PLANET ICA-3280, ICA-4280, ICA-A3280, ICA-A4280, ICA-M3580P User Manual

...
H.265 Smart IR PoE IP Camera
ICA-x80 series
1. Introduction
Thank you for purchasing PLANET H.265 Smart IR PoE IP Camera. The “ICA-x80 series” is used as an alternative name in this Quick Installation Guide. The following is the ICA-x80 series:
2. Package Contents
Open the box of the ICA-x80 series and carefully unpack it. The box should contain the following items:
z The IP Camera x 1
z Quick Installation Guide x 1
z Screw Package x 1
z Waterproof Connector Package x 1
z Drill Template x 1
If any item is found missing or damaged, please contact your local reseller for replacement.
ICA-3280 H.265 1080p Smart IR Bullet IP Camera
ICA-A3280
ICA-A4280
ICA-M3580P
ICA-M4580P
Note
H.265 1080p Smart IR Bullet IP Camera with
Articial Intelligence
H.265 1080p Smart IR Dome IP Camera with
Articial Intelligence
H.265 5 Mega-pixel Smart IR Bullet IP Camera with Remote Focus and Zoom
H.265 5 Mega-pixel Smart IR Dome IP Camera with Remote Focus and Zoom
– 1 – – 2 –
It is recommended to use Internet Explorer 8.0 or above to access the ICA-x80 series. If the Web interface of the ICA-x80 series is not accessible, please turn off the anti-virus software or firewall and then try it again.
4. Starting Web Management
The following shows how to start up the Web Management of the
ICA-x80 series. Note the ICA-x80 series is congured through an
Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address.
3. Requirements
z Workstations running Windows XP/2003/2008/Vista/7/8/10, MAC
OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP protocols.
z Workstations are installed with Ethernet NIC (Network Interface
Card).
z Ethernet Port Connection
Network cables -- Use standard network (UTP) cables with
RJ45 connectors.
The above PC is installed with Web browser.
1. Download the “PLANET Search Tools” utility from the following PLANET website link: http://www.planet.com.tw/en/support/down loads?method=keyword&keyword=PLANET+Search+Tools&view= 6#list
2. Install the “PLANET Search Tools” utility.
3. After the camera utility is launched, all cameras found in your local area network will be displayed.
4. The existing ICA-x80 series in the local network.
5. Search the ICA-x80 series in the network.
6. Modify the IP parameters of the selected ICA-x80 series.
7. Select the ICA-x80 series you want to congure and double-click
on it.
8. You will be connected to the ICA-x80 series via web browser automatically.
User PC
(192.168.0.X)
1. The ICA-x80 series supports IEEE 802.3af; be reminded to power either from AC to DC adapter or
Note
For example, the ICA-x80 series default network type is DHCP Client; to search the current IP address of the ICA-x80 series, follow the procedure below:
802.3af PoE switch.
2. The AC to DC adapter is not included in the package.
Ethernet Switch
Figure 4-1: IP Management Diagram
– 3 –
IP camera
Figure 4-2: PLANET Search Tools Utility Screen
– 4 –
9. Without DHCP server, the ICA-x80 series default IP address
power consumption, it is strongly suggested to remove the power cable from the device if this device is not intended to be active.
is 192.168.0.20, then the manager PC should be set to
192.168.0.x (where x is a number between 1 and 254, except
20), and the default subnet mask is 255.255.255.0.
Logging in to the ICA-x80 Series
When the following dialog box appears, please enter the default user name and password “admin”. The login screen in Figure 4-3 appears.
Default Username: admin Default Password: admin
Figure 4-3: ICA-x80 series Web Login Screen
The following web screen based on ICA-M4580P will
Note
be the same as that of ICA-x80 series.
After entering the username and password, the main screen appears as Figure 4-4 shows.
Figure 4-4: Web Main Screen of ICA-x80 series
Now, you can use the Web management interface to continue the ICA-x80 series management.
Please refer to the user’s manual for more.
5. Recovering Back to Default
Conguration
IP Address has been changed or admin password has
been forgotten –
To reset the network type to the default “DHCP Client” with IP address “192.168.0.20” or reset the login password to default
– 5 – – 6 –
value, press the hardware-based reset button for about 10 seconds. After the ICA-x80 series is rebooted, you can log in the management Web interface within the factory default mode.
Figure 5-1: Reset Button
Customer Support
ICA-x80 Series User’s Manual: https://www.planet.com.tw/en/support/downloads?&method=keywo rd&keyword=ICA-x80+series&view=3#list
Android APP IOS APP
Copyright © PLANET Technology Corp. 2020. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.
Thank you for purchasing PLANET products. You can browse our
online FAQ resource and User’s Manual on PLANET Web site rst
to check if it could solve your issue. If you need more support information, please contact PLANET support team.
PLANET online FAQs: http://www.planet.com.tw/en/support/faq?method=category&c1=8
Support team mail address: support@planet.com.tw
– 7 –
PLANET Technology Corp.
10F., No. 96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan
Warning:
This device is compliant with Class A of CISPR 32. In a residential environment this device may cause radio interference.
Energy Saving Note of the Device
This power required device does not support Standby mode operation. For energy savings, please remove the power cable to disconnect the device from the power circuit. Without removing the power cable, the device will still consume power from the power source. In view of Saving the Energy and reducing the unnecessary
2011-AB8200-000
– 8 –
Loading...