PLANET GTP-80x User Manual

1000Base-X to 10/100/1000Base-T
802.3at PoE Media Converter
GTP-802 / GTP-802S / GTP-805A
User’s Manual
Trademarks
Copyright © PLANET Technology Corp. 2011.
Contents subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp. The information in this manual is subject to change without notice. All other trademarks belong to their respective owners.
Disclaimer
PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and makes no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or
tness for a particular purpose.
Information in this User’s Manual is subject to change without notice and does not represent a commitment on the part of PLANET. PLANET assumes no responsibility for any inaccuracies that may be contained in this User’s Manual. PLANET makes no commitment to update or keep current the information in this User’s Manual, and reserves the right to make improvements to this User’s Manual and/or to the products described in this User’s Manual, at any time without notice.
If you nd information in this manual that is incorrect,
FCC Warning
This equipment has been tested and found to comply with the regulations for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this user’s guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
Energy Saving Note of the Device
This power required device does not support Standby mode operation.
For energy saving, please remove the DC-plug to disconnect the device from the power circuit.
Without removing the DC-plug, the device will still consume power from the power source. In the view of Saving the Energy and reduce the unnecessary power consuming, it is strongly suggested to remove the DC-plug for the device if this device is not intended to be active.
WEEE Warning
To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment, end
users of electrical and electronic equipment should understand the meaning of the crossed-out wheeled bin symbol. Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately.
Revision
PLANET 1000Base-X to 10/100/1000Base-T 802.3at PoE+ Media Converter User’s Manual
For Models: GTP-802 / GTP-802S / GTP-805A
Rev 1.0 (May 2011)
Part No. EM-GTP80X_V1.0 (2350-AA4480-000)
Table of Contents
1. Overview .........................................................................6
About the Power over Ethernet Injector .............................. 6
2. Model List ........................................................................ 7
3. Checklist .......................................................................... 8
4. Product Outlook ................................................................9
5. Link Fault Pass Through (LFP) .......................................... 11
Link Loss Carry Forward (LLCF) ....................................... 11
Link Loss Return (LLR) .................................................... 12
6. Installing the Converter ................................................... 14
7. PoE Function .................................................................. 16
8. LED Indication ................................................................ 18
9. Cable Connection Parameter ............................................ 19
10. GTP-80X Technical Specications .................................... 20
APPENDIX A ....................................................................... 21
A.1 Device's RJ-45 Pin Assignments ................................. 21
A.2 RJ-45 Cable Pin Assignment ...................................... 22
A.3 Fiber Optical Cable Connection Parameter ................... 23
1. Overview
converter provides Power over Ethernet power injector function which is able to drive one IEEE 802.3at / 802.3af compliant powered devices.
About the Power over Ethernet Injector
The GTP-80X is an IEEE 802.3at / 802.3af Power over Ethernet Injector that provide DC 52V over Ethernet cables. To inserts DC Voltage into Cat.5 / 5e / 6 cables, allowing the cable between the Injector (GTP-80X) and PoE PD (Powered Device) to transfer data and power simultaneously. The maximum distance between the Injector (GTP-80X) and PoE PD is 100 meters. The GTP-80X is combines the Ethernet digital data with power over the twisted pair cables as an IEEE 802.3at / 802.3af Power over Ethernet Injector. And using the Power over Ethernet splitter, it can separate the digital data and the power into two outputs.
The benets of PLANET GTP-80X are like cost saving, easy for
networking planning and higher reliability. What’s more, upon any IEEE 802.3at / 802.3af devices installed, the GTP-80X or PD all can make the connection while migrating and the Ethernet digital packets, such as connecting the GTP-80X to an IEEE
802.3at / 802.3af complied devices, wireless AP or IP Camera.
6
2. Model List
Your 802.3at PoE Media Converter comes with three of the following models.
GTP-802: l
Multi-Mode SC interface ber connector, up to 550m
GTP-802S: l
Single Mode SC interface ber connector, up to 10km
GTP-805A: l
Multi / Single Mode LC interface connector, distance is vary on
SFP module
In the following sections, the term “GTP-80X” indicates the product family above.
7
3. Checklist
Note
Your GTP-80X box should contain the following items:
1000Base-X to 10/100/1000Base-T 802.3at PoE Media l Converter x 1
User’s Manual x 1 l
AC-DC Adapter (Input: 52V~56V DC, 0.58A max.) x 1 l
Power Cord x 1 l
If any of these are missing or damaged, please contact your dealer immediately, if possible, retain the carton including the original packing material, and use them against to repack the product in case there is a need to return it to us for repair.
GTP-805A is with one vacant SFP module slot. The mini GBIC SFP module is not bundled with in the package.
