4.2 Home Page ......................................................................................................................................... 21
4.3 System Related Settings.................................................................................................................... 22
4.3.1
Host Name and System Time Setting .............................................................................. 22
4.4 Video and Audio Streaming Settings .................................................................................................. 44
4.4.1
Video Resolution and Rotate Type .................................................................................. 44
4.4.2
Video Compression .........................................................................................................46
4.4.3
Video OCX Protocol ....................................................................................................... 46
4.4.4
Video Frame Skip............................................................................................................ 47
4.4.5
Audio Mode and Bit Rate Settings.................................................................................. 48
4.5 Camera Settings ................................................................................................................................... 49
PLANET announces new H.264 Full-HD IP camera, ICA-HM126, ICA-HM126R, ICA-HM131 and
ICA-HM131R to feedback the requirements from worldwide market. The IP Camera support Full HD recording
for high quality images. Integrated with the next generation video compression technology – H.264, the IP
Camera can compress the video size to smaller one for users to transfer the Full-HD images on Internet easily
and fastly.
The IP Camera features Multi-Profile to provide video stream simultaneously. They can deliver clear image
with dual H.264/M-JPEG stream video up to 1080p (1920 x 1080 pixels). The IP Cameras use progressive
scan to perform full resolution images of moving objects without distortion, in 30 frames per second, which is
perfect for critical areas surveillance such as at entrances or exits of the building where are needed to be
monitored in greater details. The IP Cameras is compatible with IEEE 802.3af PoE (Power over Ethernet) for
easy installation without concerning the outlet / socket locations. Network and analog video output interfaces
are equipped for flexible viewing and recording implementations.
PLANET ICA-HM126/126R supports 2-Way audio that can directly make audio communication between local
and remote sites by using the built-in microphone and adding an external speaker. Users can build a more
advanced security system by connecting external sensors or alarm to DI / DO ports of the ICA-HM126/126R.
The IP Camera can be managed by PLANET Cam Viewer Plus, the professional central management
software for multi-camera video surveillance application, to provide monitoring, recording and event
management functions. The Cam Viewer Plus enables you to setup a comprehensive and effective
surveillance system quickly and easily. With the IP Camera managed by the Cam Viewer Plus, it provides an
enhanced professional security environment to protect your property and life.
Product Features
• 1/2.7” progressive CMOS
• Dual video stream : H.264 and M-JPEG video compression simultaneously
• Supports 1080p Full-HD resolution (1920 x 1080 pixels)
• 30 fps at 1080p Video Resolution (ICA-HM126R / ICA-HM131R)
• Compliant with IEEE 802.3af PoE interface
• 3GPP for 3G mobile remote applications
• 2-Way audio function with built-in microphone and external speaker (ICA-HM126 Series)
- 6 -
Page 7
• Supports Micro SD card storage
• External I/O trigger for various surveillance applications (ICA-HM126 Series)
• Provides 10 Motion Detection areas can monitor any suspicious movement in specific areas
• Easy configuration and management via Windows-Based utility or web interface
• DDNS, PPPoE and FTP uploading supports more alternatives in surveillance network
• Motion Detection feature can monitor any suspicious movement in specific area
• Cam Viewer Plus - Central management software supported
Package Content
The contents of your product should contain the following items:
IP Camera
Lens (ICA-HM126 Series)
Quick installation guide
User’s manual CD
Accessories Kit
Power Adapter (ICA-HM126 Series)
Physical Details
Top View – ICA-HM126 Series
Item Description
1 Microphone
The IP Camera has built-in an internal microphone. This microphone is
hidden in the pinhole located on the front panel.
1. Microphone
Front View of ICA-HM126/126R
- 7 -
Page 8
Rear View – ICA-HM126 Series
1. Video Out
Connector
2. DI / DO
Connector
3. Reset
Button
4. Power
Connector
1 Video Out Connector
2 DI / DO Connector
Item Description
5. Auto Iris
Connector
6. Line In /
Line Out
7. Mirco SD
Card slot
Side View of ICA-HM126/126R
The internet camera also provides composite video output. User can
use BNC video cable to connect the internet camera with a TV monitor
or VCR.
Connect connects to external sensor in and alarm out devices.
