PLANET makes no representations or warranties, either expressed or implied,
with respect to the contents hereof and specically disclaims any warranties,
merchantability or tness for any particular purpose. Any software described
in this manual is sold or licensed "as is". Should the programs prove defective
following their purchase, the buyer (and not PLANET, its distributor, or its dealer)
assumes the entire cost of all necessary servicing, repair, and any incidental or
consequential damages resulting from any defect in the software. Further, PLANET
reserves the right to revise this publication and to make changes from time to time
in the contents hereof without obligation to notify any person of such revision or
changes
All brand and product names mentioned in this manual are trademarks and/or
registered trademarks of their respective holders.
Trademarks
PLANET is a registered trademark of PLANET Technology Corp. All other trademarks
belong to their respective owners.
Disclaimer
PLANET Technology does not warrant that the hardware will work properly in all
environments and applications, and makes no warranty and representation, either
implied or expressed, with respect to the quality, performance, merchantability, or
tness for a particular purpose.
PLANET has made every eort to ensure that this User’s Manual is accurate;
PLANET disclaims liability for any inaccuracies or omissions that may have
occurred. Information in this User’s Manual is subject to change without notice
and does not represent a commitment on the part of PLANET. PLANET assumes
no responsibility for any inaccuracies that may be contained in this User’s Manual.
PLANET makes no commitment to update or keep current the information in this
User’s Manual, and reserves the right to make improvements to this User’s Manual
and/or to the products described in this User’s Manual, at any time without notice.
If you nd information in this manual that is incorrect, misleading, or incomplete,
we would appreciate your comments and suggestions.
Page 3
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with
the Instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at
his own expense.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may cause radio
interference, in which case the user may be required to take adequate measures.
WEEE Warning
To avoid the potential eects on the environment and human health as a
result of the presence of hazardous substances in electrical and electronic
equipment, end users of electrical and electronic equipment should
understand the meaning of the crossed-out wheeled bin symbol. Do not
dispose of WEEE as unsorted municipal waste; WEEE should be collected
Open the box of the 802.3at PoE+ Switch and carefully unpack it. The box should
contain the following items:
802.3at PoE+ Switch x 1User’s Manual x 1
Power Cord x 1Screws Package x 1
Rack-mounting Brackets x 2Rubber Feet x 4
5
Page 6
If any of these pieces are missing or damaged, please contact your dealer
immediately; if possible, retain the carton including the original packing material,
and use them again to repack the product in case there is a need to return it to us
for repair.
1.2 Product Description
Ideal High-performance Integration Solution for Secure IP Surveillance
Infrastructure
Particularly designed for the growing popular IP surveillance applications, PLANET
GSD/GSW 802.3at PoE+ Switch series is positioned as a surveillance switch with
the central power management and IP camera monitoring.
The GSD/GSW 802.3at PoE+ Switch series brings an ideal, secure surveillance
system at a lower total cost. The GSD/GSW 802.3at PoE+ Switch series provides
multiple 10/100/1000 Mbps 802.3at/af PoE ports able to supply sucient PoE
power to IEEE 802.3at PoE IP cameras at the same time. It is also able to be
connected with an 8-/16-/32-channel NVR system, uplinked to the backbone switch
and the monitoring center. With such a high-performance switch architecture, the
recorded video les from the PoE IP cameras can be saved in the NVR system to
enable the administrators to control and monitor the surveillance images both in
the local LAN and the remote sites.
ModelGSD-1222VHPGSW-1820VHPGSW-2620VHP
10/100/1000T Copper8 x RJ4516 x RJ4524 x RJ45
10/100/1000T Copper2 x RJ45----
1000X Fiber Optic2 x SFP Slots2 x SFP Slots2 x SFP Slots
802.3af/at PoE+ Ports81624
PoE Budget120 watts300 watts300 watts
Enclosure12” metal case19” metal case19” metal case
6
Page 7
Just “Plug and Watch” for a Quick Solution
The GSD/GSW 802.3at PoE+ Switch series is an ideal Plug and Watch Power over
Ethernet solution which provides quick installation, real-time PoE work status
monitoring and immediate troubleshooting through its unique LCD display to
improve work eciency and quality without any PC or software required.
The GSD/GSW 802.3at PoE+ Switch series is equipped with 8/16/24
10/100/1000BASE-T ports featuring 30-watt 802.3at Power over Ethernet Plus
(PoE+) copper interfaces. With a total PoE power budget of up to 300 watts and
non-blocking data switching performance, the GSD/GSW 802.3at PoE+ Switch
series fullls the demand of sucient PoE power for HD IP surveillance. It oers a
desktop-sized, reliable and visible power solution for small businesses and system
integrators deploying Power over Ethernet networks.
Smart LCDPower LED
Menu/Enter/Back
Up/Down Button
PoE & LNK/ACT
Status
Gigabit SFP
LNK/ACT Status
16 x 10/100/1000BASE-T 802.3at PoE+
2 x Gigabit SFP
7
Page 8
Smart and Intuitive LCD Control
4 6 82
1 3 5 7
12 14 1610
9 11 13 15
GSW-1820VHP
1
PWR
Up
Down
Menu (5 sec)
Enter
Back
5 9 13
3 7 11 15
PoE
2 6 10 14
4 8 12 16
PoE
PoE In-Use
ACTLNK1000
ACTLNK10/100
ACT
LNK
SFP
17 18
SFP
1718
16-Port 10/100/1000T 802.3at PoE
+
2-Port Gigabit SFP Ethernet Switch
Switch Port Information
30.3
01W
---M867
M
----
02W
---M---
M
----W03---M---
M
15.4W04-10M---
M
----W05---M---
M
----
06W
---M---
M
----
07W
---M---
M
----
08W
---M---
M
-8.3
09W
---M-<1
M
----
10W
---M---
M
-OFF
11-
---M---
M
----
12W
---M---
M
17.6W13223M246
M
----
14W
---M---
M
PB:300WTP:72WPD:0
Main Menu
01 —
02 —
03 —
05 —
06 —
07 —
08 —
Switch Mode
Budget Control
PSE Port Priority
PD Type
Alive Check
Bandwidth
Fan Control
04 —
PSE Port Enable
System
<Back>: Return
PLANET 802.3af/at PoE Switch
www.planet.com.tw
Model: FGSW-2622VHP
HW ver: V2.0
SW ver: V3.01
PSE Port Enable
PortStatus
>
Enable 01
Disable
<UP>/<Down>:Select
<Enter>:Confirm <Back>:Return
Current Setting: Enable
Switch Mode
Options:
VLAN
Extend
Standard>
The GSD/GSW 802.3at PoE+ Switch series provides an intuitive color panel on its
front panel that facilitates the Ethernet management and PoE PD management.