8
4. Product Outlook
52V~56V DC
LFP
PWR
Mini-GBIC
OFF ON
Fiber TX
LNK ACT
In Use
PoE
10/100/1000Base-T
PoE Media Converter 1000X to 10/100/1000T
Power over Ethernet
Ethernet+DC
IEEE 802.3at PoE Media Converter
1000Base-X to 10/100/1000Base-T
Overview
The layout of GTP-802 is the same as for GTP-802S
Figure 4-1: Product Outlook of GTP-802/GTP-802S
The layout of GTP-805A
Figure 4-2: Product Outlook of GTP-805A
9
Left View
PWR
Mini-GBIC
Fiber TX
LNK ACT
In Use
PoE
10/100/1000Base-T
PoE Media Converter 1000X to 10/100/1000T
Ethernet+DC
52V~56V DC
LFP
OFF ON
There are one RJ-45 Twisted-Pair jack (Auto-MDI/MDI-X), one
ber-optic connector (vary by model) and four LED indicators.
Figure 4-3: Left View of GTP-802 / GTP-802S
Figure 4-4: Left View of GTP-805A
Right View
One DIP switch for Link Fault Pass Through (LFP) feature, “ON” to turn-on the LLCF and LLR detection. And “OFF” to turn off this feature. Please refer to the following sections for more. Also one DC 52V ~ 56V power socket for the PoE+ Media Converter.
10
Figure 4-5: Right View of GTP-80X
5. Link Fault Pass Through (LFP)
Media
Converter
Management
Station
Switch/Hub
w/SNMP
Management
Station
Media
Converter
Switch/Hub
w/SNMP
TP TP
Fiber
Cable
LFP ONLFP ON
l LED lit = established link ° LED unlit = no link
The LFP function includes the Link Fault Pass Through function (LLCF/LLR) and the DIP Switch design. LLCF/LLR can immediately alarm administrators the problem of the link media
and provide efcient solution to monitor the net. The DIP Switch
provides disable or enable the LFP function.
LLCF (Link Loss Carry Forward) means when a device connected to the converter and the TP line loss the link, the converter’s
ber will disconnect the link of transmit. LLR (Link Loss Return) means when a device connected to the converter and the ber line loss the link, the converter’s ber will disconnect the link
problem of the link media and provide efcient solution to
monitor the net.
Link Loss Carry Forward (LLCF)
GTP-80X incorporates an LLCF function for troubleshooting a remote connection. When LFP function is enabled, the FL / TP ports do not transmit a link signal until they receive a link signal from the opposite port.
good link status using GTP-80X for remote connectivity.
11
If the connection breaks, GTP-80X that link loss forward to
Media
Converter
Management
Station
Switch/Hub
w/SNMP
Management
Station
Media
Converter
Switch/Hub
w/SNMP
TP TP
Fiber
Cable
LFP ONLFP ON
l LED lit = established link ° LED unlit = no link
Media
Converter
Management
Station
Switch/Hub
w/SNMP
Station
Media
Converter
Switch/Hub
Fiber
Cable
LFP OFFLFP ON
l LED lit = established link ° LED unlit = no link
the Switch / Hub that generates a trap to the management station. The administrator can then determine the source of the problem.
*Units are shipped with the LFP function disable (OFF).
Link Loss Return (LLR)
The ber ports of GTP-80X have been designed with an LLR
function for troubleshooting a remote connection. LLR works in conjunction with LLCF.
When LFP function is enabled, the port’s transmitter shuts down when its receiver fails to detect a valid receive link. LLR should only be enabled on one end of the link and is typically enabled on either the unmanaged or remote device.
The diagram below shows a typical network conguration with
a good link status using GTP-80X for remote connectivity. Note that LLR and LLCF are enabled as indicated in the diagram.
12
Media
Converter
Management
Station
Switch/Hub
w/SNMP
Station
Media
Converter
Switch/Hub
Fiber
Cable
LFP OFFLFP ON
l LED lit = established link ° LED unlit = no link
Note
diagram box below), the converter with LLR function will return a no-link condition to its link partner. With LLCF function also enabled, the no-link condition is carried forward to the switch/ hub where a trap is generated to the management station, and the administrator can then determine the source of the loss.
LFP function is turn-off in default. This feature can also be turned via the side DIP-switch. If you are not familiar with the network installa­tion and for diagnostic purpose (i.e. check which end is broken), you can turn it on and reset the converter to make it take effect. Otherwise, please remain it in the default position.
13
6. Installing the Converter
1000Base-SX/LX
SC Fiber
10/100/1000Base-T UTP
Please follow these steps to install the PoE+ Media converter:
Turn off the power of the device / station in a network to l which the GTP-80X will be attached.
Ensure that there is no activity in the network. l
Attach ber cable from the GTP-80X to the ber network. l
Attach a Cat.5 / 5e / 6 UTP cable from the 10/100/1000Base-T l network to the RJ-45 port on the GTP-80X.
