Contents subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp. All other trademarks
belong to their respective owners.
Disclaimer
PLANET Technology does not warrant that the hardware will work properly in all
environments and applications, and makes no warranty and representation, either
implied or expressed, with respect to the quality, performance, merchantability, or
tness for a particular purpose.
PLANET has made every effort to ensure that this User’s Manual is accurate;
PLANET disclaims liability for any inaccuracies or omissions that may have
occurred.
Information in this User’s Manual is subject to change without notice and does not
represent a commitment on the part of PLANET. PLANET assumes no responsibility
for any inaccuracies that may be contained in this User’s Manual. PLANET makes
no commitment to update or keep current the information in this User’s Manual,
and reserves the right to make improvements to this User’s Manual and/or to the
products described in this User’s Manual, at any time without notice.
If you nd information in this manual that is incorrect, misleading, or incomplete,
we would appreciate your comments and suggestions.
FCC Warning
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with
the Instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at
his own expense.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may cause radio
interference, in which case the user may be required to take adequate measures.
Energy Saving Note of the Device
This power required device does not support Standby mode operation.
For energy saving, please remove the power cable to disconnect the device from
the power circuit.
Without removing power cable, the device will still consuming power from the
power source. In the view of Saving the Energy and reduce the unnecessary power
consuming, it is strongly suggested to remove the power connection for the device
if this device is not intended to be active.
WEEE Warning
To avoid the potential effects on the environment and human health as a
result of the presence of hazardous substances in electrical and electronic
equipment, end users of electrical and electronic equipment should
understand the meaning of the crossed-out wheeled bin symbol. Do not
dispose of WEEE as unsorted municipal waste and have to collect such WEEE
separately.
Revision
PLANET 8-Port 10/100/1000Mbps with 4-Port PoE Gigabit Ethernet Switch User's
Manual For Model: GSD-804P
Check the contents of your package for following parts:
GSD-804P x 1
User's Manual x 1
Power Cord x 1
If any of these pieces are missing or damaged, please contact your dealer
immediately, if possible, retain the carton including the original packing material,
and use them against to repack the product in case there is a need to return it to
us for repair.
1.2 Product Description
To fulll the demand of sufcient PoE power for network applications with Gigabit
speed transmission, the new member in the 802.3af PoE Gigabit Ethernet Switch
family - GSD-804P, the 8-Port 10/100/1000Mbps with 4-Port 802.3af Power over
Ethernet Switch which features high performance Gigabit IEEE 802.3af PoE (Up to
15.4 Watts) and totally 55 Watts PoE budget on half of the 10/100/1000Mbps TP
ports of GSD-804P. The four 802.3af PoE ports provide PoE power injector function
which is able to drive 4 IEEE 802.3af compliant powered devices. The GSD-804P
also provides a simple, cost-effective, and non-blocking wire-speed performance
with 10-inch metal shape for desktop deployment in compact housing, SOHO ofce
or department network application.
All RJ-45 copper interfaces in the GSD-804P support 10/100/1000Mbps AutoNegotiation for optimal speed detection through RJ-45 Category 6, 5 or 5e cables.
It also supports standard Auto-MDI/MDI-X that can detect the type of connection
to any Ethernet device without requiring special straight or crossover cables.
1.3 Features
RJ-45 Interface
8-Port 10/100/1000Mbps Gigabit Ethernet ports l
4-Port supports 48V DC power to PoE Powered Device l
PoE
Complies with IEEE 802.3af Power over Ethernet End-Span PSE l
Up to 4 IEEE 802.3af devices powered l
6
Supports PoE Power up to 15.4 Watts for each PoE port l
Auto detect powered device (PD) l
Circuit protection prevents power interference between ports l
Remote power feeding up to 100m l
Switching
Hardware based 10/100/1000Mbps Auto-Negotiation and Auto MDI/MDI-X l
Flow control for Full Duplex operation and back pressure for Half Duplex oper- l
ation
Integrates address look-up engine, supporting 8K absolute MAC addresses l
9K Jumbo Frame supports at all speed (10/100/1000Mbps) l
Automatic address learning and address aging l
Hardware
10-inch desktop size, rack mountable; 1U height l
LED indicators for PoE ready and PoE activity l
Optional Rack Ear Accessories Kit for 10-inch cabinet (RKE-10A) and 19-inch l
cabinet (RKE-10B)
1 silent FAN to provide stable and efcient power performance l
Energy-Saving technology l
Link down power saving
Intelligent scales power based on cable length
7
1.4 Specication
ModelGSD-804P
Hardware Specication
Network Connector8-Port RJ-45 for 10/100/1000Base-T
PoE Inject Port
LED Display
Switch ArchitectureStore and Forward switch architecture
MAC Address8K MAC address table with Auto learning function
Switch Fabric16Gbps
Switch Throughput11.9Mpps
Jumbo Packet Size9K Bytes
Power RequirementAC 100~240V, 50/60Hz, 1.5A
Power ConsumptionMax. 65 Watts / 221 BTU
Dimension (W x D x H)217 x 135 x 43 mm
Weight890g
Power over Ethernet
PoE StandardIEEE 802.3af Power over Ethernet / PSE
PoE Power Supply TypeEnd-Span
PoE Power OutputPer Port 48V DC, 350mA . Max. 15.4 Watts
Ethernet
Fast Ethernet
Gigabit Ethernet
Flow Control
Power over Ethernet
8
2. Hardware Description
This product provides three different running speeds – 10Mbps, 100Mbps and
1000Mbps in the same switch and automatically distinguishes the speed of
incoming connection.
