Planet GSW-2620VHP, GSD-1222VHP, GSW-1820VHP User guide

Page 1
8-/16-/24-Port 10/100/1000T 802.3at PoE+
Gigabit SFP Ethernet Switch with Smart LCD
GSD-1222VHP/GSW-1820VHP/GSW-2620VHP
User’s Manual
Page 2
Copyright
Copyright © 2018 by PLANET Technology Corp. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission of PLANET.
PLANET makes no representations or warranties, either expressed or implied,
with respect to the contents hereof and specically disclaims any warranties, merchantability or tness for any particular purpose. Any software described
in this manual is sold or licensed "as is". Should the programs prove defective following their purchase, the buyer (and not PLANET, its distributor, or its dealer) assumes the entire cost of all necessary servicing, repair, and any incidental or consequential damages resulting from any defect in the software. Further, PLANET reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation to notify any person of such revision or changes
All brand and product names mentioned in this manual are trademarks and/or registered trademarks of their respective holders.
Trademarks
PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.
Disclaimer
PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and makes no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or
tness for a particular purpose.
PLANET has made every eort to ensure that this User’s Manual is accurate;
PLANET disclaims liability for any inaccuracies or omissions that may have
occurred. Information in this User’s Manual is subject to change without notice
and does not represent a commitment on the part of PLANET. PLANET assumes
no responsibility for any inaccuracies that may be contained in this User’s Manual.
PLANET makes no commitment to update or keep current the information in this
User’s Manual, and reserves the right to make improvements to this User’s Manual and/or to the products described in this User’s Manual, at any time without notice. If you nd information in this manual that is incorrect, misleading, or incomplete,
we would appreciate your comments and suggestions.
Page 3
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
WEEE Warning
To avoid the potential eects on the environment and human health as a
result of the presence of hazardous substances in electrical and electronic equipment, end users of electrical and electronic equipment should understand the meaning of the crossed-out wheeled bin symbol. Do not
dispose of WEEE as unsorted municipal waste; WEEE should be collected
separately.
Revision
PLANET 8-/16-/24-Port 10/100/1000T 802.3at PoE+ Gigabit SFP Ethernet Switch
with Smart LCD User's Manual
Models: GSD-1222VHP, GSW-1820VHP, GSW-2620VHP
Revision: 3.0 (Dec., 2018)
Part No.: 2351-AK5070-002
Page 4
Table of Contents
1. Introduction ............................................................................................... 5
1.1 Package Contents ................................................................................ 5
1.2 Product Description .............................................................................. 6
1.3 Features ............................................................................................10
1.4 Specications .....................................................................................12
2. Hardware Description .................................................................................15
2.1 Front Panel ........................................................................................15
2.1.1 LCD Monitor Indicators ..............................................................16
2.1.2 LED Indicators ..........................................................................17
2.2 Rear Panel .........................................................................................19
2.3 LCD Management ............................................................................... 20
2.3.1 Switch Mode ...........................................................................21
2.3.2 Budget Control ........................................................................23
2.3.3 PSE Port Priority ......................................................................24
2.3.4 PSE Port Enable .......................................................................24
2.3.5 PD Type ..................................................................................25
2.3.6 Alive Check .............................................................................26
2.3.7 Bandwidth Detection ................................................................ 27
2.3.8 Fan Control .............................................................................28
2.3.9 Screen Saver ..........................................................................28
2.3.10 Language ................................................................................29
2.3.11 Default Setting ........................................................................ 29
2.3.12 System ...................................................................................29
3. Hardware Installation ................................................................................. 30
3.1 Desktop Installation ............................................................................ 31
3.2 Rack Mounting ................................................................................... 32
3.3 Installing the SFP Transceiver ..............................................................33
3.4 Product Applications ............................................................................ 35
3.5 Power over Ethernet Powered Devices ..................................................36
4. Power over Ethernet Overview ....................................................................37
5. Troubleshooting .........................................................................................40
Appendix A Networking Connection ..................................................................41
A.1 Switch's Data RJ45 Pin Assignments - 1000Mbps, 1000BASE-T ................41
A.2 10/100Mbps, 10/100BASE-TX ...............................................................41
Page 5
1. Introduction
Thank you for purchasing PLANET 8/16/24-Port 10/100/1000T 802.3at PoE+ Gigabit
SFP Ethernet Switch series, GSD-1222VHP, GSW-1820VHP and GSW-2620VHP. The descriptions of these models are shown below:
GSD-1222VHP
GSW-1820VHP
GSW-2620VHP
“802.3at PoE+ Switch” is used as an alternative name in this user’s manual.
8-Port 10/100/1000T 802.3at PoE + 2-Port Gigabit SFP + 2-Port Gigabit TP Ethernet Switch
16-Port 10/100/1000T 802.3at PoE + 2-Port Gigabit SFP Ethernet Switch
24-Port 10/100/1000T 802.3at PoE + 2-Port Gigabit SFP Ethernet Switch
1.1 Package Contents
Open the box of the 802.3at PoE+ Switch and carefully unpack it. The box should
contain the following items:
802.3at PoE+ Switch x 1 User’s Manual x 1
Power Cord x 1 Screws Package x 1
Rack-mounting Brackets x 2 Rubber Feet x 4
5
Page 6
If any of these pieces are missing or damaged, please contact your dealer
immediately; if possible, retain the carton including the original packing material,
and use them again to repack the product in case there is a need to return it to us for repair.
1.2 Product Description
Ideal High-performance Integration Solution for Secure IP Surveillance Infrastructure
Particularly designed for the growing popular IP surveillance applications, PLANET GSD/GSW 802.3at PoE+ Switch series is positioned as a surveillance switch with the central power management and IP camera monitoring.
The GSD/GSW 802.3at PoE+ Switch series brings an ideal, secure surveillance system at a lower total cost. The GSD/GSW 802.3at PoE+ Switch series provides
multiple 10/100/1000 Mbps 802.3at/af PoE ports able to supply sucient PoE
power to IEEE 802.3at PoE IP cameras at the same time. It is also able to be
connected with an 8-/16-/32-channel NVR system, uplinked to the backbone switch
and the monitoring center. With such a high-performance switch architecture, the
recorded video les from the PoE IP cameras can be saved in the NVR system to
enable the administrators to control and monitor the surveillance images both in the local LAN and the remote sites.
Model GSD-1222VHP GSW-1820VHP GSW-2620VHP
10/100/1000T Copper 8 x RJ45 16 x RJ45 24 x RJ45
10/100/1000T Copper 2 x RJ45 -- --
1000X Fiber Optic 2 x SFP Slots 2 x SFP Slots 2 x SFP Slots
802.3af/at PoE+ Ports 8 16 24
PoE Budget 120 watts 300 watts 300 watts
Enclosure 12” metal case 19” metal case 19” metal case
6
Page 7
Just “Plug and Watch” for a Quick Solution
The GSD/GSW 802.3at PoE+ Switch series is an ideal Plug and Watch Power over Ethernet solution which provides quick installation, real-time PoE work status monitoring and immediate troubleshooting through its unique LCD display to
improve work eciency and quality without any PC or software required.
The GSD/GSW 802.3at PoE+ Switch series is equipped with 8/16/24 10/100/1000BASE-T ports featuring 30-watt 802.3at Power over Ethernet Plus (PoE+) copper interfaces. With a total PoE power budget of up to 300 watts and non-blocking data switching performance, the GSD/GSW 802.3at PoE+ Switch
series fullls the demand of sucient PoE power for HD IP surveillance. It oers a
desktop-sized, reliable and visible power solution for small businesses and system integrators deploying Power over Ethernet networks.