They greatly promote management eciency in large-scale network, such as
enterprises, hotels, shopping malls, government buildings, and other public areas,
and feature the following special management and status functions:
PoE management and status
Port management and status
Switch Mode: Standard, VLAN, Extend
Budget and bandwidth control
PD alive check
Maintenance: Screen saver, fan control, factory default and save conguration
8
Page 9
Standard, VLAN and Extend Operation Modes Oered
The GSD/GSW 802.3at PoE+ Switch series provides Standard, VLAN and Extend
operation modes. The GSD/GSW 802.3at PoE+ Switch series operates as a normal
IEEE 802.af/at PoE Switch in the Standard operation mode. The VLAN operation
mode features the port-based VLAN function that can help to prevent the IP
camera’s multicast or broadcast storm from inuencing each other.
VLAN Isolation Mode
Standard
> VLAN
Extend
NVR
Ports 17 and 18 for uplink
1000
Ports 1~16 Access Permitted
PoE
PoE
PoE
IP Camera
IP Camera
IP Camera
Ports 1 to 16
Access Denied
GSW-1820VHP
PC
1000
1000BASE-SX/LX Fiber-optic
1000BASE-T UTP
PoE
1000BASE-T UTP with PoE
In the Extend operation mode, the GSD/GSW 802.3at PoE+ Switch series operates
on a per-port basis at 10Mbps duplex operation but can support 20-watt PoE
power output over a distance of up to 250 meters overcoming the 100m limit on
Ethernet UTP cable. With this brand-new feature, the GSD/GSW Series provides
an additional solution for 802.3af/at PoE distance extension, thus saving the cost
of Ethernet cable installation. Its VLAN isolation function isolates ports so as to
prevent broadcast storm and defend DHCP spoong in the Extend operation mode.
Standard Mode (default)
Power
> Standard
VLAN
Extend
GSW-1820VHP
100 meters (328 feet)
PoE IP Camera
PoE
PoE
1000BASE-T UTP with PoE
Extend Mode
Standard
Power
VLAN
> Extend
PoE
GSW-1820VHP
250 meters (820 feet)
PoE IP Camera
PoE
10BASE-T UTP with PoE
9
Page 10
Flexible Extension Solution
The two mini-GBIC slots built in the GSD/GSW 802.3at PoE+ Switch series are
compatible with the 1000BASE-SX/LX SFP (Small Form-factor Pluggable)
ber transceiver, uplinked to the backbone switch and monitoring center in long
distance. The distance can be extended from 550 meters (multi-mode ber) to
10/20/30/40/50/60/70/120 kilometers (single-mode ber or WDM ber). They are
well suited for applications within the enterprise data centers and distributions.
Robust Protection
The GSD/GSW 802.3at PoE+ Switch series provides contact discharge of ±6KV DC
and air discharge of ±8KV DC for Ethernet ESD protection. It also supports ±6KV
surge immunity to improve product stability and protects users’ networks from
devastating ESD attacks, making sure the ow of operation does not uctuate.
Easy Installation and Cable Connection
As data and power are transmitted over one cable, the GSD/GSW 802.3at PoE+
Switch series does not need a second cable and electrical outlets on the wall,
ceiling or any unreachable place. Thus, it helps to lower the installation costs and
simplify the installation eort. All the RJ45 copper interfaces of the GSD/GSW
802.3at PoE+ Switch series support 10/100/1000Mbps auto-negotiation for optimal
speed detection through RJ45 Category 6, 5 or 5e cable. It also supports standard
auto-MDI/MDI-X that can detect the type of connection to any Ethernet device
without requiring special straight-through or crossover cables.
1.3 Features
Physical Port
GSD-1222VHP
8-port 10/100/1000BASE-T Gigabit RJ45 copper
2 1000BASE-X mini-GBIC SFP interfaces
2 10/100/1000BASE-T TP interfaces
GSW-1820VHP
16-port 10/100/1000BASE-T Gigabit RJ45 copper
2 1000BASE-X mini-GBIC SFP interfaces
GSW-2620VHP
24-port 10/100/1000BASE-T Gigabit RJ45 copper
2 1000BASE-X mini-GBIC SFP interfaces
10
Page 11
Power over Ethernet
Complies with IEEE 802.3af/at Power over Ethernet end-span PSE
Up to 8/16/24 ports of IEEE 802.3af/at devices powered
Supports PoE Power up to 32 watts for each PoE port
Each port supports 52V DC power to PoE powered device (GSD-1222VHP)
120-watt PoE budget (GSD-1222VHP)
Each port supports 54V DC power to PoE powered device (GSW-1820VHP/
GSW-2620VHP)
300-watt PoE budget (GSW-1820VHP/GSW-2620VHP)
Auto detects powered device (PD)
Circuit protection prevents power interference between ports
Remote power feeding up to 100m in standard mode and 250m in extend
mode
Smart LCD
The LCD switch features “Standard”, “VLAN” and “Extend” mode selection;
the “Extend” mode features 20-watt PoE transmission distance of 250m at
speed of 10Mbps and VLAN isolation
The LCD switch is able to isolate ports to prevent broadcast storm and defend
DHCP spoong
Power low-voltage, power over-voltage and PSE over-temperature protection
Screen saver, fan control, factory default and save conguration
PoE management
- Total PoE power budget control
- Per port PoE function enable/disable
- PoE port power feeding priority
- Per PoE port power limitation
- PD alive check
Switching
Hardware-based 10/100/1000Mbps auto-negotiation and auto MDI/MDI-X
Flow control for full duplex operation and back pressure for half duplex
operation
9216bytes packet size
Integrates address look-up engine, supporting 8K absolute MAC addresses
These switches provide three dierent running speeds – 10Mbps, 100Mbps and
1000Mbps and automatically distinguish the speed of the incoming connection.