This section describes the hardware features of GSD-804P. For easier management
and control of the Switch, familiarize yourself with its display indicators, and ports.
Front panel illustrations in this chapter display the unit LED indicators. Before
connecting any network device to the GSD-804P, please read this chapter carefully.
In the following section, the term “Switch” means the Switch device, ie. GSD804P; term of “switch” can be any third switches.
2.1 Front Panel
The Front Panel of the GSD-804P PoE Ethernet Switch consists of 8x Auto-Sensing
10/100/1000Mbps Ethernet RJ-45 Ports. The LED Indicators are also located on the
front panel of the GSD-804P.
Figure 2-1: GSD-804P Switch Front Panel
9
2.1.1 LED Indicators
Power
Notice
System
LEDColorFunction
PWRGreenLights to indicate that the Switch has power.
FAN AlertOrangeLights to indicate that the FAN failure.
Per 10/100/1000Mbps Port
LEDColorFunction
PoE In-useOrange
SpeedGreen
LNK/ACTGreen
Lights to indicate the port is providing 48V DC in-line
power. (1-4 ports)
Lit: indicate the Switch is successfully connecting to the
network at 1000Mbps.
Off: indicate that the Switch is successfully connecting
to the network at 10Mbps or 100Mbps.
Lit: indicate the link through that port is successfully
established.
Blinks to indicate that the Switch is actively sending or
receiving data over that port.
2.2 Rear Panel
The rear panel of the GSD-804P indicates an AC inlet power socket, which accepts
input power from 100 to 240VAC, 50-60Hz. And have a fan hole on the rear panel.
Figure 2-2: GSD-804P Switch Rear Panel
1. The device is a power-required device, it means, it will not work
till it is powered. If your networks should active all the time,
please consider using UPS (Uninterrupted Power Supply) for your
device. It will prevent you from network data loss or network
downtime.
2. In some area, installing a surge suppression device may also
help to protect your GSD-804P from being damaged by unregulated surge or current to the GSD-804P or the power adapter.
10
3. Hardware Installation
Before start up
Before your installation, please refer to the followings for your cabling:
10/100/1000Base-T
All 10/100/1000Base-T ports come with Auto-Negotiation capability. They
automatically support 1000Base-T, 100Base-TX and 10Base-T networks. Users
only need to plug a working network device into one of the 10/100/1000Base-T
ports, and then turn on the GSD-804P. The port will automatically runs in 10Mbps,
20Mbps, 100Mbps or 200Mbps and 1000Mbps or 2000Mbps after the negotiation
with the connected device.
Cabling
Each 10/100/1000Base-T ports use RJ-45 sockets - similar to phone jacks - for
connection of unshielded twisted-pair cable (UTP). The IEEE 802.3 / 802.3u
802.3ab Fast / Gigabit Ethernet standard requires Category 5 UTP for 100Mbps
100Base-TX. 10Base-T networks can use Cat.3, 4, 5 or 1000Base-T use 5/5e/6 UTP
(see table below). Maximum distance is 100meters (328 feet).
Port TypeCable TypeConnector
10Base-TCat 3, 4, 5, 2-pairRJ-45
100Base-TXCat.5 UTP, 2-pairRJ-45
1000Base-TCat.5/5e/6 UTP, 2-pairRJ-45
Any Ethernet devices like hubs/ PCs can connect to the GSD-804P by using
straight-through wires. The eight-10/100/1000Mbps ports are auto-MDI/MDI-X can
be used on straight-through or crossover cable.