Smart LCD Power LED
Menu/Enter/Back Up/Down Button
PoE & LNK/ACT Status
Gigabit SFP LNK/ACT Status
16 x 10/100/1000BASE-T 802.3at PoE+
2 x Gigabit SFP
7
Page 8
Smart and Intuitive LCD Control
4 6 82
1 3 5 7
12 14 1610
9 11 13 15
GSW-1820VHP
1
PWR
Up
Down
Menu (5 sec)
Enter
Back
5 9 13
3 7 11 15
PoE
2 6 10 14
4 8 12 16
PoE
PoE In-Use
ACTLNK1000 ACTLNK10/100
ACT
LNK
SFP
17 18
SFP
17 18
16-Port 10/100/1000T 802.3at PoE
+
2-Port Gigabit SFP Ethernet Switch
Switch Port Information
30.3
01 W
---M867
M
----
02 W
---M---
M
----W03---M---
M
15.4W04-10M---
M
----W05---M---
M
----
06 W
---M---
M
----
07 W
---M---
M
----
08 W
---M---
M
-8.3
09 W
---M-<1
M
----
10 W
---M---
M
-OFF
11 -
---M---
M
----
12 W
---M---
M
17.6W13223M246
M
----
14 W
---M---
M
PB:300W TP:72W PD:0
Main Menu
01 —
02 —
03 —
05 —
06 —
07 —
08 —
Switch Mode
Budget Control
PSE Port Priority
PD Type
Alive Check
Bandwidth
Fan Control
04 —
PSE Port Enable
System
<Back>: Return
PLANET 802.3af/at PoE Switch
www.planet.com.tw
Model: FGSW-2622VHP
HW ver: V2.0
SW ver: V3.01
PSE Port Enable
Port Status
>
Enable 01 Disable
<UP>/<Down>:Select <Enter>:Confirm <Back>:Return
Current Setting: Enable
Switch Mode
Options:
VLAN
Extend
Standard>
The GSD/GSW 802.3at PoE+ Switch series provides an intuitive color panel on its front panel that facilitates the Ethernet management and PoE PD management.
They greatly promote management eciency in large-scale network, such as
enterprises, hotels, shopping malls, government buildings, and other public areas,
and feature the following special management and status functions:
 PoE management and status
 Port management and status
Switch Mode: Standard, VLAN, Extend
 Budget and bandwidth control
 PD alive check
Maintenance: Screen saver, fan control, factory default and save conguration
8
Page 9
Standard, VLAN and Extend Operation Modes Oered
The GSD/GSW 802.3at PoE+ Switch series provides Standard, VLAN and Extend
operation modes. The GSD/GSW 802.3at PoE+ Switch series operates as a normal
IEEE 802.af/at PoE Switch in the Standard operation mode. The VLAN operation mode features the port-based VLAN function that can help to prevent the IP camera’s multicast or broadcast storm from inuencing each other.
VLAN Isolation Mode
Standard
> VLAN
Extend
NVR
Ports 17 and 18 for uplink
1000
Ports 1~16 Access Permitted
PoE
PoE
PoE
IP Camera
IP Camera
IP Camera
Ports 1 to 16
Access Denied
GSW-1820VHP
PC
1000
1000BASE-SX/LX Fiber-optic
1000BASE-T UTP
PoE
1000BASE-T UTP with PoE
In the Extend operation mode, the GSD/GSW 802.3at PoE+ Switch series operates
on a per-port basis at 10Mbps duplex operation but can support 20-watt PoE
power output over a distance of up to 250 meters overcoming the 100m limit on
Ethernet UTP cable. With this brand-new feature, the GSD/GSW Series provides
an additional solution for 802.3af/at PoE distance extension, thus saving the cost
of Ethernet cable installation. Its VLAN isolation function isolates ports so as to prevent broadcast storm and defend DHCP spoong in the Extend operation mode.
Standard Mode (default)
Power
> Standard
VLAN
Extend
GSW-1820VHP
100 meters (328 feet)
PoE IP Camera
PoE
PoE
1000BASE-T UTP with PoE
Extend Mode
Standard
Power
VLAN
> Extend
PoE
GSW-1820VHP
250 meters (820 feet)
PoE IP Camera
PoE
10BASE-T UTP with PoE
9
Page 10
Flexible Extension Solution
The two mini-GBIC slots built in the GSD/GSW 802.3at PoE+ Switch series are compatible with the 1000BASE-SX/LX SFP (Small Form-factor Pluggable)
ber transceiver, uplinked to the backbone switch and monitoring center in long distance. The distance can be extended from 550 meters (multi-mode ber) to 10/20/30/40/50/60/70/120 kilometers (single-mode ber or WDM ber). They are
well suited for applications within the enterprise data centers and distributions.
Robust Protection
The GSD/GSW 802.3at PoE+ Switch series provides contact discharge of ±6KV DC and air discharge of ±8KV DC for Ethernet ESD protection. It also supports ±6KV surge immunity to improve product stability and protects users’ networks from devastating ESD attacks, making sure the ow of operation does not uctuate.
Easy Installation and Cable Connection
As data and power are transmitted over one cable, the GSD/GSW 802.3at PoE+ Switch series does not need a second cable and electrical outlets on the wall, ceiling or any unreachable place. Thus, it helps to lower the installation costs and
simplify the installation eort. All the RJ45 copper interfaces of the GSD/GSW
802.3at PoE+ Switch series support 10/100/1000Mbps auto-negotiation for optimal speed detection through RJ45 Category 6, 5 or 5e cable. It also supports standard auto-MDI/MDI-X that can detect the type of connection to any Ethernet device
without requiring special straight-through or crossover cables.
1.3 Features
Physical Port
GSD-1222VHP
 8-port 10/100/1000BASE-T Gigabit RJ45 copper
 2 1000BASE-X mini-GBIC SFP interfaces
 2 10/100/1000BASE-T TP interfaces
GSW-1820VHP
 16-port 10/100/1000BASE-T Gigabit RJ45 copper
 2 1000BASE-X mini-GBIC SFP interfaces
GSW-2620VHP
 24-port 10/100/1000BASE-T Gigabit RJ45 copper
 2 1000BASE-X mini-GBIC SFP interfaces
10
Page 11
Power over Ethernet
 Complies with IEEE 802.3af/at Power over Ethernet end-span PSE
Up to 8/16/24 ports of IEEE 802.3af/at devices powered
 Supports PoE Power up to 32 watts for each PoE port
Each port supports 52V DC power to PoE powered device (GSD-1222VHP)
120-watt PoE budget (GSD-1222VHP)
Each port supports 54V DC power to PoE powered device (GSW-1820VHP/
GSW-2620VHP)
300-watt PoE budget (GSW-1820VHP/GSW-2620VHP)
 Auto detects powered device (PD)
 Circuit protection prevents power interference between ports
 Remote power feeding up to 100m in standard mode and 250m in extend
mode
Smart LCD
 The LCD switch features “Standard”, “VLAN” and “Extend” mode selection;
the “Extend” mode features 20-watt PoE transmission distance of 250m at
speed of 10Mbps and VLAN isolation
 The LCD switch is able to isolate ports to prevent broadcast storm and defend
DHCP spoong
 Power low-voltage, power over-voltage and PSE over-temperature protection
Screen saver, fan control, factory default and save conguration
 PoE management
- Total PoE power budget control
- Per port PoE function enable/disable
- PoE port power feeding priority
- Per PoE port power limitation
- PD alive check
Switching
Hardware-based 10/100/1000Mbps auto-negotiation and auto MDI/MDI-X
 Flow control for full duplex operation and back pressure for half duplex
operation
 9216bytes packet size
Integrates address look-up engine, supporting 8K absolute MAC addresses
IEEE 802.1Q VLAN transparency
 Automatic address learning and address aging
11
Page 12
Hardware
12/19-inch desktop size, 1U height, rack mountable
 2-inch color LCD with smart management functions
 LED indicators for system power, per port PoE ready and PoE activity, speed,
Link/Act
1/3 silent fans to provide stable and ecient power performance
Supports Energy-Ecient Ethernet (EEE) function (IEEE 802.3az)
Supports contact discharge of ±6KV DC and air discharge of ±8KV DC for
Ethernet ESD protection
Supports ±6KV surge immunity
1.4 Specications
Model GSD-1222VHP GSW-1820VHP GSW-2620VHP
Hardware Specications
802.3af/at PoE
Injector Port
10/100/1000BASE-T
MDI/MDIX Ports
10/100/1000BASE-T
MDI/MDIX Ports
1000BASE-X SFP/
mini-GBIC Slots
Switch Architecture Store-and-Forward
Switch Fabric
Switch Throughput@64 bytes
MAC Address Table 8K entries
Maximum Frame
Size
Flow Control
24Gbps/ non-blocking
18Mpps@64 bytes 26.8Mpps@64
IEEE 802.3x pause frame for full duplex; back pressure for
half duplex
8 16 24
8 16 24
2 --
2
36Gbps/ non-blocking
bytes
9216 bytes
52Gbps/ non-blocking
38.7Mpps@64
bytes
12
Page 13
System:
Power (Green)
10/100/1000BASE-T RJ45 Interfaces:
10/100Mbps LNK/ACT (Red) 1000Mbps LNK/ACT (Green)
PoE-in-Use (Amber)
LED Indicators
LCD Monitor (W x D) 40.6 x 30.5 mm, 2-inch
Buttons Menu, Enter, Back, Up and Down
Dimensions
(W x D x H)
Enclosure Metal
Weight 1.8kg 3.4kg 3.5kg
Power Requirements
Power Consumption/ Dissipation
Thermal Fan 1 3
ESD Protection
Surge Protection ±6KV
Power over Ethernet
PoE Standard
PoE Power Supply Type
PoE Power Output
Power Pin Assignment
PoE Power Budget 120 watts 300 watts
1000BASE-X SFP
Interfaces:
10/100Mbps LNK/
ACT (Red)
1000Mbps LNK/
ACT (Green)
180 x 280 x 44mm
(1U height)
AC 100~240V,
50/60Hz, 2.5A max.