This section describes the hardware features of 802.3at PoE+ Switch. For easier
management and control of the 802.3at PoE+ Switch, familiarize yourself with its
display indicators and ports. Front panel illustrations in this chapter display the unit
LED indicators. Before connecting any network device to the 802.3at PoE+ Switch,
please read this chapter carefully.
2.1 Front Panel
The Front Panel of the 802.3at PoE+ Switch consists of 8/16/24 802.3af/at auto-
sensing 10/100/1000Mbps Ethernet RJ45 ports and 2 Gigabit TP/SFP ports. The
LCD monitor and LED Indicators are also located on the front panel of the 802.3at
PoE+ Switch.
ment and Status”, “Switch Mode: Standard, VLAN, Extend”, “Budget
and Bandwidth Control”, “Screen Saver”, “Fan Control”, and “Factory
Default”.
2.1.1 LCD Monitor Indicators
The 802.3at PoE+ Switch has an LCD monitor designed for network administrator
who can easily obtain real-time per PoE port output watts information and system
status display, such as over voltage, low voltage, and PoE chipset over temperature
function. The details of each message on the LCD monitor are shown below:
GSD-1222VHP/GSW-1820VHP/GSW-2620VHP LCD Display
Switch Port Information
30.3
---M---
01W
PD light load protection
PD overload protection
Short-circuit protection
PoE Usage
ULP02---M---
OLP
03
SCP04---M---
----W05---M---
13.6
06W
14.4
07W
---M---
---M---
---M---
PB:300WTP:0WPD:3
Power Budget Total PoE
Switch Port Information
----
---M---
01W
----
---M---
02W
WARNING!
----W03---M---
Main supply voltage
is low!
----W04---M---
All ports had shut-
----W05---M---
down.
----
---M---
06W
----
---M---
07W
M
M
M
M
M
M
M
----
08W
----
09W
----
10W
----
11W
----
12W
----
13W
----
14W
---M---
---M---
---M---
---M---
---M---
---M---
---M---
PD:0PB:300WTP:0W
M
M
M
M
M
M
M
Switch Port Information
----
---M---
01W
----
---M---
02W
WARNING!
----W03---M---
Main supply voltage
is High!
----W04---M---
All ports had shut-
----W05---M---
down.
----
---M---
06W
----
---M---
07W
Power Low-voltage ProtectionPower Over-voltage ProtectionPSE Over-temperature Protection
M
M
M
M
M
M
M
Output
M
M
M
M
M
M
M
----
08W
----
09W
-OFF
10-
----
11W
----
12W
----
13W
----
14W
----
08W
----
09W
----
10W
----
11W
----
12W
----
13W
----
14W
877M---
M
---M867
M
---M---
M
---M---
M
---M---
M
---M---
M
---M---
M
Number of PDs
---M---
M
---M---
M
---M---
M
---M---
M
---M---
M
---M---
M
---M---
M
PD:0PB:300WTP:0W
Network traffic
PoE OFF
Switch Port Information
----
---M---
01W
----
---M---
02W
WARNING!
----W03---M---
The PSE device is too
hot!
----W04---M---
All ports had shut-
----W05---M---
down.
----
---M---
06W
----
---M---
07W
M
M
M
M
M
M
M
----
08W
----
09W
----
10W
----
11W
----
12W
----
13W
----
14W
---M---
---M---
---M---
---M---
---M---
---M---
---M---
PD:0PB:300WTP:0W
M
M
M
M
M
M
M
16
Note
1. The LCD screens of the GSD-1222VHP and GSW-1820VHP and
GSW-2620VHP are the same, except the number of ports and
port allocation.
2. The LCD screens of the GSD-1222VHP and GSW-1820VHP and
GSW-2620VHP will refresh every 15 seconds.
3. For details on LCD Management feature, please refer to “2.3
LCD Management”.
Page 17
The detailed Smart LCD description of each item is shown below:
ParametersDescription
30.3W
(example)
OLP
ULP
SCP
OFF
---WIt means the port is without a PD device insert.
---MIt means this port does not have data transfers.
<1MIt means this port data rate transfers less than 1M.
877M
(example)
PBIt means power budget.
TBIt means total PoE power output information.
PDThe number of PDs inserted.
It means the output power port of the PoE switch.
It means the port is overloaded corresponding to the PSE, and
the port stops powering.
It means the port corresponding to the PSE is lightly loaded and
the port stops powering (When the current on the network is less
than 7.5mA, the PSE thinks the PD has been dialed out and the
port stops powering).
It means the port corresponding to the PSE appears to be shortcircuited and the port stops powering.
It means the white and blue OFF shows that the port is blocked
by the menu command.
The white and blue character represents the data transmission
rate while the red character represents the data transmission rate
which is greater than the bandwidth setting, causing power to
restart the PSE port. If the resumption situation happens for 10
times within 1 hour, the power supply to the port will be cut o.
2.1.2 LED Indicators
System
LEDColorFunction
PWRGreenLights to indicate that the Switch has power.
17
Page 18
10/100/1000Mbps PoE Ports
LEDColorFunction
Lights
LNK/ACTGreen
Blinks
Lights Indicates the port is providing DC in-line power.
PoE-in-Use Amber
1000Mbps SFP Slot
LED ColorFunction
LNK/
Green
ACT
1000 Green Lights Indicates the port is successfully established at 1000Mbps.
1000Mbps TP Slot (GSD-1222VHP)
LEDColorFunction
LNK/
10/100RedLights
1000Green Lights
ACT
Green
O
Lights Indicates the port is successfully established at 1000Mbps.
Blinks
Lights
Blinks
Indicates the link through that port is successfully
established at 10/100/1000Mbps.