Pin Function
1 Output +
2 Output 3 Input +
4 Input -
8. RJ-45
LAN Socket
3 Reset Button
4 Power Connector
5 Auto Iris Connector
6 Line In / Line Out
7 Micro SD Card slot
8 RJ-45 LAN Socket
- 8 -
Restore to default setting, press the button with a proper tool.
The input power is 12V DC.
Note: ONLY use package power adapter supplied with the product.
Otherwise, the product may be damaged.
The connector can drive CCTV auto iris lenses.
For video and snapshots storage
The LAN socket is a RJ-45 connector for connections to
10/100Base-TX Fast Ethernet cabling. The LAN socket is compliant
with IEEE802.3af standard PoE interface, and IP Camera is necessary
supplied power through PoE Switch/Hub device.
Page 9
Top View – ICA-HM131 Series
4. Tilt Fixed
Screw
5. Microphone
1 Lens
Top View of ICA-HM131/131R
Item Description
Rotate the lens right/left to adjust focus
1. Lens
2. Reset Button
3. Focus Fixed
Screw
2 Reset Button
3 Focus Fixed Screw
4 Tilt Fixed Screw
5 Microphone
Restore to default setting, press the button with a proper tool
Loosen the screw to adjust the lens
Loosen the screw to adjust tilt angle
The IP Camera has built-in an internal microphone. This microphone is
hidden in the internal case.
- 9 -
Page 10
Side View – ICA-HM131 Series
1. Micro-SD
2. RJ-45 LAN
Socket
Card slot
1 Micro-SD Card slot
2 RJ-45 LAN Socket
Item Description
Side View of ICA-HM131/131R
User can insert a micro SD card into this slot for event recording.
The LAN socket is a RJ-45 connector for connections to
10/100Base-TX Fast Ethernet cabling. The LAN socket is compliant
with IEEE802.3af standard PoE interface, and IP Camera is necessary
supplied power through PoE Switch/Hub device.
- 10 -
Page 11
Chapter 2
2
Preparations for IP Camera Setup
Physical Installation Requirement
The notices and introduction on system installation will be described particularly in this chapter. Please follow
the description to operate the unit.
In order to prevent the unit from data loss and system damage that caused by a sudden power fluctuation, use
of an Uninterruptible Power Supply (UPS) is highly recommended.
2.1 System Requirements
To perform the IP Camera via web browser, please ensure your PC is in good network connection, and meet
system requirements as described below for appropriate setup and well view quality.
Items System Requirement
Personal Computer
R
○
1. Intel
2. 2 GB RAM or more
Pentium
R
○
M, 2.16 GHz or Intel
R
○
CoreTM2 Duo, 2.0 GHz
Operating System
Web Browser
Network Card
Viewer
Windows Vista or Windows XP
Microsoft Internet Explorer 6.0 or later
10Base-T (10 Mbps) or 100Base-TX (100 Mbps) operation
ActiveX control plug-in for Microsoft IE
2.2 Installation
Please follow the instructions below to complete IP Camera installation.
2.2.1 ICA-HM126 Series Installation
Step 1. Lens Mounting: C/CS Mount Lens Model
If use CS-Mount lens, after removing the camera’s plastic cover, users need to mount the C/CS mount
adapter to the camera. Then attach the lens onto the C/CS mount adapter, as the illustrations shown below.
C/CS Mount Adapter Completion
- 11 -
Page 12
NOTE: The C/CS Mount Adapter isn’t attached in product package.
Step 2. Plug an Ethernet cable into the Camera
Connect an Ethernet cable to the LAN socket located on the IP Camera’s bottom and attach it to the
network.
Step 3. Connect the external power supply to Camera
Connect the attached power adapter to the DC power jack of the IP Camera. Note: Use the power
adapter, 12VDC, included in the package and connect it to wall outlet for AC power.
Once you have installed the IP Camera well and powered it on, the network accessing type LED will turn
on. It means the system is booting up successfully. Check the status of the link indicator and activity indicator
LEDs; if the LEDs are unlit, please check the connections.
Green Link Light indicates good network connection.
Orange Activity Light flashes for network activity indication.
Note
1. Only use the power adapter supplied with Internet Camera Otherwise,
the product may be damaged.
2. The power adapter is unnecessary when Internet Camera is
connected to an IEEE802.3af PoE switch. Otherwise, the product may
be damaged when Internet Camera is connected to a PoE switch and
power adapter simultaneously.