Max. 130
watts/446 BTU
Contact discharge of ±6KV DC
IEEE 802.3af Power over Ethernet/PSE
IEEE 802.3at Power over Ethernet Plus/PSE
Per port 52V-54V DC, 300mA. max. 15.4 watts (IEEE 802.3af)
Per port 52V-54V DC, 600mA. max. 30 watts (IEEE 802.3at)
1000BASE-X SFP Interfaces:
LNK/ACT (Green)
233 x 440 x 44 mm
(1U height)
100~240V AC, 50/60Hz, 5A max.
Max. 330watts/1132 BTU
Air discharge of ±8KV DC
End-span
1/2 (+), 3/6 (-)
13
Page 14
Max. Number of
Class 2 PDs
Max. Number of
Class 3 PDs
Max. Number of
Class 4 PDs
Standards Conformance
Regulatory Compliance
Standards Compliance
Environment
Operating
Storage
8 16 24
8 16 23
4 11 11
FCC Part 15 Class A, CE
IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX
IEEE 802.3ab Gigabit 1000BASE-T
IEEE 802.3z Gigabit SX/LX
IEEE 802.3x Flow Control and Back Pressure IEEE 802.3af Power over Ethernet IEEE 802.3at Power over Ethernet Plus
IEEE 802.3az Energy Ecient Ethernet (EEE)
Temperature: -10 ~ 60 degrees C Relative Humidity: 10 ~ 90% (non-condensing)
* Temperature: < 40 degrees C; Humidity: < 90% Temperature: > 40 degrees C; Humidity: < 50%
Temperature: -10 ~ 70 degrees C Relative Humidity: 5 ~ 90% (non-condensing)
14
Page 15
2. Hardware Description
1 3 5 7
9 11 13 15
ACTLNK10/100
17 18
1 3 5 7
9 11 13 15
17 19 21 23
17 18
ACTLNK10/100
These switches provide three dierent running speeds – 10Mbps, 100Mbps and 1000Mbps and automatically distinguish the speed of the incoming connection.
This section describes the hardware features of 802.3at PoE+ Switch. For easier management and control of the 802.3at PoE+ Switch, familiarize yourself with its display indicators and ports. Front panel illustrations in this chapter display the unit LED indicators. Before connecting any network device to the 802.3at PoE+ Switch, please read this chapter carefully.
2.1 Front Panel
The Front Panel of the 802.3at PoE+ Switch consists of 8/16/24 802.3af/at auto-
sensing 10/100/1000Mbps Ethernet RJ45 ports and 2 Gigabit TP/SFP ports. The
LCD monitor and LED Indicators are also located on the front panel of the 802.3at PoE+ Switch.
12
10
11
9
ACTLNK
1 3 5 7109
10/1001000
4 6 82
Mini-GBIC
11 12
GSD-1222VHP
Menu (5 sec)
Enter
Back
Switch Port Information
30.3
---M876
17.6
01 W
M
07 W
----
---M---
-8.3
02 W
M
08 W
----W03---M---
---09---M---
M
15.4W04-10M---
---10---M---
M
----W05---M---M---11---M---
-OFF
---M---
---12223M246
06 -
M
PB:120W TP:72W PD:4
---M---
M
---M-<1
M
M
M
M
M
8-Port 10/100/1000T 802.3at PoE +
Up
2G TP + 2G SFP Ethernet Switch
4 8
2 6
PWR
3 7
1
Down
PoE
PoE-in-Use
5
Figure 2-1: GSD-1222VHP Switch Front Panel
Menu (5 sec)
Enter
Back
Switch Port Information
30.3
---M-33
----
01 W
M
08 W
----
---M---
-8.3
02 W
M
09 W
----W03---M---
----
M
10 W
15.4W04-10M---
-OFF
M
11 -
----W05---M---
----
M
12 W
----
---M---
17.6W13-11M-12
06 W
M
----
---M---
----
07 W
M
14 W
PB:300W TP:72W PD:4
PoE
PWR
PoE
GSW-1820VHP
4 8 12 16
2 6 10 14
3 7 11 15
1
5 9 13
ACTLNK1000
PoE In-Use
SFP
17 18
Up
---M---
M
---M-11
M
---M---
M
---M---
M
---M---
M
M
---M---
M
Down
4 6 82
LNK ACT
12 14 1610
16-Port 10/100/1000T 802.3at PoE 2-Port Gigabit SFP Ethernet Switch
+
SFP
Figure 2-2: GSW-1820VHP Switch Front Panel
Menu (5 sec)
Enter
Back
Switch Port Information
30.3
---M-33
----
01 W
M
08 W
----
---M---
-8.3
02 W
M
09 W
----W03---M---
----
M
10 W
15.4W04-10M---
-OFF
M
11 -
----W05---M---
----
M
12 W
----
---M---
17.6W13-11M-12
06 W
M
----
---M---
----
07 W
M
14 W
PB:300W TP:72W PD:4
Up
---M---
M
---M-11
M
---M---
M
---M---
M
---M---
M
M
---M---
M
Down
GSW-2620VHP
4 8 12 16 20 24
2 6 10 14 18 22
PoE
3 7 11 15 19 23
1
5 9 13 17 21
PWR
PoE
SFP
25 26
ACTLNK1000
PoE In-Use
4 6 82
LNK ACT
12 14 1610
20 22 2418
SFP
Figure 2-3: GSW-2620VHP Switch Front Panel
 Gigabit TP Interface
10/100/1000BASE-T copper, RJ45 twisted-pair: Up to 100 meters.
 Gigabit SFP Slots
1000BASE-SX/LX mini-GBIC slot, SFP (Small Factor Pluggable) transceiver
module: From 550 meters (multi-mode ber) to 10/20/30/40/50/60/70/120 kilo­meters (single-mode ber).
