Copyright PLANET Technology Corp. 2001. Contents subject
to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
FCC Warning
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
Instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may cause
radio interference, in which case the user may be required to take adequate
measures.
Revision
PLANET NOVASwitch User's Manual
FOR MODELS:
GSW-400S
Part No.: EM-GSW4SV1
Before Starting
In this User's Manual, "Switch" is used for GSW-400S, “NovaSwitch”
for PLANET’ s 19”-range Ethernet Switch, where “switch” represent the
third part switch.
Check the contents of your package for following parts:
w 4 port Switch
w User's manual
w Power cord
w 19" rack mount brackets
w RS-232 cable
If any of these pieces are missing or damaged, please contact your dealer
immediately, if possible, retain the carton including the original packing
material, and use them against to repack the product in case there is a need to
return it to us for repair.
About the Switch
The Switch, GSW-400S is designed to allow simultaneous transmission of
multiple packets via an internal high-speed data channel. This means that it
can partition a network more efficiently than bridges or routers in most
environments.
The Switch is equipped with Category 5 copper cable for uplinking to a
network backbone or network server. It is compatible with all 10Mbps,
100Mbps and 1000Mbps Ethernet environments. The increased speed and
extra bandwidth offered by Gigabit Ethernet will support faster and more
users applications with generating more traffic.
The Switch is designed for Plug and Play installation, allows the network
Page 6
administrator to simply connect the network and power cables and the
Switching/bridging functions begin automatically.
The front panel of these Switches provides LEDs for easy recognition of the
switch operation status and for troubleshooting. These LEDs display the
power status for the system and link/ speed/ collision, full-duplex, transmit
and receive status for each port.
The built-in console interface can be used to configure the Switch’s setting for
Priority queuing, VLAN, and Port Trunk Groups, Port Monitoring and Port
Speed.
Features:
w Complies with the IEEE802.3, IEEE802.3u, IEEE802.3z and
IEEE802.3ab Gigabit Ethernet standard, and IEEE802.1p Priority Queues
w Features Store-and-Forward mode with wire-speed filtering and
forwarding rates
w 10/100/1000Mbps capability on each port, total bandwidth is up to
2Gbps/port
w Automatic source address learning and aging.
w Support up to 32K MAC address
w Support up to total 64Mbit (8Mbyte) buffers with dynamic allocation.
w IEEE802.3x compliant full-duplex flow control
w Broadcast storm control, runt and CRC Filtering eliminates erroneous
packets to optimize the network bandwidth
w LED indicators for simple diagnostics and management
w Provide a reset switch in front panel
w Internal power supply
2
Ethernet Smart Switch
Page 7
w Auto MDI/ MDI-X on each ports
w Optional for Smart function
- Support one console port for switch configuration change
- Support per port Port-based VLAN and L2 Trunking with link fail-
over
- Support IEEE802.1p four Priority queues on each port
Specifications:
w Standard: IEEE802.3, IEEE802.3u, IEEE802.3ab, IEEE802.3x
w Network Media:
- 10Base-T, UTP/ STP category 3 ~ 5 cable
- 100Base-TX, UTP/ STP category 5 cable
- 1000Base-TX, UTP/ STP category 5 cable, 4 pairs
w Connector: STP RJ-45 port TX for 10/100/1000Mbps TX
w LED indicators:
- System – Power OK, Smart LED
- Individual port – Link 1000, Link 100, Link 10, FDX/COL, TX, RX
w Dimension: 433mm(L) x 200mm(W) x 44mm(H)
w Temperature: Operating – 0¢J to 50¢J Storage – -20¢J to 70¢J
w Humidity: Operating – 10% to 90% RH Storage – 5% to 90% RH
w Input Power Requirement: 100 - 240VAC, 50 – 60Hz, Auto-sensing
w Registrations: FCC Part 15 Class A, CE
GSW-400S User's Manual
3
Page 8
This page is intentionally left blank.
4
Ethernet Smart Switch
Page 9
Chapter 2
Hardware Description
This section describes the hardware features of these Switches. For easier
management and control of the switch, familiarize yourself with its display
indicators, and ports. Front panel illustrations in this chapter display the unit
LED indicators. Before connecting any network device to the hub, read this
chapter carefully.
Front Panel
The unit front panel provides a simple interface monitoring the switching hub.
It includes a power indicator for each port.