- 12 -
Page 13
2.2.2 ICA-HM131 Series Installation
Connect the one end of the Ethernet cable to the network port on the camera, and the other end to Power
Sourcing Equipment (PSE) like 802.3af POE Hub/ Injector or 802.3af POE Switch.
Check the status of the link indicator and activity indicator LEDs; if the LEDs are unlit, please check the
connections.
Green Link Light indicates good network connection.
Orange Activity Light flashes for network activity indication.
3. The RJ-45 interface only accept IEEE802.3af PSE (Power Source
Equipmetns) Any non-standard or passive POE is not allowed to
power the system and will damage the IP Camera permanently.
4. You can also consult your local dealer for 802.3af POE PSE devices
such as single port injector for single point installation. Or, for mass
Note
installation, a Injector Hub for the network that already existed with
Ethernet Switches or POE Switch all can be deployed
2.3 Alarm Application (ICA-HM126 Series)
The camera equips one relayalarm input and one relay output for alarm application. Refer to alarm pin
definition below to connect alarm devices to the IP Camera if needed.
1. Output+
2. Output-
3. Input+
4. Input-
- 13 -
Page 14
Chapter 3
3
Accessing Camera
For initial access to the IP Camera, users can search the camera through the installer program:
DeviceSearch.exe, which can be found in “DeviceSearch” folder in the supplied CD.
3.1 Device Search Software Setup
Step 1: Double click on the program Planet Device Search.exe (see the icon below); its window will
appear as shown below. Then click the “Device Search” button.
Step 2: The security alert window will pop up. Click “Run” to continue.
- 14 -
Page 15
3.2 Device Search
Step 3: Click “Device Search” again, and all the finding IP devices will be listed in the page, as shown
in the figure below. The IP Camera’s default IP address is: 192.168.0.20.
Step 4: Double click or right click and select “Browse” to access the camera directly via web browser.
Step 5: Then the prompt window of request for entering default username and password (as shown
below) will appear for logging in to the IP Camera.
- 15 -
Page 16
The default login ID and password for the Administrator are:
Login ID Password
admin
null (without password)
NOTE: ID and password are case sensitive.
NOTE: It is strongly advised that administrator’s password be altered for the security
concerns. Refer to section 4.3.2 Security
Additionally, users can change the IP Camera’s network property, either DHCP or Static IP, directly in
the device finding list. Refer to the following section for changing the IP Camera’s network property.
for further details.
3.3 Example of Changing IP Camera’s Network Property
Users can directly change an IP Camera’s network property, ex. from static IP to DHCP, in the finding
device list. The way to change the IP Camera’s network property is specified below:
Step 1: In the finding device list, click on the IP Camera that you would like to change its network
property. On the selected item, right click and select “Network Setup.” Meanwhile, record the IP
Camera’s MAC address, for future identification.
Step 2: The “Network Setup” page will come out. Select “DHCP,” and press “Apply” button down the
page.
- 16 -
Page 17
Step 3: Click “OK” on the Note of setting change. Wait for one minute to re-search the IP Camera.
Step 4: Click the “Device Search” button to search all the devices. Then select the IP Camera with the
correct MAC address. Double click on the IP Camera, and the login window will come out.
Step 5: Enter User name and Password to access the IP Camera.
3.4 Installing DC Viewer Software Online
For the initial access to the IP Camera, a client program, DC Viewer, will be automatically installed to
your PC when connecting to the IP Camera.
If the Web browser doesn’t allow DC Viewer installation, please check the Internet security settings or
- 17 -
Page 18
ActiveX controls and plug-ins settings (see Appendix B: Internet Security Settings) to continue the
process.
The Information Bar (just below the URL bar) may come out and ask for permission to install the
ActiveX Control for displaying video in browser (see the figure below). Right click on the Information Bar
and select “Install ActiveX Control…” to allow the installation.
Then the security warning window will pop up. Click “Install” to carry on software installation.
Click “Finish” to close the DC Viewer window when download is finished.
Once login to the IP Camera, users will see the Home page as shown below:
NOTE: The “talk” button below the screen only displays in ICA-HM126 Series IP Camera.