15
Page 16
 Smart LCD
The Smart LCD that is located on the front panel of the GSD-1222VHP, GSW-
1820VHP, GSW-2620VHP 802.3at PoE+ Switch provides “PoE Manage-
ment and Status”, “Switch Mode: Standard, VLAN, Extend”, “Budget and Bandwidth Control”, “Screen Saver”, “Fan Control”, and “Factory Default”.
2.1.1 LCD Monitor Indicators
The 802.3at PoE+ Switch has an LCD monitor designed for network administrator who can easily obtain real-time per PoE port output watts information and system status display, such as over voltage, low voltage, and PoE chipset over temperature
function. The details of each message on the LCD monitor are shown below:
GSD-1222VHP/GSW-1820VHP/GSW-2620VHP LCD Display
Switch Port Information
30.3
---M---
01 W
PD light load protection
PD overload protection
Short-circuit protection
PoE Usage
ULP02---M---
OLP
03
SCP04---M---
----W05---M---
13.6
06 W
14.4
07 W
---M---
---M---
---M---
PB:300W TP:0W PD:3
Power Budget Total PoE
Switch Port Information
----
---M---
01 W
----
---M---
02 W
WARNING
----W03---M---
Main supply voltage
is low
----W04---M---
All ports had shut-
----W05---M---
down.
----
---M---
06 W
----
---M---
07 W
M
M
M
M
M
M
M
----
08 W
----
09 W
----
10 W
----
11 W
----
12 W
----
13 W
----
14 W
---M---
---M---
---M---
---M---
---M---
---M---
---M---
PD:0PB:300W TP:0W
M
M
M
M
M
M
M
Switch Port Information
----
---M---
01 W
----
---M---
02 W
WARNING
----W03---M---
Main supply voltage
is High
----W04---M---
All ports had shut-
----W05---M---
down.
----
---M---
06 W
----
---M---
07 W
Power Low-voltage Protection Power Over-voltage Protection PSE Over-temperature Protection
M
M
M
M
M
M
M
Output
M
M
M
M
M
M
M
----
08 W
----
09 W
-OFF
10 -
----
11 W
----
12 W
----
13 W
----
14 W
----
08 W
----
09 W
----
10 W
----
11 W
----
12 W
----
13 W
----
14 W
877M---
M
---M867
M
---M---
M
---M---
M
---M---
M
---M---
M
---M---
M
Number of PDs
---M---
M
---M---
M
---M---
M
---M---
M
---M---
M
---M---
M
---M---
M
PD:0PB:300W TP:0W
Network traffic
PoE OFF
Switch Port Information
----
---M---
01 W
----
---M---
02 W
WARNING
----W03---M---
The PSE device is too hot!
----W04---M---
All ports had shut-
----W05---M---
down.
----
---M---
06 W
----
---M---
07 W
M
M
M
M
M
M
M
----
08 W
----
09 W
----
10 W
----
11 W
----
12 W
----
13 W
----
14 W
---M---
---M---
---M---
---M---
---M---
---M---
---M---
PD:0PB:300W TP:0W
M
M
M
M
M
M
M
16
Note
1. The LCD screens of the GSD-1222VHP and GSW-1820VHP and GSW-2620VHP are the same, except the number of ports and
port allocation.
2. The LCD screens of the GSD-1222VHP and GSW-1820VHP and GSW-2620VHP will refresh every 15 seconds.
3. For details on LCD Management feature, please refer to “2.3
LCD Management”.
Page 17
 The detailed Smart LCD description of each item is shown below:
Parameters Description
30.3W (example)
OLP
ULP
SCP
OFF
---W It means the port is without a PD device insert.
---M It means this port does not have data transfers.
<1M It means this port data rate transfers less than 1M.
877M
(example)
PB It means power budget.
TB It means total PoE power output information.
PD The number of PDs inserted.
It means the output power port of the PoE switch.
It means the port is overloaded corresponding to the PSE, and the port stops powering.
It means the port corresponding to the PSE is lightly loaded and the port stops powering (When the current on the network is less
than 7.5mA, the PSE thinks the PD has been dialed out and the
port stops powering).
It means the port corresponding to the PSE appears to be short­circuited and the port stops powering.
It means the white and blue OFF shows that the port is blocked by the menu command.
The white and blue character represents the data transmission rate while the red character represents the data transmission rate which is greater than the bandwidth setting, causing power to restart the PSE port. If the resumption situation happens for 10
times within 1 hour, the power supply to the port will be cut o.
2.1.2 LED Indicators
 System
LED Color Function
PWR Green Lights to indicate that the Switch has power.
17
Page 18
 10/100/1000Mbps PoE Ports
LED Color Function
Lights
LNK/ACT Green
Blinks
Lights Indicates the port is providing DC in-line power.
PoE-in-Use Amber
 1000Mbps SFP Slot
LED Color Function
LNK/
Green
ACT
1000 Green Lights Indicates the port is successfully established at 1000Mbps.
 1000Mbps TP Slot (GSD-1222VHP)
LED Color Function
LNK/
10/100 Red Lights
1000 Green Lights
ACT
Green
O
Lights Indicates the port is successfully established at 1000Mbps.
Blinks
Lights
Blinks
Indicates the link through that port is successfully
established at 10/100/1000Mbps.
Indicates that the Switch is actively sending or receiving data over that port.
Indicates the connected device is not a PoE powered device (PD).
Indicates that the Switch is actively sending or receiving data over that port.
Indicates the link through that port is successfully
established at 1000Mbps.
Indicates that the Switch is actively sending or receiving data over that port.
Indicates the port is successfully established at
10/100Mbps
Indicates the port is successfully established at
1000Mbps.
 1000Mbps TP Slot (GSW-1820VHP/GSW-2620VHP)
LED Color Function
LNK/
10/100 Red Lights
1000 Green Lights
ACT
Green
Lights
Blinks
Indicates the link through that port is successfully
established at 1000Mbps.
Indicates that the Switch is actively sending or receiving data over that port.
Indicates the port is successfully established at
10/100Mbps
Indicates the port is successfully established at
1000Mbps.
18
Page 19
2.2 Rear Panel
The rear panel of the 802.3at PoE+ Switch has an AC power socket (100 to 240V AC, 50-60Hz, 2.5/5A).
100-240V AC
50/60Hz, 2.5A
Figure 2-4: GSD-1222VHP Switch Rear Panel
100~240V AC 50/60Hz, 5A max.
Figure 2-5: GSW-1820VHP/GSW-2620VHP Switch Rear Panel
 AC Power Receptacle
For compatibility with electrical outlet standard in most areas of the world, the
802.3at PoE+ Switch’s power supply automatically adjusts to line power in the range of 100-240V AC and 50/60Hz, 2.5/5A.
Plug the female end of the power cord rmly into the receptacle on the rear panel
of the 802.3at PoE+ Switch and the other end into an electrical outlet, and the power will be ready.
Power Notice
The device is a power-required device, which means it will not work till it is powered. If your networks should be active all the
time, please consider using UPS (Uninterrupted Power Supply) for
your device. It will prevent you from network data loss or network downtime. In some areas, installing a surge suppression device may also help to protect your 802.3at PoE+ Switch from being damaged by unregulated surge or current to the Switch or the power adapter.
19
Page 20
2.3 LCD Management
The operation of the 5 buttons (Menu, Enter, Back, Up and Down) on the panel:
Menu (5 sec)
Enter
Back
30.3
01 W
----
02 W
----W03---M---
15.4W04-10M---
----W05---M---
----
06 W
----
07 W
---M867
---M---
---M---
---M---
M
08 W
M
09 W
M
10 W
M
11 -
M
12 W
M
M
14 W
----
---M---
-8.3
---M-<1
----
---M---
-OFF
---M---
----
---M---
17.6W13223M246
----
---M---
M
M
M
M
M
M
M
PB:300W TP:72W PD:4
Press the menu button to switch the “Switch Port Information”.
