Planet GTP-805A User Manual

1. Product Features
Gigabit Ethernet 802.3at PoE+ Media Converter:
 Interface
z RJ45 interface with Data + Power output
z LC ber optic slot
z 52~56V DC power input socket
 PoE
end-span PSE
z Provides 52~56V DC power over RJ45 Ethernet cable to
devices with Ethernet port
z Supports PoE power up to 30 watts for PoE port
z Auto detects IEEE 802.3at/IEEE 802.3af PoE equipment,
protecting the devices from being damaged by incorrect installation
z Remote power feeding up to 100m
z IEEE 802.3at/IEEE 802.3af splitter devices compatibility
2. Checklist
Your GTP-805A carton should contain the following items:
Media Converter x 1 User’s Manual x 1
AC-DC Adapter (Input: 52~56V DC) x 1
If any item is missing or damaged, please consult the dealer from whom you purchased your Gigabit Ethernet 802.3at PoE+ Media Converter.
The GTP-805A comes with one vacant SFP module slot. The mini GBIC SFP module is not included in
Note
the package.
Power Information
The power jack of the Gigabit Ethernet 802.3at PoE+ Media Converter measures 2.1mm in diameter, and comes with 52~56V DC power input. It conforms to the bundled AC-DC adapter. Should you have the issue of making the power connection, please contact your local sales representative.
4. Link Fault Pass-through (LFP)
The LFP function includes LLCF and LLR. LLCF and LLR can immediately alarm administrators the issue of the link media and provide ecient solution to monitor the network. The LFP function can be disabled or enabled by the DIP switch.
LLCF means when a device is connected to the converter and the TP line loses the link, the converter’s ber will disconnect the transmission link. LLR (Link Loss Return) means when a device is connected to the converter and the ber line loses the link, the converter’s ber will disconnect the transmission link.
LFP function is ON by default setting. If you are familiar with the network installation and for diagnostic purpose (i.e. check which end
Note
is broken), you can turn it off and reset the converter to make it take effect. Otherwise, please remain it in the default position.
1. It is recommended to use PLANET MFB/MGB series 100/1000BASE-FX/SX/LX SFP on the GTP­805A. If you insert an SFP transceiver that is not supported, the GTP-805A will not recognize it.
2. Please check the link-budget of your SFP transceivers and its physical wiring distance. In
Note
some installation, an in-line optical attenuator may be required to protect your transceivers.
3. RJ45/STP, UTP Cat5/5e/6, or straight/crossover cable is accepted; please refer to section 8 for more about the wiring distance of your TP, optic­fiber networks.
PoE Function
The installation of the GTP-805A and the IEEE 802.3at/802.3af Injector/Splitter.
Before your installation, it is recommended to check your network environment. If there is any IEEE 802.3at/802.3af devices that need to be powered on, the GTP-805A can provide you with a way to supply power for this Ethernet device conveniently and easily.
- 1 -
Hardware
z Metal case
z LED indicators
Power LED
PoE-in-use
Fiber LNK/ACT
TP LNK/ACT
z DIP switch: LFP (Link Fault Passthrough) mode selection
z 9K maximum frame size supported
z Wall-mount or DIN-rail installation (optional)
- 3 -
3. Product Outlook
Front Panel
There are one RJ45 twisted-pair jack (auto-MDI/MDI-X), one 100/1000X ber-optic SFP slot and four LED indicators.
10/100/1000T
100/1000X
PoE Media Converter 100/1000X to 10/100/1000T
Figure 1: Front Panel of the GTP-805A
Rear Panel
There is one DIP switch for Link Fault Passthrough (LFP) feature. It is turned on for Link Loss Carry Forward (LLCF) and Link Loss Return (LLR) detection but this feature is not operable when turned o. Please refer to the following sections for more. There is also one DC 52V~56V power socket for the Gigabit Ethernet 802.3at PoE+ Media Converter.
52-56V
Fiber TX
PWR
PoE­in-Use
LNK/ ACT
OFF
Ethernet+DC
LFP
ON
- 5 -
5. Installing The Converter
To install the GTP-805A, simply complete the following steps:
Ethernet Installation
Step 1: Turn o the power of the device/station in a network
to which the GTP-805A will be attached.
Step 2: Ensure that there is no activity in the network. Step 3: Attach ber cable from the GTP-805A to the ber
network.
Step 4: Attach a Cat.5/5e/6 UTP cable from the
10/100/1000BASE-T network to the RJ45 port on the GTP-805A.
Step 5: Connect the 52~56V DC power adapter to the
GTP-805A and verify that the Power LED lights up.
Step 6: Turn on the power of the device/station; the TX Link
and FX Link LEDs should light up when all cables are attached.
100/1000BASE-X SFP Transceiver
100/1000BASE-X LC Fiber
10/100/1000BASE-T UTP
- 7 -
The GTP-805A equips an AC-DC adapter with DC 54V input and it injects the DC power into the pin of the twisted-pair cable (Pins 1, 2, 3 and 6).
550m~120km 100 meters
1000
GTP-805A
Fiber Switch
Power DC 52V~56V
DataData
1000
PoE
Power
PoE
Speed Dome
1000BASE-SX/LX Fiber-optic
1000BASE-T UTP with PoE
PoE+
For the places hard to nd the power inlet, the GTP-805A provides the easiest way to power your powered device such as an IP camera or wireless access point via PLANET IEEE
802.3at/802.3af Power over Ethernet Splitter (POE-161S/162S) over a long distance if necessary.