3.5 Administrator / User Privileges
“Administrator” represents the person who can configure the IP Camera and authorize user’s access to
the camera; “User” refers to whoever has access to the camera with limited authority, i.e. entering
Home and Camera setting pages.
- 18 -
Page 19
3.6 Lens Adjustment
The image displays on the Home page when successfully accessing to the IP Camera. Adjust the
camera’s focus to produce a clear image. Please refer to the procedure below.
ICA-HM131 Series Lens Adjustment
Step 1: Unscrew the IP Camera’s cover.
Step 2: Loosen the focus fixed screw, and rotate the lens counter-/clockwise to adjust focus; loosen the
tilt fixed screw, and adjust the camera’s tilt angle.
Tilt Fixed Screw
Focus Fixed Screw
- 19 -
Page 20
Chapter 4
4
Configuration & Operation
The IP Camera is provided with a user-friendly browser-based configuration interface, and a free
bundled CMS (Central Management System) for record and playback video. In this chapter, information
about main page introduction, system related settings and camera settings will be described in detail.
4.1 Browser-based Viewer Introduction
The figure below shows the Home page of the IP Camera’s Viewer Window.
View
er Window
Setting Tabs
Video Format
Selection
There are five tabs: Home, System, Streaming, Camera and Logout on the top of the viewer window.
Home
Video Compression info
Time Display
Time Display
Snapshot Button
Talk Button
Display Mode
Users can monitor live video of the targeted area.
System setting
Thedministrator can set host name, system time, root password, network related settings, etc. Further
details will be interpreted in section 4.3 System Related Settings
- 20 -
.
Page 21
Streaming setting
The administrator can modify video resolution and rotate type and select audio compression mode in
this page.
Camera setting
Users can adjust various camera parameters, including <Exposure>, <White Balance>, <Brightness>,
<Sharpness>, <Contrast> and <Digital Zoom>.
Logout
Click on the tab to re-login the IP Camera with another username and password.
4.2 Home Page
In the Home page, there are several function buttons right down the displayed image.
Screen Size Adjustment
Image display size can be adjusted to x1/2 and full screen.
Digital Zoom Control
In the full screen mode, users can implement digital zoom by right clicking the mouse, rotating the
mouse wheel (for zoom in/out) and dragging the mouse into any direction.
Talk
Talk function allows the local site talks to the remote site. This function is only open to “User” who has
been granted this privilege by the Administrator.
- 21 -
Page 22
NOTE: This function is only available for ICA-HM126 Series IP Camera.
Snapshot
Press the button, and the JPEG snapshots will automatically be saved in the appointed place.
The default place of saving snapshots is: C:\.
4.3 System Related Settings
The figure below shows all categories under the “System” tab. Each category in the left column will be
explained in the following sections.
NOTE: The “System” configuration page is only accessible by the Administrator.
4.3.1 Host Name and System Time Setting
Press the first category: <System> in the left column; the page is shown as below.
- 22 -
Page 23
Host Name
The name is for camera identification. If Motion Detection function is enabled and is set to send alarm
message by Mail/FTP, the host name entered here will display in the alarm message.
Time Zone
Select the time zone you are in from the drop-down menu.
Sync with Computer Time
Select the item, and video date and time display will synchronize with the PC’s.
Manual
The Administrator can set video date, time and day manually. Entry format should be identical with that
shown next to the enter fields.
Sync with NTP server
Network Time Protocol (NTP) is an alternate way to synchronize your camera’s clock with a NTP server.
Please specify the server you wish to synchronize in the enter field. Then select an update interval from
the drop-down menu. For further information about NTP, please see the web site: www.ntp.org.
4.3.2 Security
Click the category: <Security>, and the page is shown as the figure below.
- 23 -
Page 24
Root password
Change the administrator’s password by inputting the new password in both text boxes. The input
characters/numbers will be displayed as dots for security purposes. After clicking <Save>, the web
browser will ask the Administrator for the new password for access. The maximum length of the
password is 14 digits.
NOTE: The following characters are valid: A-Z, a-z, 0-9, !#$%&’-.@^_~.
Add user
Type the new user's name and password and click <Add> to add the new user. Both user name and
password can be up to 16 characters. The new user will be displayed in the user name list. There is a
maximum of twenty user accounts. Each user can be assigned the privileges of “Camera control”
and/or “Listen”.