Press the menu button for about 5 seconds and enter the Main Menu. Choose a menu item by scrolling up and down, and press the “Enter” key to get to the menu item you have chosen. Press the “Back” key to return to the previous menu.
Up
Down
Switch Port Information
20
Page 21
2.3.1 Switch Mode
There are three modes -- “Standard”, “VLAN” and “Extend” – for selection.
Model GSD-1222VHP GSW-1820VHP GSW-2620VHP
Switch
Mode
Standard (default)
VLAN
This mode makes the 802.3at PoE+ Switch operate as a general switch and
all PoE ports operate at 10/100/1000Mbps auto-negotiation.
This mode makes the
GSD-1222VHP operate as
a VLAN isolation switch and
1. Port 1 to port 8 will isolate respectively.
2. Port 1 to port 8 can only communicate with port 9~12 (uplink port).
This mode makes the
GSW-1820VHP operate as
a VLAN isolation switch and
1. Port 1 to port 16 will
2. Port 1 to port 16 can
Function
isolate respectively.
only communicate with
port 17 and port 18
(uplink port).
This mode makes the
GSW-2620VHP operate as
a VLAN isolation switch and
1. Port 1 to port 24 will isolate respectively.
2. Port 1 to port 24 can only communicate with port 25 and port 26 (uplink port).
Extend
With
VLAN
Isolation
This mode makes
the GSD-1222VHP
operate as a VLAN isolation switch and
1. Port 1 to port 8 will isolate respectively.
2. Port 1 to port 8 can only communicate with port 9~12 (uplink port).
3 20-watt PoE transmit
distance of 250m at
speed of 10Mbps.
Table 2-1: GSD/GSW 802.3at PoE+ Switch Description
This mode makes the
GSW-1820VHP operate
as a VLAN isolation switch and
1. Port 1 to port 16 will isolate respectively.
2. Port 1 to port 16 can only communicate with
port 17 and port 18
(uplink port).
3. 20-watt PoE transmit distance of 250m at
speed of 10Mbps.
This mode makes the
GSW-2620VHP operate
as a VLAN isolation switch and
1. Port 1 to port 24 will isolate respectively.
2. Port 1 to port 24 can only communicate with port 25 and port 26 (uplink port).
3. 20-watt PoE transmit distance of 250m at
speed of 10Mbps.
21
Page 22
Standard Mode (default)
Power
Standard
> VLAN
Extend
GSW-1820VHP
Power
> Standard
VLAN
Extend
GSW-1820VHP
100 meters (328 feet)
VLAN Isolation Mode
NVR
Ports 17 and 18 for uplink
1000
Ports 1~16 Access Permitted
Standard
VLAN
> Extend
GSW-1820VHP
PoE IP Camera
PoE
Extend Mode
250 meters (820 feet)
PoE
PoE
PoE
PoE
PoE
IP Camera
IP Camera
IP Camera
PC
1000
PoE
1000BASE-T UTP with PoE
Ports 1 to 16
Access Denied
1000BASE-SX/LX Fiber-optic
1000BASE-T UTP 1000BASE-T UTP with PoE
PoE IP Camera
22
PoE
10BASE-T UTP with PoE
Page 23
VLAN Isolation Feature
The 802.3at PoE+ Switch has one feature called VLAN function. When switching
the mode to the “VLAN” position, port 1 to port 8/16/24 wouldn’t able to communicate with each other.
VLAN 1: P1 P17 P18
Standard
> VLAN
Extend
VLAN 2: P2 P17 P18
VLAN 16: P16 P17 P18
Menu (5 sec)
Enter
Back
Switch Mode
Options:
Standard
VLAN
>
Extend
Up
Down
PoE
PoE
PWR
GSW-1820VHP
4 8 12 16
2 6 10 14
3 7 11 15
5 9 13
1
ACTLNK1000 ACTLNK10/100
PoE In-Use
SFP
17 18
LNK ACT
4 6 82
1 3 5 7
12 14 1610
9 11 13 15
16-Port 10/100/1000T 802.3at PoE 2-Port Gigabit SFP Ethernet Switch
SFP
17 18
+
2.3.2 Budget Control
Due to the power allocation strategy of PSE, when the residual power of PoE is too large, the power distribution of the port can be increased as much as possible by increasing the power trimming of the PSE, so that the utilization of the PSE power supply can be improved. There are four levels of budget control named Unchanged (default), Add 5% PB, Add 10% PB and Add 15% PB.
1. The default PoE budget is 120W/300W in unchanged mode. If you hope to have a full load of over 120W/300W, please select
Add 5% PB, Add 10% PB and Add 15% PB.
Note
2. In order to make sure the PSE power supply is not overloaded for a long time, please try to ensure that TP is less than PB.
23
Page 24
2.3.3 PSE Port Priority
The Priority represents PoE ports priority. There are three levels of power priority
named Low, High and Critical. The priority is used in case the total power
consumption is over the total power budget. In this case the port with the lowest priority will be turned off, and offer power for the port of higher priority. The default port priority is “Low”.
2.3.4 PSE Port Enable
Allows user to disable or enable per port PoE function. The default is “Enable”.
24
Page 25
2.3.5 PD Type
Changing the PoE power-up mode can let non-standard PDs pass the procedures of PoE power delivery process. This way, the switch can supply power to non­standard PDs. The GSD/GSW 802.3at PoE+ Switch series can set the PoE power­up mode to be in Enhance mode, Standard mode or Legacy mode by the user interface.
Object Description
Enhance (default)
Standard Fully conforms to the IEEE 802.3 af/at standard.
Legacy
On the basis of standard mode, change the PD of class 0 to
AT mode; in addition, the current surge limit during power up
increases to the current limit of AT.
The legacy detection is to identify the PD devices that did not follow the IEEE 802.3af standard and their unique electrical signatures, in order for the PoE switch to provide the power to those PD devices.
25
Page 26
2.3.6 Alive Check
The GSD/GSW 802.3at PoE+ Switch series can be congured to monitor connected PD’s status in real time via traffic detection. Once there is no traffic at interval
time, the GSD/GSW 802.3at PoE+ Switch series is going to restart PoE port power, and bring the PD back to work. It will greatly enhance the reliability and reduce administrator management burden.
Object Description
Port Select the port number to enable Alive Check.
Status
Startup Time (60~300s)
Interval Time (60~300s)
Power O
(5~60s)
Allows user to enable or disable per port PD Alive Check function. All ports are disabled as default value.
PD startup time. This startup time is based on determining when to start to
measure the trac. The default startup time is 180 seconds.
Trac detection counter. The switch detects no trac during this time and countdown
for interval time begins and port begins to reboot. The default interval time is 180 seconds.
PoE Port Disable Timer This column allows user to set the PoE device rebooting time.
The default power o time is 5 seconds.
26
Page 27
The PD Alive Check is not a dening standard, so the PoE device on the market doesn’t report reboots done information to the PoE Switch. So user has to make sure how long it takes for the PD to nish booting, and then set the time value
related column. The system is going to check the PD again according to the reboot time. If you cannot make sure the precise booting time, we suggest you set it longer.
Interval Time
No traffic!
Countdown
Power
OFF
Interval Power OFF
Power
ON
Time(s)
PD Traffic=0
StartupPD ready PD Halt
0 180 450 630 635
Startup
Figure 2-4: Alive Check Mechanism
2.3.7 Bandwidth Detection
When the network transmits “the highest data rate”, more than the set value, over a single port, the switch will set off an alarm to warn the overuse of the bandwidth. There are four levels of budget control, namely Unlimited (default), 400Mbps, 500Mbps and 600Mbps.
27
Page 28
2.3.8 Fan Control
Fan control is to achieve the set power with intelligent operation. There are four levels of budget control, namely Always ON, 20% PB (default), 40% PB and 60% PB.
2.3.9 Screen Saver
There are four levels of budget control, namely Always ON, 10min (default), 20min and 30min.