550m~120km 100 meters
GTP-805A
Power DC 52V~56V
Data
PoE
Power
PoE Splitter
DC
IP Camera
Fiber Switch
Data
1000
- 2 -
Figure 2: Rear Panel of the GTP-805A
- 4 -
Figure 3: GTP-805A Installation
- 6 -
- 8 -
1000
1000BASE-SX/LX Fiber-optic
PoE
1000BASE-T UTP with PoE
6. Duplex Mode Support
Taiwan
May 29, 2018
Country
Date
Legal Signature
8. Cable Connection Parameter
The GTP-805A TP port supports triple speed -­10/100/1000BASE-T auto-negotiation. It will auto detect the link speed and the duplex mode by default with its link partner. The ber port (100/1000BASE-FX/SX/LX) allows 100/1000Mbps full duplex by auto-negotiation. Please also check the setting of the link partner as well.
7. LED Indication
System
LED Color Description
PWR Green Lit indicates the device is powered.
The wiring details are shown below:
Duplex Connection Limitation (max.)
Twisted Pair
Half/Full
Node to Node Node to Switch/Hub
100 meters
Fiber Optic Cables:
Standard (Wavelength)
Fiber Type & Cable Specications
100BASE-FX (1310nm)
1000BASE-SX (850nm)
1000BASE-LX (1310nm)
Multi-mode 50/125μm or 62.5/125μm
Single-mode 9/125μm
9.ProductSpecications
Model GTP-805A
Interface
10/100/1000BASE-T Ethernet TP
Copper Port
SFP Interface 100/1000BASE-X SFP interface
Fiber Mode May vary on SFP Module
interface
Auto-negotiation, auto MDI/MDI-X
with PoE injector function
- 9 -
10/100/1000BASE-T Port
LED Color Function
Indicating that the PoE+ Media
Blink
Converter is actively sending or receiving data over that port.
LNK/
PoE in
ACT
Use
Green
Orange
Indicating that the port is linked up
Light
at 10/100/1000Mbps.
Indicating that the port is linked
O
down.
Indicating that the port is providing
Light
PoE power to remote powered device.
Indicating that the port is not
O
providing PoE power to remote powered device.
100/1000BASE-X Fiber Port
LED Color Function
Indicating that the PoE+ Media
Blink
Converter is actively sending or
LNK/
ACT
Green
receiving data over that port.
Light Indicating that the port is linked up.
Indicating that the port is linked
O
down.
- 10 -
- 11 -
Fiber Port Type (connector)
Fiber Maximum Distance
SFP, LC type
May vary on SFP Module
Power Over Ethernet
IEEE 802.3af Power over Ethernet
PoE Output
PSE IEEE 802.3at Power over Ethernet Plus PSE
Power Output PoE 52~56V DC, 30 watts
PoE Power Supply Type end-span
Power Pin Assignment 1/2 (+), 3/6 (-)
PoE Power Budget 30 watts
Hardware Specications
Switch Architecture Store-and-Forward
Back pressure for half duplex mode
Flow Control
IEEE 802.3x pause frame for full duplex mode
Maximum Frame Size 9K
System: PWR
LED
Fiber 100/1000BASE-X: LNK/ACT TP 10/100/1000BASE-T: LNK/ACT PoE: Power-in-use
x D x
Dimensions (W
H) 70 x 97 x 26 mm
Weight 0.21kg
Power Supply
52~56V DC, external AC-to-DC adapter
- 12 - - 13 -
Enable: Shut down either TP port or
ber port that is broken
LFP Mode
Disable: Link LED indicators still on if
connection of the other end is broken
Installation Wall-mount or DIN-rail installation
Standards Conformance
Regulatory Compliance FCC Part 15 Class A, CE
IEEE 802.3 Ethernet IEEE 802.3u 100BASE-TX/100BASE­FX
IEEE 802.3ab Gigabit Ethernet Protocols and Standards Compliance
IEEE 802.3z Gigabit Ethernet over
Fiber Optic
IEEE 802.3x Flow Control
IEEE 802.3af Power over Ethernet
IEEE 802.3at Power over Ethernet
enhancements standard
TP: Cat 5/5e/6 UTP cable
Fiber: Multi-mode: 50/125μm or Cables
62.5/125μm optic ber
Single-mode: 9/125μm optic
ber
Environment
Temperature 0~50 degrees C
Humidity 5~90% (non-condensing)
1. For connection to the Gigabit Ethernet products, please refer to the device’s technical manual.
Note
2. Consult your dealer for DIN-rail installation.
EC Declaration of Conformity
I hereby confirm that the following equipment complies with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive on (2014/30/EU).
Type of Product:
100/1000BASE-X to 10/100/1000BASE-T PoE+ Media Converter
Model:
GTP-805A
Produced by:
Manufacturer’s Name: Planet Technology Corporation
Manufacturer’s Address: 10F., No.96, Minquan Rd., Xindian Dist.,
For the evaluation regarding the EMC, the following standards were applied:
EN 55032 (2015 + AC:2016)
EN61000-3-2 (2014)
EN61000-3-3 (2013)
EN 55024 (2010 + A1:2015)
EN 55035 (2017)
Person responsible for making this declaration
Name: Kent Kang
Title: Director
10F., No.96, Minquan Rd., Xindian Dist., New Taipei City, Taiwan, R.O.C. Tel:886-2-2219-9518 Fax:886-2-2219-9528
New Taipei City 231,Ta iwan , R.O.C.
PLANET TECHNOLOGY CORPORATION
e-mail: sales@planet.com.tw http://www.planet.com.tw
Loading...