Connect the 52V~56V DC power adapter to the GTP-80X and l verify that the Power LED lights up.
Turn on the power of the device / station, the TX Link and FX l Link LEDs should light when all cables are attached.
Figure 6-1: GTP-802 / GTP-802S Installation
14
1000Base-SX/LX SFP transceiver
1000Base-SX/LX LC Fiber
10/100/1000Base-T UTP
Note
Figure 6-2: GTP-805A Installation
RJ-45 / STP, UTP Cat5 / 5e / 6, straight / cross­over cable is accepted. Please refer to section 9 for more about the wiring distance of your TP, Optic-fiber networks.
15
7. PoE Function
550m / 10km 100 meters
PoE+
Speed Dome
Fiber Switch
Power DC 52V~56V
1000
PoE
DC
AC
GTP-802 / GTP-802S
550m~120km 100 meters
PoE+
Speed Dome
Fiber Switch
Power DC 52V~56V
1000
PoE
DC
AC
GTP-805A
Power Line (AC)
AC
DC
Power Line (DC)
1000Base-SX/LX Fiber-optic
PoE
1000Base-T UTP with PoE
Power
Data
Power
Data
Data
Data
GTP-80X and the IEEE 802.3at / 802.3af Injector / Splitter equipment installation:
Before your installation, it is recommended to check your network environment. If there is any IEEE 802.3at / 802.3af devices need to power on, the GTP-80X can provide you a way to supply power for this Ethernet device conveniently and easily.
The GTP-80X equips an AC-DC adapter with DC 52V~56V input and it injects the DC power into the pin of the twisted pair cable (Pin 4, 5, 7 and 8).
16
For the places where are hard to nd the power inlet, the
550m / 10km 100 meters
Fiber Switch
PoE Splitter
Wireless AP
Power DC 52V~56V
1000
PoE
DC
AC
GTP-802 / GTP-802S
550m~120km 100 meters
Fiber Switch
1000
DC
GTP-805A
Power Line (AC)
AC
DC
Power Line (DC)
1000Base-SX/LX Fiber-optic
1000Base-T UTP
PoE
1000Base-T UTP with PoE
Power
DataData
Data
Power DC 52V~56V
AC
DC
PoE Splitter
IP Camera
PoE
Power
Data
DC
GTP-80X provide the easiest way to power your Ethernet devices such as PLANET IEEE 802.3at / 802.3af Power over Ethernet Splitter (POE-151S / 152S / 161S) with Internet Camera or PoE Wireless Access Point installed in the wild rang place.
17
8. LED Indication
System
LED Color Function
PWR Green Light Indicate the device is powered.
10/100/1000Base-T Port
LED Color Function
Indicate that the PoE+ Media
Blink
Converter is actively sending or receiving data over that port.
LNK/ACT Green
PoE in Use Orange
1000Base-X Fiber Port
LED Color Function
LNK/ACT Green
Indicate that the port is link up
Light
at 10/100/1000Mbps.
Indicate that the port is link
Off
down.
Indicate that the port is
Light
providing DC 52V to remote powered device.
Indicate that the port is not
Off
providing DC 52V to remote powered device.
Indicate that the PoE+ Media
Blink
Converter is actively sending or receiving data over that port.
Light Indicate that the port is link up.
Indicate that the port is link
Off
down.
18
9. Cable Connection Parameter
The limitations are as below:
Duplex Connection Limitation (max.)
Twisted Pair
Half / Full
Multi-Mode Converters
MM Half
MM Full
Single-Mode Converters
SM Full
Multi / Single Mode Converters
Full
Node to Node Node to Switch/Hub
Node to Node Node to Switch
Node to Node Node to Switch
Node to Node Node to Switch
Node to Node Node to Switch
100 meters
412 meters
GTP-802: 220 / 550 meters
GTP-802S: 10 kilometers
GTP-805A: Vary on SFP module
19
10. GTP-80X Technical Specications
The GTP-80X comes with the following standard features:
lStandard: IEEE 802.3 / 802.3u / 802.3ab, 10/100/1000Base-T
IEEE 802.3at pre-standard / 802.3af Power over Ethernet standard
lConnectors:
 One RJ-45 (Auto-MDI/MDI-X) Twisted Pair, EIA568 with PoE
 One Fiber-optic, connector-type vary with model
lData Transfer Rate: 10/100/1000Mbps (TP), 1000Mbps
(Fiber)
lDuplex mode support: Full or Half-duplex mode by Auto-
Negotiation (TP)
lLED Indicators: PWR, FX LNK/ACT, TP LNK/ACT, PoE in Use
lPoE Power Output: DC 52V, Max. 30 Watts
lPower Pin Assignment: 4/5, 7/8 / Mid-Span
lPower Supply: DC 52V, 0.58A, external AC-DC adapter
lAmbient Temperature: 0° to 50°C (operating)
lHumidity: 5% to 90% (non-condensing)
lDimension: 26 x 70 x 94mm (H x W x D)
lCable:
UTP: Cat 5 / 5e / 6 UTP cable
Fiber: MM: 50/125 µm or 62.5/125 µm optic ber
Fiber: SM: 9/125 µm optic ber
Connecting to Router, Bridge, or Switch, Hub, please refer to the device’s Technical Manual.