28
Page 29
2.3.10 Language
There are two languages, namely English and Chinese.
2.3.11 Default Setting
Press “Yes” to reset to default.
2.3.12 System
Show the system information.
29
Page 30
3. Hardware Installation
Start up
Please refer to the following for your cabling:
10/100/1000BASE-T
All 10/100/1000BASE-T ports come with Auto-Negotiation capability. They
automatically support 1000BASE-T, 100BASE-TX and 10BASE-T networks. Users
only need to plug a working network device into one of the 10/100/1000BASE-T ports, and then turn on the 802.3at PoE+ Switch. The port will automatically run
at 10Mbps, 20Mbps, 100Mbps or 200Mbps and 1000Mbps or 2000Mbps after the
negotiation with the connected device.
Cabling
Each 10/100BASE-TX port and 10/100/1000BASE-T port uses RJ45 sockets -­similar to phone jacks -- for connection of unshielded twisted-pair cable (UTP).
The IEEE 802.3/802.3u/802.3ab Fast/Gigabit Ethernet standard requires Category
5 UTP for 100Mbps 100BASE-TX. 10BASE-T networks can use Cat.3, 4, 5 or 1000BASE-T uses 5/5e/6 UTP (see table below). Maximum distance is 100 meters
(328 feet).
Port Type Cable Type Connector
10BASE-T Cat.3, 4, 5, 2-pair RJ45
100BASE-TX Cat.5, 5e UTP, 4-pair RJ45
1000BASE-T Cat.5/5e/6 UTP, 4-pair RJ45
Any Ethernet devices like hubs/PCs can connect to the 802.3at PoE+ Switch by
using straight-through wires. The whole 10/100/1000Mbps ports are auto-MDI/ MDI-X that can be used on straight-through or crossover cable.
30
Page 31
3.1 Desktop Installation
To install the 802.3at PoE+ Switch on desktop, simply follow the following steps:
Step 1: Attach the rubber feet to the recessed areas on the bottom of the
802.3at PoE+ Ethernet Switch, as shown in Figure 3-1.
Menu (5 sec)
Enter
Up
G S
W
Back
Figure 3-1: Attaching the Rubber Feet to the 802.3at PoE+ Switch
Step 2: Place the 802.3at PoE+ Switch on desktop near an AC power source.
Step 3: Keep enough ventilation space between the 802.3at PoE+ Switch and the
surrounding objects.
When choosing a location, please keep in mind the environmental restrictions discussed in Chapter 1, Section 4, under Specifications.
Note
Step 4: Connect your 802.3at PoE+ Switch to 802.3af/802.3at complied power
devices (PDs) and other network devices.
A. Connect one end of a standard network cable to the
10/100/1000BASE-T RJ45 ports on the front panel of the 802.3at
PoE+ Switch.
B. Connect the other end of the cable to the network devices such as
printer servers, workstations or routers, etc.
-2620VH P
2
4 8
6 10
PoE
12
14
16 20 24
4 6 82
18 22
Down
1
PWR
3 7
5
PoE
9 13 17 21
1
1
SFP
15 19 23
1000
LNK
LNK
10/100
25
AC
T
26
LNK
AC
PoE
T
In-Use
AC
T
1 3 5 7
12 14 1610
20 22 2418
9 1
1 13 15
SFP
17
19 21 23
17
18
Connection to the Switch requires UTP Category 5, 5e, 6 network cabling with RJ45 tips. For more information, please see the
Note
Cabling Specification in Appendix A.
Step 5: Supply power to the 802.3at PoE+ Switch.
A. Connect one end of the power cable to the 802.3at PoE+ Switch.
B. Connect the power plug of the power cable to a standard wall outlet.
When the 802.3at PoE+ Switch receives power, the Power LED should remain solid Green.
31
Page 32
3.2 Rack Mounting
To install the 802.3at PoE+ Switch in a 19-inch standard rack, follow the instructions described below.
Step 1: Place your 802.3at PoE+ Switch on a hard at surface, with the front
panel positioned towards your front side.
Step 2: Attach a rack-mount bracket to each side of the 802.3at PoE+ Switch
with supplied screws attached to the package. Figure 3-2 shows how to attach brackets to one side of the 802.3at PoE+ Switch.
Menu (5 sec)
Enter
Up
G
S
W
Back
Figure 3-2: Attaching the Brackets to the 802.3at PoE+ Switch.
You must use the screws supplied with the mounting brackets. Damage caused to the parts by using incorrect screws would invali­date the warranty.
Step 3: Secure the brackets tightly.
Step 4: Follow the same steps to attach the second bracket to the opposite side.
Step 5: After the brackets are attached to the 802.3at PoE+ Switch, use suitable
screws to securely attach the brackets to the rack, as shown in Figure 3-3.
-2620VH P
2
4 8 12 16
6
PoE
10 14
4 6 82
18 22
Down
20 24
1
PWR
3 7
5 9 13
PoE
1 1
SFP
15
17 21
19 23
1000
LNK
LNK
10/100
25
AC
T
26
LNK
AC
PoE
T
In-Use
AC
T
12
14 1610
1
3 5 7
20 22 2418
9 1
1
13 15
SFP
17
19 21 23
17
18
Menu (5 sec)
Enter
Up
G
S
W-2
6 2
0
Back
VH
P
2 6
4 8 12 16 20 24
PoE
10 14 18 22
Down
1
PWR
3 7 1
5 9 13 17 21
PoE
4 6 82
1
SFP
15 19 23
LNK1000
LNK
25 26
ACT
LNK10/100
ACT
PoE I
ACT
n-Use
12 14 1610
1
3 5 7
20 22 2418
9 1
1 13 15
17 19 21 23
SFP
17
18
Figure 3-3: Mounting the 802.3at PoE+ Switch in a Rack
Step 6: Proceed with Steps 4 and 5 of session 3.1 Desktop Installation to
connect the network cabling and supply power to your Switch.
32
Page 33
3.3 Installing the SFP Transceiver
The sections describe how to insert an SFP transceiver into an SFP slot of the
802.3at PoE+ Switch. The SFP transceivers are hot-pluggable and hot-swappable. You can plug in and out the transceiver to/from any SFP port without having to power down the 802.3at PoE+ Switch, as the Figure 3-4 shows.
1
2
Figure 3-4: Plugging in the SFP Transceiver
 Approved PLANET SFP Transceivers
PLANET 802.3at PoE+ Switch supports both single mode and multi-mode SFP transceivers. The following list of approved PLANET SFP transceivers is correct at
the time of publication:
Gigabit SFP Transceiver Modules
MGB-Series Module
LC Fiber Cable
MGB-GT
MGB-SX
MGB-LX
MGB-L30
MGB-L50
MGB-L70
MGB-L120
MGB-LA10
MGB-LB10
MGB-LA20
MGB-LB20
MGB-LA40
MGB-LB40
SFP-Port 1000BASE-T Module
SFP-Port 1000BASE-SX mini-GBIC module - 550m
SFP-Port 1000BASE-LX mini-GBIC module - 10km
SFP-Port 1000BASE-LX mini-GBIC module - 30km
SFP-Port 1000BASE-LX mini-GBIC module - 50km
SFP-Port 1000BASE-LX mini-GBIC module - 70km
SFP-Port 1000BASE-LX mini-GBIC module - 120km
SFP-Port 1000BASE-LX (WDM,TX:1310nm) - 10km
SFP-Port 1000BASE-LX (WDM,TX:1550nm) - 10km
SFP-Port 1000BASE-LX (WDM,TX:1310nm) - 20km
SFP-Port 1000BASE-LX (WDM,TX:1550nm) - 20km
SFP-Port 1000BASE-LX (WDM,TX:1310nm) - 40km
SFP-Port 1000BASE-LX (WDM,TX:1550nm) - 40km
33
Page 34
It is recommended to use PLANET SFP on the 802.3at PoE+ Switch. If you insert an SFP transceiver that is not supported, the
Note
802.3at PoE+ Switch will not recognize it.