•I/O access
This item supports fundamental functions that enable users to view video when accessing to the
camera.
•Camera control
This item allows the appointed User to change camera parameters on the Camera Setting page.
•Talk / Listen
Talk and Listen functions allow the appointed user in the local site (PC site) communicating with, for
instance, the administrator in the remote site.
- 24 -
Page 25
NOTE: The ICA-HM131 Series do not have the Talk function.
Manage User
Delete user
To delete a user, pull down the user list, and select the user name you wish to delete. Then click
<Delete> to remove it.
Edit user
Pull down the user list and select a user name. Click <Edit> to edit the user’s password and privilege.
NOTE: It is required to enter the User password as well as select the function open to the
user. When finished, click <Save> to modify the account authority.
- 25 -
Page 26
4.3.3 Network
Click <Network> in the left column, and the page will display as shown below.
Users can choose to use fixed IP address or dynamic (DHCP) IP address. The following is descriptions
for the two ways of setting IP address.
Get IP address automatically (DHCP)
The camera’s default setting is “Use fixed IP address”. Please refer to the previous section Chapter 3.
Accessing Camera for logging in with the default IP address.
If select “Get IP address automatically”, after the IP Camera restarts, users can search it through the
installer program: DeviceSearch.exe, which can be found in “DeviceSearch” folder in the supplied CD.
NOTE: Please make the record of the IP Camera’s MAC address, which can be found in
the label of the camera, for identification in the future.
Use fixed IP address
To setup static IP address, select “Use fixed IP address” and move the cursor to the IP address blank
(as indicated below) and insert the new IP address, ex. 192.168.0.250; then go to the Default gateway
(explained latter) blank and change the setting, ex. 192.168.0.250. Press “Save” to confirm the new
setting.
- 26 -
Page 27
When using static IP address to login to the IP Camera, users can access it either through
“DeviceSearch” software (see Chapter 3. Accessing Camera
) or input the IP address in the URL bar
and press “Enter”.
General
•IP address
This is necessary for network identification.
•Subnet mask
It is used to determine if the destination is in the same subnet. The default value is “255.255.255.0”.
•Default gateway
This is the gateway used to forward frames to destinations in different subnet. Invalid gateway setting
will fail the transmission to destinations in different subnet.
•Primary DNS
Primary DNS is the primary domain name server that translates hostnames into IP addresses.
•Secondary DNS
Secondary DNS is a secondary domain name server that backups the primary DNS.
- 27 -
Page 28
•Web Server port
The default web server port is 80. Once the port is changed, the user must be notified the change for
the connection to be successful. For instance, when the Administrator changes the HTTP port of the IP
Camera whose IP address is 192.168.0.100 from 80 to 8080, the user must type in the web browser
“http://192.168.0.100:8080” instead of “http://192.168.0.100”.
Advanced
•RTSP port
RTSP port could be set from 1 to 65535. (Normal Setting Port: 554, 1024 ~65535)
•MJPEG over HTTP port
The default setting of HTTP Port is 8008; setting range: 1024 ~65535.
NOTE: Be aware to choose the different port from the one set for the web server port.
4.3.4 DDNS
Dynamic Domain Name System (DDNS) allows a host name to be constantly synchronized with a
dynamic IP address. In other words, it allows those using a dynamic IP address to be associated to a
static domain name so others can connect to it by name.
Enable DDNS
Check the item to enable DDNS.
- 28 -
Page 29
Provider
Select one DDNS host from the provider list.
Host name
Enter the registered domain name in the field.
Username/E-mail
Enter the username or e-mail required by the DDNS provider for authentication.
Password/Key
Enter the password or key required by the DDNS provider for authentication.
4.3.5 Mail
The Administrator can send an e-mail via Simple Mail Transfer Protocol (SMTP) when motion is
detected. SMTP is a protocol for sending e-mail messages between servers. SMTP is a relatively
simple, text-based protocol, where one or more recipients of a message are specified and the message
text is transferred. The configuration page is shown as follows:
Two sets of SMTP can be configured. Each set includes SMTP Server, Account Name, Password and
E-mail Address settings. For SMTP server, contact your network service provider for more specific
information.