11
3.1 Desktop Installation
Note
Note
To install the Switch on desktop, simply follow the next steps:
Step 1: Place the Switch on desktop near an AC power source.
Step 2: Keep enough ventilation space between the Switch and the surrounding
objects.
When choosing a location, please keep in mind the environmental
restrictions discussed in Chapter 1, Section 4, in Specification.
Step 3: Connect your Switch to 802.3af complied Power Devices (PD) and other
network devices.
A. Connect one end of a standard network cable to the 10/100/1000
RJ-45 ports on the front of the Switch.
B. Connect the other end of the cable to the network devices such as
printer servers, workstations or routers…etc.
Connection to the Switch requires UTP Category 5 network cabling
with RJ-45 tips. For more information, please see the Cabling Specification in Appendix A.
Step 4: Supply power to the Switch.
A. Connect one end of the power cable to the Switch.
B. Connect the power plug of the power cable to a standard wall outlet.
When the Switch receives power, the Power LED should remain solid Green.
12
3.2 Rack Mounting
GSD-804P
8-Port 10/100/1000Mbps
Gigabit
Ethernet
Switch with 4-Port Injector
8-Port 10/100/1000Mbps
Gigabit
Ethernet
Switch with 4-Port Injector
To install the Switch in a 10-inch standard rack, follow the instructions described
below.
Step 1: Place your Gigabit Ethernet Switch on a hard at surface, with the front
panel positioned towards your front side.
Step 2: Attach a rack-mount bracket to each side of the Switch with supplied
screws attached to the package. Figure 3-1 shows how to attach brackets
to one side of the Switch.
Figure 3-1: Attaching the brackets to the Switch.
You must use the screws supplied with the mounting brackets.
Damage caused to the parts by using incorrect screws would invalidate the warranty.
Step 3: Secure the brackets tightly.
Step 4: Follow the same steps to attach the second bracket to the opposite side.
Step 5: After the brackets are attached to the Switch, use suitable screws to
securely attach the brackets to the rack, as shown in Figure 3-2.
Figure 3-2: Mounting the Switch in a Rack
Step 6: Proceeds with the steps 3 and steps 4 of session 3.1 Desktop
Installation to connect the network cabling and supply power to your
Switch.
13
3.3 Product Application
LAN / PCs
802.3af PoE
IP Camera
802.3af PoE
VoIP Phone
N
N
PoEPoEPoEPoE
Powe r
AC
Power Line (AC)
AC
1000Base-T UTP
PoE
1000Base-T UTP with PoE
2.4GHz 802.11n
N
GSD-804P
802.3af PoE
VoIP Phone
802.3af PoE
Wireless AP
10/100/1000Base-T Data
Note
3.3.1 Connecting end node or Switch
1. Place the GSD-804P on a smooth surface or fasten the mounting brackets
purchased separately with the provided screws in a standard 19” rack.
2. Connect the power cord to the power inlet socket of GSD-804P and the other
end into the local power source outlet. When the Switch receives power, the
Power LED should remain solid Green.
3. Connect other switch or PC to one port of the GSD-804P using Category
3/4/5/5e/6 UTP/STP cabling.
4. Connect another switch or PC to the other port of GSD-804P by following the
same process as described in Step 3.
Figure 3-3: End node or Switch Connection
Cable distance for Switch
The cable distance between the GSD-804P and PC should not
exceed 100 meter for UTP/STP cable.
Make sure the wiring is correct
It can be used Category 3/4/5 cable in 10Mbps operation. To reliably operate your network at 100Mbps or 1000Mbps, you must use
an Unshielded Twisted-Pair (UTP) Category 5/5e/6 cable, or better
Data Grade cabling. While a Category 3 or 4 cables may initially
seem to work, it will soon cause data loss.
14
3.3.2 Department/ Workgroup PoE Switch
GSD-804P
802.3af PoE
IP Camera
802.3af PoE
VoIP ATA
802.3af PoE VoIP Phone
LAN / PCs
10/100/1000Base-T Data
Data
Powe r
Data+Power
Data+Power
802.3af PoE Wireless AP
NN
PoEPoE
PoE
PoE
AC
Power Line (AC)
AC
1000Base-T UTP
PoE
1000Base-T UTP with PoE
2.4GHz 802.11n
N
Providing 4-Port PoE in-line power interface, the GSD-804P can easily build a power
centrally-controlled IP phone system, IP Camera system and Wireless AP group for
the enterprise. For instance, up to 4 cameras can be installed around the corner in
the company for surveillance demands or up to 4 Wireless AP to build a wireless
roaming environment in the ofce. Without the power-socket limitation, the Switch
makes the installation of cameras or Wireless AP more easily and efciently.