1. Before we connect the 802.3at PoE+ Switch to the other network device, we have to make sure both sides of the SFP transceivers are with the same media
type, for example, 1000BASE-SX to 1000BASE-SX; 1000BASE-LX to 1000BASE­LX.
2. Check whether the ber-optic cable type matches with the SFP transceiver
requirement.
To connect to 1000BASE-SX SFP transceiver, please use the multi-mode ber
cable with one side being the male duplex LC connector type.
To connect to 1000BASE-LX SFP transceiver, please use the single-mode ber
cable with one side being the male duplex LC connector type
 Connect the Fiber Cable
1. Insert the duplex LC connector into the SFP transceiver.
2. Connect the other end of the cable to a device with SFP transceiver installed.
3. Check the LNK/ACT LED of the SFP slot on the front of the 802.3at PoE+
Switch. Ensure that the SFP transceiver is operating correctly.
 Remove the Transceiver Module
1. Make sure there is no network activity anymore.
2. Remove the Fiber-Optic Cable gently.
3. Lift up the lever of the MGB module and turn it to a horizontal position.
4. Pull out the module gently through the lever, as the Figure 3-5 shows.
34
MGB-SX/LX
1
2
Figure 3-5: How to Pull Out the SFP Transceiver
Page 35
Never pull out the module without lifting up the lever of the module and turning it to a horizontal position. Directly pulling out the module could damage the module and the SFP module slot of
Note
the 802.3at PoE+ Switch.
3.4 Product Applications
Department/Workgroup PoE Switch:
Providing 8/16/24 PoE in-line power interfaces, the 802.3at PoE+ Switch can easily build a power that centrally controls IP phone system, IP camera system and wireless AP group for enterprises. Cameras can be installed around the corner in the company or campus for surveillance demands. Without the power-socket limitation, the 802.3at PoE+ Switch makes the installation of cameras easier and
more ecient.
Laptop
N
DC
802.3af Splitter
PoE VoIP ATA
PC Group
PC Group
PoE
N
PoE Wireless AP
PoE
PoE
PoE VoIP Phone
GSW-1820VHP
PoE
GSW-2620VHP
PoE
DC
Power Line (DC)
100BASE-TX UTP
1000
1000BASE-SX/LX Fiber-optic
PoE
1000BASE-TX UTP with PoE
Telephone wire
N
2.4GHz 802.11n
PoE IP Camera
Camera
Phone
Figure 3-6: Department/Workgroup 802.3at PoE+ Switch Connection
1000
Core Switch
1000
35
Page 36
3.5 Power over Ethernet Powered Devices
Voice over IP Phones
As many as PoE VoIP phones, ATAs and other Ethernet/ non-Ethernet end-devices can be installed, but UPS is
3~5 watts
6~12 watts
10~12 watts
3~12 watts
3~25 watts
needed for uninterrupted power system and power control system.
Wireless LAN Access Points
Access points can readily be installed in museums, sightseeing sites, airports, hotels, campuses, factories and warehouses.
IP Surveillance
For the sake of security, install IP cameras around enterprises, museums, campuses, hospitals and bank without considering location and electrical outlets.
PoE Splitter
As PoE Splitter splits the PoE 48V DC over the Ethernet cable into 5/12V DC power output, network deployments
can easily be made without worrying about power outlet locations, thus eliminating the costs for additional AC wiring and reducing the installation time.
High Power PoE Splitter
As PoE Splitter splits the PoE 53V-54V DC over the Ethernet cable into 24/12V DC power output, network
deployments can easily be made without worrying about power outlet locations, thus eliminating the costs for additional AC wiring and reducing the installation time.
36
30 watts
Note
High Power Speed Dome
This state-of-the-art design ts very nicely in various network environments like trac centers, shopping malls,
railway stations, warehouses, airports and production facilities for the most the demanding outdoor surveillance applications. Electrician is not needed to install AC sockets.
Since each port of the 802.3at PoE+ Switch supports 52-54V DC PoE power output, please make sure the PD’s acceptable DC power range is from 52-54V DC. Otherwise, it will damage the PD.
Page 37
4. Power over Ethernet Overview
What is PoE?
PoE is an abbreviation of Power over Ethernet. The PoE technology means a
system safely transmits both power and data on Ethernet UTP cable. The IEEE
standard for PoE technology requires Category 5 cable or higher for high power PoE levels, but can operate with Cat3 cable for low power levels. Power is supplied
in common mode over two or more of the dierential pairs of wires found in the
Ethernet cables and comes from a power supply within a PoE-enabled network
device such as an Ethernet switch or can be injected into a cable run with a mid-
span power supply.
The original IEEE 802.3af-2003 PoE standard provides up to 15.4W of DC power
(minimum 44V DC and 350mA) to each device. Only 12.95W is assured to be
available at the powered device as some power is dissipated in the cable.
The updated IEEE 802.3at-2009 PoE standard, also known as PoE+ or PoE plus, provides up to 25.5W of power. The 2009 standard prohibits a powered device from using all four pairs for power.
The 802.3af/802.3at denes two types of source equipment: mid-span and end-
span.
Mid-span
Mid-span device is placed between legacy switch and the powered device. Mid-span taps the unused wire pairs 4/5 and 7/8 to carry power; the other four are for data
transmission.
End-span
End-span device is directly connected with powered device. End-span could also tap the wire 1/2 and 3/6.
PoE System Architecture
The specication of PoE typically requires two devices: the Powered Source
Equipment (PSE) and the Powered Device (PD). The PSE is either an end-span or a mid-span, while the PD is a PoE-enabled terminal, such as IP phones, wireless LAN, etc. Power can be delivered over data pairs or spare pairs of standard Cat5 cabling.
Powered Source Equipment (PSE)
Power sourcing equipment (PSE) is a device such as a switch that provides (sources) power on the Ethernet cable. The maximum allowed for continuous
output power per cable in IEEE 802.3af is 15.4W. A later specication, IEEE
802.3at, oers 25.50W. When the device is a switch, it is commonly called an
end-span (although IEEE 802.3af refers to it as endpoint). Otherwise, if it is an
37
Page 38
intermediary device between a non-PoE capable switch and a PoE device, it is
called a mid-span. An external PoE injector is a mid-span device.
Powered Device
A powered device (PD) is a device powered by a PSE and thus consumes energy.
Examples include wireless access points, IP phones, and IP cameras. Many
powered devices have an auxiliary power connector for an optional, external power supply. Depending on the PD design, some, none, or all power can be supplied from the auxiliary port, with the auxiliary port sometimes acting as backup power in case of PoE supplied power failure.
How Power is Transferred through Cable
A standard Cat5 Ethernet cable has four twisted pairs, but only two of these are
used for 10BASE-T and 100BASE-TX. The specication allows two options for using these cables for power, shown in Figure 1 and Figure 2:
The spare pairs are used. Figure 1 shows the pair on pins 4 and 5 connected
together and forming the positive supply, and the pair on pins 7 and 8 connected
and forming the negative supply. (In fact, a late change to the spec allows either polarity to be used).
38
POWER SOURCING EQUIPMENT (PSE)
4
5
1
+
48V
TX
-
RX
Figure 1: Power Supplied over Spare Pins
2
3
6
7
8
SPARE PAIR
SIGNAL PAIR
SIGNAL PAIR
SPARE PAIR
POWERED DEVICE (PD)
4
5
1
RX
2
3
6
7
8
TX
DC / DC
Converter
Converter
Page 39
The data pairs are used. Since Ethernet pairs are transformers coupled at each end, it is possible to apply DC power to the center tap of the isolated transformer without upsetting the data transfer. In this mode of operation, the pair on pins 3 and 6 and the pair on pins 1 and 2 can be of either polarity.