20
APPENDIX A
A.1 Device's RJ-45 Pin Assignments
1000Mbps, 1000Base-T
RJ-45 Connector pin assignment
Contact MDI MDI-X
1 BI_DA+ BI_DB+
2 BI_DA- BI_DB-
3 BI_DB+ BI_DA+
4 BI_DC+ BI_DD+
5 BI_DC- BI_DD-
6 BI_DB- BI_DA-
7 BI_DD+ BI_DC+
8 BI_DD- BI_DC-
10/100Mbps, 10/100Base-TX
RJ-45 Connector pin assignment
Contact
1 Tx + (transmit) Rx + (receive)
2 Tx - (transmit) Rx - (receive)
3 Rx + (receive) Tx + (transmit)
4, 5 Not used
6 Rx - (receive) Tx - (transmit)
7, 8 Not used
Implicit implementation of the crossover function within a twisted-pair cable, or at a wiring panel, while not expressly forbidden, is beyond the scope of this standard.
MDI Media Dependant
Interface
MDI-X Media Dependant
Interface -Cross
21
A.2 RJ-45 Cable Pin Assignment
Straight Cable
Cross Over Cable
SIDE 1
SIDE 1
SIDE 2
SIDE 1
SIDE 2
12345678
12345678
12345678
12345678
SIDE 2
1 = White/Orange 2 = Orange 3 = White/Green 4 = Blue 5 = White/Blue 6 = Green 7 = White/Brown 8 = Brown
1 = White/Orange 2 = Orange 3 = White/Green 4 = Blue 5 = White/Blue 6 = Green 7 = White/Brown 8 = Brown
SIDE 1 SIDE 2
1 = White/Orange 2 = Orange 3 = White/Green 4 = Blue 5 = White/Blue 6 = Green 7 = White/Brown 8 = Brown
1 = White/Green 2 = Green 3 = White/Orange 4 = Blue 5 = White/Blue 6 = Orange 7 = White/Brown 8 = Brown
There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight cable and crossover cable connection:
Figure A-1: Straight-Through and Crossover Cable
Please make sure your connected cables are with same pin assignment and color as above picture before deploying the cables into your network.
22
A.3 Fiber Optical Cable Connection Parameter
The wiring details are as below:
Fiber Optical Patch Cables:
Standard Fiber Type Cable Specication
1000Base-SX (850nm) Multi-mode 50/125μm or 62.5/125μm
1000Base-LX (1300nm)
Multi-mode 50/125μm or 62.5/125μm
Single-mode 9/125μm
23
EC Declaration of Conformity
For the following equipment:
*Type of Product:
1000Base-SX/LX/X to 10/100/1000Base-T PoE Media Converter
*Model Number: GTP-802、GTP-802S、GTP-805A
* Produced by: Manufacturer‘s
Name : Planet Technology Corp.
Manufacturer‘s Address: 10F., No.96, Minquan Rd., Xindian Dist.,
New Taipei City 231, Taiwan (R.O.C.)
is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive on (2004/108/EC). For the evaluation regarding the EMC, the following standards were applied:
EN55022 (2006, CLASS A) EN 61000-3-2 (2006) EN 61000-3-3 (1995, A1: 2001, A2: 2005) EN55024 (1998, A1: 2001, A2: 2003) IEC 61000-4-2 (2001) IEC 61000-4-3 (2008) IEC 61000-4-4 (2004) IEC 61000-4-5 (2005) IEC 61000-4-6 (2008) IEC 61000-4-8 (2001) IEC 61000-4-11 (2004)
Responsible for marking this declaration if the:
Manufacturer  Authorized representative established within the EU
Authorized representative established within the EU (if applicable):
Company Name: Planet Technology Corp.
Company Address: 10F., No.96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan
(R.O.C.)
Person responsible for making this declaration
Name, Surname Kent Kang
Position / Title : Product Manager
Taiwan
27thMay, 2011
Place Date Legal Signature
PLANET TECHNOLOGY CORPORATION
e-mail: sales@planet.com.tw http://www.planet.com.tw
10F., No.96, Minquan Rd., Xindian Dist., New Taipei City, Taiwan, R.O.C. Tel:886-2-2219-9518 Fax:886-2-2219-9528