- 29 -
Page 30
4.3.6 FTP
The Administrator can set as sending alarm message to a specific File Transfer Protocol (FTP) site
when motion is detected. Users can assign alarm message to up to two FTP sites. The FTP setting
page is shown below. Enter the FTP details, which include server, server port, user name, password
and remote folder, in the fields. Press “Save” when finished.
4.3.7 Application (ICA-HM126 Series)
The ICA-HM126 Series IP Camera equips one alarm input and one relay output for cooperating with
alarm system to catch events’ images. The alarm configuration page is also shown below.
- 30 -
Page 31
Alarm Switch
The Administrator can enable or disable the alarm function.
Alarm Type
Select an alarm type, “Normal close” or “Normal open,” that corresponds with the alarm application.
Alarm Output
Define alarm output signal “high” or “low” as the normal alarm output status according to the current
alarm application.
Action (Multi-option)
The Administrator can specify alarm actions that will take when the alarm is triggered. All options are
listed as follows:
•Enable Alarm Output
Select the item to enable alarm relay output.
•Send Alarm Message by FTP/E-Mail
The Administrator can select whether to send an alarm message by FTP and/or E-Mail when an
alarm is triggered.
•Upload Image by FTP
Select this item, and the Administrator can assign a FTP site and configure various parameters as
shown in the figure below. When the alarm is triggered, event images will be uploaded to the
appointed FTP site.
- 31 -
Page 32
•Upload Image by E-Mail
Select this item, and the Administrator can assign an e-mail address and configure various
parameters as shown in the figure below. When the alarm is triggered, event images will be sent
to the appointed e-mail address.
NOTE: Make sure SMTP or FTP configuration has been completed. See section 4.3.5 Mail
and 4.3.6 FTP
for further details.
File Name
Enter a file name in the blank, ex. image.jpg. The uploaded image’s file name format can be set in
this section. Please select the one that meets your requirements.
•Add date/time suffix
File name: imageYYMMDD_HHNNSS_XX.jpg
Y: Year, M: Month, D: Day
H: Hour, N: Minute, S: Second
X: Sequence Number
•Add sequence number suffix (no maximum value)
File name: imageXXXXXXX.jpg
X: Sequence Number
•Add sequence number suffix (limited value)
- 32 -
Page 33
File Name: imageXX.jpg
X: Sequence Number
The file name suffix will end at the number being set. For example, if the setting is up to “10,” the
file name will start from 00, end at 10, and then start all over again.
•Overwrite
The original image in the FTP site will be overwritten by the new uploaded file with a static
filename.
Save
After complete all the settings mentions above, please click on the Save button to save all the
settings in this page.
4.3.8 Motion Detection
Motion Detection function allows detecting suspicious motion and triggering alarms when motion
volume in the detected area reaches/exceeds the determined sensitivity threshold value.
In the Motion Detection setting page, there is a frame (Motion Detection Window) displayed on the
Live View Pane. The Motion Detection Window is for defining the motion detection area. To change the
size of the Motion Detection Window, move the mouse cursor to the edge of the frame and draw it
outward/inward. Moving the mouse to the center of the frame can shift the frame to the intended
location.
Up 10 Motion Detection Windows can be set. Press the “add” button under the Live View Pane to add a
Motion Detection Window. To cancel a Motion Detection Window, move the mouse cursor to the
- 33 -
Page 34
selected Window, and click on the “delete” button.
If Motion Detection function is activated, the pop-off window (Motion) with indication of motion will be
shown.
When motion is detected, the signals will be displayed on the Motion window as shown below.
Detailed settings of Motion Detection are described as follows:
Motion Detection
You will be able to turn on/off Motion Detection in System section. Default setting is Off.
Motion Detection Setting
Users could adjust various parameters of Motion Detection in this section.
•Sampling pixel interval [1-100]:
The default value is 10, which means system will take one sampling pixel for every 10 pixel.
•Detection level [1-100]:
The default level is 10. The item is to set detection level for each sampling pixel; the smaller the value,
the more sensitive it is.
•Sensitivity level [1-100]:
The default level is 80, which means if 20% or more sampling pixels are detected differently, system will
detect motion. The bigger the value, the more sensitive it is. Meanwhile, when the value is bigger, the
red horizontal line in the motion indication window will be lower accordingly.
- 34 -
Page 35
•Time interval (sec) [0-7200]:
The default interval is 10. The value is the interval between each detected motion.