Figure 3-4: Department / workgroup PoE Switch Connection
15
3.4 Power over Ethernet Powered Device
Voice over IP phones
Enterprise can install POE VoIP Phone, ATA and other
Ethernet/non-Ethernet end-devices to the central where
UPS is installed for un-interrupt power system and power
3~5 Watts
6~12 Watts
10~12 Watts
control system.
Wireless LAN Access Points
Museum, Sightseeing, Airport, Hotel, Campus, Factory,
Warehouse can install the Access Point any where with
no hesitation.
IP Surveillance
Enterprise, Museum, Campus, Hospital, Bank, can install
IP Camera without limits of install location – no need
electrician to install AC sockets.
3~12 Watts
3~25 Watts
PoE Splitter
PoE Splitter split the PoE 52V DC over the Ethernet
cable into 5/12V DC power output. It frees the device
deployment from restrictions due to power outlet
locations, which eliminate the costs for additional AC
wiring and reduces the installation time.
High Power PoE Splitter
High PoE Splitter split the PoE 52V DC over the Ethernet
cable into 5/12V DC power output. It frees the device
deployment from restrictions due to power outlet
locations, which eliminate the costs for additional AC
wiring and reduces the installation time.
16
4. Power over Ethernet Overview
What is PoE?
Based on the global standard IEEE 802.3af, PoE is a technology for wired Ethernet,
the most widely installed local area network technology adopted today. PoE allows
the electrical power necessary for the operation of each end-device to be carried
by data cables rather than by separate power cords. New network applications,
such as IP Cameras, VoIP Phones, and Wireless Networking, can help enterprises
improve productivity. It minimizes wires that must be used to install the network
for offering lower cost, and less power failures.
IEEE 802.3af also called Data Terminal equipment (DTE) power via Media
dependent interface (MDI) is an international standard to dene the transmission
for power over Ethernet. The 802.3af is delivering 48V power over RJ-45 wiring.
Besides 802.3af also dene two types of source equipment: Mid-Span and End-
Span.
Mid-Span
Mid-Span device is placed between legacy switch and the powered device. Mid-
Span is tap the unused wire pairs 4/5 and 7/8 to carry power, the other four is
for data transmit.
End-Span
End-Span device is direct connecting with power device. End-Span could also tap
the wire 1/2 and 3/6.
PoE System Architecture
The specication of PoE typically requires two devices: the Powered Source
Equipment (PSE) and the Powered Device (PD). The PSE is either an End-Span
or a Mid-Span, while the PD is a PoE-enabled terminal, such as IP Phones, Wireless
LAN, etc. Power can be delivered over data pairs or spare pairs of standard CAT-5
cabling.
How Power is Transferred Through the Cable
A standard CAT5 Ethernet cable has four twisted pairs, but only two of these are
used for 10BASE-T and 100BASE-T. The specication allows two options for using
these cables for power, shown in Figure 2 and Figure 3:
The spare pairs are used. Figure 2 shows the pair on pins 4 and 5 connected
together and forming the positive supply, and the pair on pins 7 and 8 connected
and forming the negative supply. (In fact, a late change to the spec allows either
polarity to be used).
17
Figure 1 - Power Supplied over the Spare Pins
The data pairs are used. Since Ethernet pairs are transformer coupled at each
end, it is possible to apply DC power to the center tap of the isolation transformer
without upsetting the data transfer. In this mode of operation the pair on pins 3
and 6 and the pair on pins 1 and 2 can be of either polarity.
Figure 2 - Power Supplied over the Data Pins
18
When to install PoE?
Consider the following scenarios:
You’re planning to install the latest VoIP Phone system to minimize cabling l
building costs when your company moves into new ofces next month.
The company staff has been clamoring for a wireless access point in the picnic l
area behind the building so they can work on their laptops through lunch, but
the cost of electrical power to the outside is not affordable.
Management asks for IP Surveillance Cameras and business access systems l
throughout the facility, but they would rather avoid another electrician’s
payment.