Figure 1. Front Panel of 4 copper ports Switch
LED indicators
ColorDescription
PWRGreenLit: Power on
SMARTGreenLit: CPU installed
LNK
10/100/1000
TX/ RXGreenLit: indicate data traffic status
FDX/ COLGreenLit: Full-Duplex
Reset Switch
At the left side of front panel, the reset switch is designed for reconfiguring the
GreenLit: indicate link status and traffic speed
(10 for 10M, 100 for 100M, 1000 for 1000M)
(TX for transmitting, RX for receiving)
Flash: Half-Duplex/ Collision
Off: Half-duplex or not connected
Page 10
switch hub without turn off and on the power.
Rear Panel
The rear panel of the Switch indicates an AC inlet power socket, which accepts
input power from 100 to 240VAC, 50-60Hz. And a RS-232 console port for
setting up the switch via a connection to a console terminal or PC using a
terminal emulation program.
Figure 2. Rear Panel of 4 copper ports Switch
Power Notice:
1. The device is a power-required device, it means, it will not work till it is
powered. If your networks should active all the time, please consider use an
UPS (Uninterrupted Power Supply) for your device. It will prevent you from
network data loss or network downtime.
2. In some area, installing a surge suppression device may also help to protect
your hub from being damaged by unregulated surge or current to the Switch
or the power adapter.
Hardware Installation
Connecting End node or Hub or Switch
1. Place the Switch on a smooth surface or fasten the mounting brackets with
6
Ethernet Smart Switch
Page 11
the provided screws in a standard 19” rack
2. Connect the DC jack of AC adapter to the DC inlet socket of Switch and the
other end into the local power source outlet
3. Connect hub or PC to one port of the Switch using Category 3/4/5 UTP/STP
cabling
4. Connect another hub or PC to the other port of Switch by following the
same process as described in Step3.
Figure 3. End node or Hub or Switch connection
Notice:
Cable distance for Switch
The cable distance between Ethernet Switch and hub/PC should
not exceed 100 meter.
Make sure the wiring is correct
It can be used Category 3/4/5 cable in 10 Mbps operation. To
reliably operate your network at 100Mbps and 1000Mbps, you
must use an Unshielded Twisted-Pair (UTP) Category 5 cable,
or better Data Grade cabling. While a Category 3 or 4 cable
may initially seem to work, it will soon cause data loss.
GSW-400S User's Manual
7
Page 12
Connecting to Network Backbone or Server
Figure 4. Network Backbone or Server connection
Connect to the Gigabit Ethernet ports with Category 5 copper cable for
uplinking to a network backbone or network server. These ports operate at
1000Mbps in full-duplex mode. A valid connection is indicated when the Link
LED is light.
The following sections describe the function of LEDs on the front panel
CPU LED
Color: Green
Label: Smart
Function: The LED light up steadily means CPU installed for smart
function
Power LED
Color: Green
8
Ethernet Smart Switch
Page 13
Label: PWR
Function: The LED light up steadily means Power turned on.
Link/ Speed LED
Color: Green
Label: 10/ 100/ 1000
Function: The LED light up steadily to indicate the transmitting speed
10: light up steadily to indicate link up at speed 10M
100: light up steadily to indicate link up at speed 100M
1000: light up steadily to indicate link up speed 1G
Full/ Half Duplex and Collision LED
Color: Green
Label: FDX/ COL
Function: The indicator LED flash up whenever there is a collision
between a directly attached end node and any other node, and
light up steadily for Full-duplex mode.
TX Activity
Color: Green
Label: LINK/ ACT
Function: Each RJ45 station port on the hub is assigned one LED for
transmitting the data.
RX Activity
Color: Green
Label: LINK/ ACT
Function: Each RJ45 station port on the hub is assigned one LED for
GSW-400S User's Manual
9
Page 14
receiving the data.
10
Ethernet Smart Switch
Page 15
Chapter 3
Configuration
Connect to PC
RS-232 serial cable
Prepare a RS-232 serial cable. Attach the 9-pin female connector to the male
connector on the switch. Plug the other side of this cable to your PC.
Hyper Terminal
In Windows 95/98, launch “HyperTerminal”, create a new connection, and
adjust settings as below:
Page 16
Main Menu
System Initial ,Please Wait...
Launch the new terminal you just set up, and then, turn on the switch.
See the following messages for successful connection.
device : [0] --> 0
device : [1] --> 1
device : [2] --> 2
PLANET GSW-400S Gigabit Ethernet Smart Switch
Menu Configuration [F/W:2.39]
[0] Port Setting
[1] Aging Control
[2] VLAN
[3] Queues Priority
[4] Trunk
[5] Uplink Port
[6] Monitor Port
[7] View Configuration
[8] Restore To Factory Default
Select :>>
To enter any of the submenus, simply type the number on the command line.
Speed Mode
Entry:
Select “0” from Main Menu.
Purpose:
Media Speed Control for each port.
Default:
All ports are auto- negotiation.
12
Ethernet Smart Switch
Page 17
1.Input port number for which you want to configure, ’A’ or ‘a’ for select all
which port ? (1 - 4 , E:Exit , A:Select all ports)...
port to configure, type ‘E’ or ‘e’ back to Main Menu, than press ENTER.
For example, input port 1:
1
Port Setting
[1] Auto-negotiation
[2] 10 Half Duplex
[3] 10 Full Duplex
[4] 100 Half Duplex
[5] 100 Full Duplex
Select :>>
2. Type 1-5 to select speed mode.
Select :>> 1
Enable flow control ? (Y/N)
3. Type ‘Y’, ’y’ or 'N', ’n’ to enable or disable flow control. After finish flow
control selection, you can configure another port or type ‘E’ or ‘e’, press
ENTER back to main menu.
y
Please Wait !!
Speed/Duplex Setting
which port ? (1 - 4 , E:Exit , A:Select all ports)...
e
GSW-400S User's Manual
13
Page 18
Address Learn
Select :>> 1
Select :>> e
Entry:
Select “1” from Main Menu.
Purpose:
A port’s MAC address register is cleared on power-up, or hardware reset.
If this item is enabled, the dynamically learned SA will be leared if it is
not refreshed in less than the aging time.
Default:
Enable with aging time 5 minutes.
Aging Control
[E] Enable
[D] Disable
Select :>>
Example: Enable aging control with aging time 2 minutes.
1. Type ‘E’ or 'e’ to enable aging control
Max address-aging timer
Max aging time (1 – 20 minute)...
2. Input ‘2’ for aging time and back to main menu
14
Ethernet Smart Switch
Page 19
VLAN
Select :>> 2
Select :>>
Entry:
Select “2” from Main Menu.
Purpose:
Each port of the switch can be assigned to one or multiple VLANs (this
device can be divided into 4 VLANs maximum). Frames from the source
port will only be forwarded to destination ports within the same VLAN
domain. A broadcast/multicast frame will be forwarded to all ports
within the VLAN(s) of the source port except the source port itself. An
unicast frame will be forwarded to the destination port only if the
destination port is in the same VLAN as the source port. If the
destination port belongs to another VLAN, the frame will be discarded.
Each port should be assigned with a dedicated uplink port. Unicast
frames with unknown destination addresses will be forwarded to the
uplink port of the source port. An uplink port can either be a single port
or a trunk.
Default:
All ports assigned to one VLAN.
VLAN
VLAN Group 1 ,assigned ports>>
[S] Port Select
[D] Port Delete
[A] Select All Ports
[C] Setting
[E] Exit
GSW-400S User's Manual
15
Page 20
Examples: Suppose the Switch assigned port 1,2 to VLAN group 1. port 3,4
Select :>> s
Select :>> s
belong to VLAN group 2, please follow below steps:
1. Type ‘S’ or ‘s’ than input '1', press ENTER
Which Port To be Selected (1 - 4)...
1
VLAN
VLAN Group 1 ,assigned ports>> 1
[S] Port Select
[D] Port Delete
[A] Select All Ports
[C] Setting
[E] Exit
Select :>>
2. Type ‘S’ or ‘s’ than input ‘2’ ,press ENTER
Which Port To be Selected (1 - 4)...
2
VLAN
VLAN Group 1 ,assigned ports>> 1 2
[S] Port Select
[D] Port Delete
[A] Select All Ports
[C] Setting
[E] Exit
Select :>>
3. Type ‘C’ or ‘c’ , than you can see “Group 1 >> 1 2” on the screen, that
16
Ethernet Smart Switch
Page 21
means VLAN group 1 with port 1,2 completed
Select :>> c
VLAN
Please Wait !!
VLAN
Group 1 >> 1 2
VLAN Group 2 ,assigned ports>>
[S] Port Select
[D] Port Delete
[A] Select All Ports
[C] Setting
[E] Exit
Select :>>
4. Repeat step 1 through 3 but input ‘3’ and ‘4’ to assigned [port 3 ,4 ] to next
VLAN group, than you can see the result below
Group 1 >> 1 2
Group 2 >> 3 4
VLAN Group 3 ,assigned ports>>
[S] Port Select
[D] Port Delete
[A] Select All Ports
[C] Setting
[E] Exit
Select: >>
5. Type ‘E’ or ‘e’ will assigned others to VALN group 3 and back to main
menu.
6. Assigned with a dedicated uplink port for each VLANs, please refer to
section of “Uplink Port”
GSW-400S User's Manual
17
Page 22
Queues Priority
Entry:
Select “3” from Main Menu.
Purpose:
The switch can support priority either from tagged frame or based on the
input ports. This entry is for port-based priority, level 0 stand for the
lowest priority, level 7 as highest priority. Flow control will be disable if
priority level 7 was selected.
Default:
All ports are cleared to priority zero on power-up, or hardware reset.
Select :>> 3
which port ? (1 - 4 , E:Exit )...
Example: Set port 1 to priority level 7.
1. Input ‘1’ for select port
1
Priority level ? (0 - 7 , E:Exit )...
2. Input ‘7’ priority level
7
which port ? (1 - 4 , E:Exit )...
3. Type ‘E’ or ‘e’ back to main menu
18
Ethernet Smart Switch
Page 23
Trunk
Select :>> 4
Entry:
Select “4” from Main Menu.
Purpose:
This switch can assigned port 1– 2 to trunk 0, port 3 – 4 to trunk 1, with
L2 Trunking automatically load-balances among its member ports
through the use of unique and statistical methods, and provides link
resiliency (link-fail-over function) when one or more of the link in a
trunk group fails.
The uplink port provides a way to connect the switch with a repeater hub,
a workgroup switch, a router, or any type of interconnecting device
compliance with IEEE 802.3 standards. Switch will send all frames with
unmatched DA and multicast/broadcast frames to the uplink port. It is
very important that each port is assigned to an uplink port, or data frames
might be lost. The uplink port should be configured to be within the
same VLAN as the source port. If the uplink port is not a member of the
VLAN, the broadcast or multicast frames will not be forwarded to its
designated uplink port. Multiple VLANs can share the same uplink port.
Default:
Disable
Uplink Port
UpLink Group 1 ,assigned ports>>
[S] Port Select
[D] Port Delete
[A] Select All Ports
[C] Continue
[E] Exit
Select :>>
GSW-400S User's Manual
21
Page 26
Example: assume already configure a VLAN, this VLAN have port 1, 2.
Select :>> s
1
Select :>>
1. Type ‘S’ or ‘s’ to select port
Which Port To be Selected (1 - 4)...
2. Input ‘1’ and press ENTER
Uplink Port
UpLink Group 1 ,assigned ports>> 1
[S] Port Select
[D] Port Delete
[A] Select All Ports
[C] Continue
[E] Exit
3. Repeat step 1,2 to select port 2 ,then see the result below.
UpLink Group 1 ,assigned ports>> 1 2
[S] Port Select
[D] Port Delete
[A] Select All Ports
[C] Continue
[E] Exit
Select :>>
4. Type ‘C’ or ‘c’ to continue
22
Ethernet Smart Switch
Page 27
Select :>> c
Select :>> e
Please Wait !!
Uplink Port Select
[A] port 1 [B] port 2 [C] port 3 [D] port 4
Select:>>
5. Type ‘I’ or ‘i’ to select uplink port ,as you can see bellow, “Group 1 >>
1 2 --> uplink to port 2” means port 1,2, ,have uplink to port 2.
Uplink Port
Group 1 >> 1 2 --> uplink to port 2
UpLink Group 2 ,assigned ports>>
[S] Port Select
[D] Port Delete
[A] Select All Ports
[C] Continue
[E] Exit
Select :>>
Monitor Port
Entry:
Select “6” from Main Menu.
Purpose:
The switch supports port monitoring. This feature provides complete
network monitoring capability at 100 Mbit/s. A copy of egress (TX) data
and ingress (RX) data of the monitored port is sent to their respective
GSW-400S User's Manual
23
Page 28
snooping ports.
Select :>> 6
Select :>> m
Default:
Disable
Monitor Port
[M] Monitored Port
[I] Monitoring Port for Incoming Packets
[O] Monitoring Port for Outgoing Packets
[D] Disable Port Monitor
[E] Exit
Select :>>
Example: Monitored Port 1 , Monitoring for incoming packets port 2,
Monitoring for outgoing packets port 3.
1. Type ‘M’ or ‘m’ to select Monitored Port
Which port to be monitored (1 - 4)...
2. Input ‘1’ and press ENTER
3. Repeat step1 –2 for monitoring port incoming packets and outgoing
packets.
4. Type ‘E’ or ‘e’ back to main menu.
24
Ethernet Smart Switch
Page 29
View Configuration
Select :>> 7
Entry:
Select “7” from Main Menu.
Purpose:
Display configuration of trunk , uplink and VLAN.
[Current TRUNK]
Disable
[Current UpLink]
Disable
[Current VLAN]
Group 1 >> 1 2 3 4
press any key to continue ...
Restore To Factory Default
Entry:
Select “8” from Main Menu.
Purpose:
Restore to the default setting as mention before.
GSW-400S User's Manual
25
Page 30
This page is intentionally left blank.
26
Ethernet Smart Switch
Page 31
Chapter 4
Switch Operation
Address Table
The Switch is implemented with an address table. This address table composed
of many entries. Each entry is used to store the address information of some
node in network, including MAC address, port no, etc. This information comes
from the learning process of Ethernet Switch..
Learning
When one packet comes in from any port. The Switch will record the source
address, port no. and the other related information in address table. This
information will be used to decide either forwarding or filtering for future
packets.
Forwarding & Filtering
When one packet comes from some port of the Ethernet Switching, it will also
check the destination address besides the source address learning. The Ethernet
Switching will lookup the address-table for the destination address. If not found,
this packet will be forwarded to all the other ports except the port which this
packet comes in. And these ports will transmit this packet to the network it
connected. If found, and the destination address is located at different port from
this packet comes in, the Ethernet Switching will forward this packet to the port
where this destination address is located according to the information from
address table. But, if the destination address is located at the same port with this
packet comes in, then this packet will be filtered. Thereby increasing the
Page 32
network throughput and availability
Store-and-Forward
Store-and-Forward is one type of packet-forwarding techniques. A Store-and
Forward Ethernet Switching stores the incoming frame in an internal buffer, do
the complete error checking before transmission. Therefore, no error packets
occurrence, it is the best choice when a network needs efficiency and stability.
The Ethernet Switch scans the destination address from the packet-header,
searches the routing table provided for the incoming port and forwards the
packet, only if required. The fast forwarding makes the switch attractive for
connecting servers directly to the network, thereby increasing throughput and
availability. However, the switch is most commonly used to segment existing
hubs, which nearly always improves overall performance. An Ethernet
Switching can be easily configured in any Ethernet network environment to
significantly boost bandwidth using conventional cabling and adapters.
Due to the learning function of the Ethernet switching, the source address and
corresponding port number of each incoming and outgoing packet are stored in
a routing table. This information is subsequently used to filter packets whose
destination address is on the same segment as the source address. This confines
network traffic to its respective domain, reducing the overall load on the
network.
The Switch performs "Store and forward" therefore, no error packets occur.
More reliably, it reduces the re-transmission rate. No packet loss will occur.
28
Ethernet Smart Switch
Page 33
Auto-Negotiation
The STP ports on the Switch have built-in “Auto-negotiation”. This technology
automatically sets the best possible bandwidth when a connection is established
with another network device (usually at Power On or Reset). This is done by
detect the modes and speeds at the second of both device is connected and
capable of, Both 10Base-T and 100Base-TX devices can connect with the port
in either Half- or Full-Duplex mode. 1000Base-TX and 1000Base-SX can only
connected Full-duplex mode.
GSW-400S User's Manual
29
Page 34
30
.
Page 35
Chapter 5
Troubleshooting
This chapter contains information to help you solve problems. If Switch is not
functioning properly, make sure the Ethernet Switch was set up according to
instructions in this manual..
The Link LED is not lit
Solution:
Check the cable connection and remove duplex mode of the Switch
Some stations can not talk to other stations located on the other
port
Solution:
The address table may contain older information than of the address table of
that node. Please power down to refresh the address information.
Page 36
This page is intentionally left blank.
32
Ethernet Smart Switch
Page 37
Chapter 6
Appendix A
Hub‘s RJ-45 Pin Assignments
1. 10/100Mbps-TX
PinStation Ports 1-8Uplink Port
1Input Receive Data +Output Transmit Data+
2Input Receive Data -Output Transmit Data3Output Transmit Data+ Input Receive Data +
6Output Transmit Data-Input Receive Data -
4,5,7,8Not usedNot used
Schematics for both straight and crossover twisted-pair cable are shown below.
(Note that crossover cable is only required if you cascade hubs via the RJ-45
station ports; i.e. the Uplink port is not used.)
Implicit implementation of the crossover function within a twisted-pair cable,
or at a wiring panel, while not expressly forbidden, is beyond the scope of this
standard.
34
Ethernet Smart Switch
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.