Users could adjust the parameter and level of Motion Detection Settings.
Microsoft ® Internet Explorer 6.0 or later, Cam Viewer Plus Lite/Pro
10 areas definable
30fps for all resolutions
Environment Specifications
Power Requirement
Dimension (W x D x H)
Weight
Power Consumption
Operating Temperature
Operating Humidity
Emission
IEEE 802.3af
Φ110 x 50 mm
180g
3.8W max.
0 ~ 50 Degree C
10 ~ 90% (non-condensing)
CE, FCC
- 54 -
Page 55
Appendix B: Internet Security Settings
If ActiveX control installation is blocked, please either set Internet security level to default or change
ActiveX controls and plug-ins settings.
Internet Security Level: Default
Step 1: Start the Internet Explorer (IE).
Step 2: Select <Tools> from the main menu of the browser. Then Click <Internet Options>.
Step 3: Click the <Security> tab, and select <Internet>.
Step 4: Down the page, press “Default Level” (see the figure above) and click “OK” to confirm the
setting. Close the browser window, and open a new one later when accessing the IP Camera.
- 55 -
Page 56
ActiveX Controls and Plug-ins Settings
Step 1~3: Refer to the previous section above.
Step 4: Down the page, press “Custom Level” (see the figure below) to change ActiveX controls and
plug-ins settings.
The Security Settings screen is displayed as below:
- 56 -
Page 57
Step 5: Under “ActiveX controls and plug-ins”, set ALL items (as listed below) to <Enable> or
<Prompt>.
ActiveX controls and plug-ins settings:
1. Automatic prompting for ActiveX controls
2. Binary and scrip behaviors
3. Download signed ActiveX controls
4. Download using ActiveX controls
5. Initialize and script ActiveX not marked as
safe
6. Run ActiveX controls and plug-ins
7. Script ActiveX controls marked safe for
scripting
Step 6: Click <OK> to accept the settings and close the <Security> screen.
Step 7: Click <OK> to close the Internet Options screen.
Step 8: Close the browser window, and restart a new one later for accessing the IP Camera.
- 57 -
Page 58
Appendix C: DC Viewer Download Procedure
The procedure of DC Viewer software download is specified as follows.
Step 1: In the DC Viewer installation page, click “Next” for starting installing.
Step 2: Setup starts. Please wait for a while until the loading bar runs out.
- 58 -
Page 59
Step 3: Click “Finish” to close the DC Viewer installation page.
Then, the IP Camera’s Home page will display as follows:
- 59 -
Page 60
Appendix D: Frequently Asked Questions
Q1 [ICA-HM126/131 Series] How can I know the IP address of IP camera?
The default IP address is 192.168.0.20, and you could use the Device Search utility on the
Ans:
bundled CD to obtain the current IP address of IP camera. Please refer to the user’s manual
for more detail information.
Q2 [ICA-HM131/131R] How to supply power to ICA-HM131/131R?
Ans:
Ans:
Ans:
Ans:
The LAN socket of IP Camera is compliant with IEEE802.3af standard PoE interface, and IP
Camera is necessary supplied power through PoE Switch/Hub device.
Q3 [ICA-HM131/131R] How to adjust the focus and angle of lens?
Use the L-type spanner in the bundled package to unscrew the cover. Loosen the focus fixed
screw, and rotate the lens counter-/clockwise to adjust focus; loosen the tilt fixed screw, and
adjust the camera’s tilt angle. You could get detail descriptions on the user’s manual.
Q4 [ICA-HM131/131R] How to reset IP camera to default setting?
The Reset button at the side of lens. Use the L-type spanner in the bundled package to
unscrew the cover at first, and press the button with a proper tool to default setting.
Q5 [ICA-HM126/126R] How to reset IP camera to default setting?
The Reset button at the rear side of camera, press the button with a proper tool to default
setting.
[ICA-HM126/131 Series] After upgraded firmware, why can’t see the picture for MJPEG
Q6
video format via web browser?
That because the system with the newer video formats, and the PC need to install the newer
DC Viewer software to appear the video on PC properly.
Ans:
- 60 -
Please go to “Control Panel -> Add or Remove Programs” to remove old DV Viewer software
at first. Then connect to IP camera via web browser and it will prompt to install the new DC
Viewer software in to PC.
Loading...