POWER SOURCING EQUIPMENT (PSE)
+ / -
TX
/
-
+
48V
RX
4
5
1
2
3
6
7
8
SPARE PAIR
SIGNAL PAIR
SIGNAL PAIR
SPARE PAIR
POWERED DEVICE (PD)
4
5
1
RX
2
3
6
7
8
DC / DC
Converter
TX
Figure 2: Power Supplied over Data Pins
When to install PoE
Consider the following scenarios:
z You’re planning to install the latest VoIP phone system to minimize cabling
building costs when your company moves into a new oce next month.
z The company sta has been clamoring for a wireless access point in the picnic
area behind the building so they can work on their laptops through lunch, but
the cost of electrical power to the outside is not aordable.
z Management asks for IP Surveillance Cameras and business access systems
throughout the facility, but they would rather avoid another electrician’s
payment.
39
Page 40
5. Troubleshooting
This chapter contains information to help you solve issues. If the 802.3at PoE+ Switch is not functioning properly, make sure the 802.3at PoE+ Switch was set up according to instructions in this manual.
The Link LED is not lit.
Solution:
Check the cable connection and also try to swap one new cable.
1000BASE-T port link LED is lit, but the trac is irregular.
Solution:
Make sure the attached device is not set to full duplex. Some devices use a
physical or software switch to change duplex modes. Auto-negotiation may not recognize this type of full-duplex setting.
Why the Switch doesn’t connect to the network.
Solution:
Check the LNK/ACT LED on the 802.3at PoE+ Switch. Try another port on the
802.3at PoE+ Switch. Make sure the cable is installed properly. Make sure the
cable is the right type. Turn o the power. After a while, turn on the power again.
Why the GSD/GSW Switch, connected to PoE device, cannot be powered on.
Solution:
1. Please check the cable type of the connection from GSD/GSW switch to the
other end. The cable should be an 8-wire UTP, Category 5 or above and EIA568
cable within 100 meters. A cable with only 4-wire, short loop or over 100 meters
will aect the power supply.
2. Please make sure the device is fully complied with IEEE 802.3af/IEEE 802.3at
standard.
What is the power output of each PoE port?
Solution:
1. Each PoE port supports 52-54V DC, 600mA and a maximum of 30 watts of
power output. Detect and inject by the standard of IEEE 802.3at.
2. Each PoE port supports 52-54V DC, 300mA and a maximum of 15.4 watts
of power output. Detect and inject by the standard of IEEE 802.3af.
40
Page 41
Appendix A Networking Connection
A.1 Switch's Data RJ45 Pin Assignments - 1000Mbps, 1000BASE-T
PIN NO MDI MDI-X
1 BI_DA+ BI_DB+
2 BI_DA- BI_DB-
3 BI_DB+ BI_DA+
4 BI_DC+ BI_DD+
5 BI_DC- BI_DD-
6 BI_DB- BI_DA-
7 BI_DD+ BI_DC+
8 BI_DD- BI_DC-
Implicit implementation of the crossover function within a twisted-pair cable, or at a wiring panel, while not expressly forbidden, is beyond the scope of this standard.
A.2 10/100Mbps, 10/100BASE-TX
When connecting Switch to another Fast Ethernet switch, a straight-through or
crossover cable might be necessary. Each port of the Switch supports auto-MDI/ MDI-X detection, meaning you can directly connect the Switch to any Ethernet
devices without making a crossover cable. The following table and diagram show
the standard RJ45 receptacle/connector and their pin assignments:
RJ45 Connector Pin Assignment
Contact
1 Tx + (transmit) Rx + (receive)
2 Tx - (transmit) Rx - (receive)
3 Rx + (receive) Tx + (transmit)
4, 5 Not used
6 Rx - (receive) Tx - (transmit)
7, 8 Not used
Media Dependent Interface
MDI
Media Dependent Interface - Cross
MDI-X
41
Page 42
The standard cable, RJ45 pin assignment
The standard RJ45 receptacle/connector
There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The
following shows the pin allocation and color of straight-through cable and crossover
cable connection:
Straight Cable
12345678
12345678
Crossover Cable
12345678
12345678
SIDE 1
SIDE 2
SIDE 1
SIDE 2
SIDE 1
1 = White/Orange 2 = Orange 3 = White/Green 4 = Blue 5 = White/Blue 6 = Green 7 = White/Brown 8 = Brown
SIDE 1 SIDE 2
1 = White/Orange 2 = Orange 3 = White/Green 4 = Blue 5 = White/Blue 6 = Green 7 = White/Brown 8 = Brown
SIDE 2
1 = White/Orange 2 = Orange 3 = White/Green 4 = Blue 5 = White/Blue 6 = Green 7 = White/Brown 8 = Brown
1 = White/Green 2 = Green 3 = White/Orange 4 = Blue 5 = White/Blue 6 = Orange 7 = White/Brown 8 = Brown
Figure A-1: Straight-through and Crossover Cable
Please make sure your connected cables are with the same pin assignment and color as the above picture before deploying the cables into your network.
42
Page 43
Taiwan
Nov. 29th, 2018
.
Place
Date
Legal Signature
EC Declaration of Conformity
For the following equipment:
*Type of Product : 8-Port 10/100/1000T 802.3at PoE + 2-Port 10/100/1000T + 2-Port 1000X SFP
*Model Number : GSD-1222VHP
* Produced by:
Manufacturer‘s Name : Planet Technology Corp. Manufacturer‘s Address : 10F., No.96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan
is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive 2014/30/EU.
For the evaluation regarding the EMC, the following standards were applied:
EN 55032 2015+AC:2016 Class A AS/NZS CISPR 32 2015 Class A
EN 55035 2017 EN 60950-1 2006+A11:2009+A1:2010+A12:2011+A2:2013
Responsible for marking this declaration if the:
Manufacturer
Authorized representative established within the EU (if applicable):
Company Name: Planet Technology Corp.
Company Address: 10F., No.96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan
Person responsible for making this declaration
Name, Surname Jonas Yang
Position / Title : Product Manager
Ethernet Switch with PoE LCD Monitor
EN 61000-3-2 2014 Class A EN 61000-3-3 2013
Authorized representative established within the EU
PLANET TECHNOLOGY CORPORATION
10F., No.96, Minquan Rd., Xindian Dist., New Taipei City, Taiwan
e-mail: sales@planet.com.tw http://www.planet.com.tw
Tel:886-2-2219-9518 Fax:886-2-2219-9528
Page 44
Taiwan
Dec 18th, 2017
.
Place
Date
Legal Signature
EC Declaration of Conformity
For the following equipment:
*Type of Product : 16/24-Port 10/100/1000T 802.3at PoE + 2-Port Gigabit SFP Ethernet Switch with
*Model Number : GSW-1820VHP, GSW-2620VHP
* Produced by:
Manufacturer‘s Name : Planet Technology Corp. Manufacturer‘s Address : 10F., No.96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan
is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive 2014/30/EU.
For the evaluation regarding the EMC, the following standards were applied:
EN 55032 2015 Class A AS/NZS CISPR 32 2015
EN 55024 2010+A1:2015
Responsible for marking this declaration if the:
Manufacturer
Authorized representative established within the EU (if applicable):
Company Name: Planet Technology Corp.
Company Address: 10F., No.96, Minquan Rd., Xindian Dist., New Taipei City 231, Taiwan
Person responsible for making this declaration
Name, Surname Jonas Yang
Position / Title : Director
LCD PoE Monitor (300W)
EN 61000-3-2 2014 Class A EN 61000-3-3 2013
Authorized representative established within the EU
PLANET TECHNOLOGY CORPORATION
10F., No.96, Minquan Rd., Xindian Dist., New Taipei City, Taiwan
e-mail: sales@planet.com.tw http://www.planet.com.tw
Tel:886-2-2219-9518 Fax:886-2-2219-9528
Loading...