the ICS-10x:
- Web Management via a network or dial-up connection
3.3.1 Web Management
The PLANET Web-Smart Media Converter provides a built-in browser interface. You can manage the ICS-10x remotely
by having a remote host with web browser, such as Microsoft Internet Explorer, Netscape Navigator or Mozilla Firefox.
Using this management method:
The ICS-10x must have an Internet Protocol (IP) address accessible for the remote host.
Figure 3-1 Web Management over Ethernet
3.3.2 Login the Media converter
Before you start configure the ICS-10x, please note the ICS-10x is configured through an Ethernet connection, make sure
the manager PC must be set on same the IP subnet address.
For example, the default IP address of the ICS-10x is 192.168.0.100, then the manager PC should be set at 192.168.0.x
(where x is a number between 1 and 254 except 100), and the default subnet mask is 255.255.255.0.
1. Use Internet Explorer 6.0 or above Web browser. Enter IP address http://192.168.0.100 (the factory-default IP
address) to access the Web interface.
2. When the following login screen appears, please enter the default username and password (default user name and
password is "admin"). Press Login to enter the main screen of ICS-10x. The login screen in Figure 3-2 appears.
Default IP Address: 192.168.0.100
Default Account: admin
Default Password: admin
-15-
User’s Manual of ICS-10x
Figure 3-2 Login screen
1. For security reason, please change and memorize the new password after this first setup.
2. Only accept command in lowercase letter under web interface.
-16-
User’s Manual of ICS-10x
4. WEB CONFIGURATION
The ICS-10X Web Smart Media Converter provide Web interface for Converter smart function configuration and make the
Converter operate more effectively - They can be configured through the Web Browser. A network administrator can
manage and monitor the ICS-10x from the local LAN. This section indicates how to configure the Media Converter to
enable its smart function.
4.1 Main Menu
After a successful login, the main screen appears, the main screen displays the converter Welcome page. The screen in
Figure 4-1 appears.
Figure 4-1 Web Main screen
As listed at the left of the main screen, the configurable smart functions are shown as below:
• System
• Network Configuration
• Operation Mode
• Serial Port Configu ration
• SMTP
Check the hardware, software version and System MAC address and IP address of
the converter. And the password changed firmware upgrade / Factory default /
system reboot.
Setup the IP address of the converter.
Setup the serial port mode: “TCP server”, “TCP client”, “UDP client”, “Virtual COM”,
“Telnet Server”, “Pair Connection – Remote (Master)” and “Pair Connection –
Remote (Slave)”.
Setup the serial port value.
Setup the SMTP mail parameters for further operation of events.
-17-
Loading...
+ 49 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.