Indicates that the Switch is actively sending or
receiving data over that port.
Indicates the connected device is not a PoE
powered device (PD).
Indicates that the Switch is actively sending or receiving
data over that port.
Indicates the link through that port is successfully
established at 1000Mbps.
Indicates that the Switch is actively sending or receiving
data over that port.
Indicates the port is successfully established at
10/100Mbps
Indicates the port is successfully established at
1000Mbps.
1000Mbps TP Slot (GSW-1820VHP/GSW-2620VHP)
LEDColorFunction
LNK/
10/100RedLights
1000Green Lights
ACT
Green
Lights
Blinks
Indicates the link through that port is successfully
established at 1000Mbps.
Indicates that the Switch is actively sending or receiving
data over that port.
Indicates the port is successfully established at
10/100Mbps
Indicates the port is successfully established at
1000Mbps.
18
Page 19
2.2 Rear Panel
The rear panel of the 802.3at PoE+ Switch has an AC power socket (100 to 240V
AC, 50-60Hz, 2.5/5A).
For compatibility with electrical outlet standard in most areas of the world, the
802.3at PoE+ Switch’s power supply automatically adjusts to line power in the
range of 100-240V AC and 50/60Hz, 2.5/5A.
Plug the female end of the power cord rmly into the receptacle on the rear panel
of the 802.3at PoE+ Switch and the other end into an electrical outlet, and the
power will be ready.
Power
Notice
The device is a power-required device, which means it will not
work till it is powered. If your networks should be active all the
time, please consider using UPS (Uninterrupted Power Supply) for
your device. It will prevent you from network data loss or network
downtime. In some areas, installing a surge suppression device
may also help to protect your 802.3at PoE+ Switch from being
damaged by unregulated surge or current to the Switch or the
power adapter.
19
Page 20
2.3 LCD Management
The operation of the 5 buttons (Menu, Enter, Back, Up and Down) on the panel:
Menu (5 sec)
Enter
Back
30.3
01W
----
02W
----W03---M---
15.4W04-10M---
----W05---M---
----
06W
----
07W
---M867
---M---
---M---
---M---
M
08W
M
09W
M
10W
M
11-
M
12W
M
M
14W
----
---M---
-8.3
---M-<1
----
---M---
-OFF
---M---
----
---M---
17.6W13223M246
----
---M---
M
M
M
M
M
M
M
PB:300WTP:72WPD:4
Press the menu button to switch the “Switch Port Information”.
Press the menu button for about 5 seconds and enter the Main Menu. Choose
a menu item by scrolling up and down, and press the “Enter” key to get to the
menu item you have chosen. Press the “Back” key to return to the previous
menu.
Up
Down
Switch Port Information
20
Page 21
2.3.1 Switch Mode
There are three modes -- “Standard”, “VLAN” and “Extend” – for selection.
ModelGSD-1222VHPGSW-1820VHPGSW-2620VHP
Switch
Mode
Standard
(default)
VLAN
This mode makes the 802.3at PoE+ Switch operate as a general switch and
all PoE ports operate at 10/100/1000Mbps auto-negotiation.
This mode makes the
GSD-1222VHP operate as
a VLAN isolation switch
and
1. Port 1 to port 8 will
isolate respectively.
2. Port 1 to port 8 can
only communicate
with port 9~12
(uplink port).
This mode makes the
GSW-1820VHP operate as
a VLAN isolation switch
and
1. Port 1 to port 16 will
2. Port 1 to port 16 can
Function
isolate respectively.
only communicate with
port 17 and port 18
(uplink port).
This mode makes the
GSW-2620VHP operate as
a VLAN isolation switch
and
1. Port 1 to port 24 will
isolate respectively.
2. Port 1 to port 24 can
only communicate with
port 25 and port 26
(uplink port).
Extend
With
VLAN
Isolation
This mode makes
the GSD-1222VHP
operate as a VLAN
isolation switch and
1. Port 1 to port 8 will
isolate respectively.
2. Port 1 to port 8 can
only communicate
with port 9~12
(uplink port).
Due to the power allocation strategy of PSE, when the residual power of PoE is
too large, the power distribution of the port can be increased as much as possible
by increasing the power trimming of the PSE, so that the utilization of the PSE
power supply can be improved. There are four levels of budget control named
Unchanged (default), Add 5% PB, Add 10% PB and Add 15% PB.
1. The default PoE budget is 120W/300W in unchanged mode. If
you hope to have a full load of over 120W/300W, please select
Add 5% PB, Add 10% PB and Add 15% PB.
Note
2. In order to make sure the PSE power supply is not overloaded for a long
time, please try to ensure that TP is less than PB.
23
Page 24
2.3.3 PSE Port Priority
The Priority represents PoE ports priority. There are three levels of power priority
named Low, High and Critical. The priority is used in case the total power
consumption is over the total power budget. In this case the port with the lowest
priority will be turned off, and offer power for the port of higher priority. The
default port priority is “Low”.
2.3.4 PSE Port Enable
Allows user to disable or enable per port PoE function. The default is “Enable”.
24
Page 25
2.3.5 PD Type
Changing the PoE power-up mode can let non-standard PDs pass the procedures
of PoE power delivery process. This way, the switch can supply power to nonstandard PDs. The GSD/GSW 802.3at PoE+ Switch series can set the PoE powerup mode to be in Enhance mode, Standard mode or Legacy mode by the user
interface.
ObjectDescription
Enhance
(default)
StandardFully conforms to the IEEE 802.3 af/at standard.
Legacy
On the basis of standard mode, change the PD of class 0 to
AT mode; in addition, the current surge limit during power up
increases to the current limit of AT.
The legacy detection is to identify the PD devices that did not
follow the IEEE 802.3af standard and their unique electrical
signatures, in order for the PoE switch to provide the power to
those PD devices.
25
Page 26
2.3.6 Alive Check
The GSD/GSW 802.3at PoE+ Switch series can be congured to monitor connected
PD’s status in real time via traffic detection. Once there is no traffic at interval
time, the GSD/GSW 802.3at PoE+ Switch series is going to restart PoE port power,
and bring the PD back to work. It will greatly enhance the reliability and reduce
administrator management burden.
ObjectDescription
PortSelect the port number to enable Alive Check.
Status
Startup Time
(60~300s)
Interval Time
(60~300s)
Power O
(5~60s)
Allows user to enable or disable per port PD Alive Check
function. All ports are disabled as default value.
PD startup time.
This startup time is based on determining when to start to
measure the trac. The default startup time is 180 seconds.
Trac detection counter.
The switch detects no trac during this time and countdown
for interval time begins and port begins to reboot. The default
interval time is 180 seconds.
PoE Port Disable Timer
This column allows user to set the PoE device rebooting time.
The default power o time is 5 seconds.
26
Page 27
The PD Alive Check is not a dening standard, so the PoE device on the market
doesn’t report reboots done information to the PoE Switch. So user has to make
sure how long it takes for the PD to nish booting, and then set the time value
related column. The system is going to check the PD again according to the reboot
time. If you cannot make sure the precise booting time, we suggest you set it
longer.
Interval Time
No traffic!
Countdown
Power
OFF
IntervalPower OFF
Power
ON
Time(s)
PD Traffic=0
StartupPD readyPD Halt
0180450630 635
Startup
Figure 2-4: Alive Check Mechanism
2.3.7 Bandwidth Detection
When the network transmits “the highest data rate”, more than the set value,
over a single port, the switch will set off an alarm to warn the overuse of the
bandwidth. There are four levels of budget control, namely Unlimited (default), 400Mbps, 500Mbps and 600Mbps.
27
Page 28
2.3.8 Fan Control
Fan control is to achieve the set power with intelligent operation. There are four
levels of budget control, namely Always ON, 20% PB (default), 40% PB and
60% PB.
2.3.9 Screen Saver
There are four levels of budget control, namely Always ON, 10min (default),
20min and 30min.
28
Page 29
2.3.10 Language
There are two languages, namely English and Chinese.
2.3.11 Default Setting
Press “Yes” to reset to default.
2.3.12 System
Show the system information.
29
Page 30
3. Hardware Installation
Start up
Please refer to the following for your cabling:
10/100/1000BASE-T
All 10/100/1000BASE-T ports come with Auto-Negotiation capability. They
automatically support 1000BASE-T, 100BASE-TX and 10BASE-T networks. Users
only need to plug a working network device into one of the 10/100/1000BASE-T
ports, and then turn on the 802.3at PoE+ Switch. The port will automatically run
at 10Mbps, 20Mbps, 100Mbps or 200Mbps and 1000Mbps or 2000Mbps after the
negotiation with the connected device.
Cabling
Each 10/100BASE-TX port and 10/100/1000BASE-T port uses RJ45 sockets -similar to phone jacks -- for connection of unshielded twisted-pair cable (UTP).
The IEEE 802.3/802.3u/802.3ab Fast/Gigabit Ethernet standard requires Category
5 UTP for 100Mbps 100BASE-TX. 10BASE-T networks can use Cat.3, 4, 5 or
1000BASE-T uses 5/5e/6 UTP (see table below). Maximum distance is 100 meters
(328 feet).
Port TypeCable TypeConnector
10BASE-TCat.3, 4, 5, 2-pairRJ45
100BASE-TXCat.5, 5e UTP, 4-pairRJ45
1000BASE-TCat.5/5e/6 UTP, 4-pairRJ45
Any Ethernet devices like hubs/PCs can connect to the 802.3at PoE+ Switch by
using straight-through wires. The whole 10/100/1000Mbps ports are auto-MDI/
MDI-X that can be used on straight-through or crossover cable.
30
Page 31
3.1 Desktop Installation
To install the 802.3at PoE+ Switch on desktop, simply follow the following steps:
Step 1: Attach the rubber feet to the recessed areas on the bottom of the
802.3at PoE+ Ethernet Switch, as shown in Figure 3-1.
Menu (5 sec)
Enter
Up
G
S
W
Back
Figure 3-1: Attaching the Rubber Feet to the 802.3at PoE+ Switch
Step 2: Place the 802.3at PoE+ Switch on desktop near an AC power source.
Step 3: Keep enough ventilation space between the 802.3at PoE+ Switch and the
surrounding objects.
When choosing a location, please keep in mind the environmental
restrictions discussed in Chapter 1, Section 4, under Specifications.
Note
Step 4: Connect your 802.3at PoE+ Switch to 802.3af/802.3at complied power
devices (PDs) and other network devices.
A. Connect one end of a standard network cable to the
10/100/1000BASE-T RJ45 ports on the front panel of the 802.3at
PoE+ Switch.
B. Connect the other end of the cable to the network devices such as
printer servers, workstations or routers, etc.
-2620VH
P
2
4 8
6 10
PoE
12
14
16 20 24
4 6 82
18 22
Down
1
PWR
3 7
5
PoE
9 13 17 21
1
1
SFP
15 19 23
1000
LNK
LNK
10/100
25
AC
T
26
LNK
AC
PoE
T
In-Use
AC
T
1 3 5 7
12 14 1610
20 22 2418
9 1
1 13 15
SFP
17
19 21 23
17
18
Connection to the Switch requires UTP Category 5, 5e, 6 network
cabling with RJ45 tips. For more information, please see the
Note
Cabling Specification in Appendix A.
Step 5: Supply power to the 802.3at PoE+ Switch.
A. Connect one end of the power cable to the 802.3at PoE+ Switch.
B. Connect the power plug of the power cable to a standard wall outlet.
When the 802.3at PoE+ Switch receives power, the Power LED should remain solid
Green.
31
Page 32
3.2 Rack Mounting
To install the 802.3at PoE+ Switch in a 19-inch standard rack, follow the
instructions described below.
Step 1: Place your 802.3at PoE+ Switch on a hard at surface, with the front
panel positioned towards your front side.
Step 2: Attach a rack-mount bracket to each side of the 802.3at PoE+ Switch
with supplied screws attached to the package. Figure 3-2 shows how to
attach brackets to one side of the 802.3at PoE+ Switch.
Menu (5 sec)
Enter
Up
G
S
W
Back
Figure 3-2: Attaching the Brackets to the 802.3at PoE+ Switch.
You must use the screws supplied with the mounting brackets.
Damage caused to the parts by using incorrect screws would invalidate the warranty.
Step 3: Secure the brackets tightly.
Step 4: Follow the same steps to attach the second bracket to the opposite side.
Step 5: After the brackets are attached to the 802.3at PoE+ Switch, use suitable
screws to securely attach the brackets to the rack, as shown in Figure
3-3.
-2620VH
P
2
4 8 12 16
6
PoE
10 14
4 6 82
18 22
Down
20 24
1
PWR
3 7
5 9 13
PoE
1
1
SFP
15
17 21
19 23
1000
LNK
LNK
10/100
25
AC
T
26
LNK
AC
PoE
T
In-Use
AC
T
12
14 1610
1
3 5 7
20 22 2418
9 1
1
13 15
SFP
17
19 21 23
17
18
Menu (5 sec)
Enter
Up
G
S
W-2
6
2
0
Back
VH
P
2 6
4 8 12 16 20 24
PoE
10 14 18 22
Down
1
PWR
3 7 1
5 9 13 17 21
PoE
4 6 82
1
SFP
15 19 23
LNK1000
LNK
25 26
ACT
LNK10/100
ACT
PoE I
ACT
n-Use
12 14 1610
1
3 5 7
20 22 2418
9 1
1 13 15
17 19 21 23
SFP
17
18
Figure 3-3: Mounting the 802.3at PoE+ Switch in a Rack
Step 6: Proceed with Steps 4 and 5 of session 3.1 Desktop Installation to
connect the network cabling and supply power to your Switch.
32
Page 33
3.3 Installing the SFP Transceiver
The sections describe how to insert an SFP transceiver into an SFP slot of the
802.3at PoE+ Switch. The SFP transceivers are hot-pluggable and hot-swappable.
You can plug in and out the transceiver to/from any SFP port without having to
power down the 802.3at PoE+ Switch, as the Figure 3-4 shows.
1
2
Figure 3-4: Plugging in the SFP Transceiver
Approved PLANET SFP Transceivers
PLANET 802.3at PoE+ Switch supports both single mode and multi-mode SFP
transceivers. The following list of approved PLANET SFP transceivers is correct at
the time of publication:
Gigabit SFP Transceiver Modules
MGB-Series Module
LC Fiber Cable
MGB-GT
MGB-SX
MGB-LX
MGB-L30
MGB-L50
MGB-L70
MGB-L120
MGB-LA10
MGB-LB10
MGB-LA20
MGB-LB20
MGB-LA40
MGB-LB40
SFP-Port 1000BASE-T Module
SFP-Port 1000BASE-SX mini-GBIC module - 550m
SFP-Port 1000BASE-LX mini-GBIC module - 10km
SFP-Port 1000BASE-LX mini-GBIC module - 30km
SFP-Port 1000BASE-LX mini-GBIC module - 50km
SFP-Port 1000BASE-LX mini-GBIC module - 70km
SFP-Port 1000BASE-LX mini-GBIC module - 120km
SFP-Port 1000BASE-LX (WDM,TX:1310nm) - 10km
SFP-Port 1000BASE-LX (WDM,TX:1550nm) - 10km
SFP-Port 1000BASE-LX (WDM,TX:1310nm) - 20km
SFP-Port 1000BASE-LX (WDM,TX:1550nm) - 20km
SFP-Port 1000BASE-LX (WDM,TX:1310nm) - 40km
SFP-Port 1000BASE-LX (WDM,TX:1550nm) - 40km
33
Page 34
It is recommended to use PLANET SFP on the 802.3at PoE+
Switch. If you insert an SFP transceiver that is not supported, the
Note
802.3at PoE+ Switch will not recognize it.
1. Before we connect the 802.3at PoE+ Switch to the other network device, we
have to make sure both sides of the SFP transceivers are with the same media
type, for example, 1000BASE-SX to 1000BASE-SX; 1000BASE-LX to 1000BASELX.
2. Check whether the ber-optic cable type matches with the SFP transceiver
requirement.
To connect to 1000BASE-SX SFP transceiver, please use the multi-mode ber
cable with one side being the male duplex LC connector type.
To connect to 1000BASE-LX SFP transceiver, please use the single-mode ber
cable with one side being the male duplex LC connector type
Connect the Fiber Cable
1. Insert the duplex LC connector into the SFP transceiver.
2. Connect the other end of the cable to a device with SFP transceiver installed.
3. Check the LNK/ACT LED of the SFP slot on the front of the 802.3at PoE+
Switch. Ensure that the SFP transceiver is operating correctly.
Remove the Transceiver Module
1. Make sure there is no network activity anymore.
2. Remove the Fiber-Optic Cable gently.
3. Lift up the lever of the MGB module and turn it to a horizontal position.
4. Pull out the module gently through the lever, as the Figure 3-5 shows.
34
MGB-SX/LX
1
2
Figure 3-5: How to Pull Out the SFP Transceiver
Page 35
Never pull out the module without lifting up the lever of the
module and turning it to a horizontal position. Directly pulling out
the module could damage the module and the SFP module slot of
Note
the 802.3at PoE+ Switch.
3.4 Product Applications
Department/Workgroup PoE Switch:
Providing 8/16/24 PoE in-line power interfaces, the 802.3at PoE+ Switch can
easily build a power that centrally controls IP phone system, IP camera system
and wireless AP group for enterprises. Cameras can be installed around the corner
in the company or campus for surveillance demands. Without the power-socket
limitation, the 802.3at PoE+ Switch makes the installation of cameras easier and
As many as PoE VoIP phones, ATAs and other Ethernet/
non-Ethernet end-devices can be installed, but UPS is
3~5 watts
6~12 watts
10~12 watts
3~12 watts
3~25 watts
needed for uninterrupted power system and power control
system.
Wireless LAN Access Points
Access points can readily be installed in museums,
sightseeing sites, airports, hotels, campuses, factories and
warehouses.
IP Surveillance
For the sake of security, install IP cameras around
enterprises, museums, campuses, hospitals and bank
without considering location and electrical outlets.
PoE Splitter
As PoE Splitter splits the PoE 48V DC over the Ethernet
cable into 5/12V DC power output, network deployments
can easily be made without worrying about power outlet
locations, thus eliminating the costs for additional AC
wiring and reducing the installation time.
High Power PoE Splitter
As PoE Splitter splits the PoE 53V-54V DC over the
Ethernet cable into 24/12V DC power output, network
deployments can easily be made without worrying about
power outlet locations, thus eliminating the costs for
additional AC wiring and reducing the installation time.
36
30 watts
Note
High Power Speed Dome
This state-of-the-art design ts very nicely in various
network environments like trac centers, shopping malls,
railway stations, warehouses, airports and production
facilities for the most the demanding outdoor surveillance
applications. Electrician is not needed to install AC sockets.
Since each port of the 802.3at PoE+ Switch supports 52-54V DC
PoE power output, please make sure the PD’s acceptable DC power
range is from 52-54V DC. Otherwise, it will damage the PD.
Page 37
4. Power over Ethernet Overview
What is PoE?
PoE is an abbreviation of Power over Ethernet. The PoE technology means a
system safely transmits both power and data on Ethernet UTP cable. The IEEE
standard for PoE technology requires Category 5 cable or higher for high power
PoE levels, but can operate with Cat3 cable for low power levels. Power is supplied
in common mode over two or more of the dierential pairs of wires found in the
Ethernet cables and comes from a power supply within a PoE-enabled network
device such as an Ethernet switch or can be injected into a cable run with a mid-
span power supply.
The original IEEE 802.3af-2003 PoE standard provides up to 15.4W of DC power
(minimum 44V DC and 350mA) to each device. Only 12.95W is assured to be
available at the powered device as some power is dissipated in the cable.
The updated IEEE 802.3at-2009 PoE standard, also known as PoE+ or PoE plus,
provides up to 25.5W of power. The 2009 standard prohibits a powered device
from using all four pairs for power.
The 802.3af/802.3at denes two types of source equipment: mid-span and end-
span.
Mid-span
Mid-span device is placed between legacy switch and the powered device. Mid-span
taps the unused wire pairs 4/5 and 7/8 to carry power; the other four are for data
transmission.
End-span
End-span device is directly connected with powered device. End-span could also
tap the wire 1/2 and 3/6.
PoE System Architecture
The specication of PoE typically requires two devices: the Powered Source
Equipment (PSE) and the Powered Device (PD). The PSE is either an end-span or
a mid-span, while the PD is a PoE-enabled terminal, such as IP phones, wireless
LAN, etc. Power can be delivered over data pairs or spare pairs of standard Cat5
cabling.
Powered Source Equipment (PSE)
Power sourcing equipment (PSE) is a device such as a switch that provides
(sources) power on the Ethernet cable. The maximum allowed for continuous
output power per cable in IEEE 802.3af is 15.4W. A later specication, IEEE
802.3at, oers 25.50W. When the device is a switch, it is commonly called an
end-span (although IEEE 802.3af refers to it as endpoint). Otherwise, if it is an
37
Page 38
intermediary device between a non-PoE capable switch and a PoE device, it is
called a mid-span. An external PoE injector is a mid-span device.
Powered Device
A powered device (PD) is a device powered by a PSE and thus consumes energy.
Examples include wireless access points, IP phones, and IP cameras. Many
powered devices have an auxiliary power connector for an optional, external power
supply. Depending on the PD design, some, none, or all power can be supplied
from the auxiliary port, with the auxiliary port sometimes acting as backup power
in case of PoE supplied power failure.
How Power is Transferred through Cable
A standard Cat5 Ethernet cable has four twisted pairs, but only two of these are
used for 10BASE-T and 100BASE-TX. The specication allows two options for using
these cables for power, shown in Figure 1 and Figure 2:
The spare pairs are used. Figure 1 shows the pair on pins 4 and 5 connected
together and forming the positive supply, and the pair on pins 7 and 8 connected
and forming the negative supply. (In fact, a late change to the spec allows either
polarity to be used).
38
POWER SOURCING
EQUIPMENT (PSE)
4
5
1
+
48V
TX
-
RX
Figure 1: Power Supplied over Spare Pins
2
3
6
7
8
SPARE PAIR
SIGNAL PAIR
SIGNAL PAIR
SPARE PAIR
POWERED DEVICE
(PD)
4
5
1
RX
2
3
6
7
8
TX
DC / DC
Converter
Converter
Page 39
The data pairs are used. Since Ethernet pairs are transformers coupled at each
end, it is possible to apply DC power to the center tap of the isolated transformer
without upsetting the data transfer. In this mode of operation, the pair on pins 3
and 6 and the pair on pins 1 and 2 can be of either polarity.
POWER SOURCING
EQUIPMENT (PSE)
+ / -
TX
/
-
+
48V
RX
4
5
1
2
3
6
7
8
SPARE PAIR
SIGNAL PAIR
SIGNAL PAIR
SPARE PAIR
POWERED DEVICE
(PD)
4
5
1
RX
2
3
6
7
8
DC / DC
Converter
TX
Figure 2: Power Supplied over Data Pins
When to install PoE
Consider the following scenarios:
z You’re planning to install the latest VoIP phone system to minimize cabling
building costs when your company moves into a new oce next month.
z The company sta has been clamoring for a wireless access point in the picnic
area behind the building so they can work on their laptops through lunch, but
the cost of electrical power to the outside is not aordable.
z Management asks for IP Surveillance Cameras and business access systems
throughout the facility, but they would rather avoid another electrician’s
payment.
39
Page 40
5. Troubleshooting
This chapter contains information to help you solve issues. If the 802.3at PoE+
Switch is not functioning properly, make sure the 802.3at PoE+ Switch was set up
according to instructions in this manual.
The Link LED is not lit.
Solution:
Check the cable connection and also try to swap one new cable.
1000BASE-T port link LED is lit, but the trac is irregular.
Solution:
Make sure the attached device is not set to full duplex. Some devices use a
physical or software switch to change duplex modes. Auto-negotiation may not
recognize this type of full-duplex setting.
Why the Switch doesn’t connect to the network.
Solution:
Check the LNK/ACT LED on the 802.3at PoE+ Switch. Try another port on the
802.3at PoE+ Switch. Make sure the cable is installed properly. Make sure the
cable is the right type. Turn o the power. After a while, turn on the power again.
Why the GSD/GSW Switch, connected to PoE device, cannot be powered on.
Solution:
1. Please check the cable type of the connection from GSD/GSW switch to the
other end. The cable should be an 8-wire UTP, Category 5 or above and EIA568
cable within 100 meters. A cable with only 4-wire, short loop or over 100 meters
will aect the power supply.
2. Please make sure the device is fully complied with IEEE 802.3af/IEEE 802.3at
standard.
What is the power output of each PoE port?
Solution:
1. Each PoE port supports 52-54V DC, 600mA and a maximum of 30 watts of
power output. Detect and inject by the standard of IEEE 802.3at.
2. Each PoE port supports 52-54V DC, 300mA and a maximum of 15.4 watts
of power output. Detect and inject by the standard of IEEE 802.3af.
40
Page 41
Appendix A Networking Connection
A.1 Switch's Data RJ45 Pin Assignments - 1000Mbps, 1000BASE-T
PIN NOMDIMDI-X
1BI_DA+BI_DB+
2BI_DA-BI_DB-
3BI_DB+BI_DA+
4BI_DC+BI_DD+
5BI_DC-BI_DD-
6BI_DB-BI_DA-
7BI_DD+BI_DC+
8BI_DD-BI_DC-
Implicit implementation of the crossover function within a twisted-pair cable, or at
a wiring panel, while not expressly forbidden, is beyond the scope of this standard.
A.2 10/100Mbps, 10/100BASE-TX
When connecting Switch to another Fast Ethernet switch, a straight-through or
crossover cable might be necessary. Each port of the Switch supports auto-MDI/
MDI-X detection, meaning you can directly connect the Switch to any Ethernet
devices without making a crossover cable. The following table and diagram show
the standard RJ45 receptacle/connector and their pin assignments:
RJ45 Connector Pin Assignment
Contact
1Tx + (transmit)Rx + (receive)
2Tx - (transmit)Rx - (receive)
3Rx + (receive)Tx + (transmit)
4, 5Not used
6Rx - (receive)Tx - (transmit)
7, 8Not used
Media Dependent Interface
MDI
Media Dependent Interface - Cross
MDI-X
41
Page 42
The standard cable, RJ45 pin assignment
The standard RJ45 receptacle/connector
There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The
following shows the pin allocation and color of straight-through cable and crossover
cable connection:
Straight Cable
12345678
12345678
Crossover Cable
12345678
12345678
SIDE 1
SIDE 2
SIDE 1
SIDE 2
SIDE 1
1 = White/Orange
2 = Orange
3 = White/Green
4 = Blue
5 = White/Blue
6 = Green
7 = White/Brown
8 = Brown
SIDE 1SIDE 2
1 = White/Orange
2 = Orange
3 = White/Green
4 = Blue
5 = White/Blue
6 = Green
7 = White/Brown
8 = Brown
SIDE 2
1 = White/Orange
2 = Orange
3 = White/Green
4 = Blue
5 = White/Blue
6 = Green
7 = White/Brown
8 = Brown
1 = White/Green
2 = Green
3 = White/Orange
4 = Blue
5 = White/Blue
6 = Orange
7 = White/Brown
8 = Brown
Figure A-1: Straight-through and Crossover Cable
Please make sure your connected cables are with the same pin assignment and
color as the above picture before deploying the cables into your network.
Manufacturer‘s Name : Planet Technology Corp.
Manufacturer‘s Address : 10F., No.96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan
is herewith confirmed to comply with the requirements set out in the Council Directive on the
Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive
2014/30/EU.
For the evaluation regarding the EMC, the following standards were applied:
EN 55032 2015+AC:2016 Class A
AS/NZS CISPR 32 2015 Class A
EN 55035 2017
EN 60950-1 2006+A11:2009+A1:2010+A12:2011+A2:2013
Responsible for marking this declaration if the:
Manufacturer
Authorized representative established within the EU (if applicable):
Company Name: Planet Technology Corp.
Company Address: 10F., No.96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan
Person responsible for making this declaration
Name, Surname Jonas Yang
Position / Title : Product Manager
Ethernet Switch with PoE LCD Monitor
EN 61000-3-2 2014 Class A
EN 61000-3-3 2013
Authorized representative established within the EU
PLANET TECHNOLOGY CORPORATION
10F., No.96, Minquan Rd., Xindian Dist., New Taipei City, Taiwan
*Type of Product : 16/24-Port 10/100/1000T 802.3at PoE + 2-Port Gigabit SFP Ethernet Switch with
*Model Number : GSW-1820VHP, GSW-2620VHP
* Produced by:
Manufacturer‘s Name : Planet Technology Corp.
Manufacturer‘s Address : 10F., No.96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan
is herewith confirmed to comply with the requirements set out in the Council Directive on the
Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive
2014/30/EU.
For the evaluation regarding the EMC, the following standards were applied:
EN 55032 2015 Class A
AS/NZS CISPR 32 2015
EN 55024 2010+A1:2015
Responsible for marking this declaration if the:
Manufacturer
Authorized representative established within the EU (if applicable):
Company Name: Planet Technology Corp.
Company Address: 10F., No.96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan
Person responsible for making this declaration
Name, Surname Jonas Yang
Position / Title : Director
LCD PoE Monitor (300W)
EN 61000-3-2 2014 Class A
EN 61000-3-3 2013
Authorized representative established within the EU
PLANET TECHNOLOGY CORPORATION
10F., No.96, Minquan Rd., Xindian Dist., New Taipei City, Taiwan