References:
IEEE Std 802.3af-2003 (Amendment to IEEE Std 802.3-2002, including IEEE Std
802.3ae-2002), 2003 Page(s):0_1-121
White Paper on Power over Ethernet (IEEE 802.3af)
http://www.poweroverethernet.com/articles.php?article_id=52
This chapter contains information to help you solve issues. If the Switch is not
functioning properly, make sure the Ethernet Switch was set up according to
instructions in this manual.
The Link LED is not lit
Solution:
Check the cable connection and remove duplex mode of the Switch.
Performance is bad
Solution:
Check the full duplex status of the Switch. If the Ethernet Switch is set to full
duplex and the partner is set to half duplex, then the performance will be poor.
100Base-TX port link LED is lit, but the trafc is irregular
Solution:
Check that the attached device is not set to dedicate full duplex. Some devices use
a physical or software switch to change duplex modes. Auto-negotiation may not
recognize this type of full-duplex setting.
Why the Switch doesn’t connect to the network
Solution:
Check the LNK/ACT LED on the Switch Try another port on the Switch Make sure
the cable is installed properly, Make sure the cable is the right type. Turn off the
power. After a while, turn on power again.
Why I connect my PoE device to GSD-804P and it cannot power on?
Solution:
1. Please check the cable type of the connection from GSD-804P(port 1 to port
4) to the other end. The cable should be an 8-wire UTP, Category 5 or above,
EIA568 cable within 100 meters. A cable with only 4-wire, short loop or over
100 meters, all will affect the power supply.
2. Please check and assure the device that fully complied with IEEE 802.3af standard.
What is the power output of each IEEE 802.af PoE port?
Solution:
Each PoE port supports 48V DC, 350mA, max 15.4 Watts power output. Detect
and inject by the standard of IEEE 802.3af.
20
Appendix A Networking Connection
1 2 3 4 5 6 7 8
A.1 Data Out PoE Switch RJ-45 Port Pin Assignments (Port 1 to
Implicit implementation of the crossover function within a twisted-pair cable, or at
a wiring panel, while not expressly forbidden, is beyond the scope of this standard.
When connecting your Switch to another Fast Ethernet switch, a bridge or a hub, a
straight or crossover cable is necessary. Each port of the Switch supports auto-MDI/
MDI-X detection. That means you can directly connect the Switch to any Ethernet
devices without making a crossover cable. The following table and diagram show
the standard RJ-45 receptacle/ connector and their pin assignments:
RJ-45 Connector pin assignment
Contact
1Tx + (transmit)Rx + (receive)
2Tx - (transmit)Rx - (receive)
3Rx + (receive)Tx + (transmit)
4, 5Not used
6Rx - (receive)Tx - (transmit)
7, 8Not used
The standard cable, RJ-45 pin assignment
Media Dependant Interface
MDI
Media Dependant Interface-Cross
MDI-X
The standard RJ-45 receptacle/connector
There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The
Straight Cable
Cross Over Cable
SIDE 1
SIDE 1
SIDE 2
SIDE 1
SIDE 2
12345678
12345678
12345678
12345678
SIDE 2
1 = White/Orange
2 = Orange
3 = White/Green
4 = Blue
5 = White/Blue
6 = Green
7 = White/Brown
8 = Brown
1 = White/Orange
2 = Orange
3 = White/Green
4 = Blue
5 = White/Blue
6 = Green
7 = White/Brown
8 = Brown
SIDE 1SIDE 2
1 = White/Orange
2 = Orange
3 = White/Green
4 = Blue
5 = White/Blue
6 = Green
7 = White/Brown
8 = Brown
1 = White/Green
2 = Green
3 = White/Orange
4 = Blue
5 = White/Blue
6 = Orange
7 = White/Brown
8 = Brown
following shows the pin allocation and color of straight cable and crossover cable
connection:
Figure A-1: Straight-Through and Crossover Cable
Please make sure your connected cables are with same pin assignment and color
as above picture before deploying the cables into your network.
22
EC Declaration of Conformity
For the following equipment:
*Type of Product: 8-Port 10/100/1000Mbps with 4-Port PoE Ethernet Switch
*Model Number: GSD-804P
* Produced by:
Manufacturer‘s Name :Planet Technology Corp.
Manufacturer‘s Address: 10F., No.96, Minquan Rd., Xindian Dist.,
New Taipei City 231, Taiwan (R.O.C.)
is herewith confirmed to comply with the requirements set out in the Council Directive on the
Approximation of the Laws of the Member States relating to Electromagnetic Compatibility
Directive on (2004/108/EC).
For the evaluation regarding the EMC, the following standards were applied: