1. Overview
2. Introduction
Thank you for purchasing PLANET 75-watt DC power supply for
GPL-8000.
Power Supply Unit Input Range
GPL-PWR75-DC -36 to -72V DC
Open the box of the Redundant Power Supply unit and carefully
unpack it. The box should contain the following items:
The DC Power Supply unit x 1
User’s Manual x 1
If any item is found missing or damaged, please contact your local
reseller for replacement.
Before installation, please be sure to read this user’s manual
carefully to complete the correct installation of GPL-PWR75-DC
Power Supply Unit. This manual shows how to quickly install the
power in the GPL-8000.
The following gure shows the front panel of the GPL-PWR75-DC.
Figure 2-1 GPL-PWR75-DC Front View
– 1 – – 2 –
3. Installing Redundant Power Supply
Unit
The GPL-PWR75-DC is hot-swappable, so there is no
need to power off the GPON OLT before installing or
Note
Follow these steps to install the redundant power in the GPON OLT:
1. Place the GPON OLT on a at surface. Use a screwdriver to
unscrew screws on both sides of the blank plate to remove the
blank plate. Do not discard the blank plate as it can be used
again when removing the power supply unit from the GPON OLT.
removing the power supply unit.
1
Figure 3-1 Removing the Blank Plate
1
2
2. Install the redundant power by sliding the power supply unit into
the compartment.
1
2
Figure 3-2 Sliding the Power Supply Unit into the Compartment
3. Next, tighten the thumbscrews on both sides.
Figure 3-3 Tightening the GPL-PWR75-DC
Please make sure that the power source must be
turned off before plugging in the power supply to
Caution
avoid device damage.
2
– 3 – – 4 –
4. Wiring the DC Power Input
The 3-pin terminal block connector on the redundant power uses DC
power input. Please follow the steps below to insert the power wire.
1. Before connecting the DC power wires, please
check whether your local DC power source is
stable.
Note
2. The wire gauge for the power cable should be in
the range of 12 ~ 24 AWG.
3. The DC power input range is -36 ~ -72V DC.
5. Removing Redundant Power Supply
Unit
Follow these steps to remove the redundant power from the GPON
OLT:
1. Remove all DC power wires from the terminal block of the
GPL-PWR75-DC.
2. To remove the redundant power from the GPL-8000, loosen the
thumbscrews on both sides and pull it out.
1. Insert the positive DC power wire into the positive(+) contact
(left pin) and tighten the wire-clamp for preventing the DC power
wire from loosening.
2. Insert the negative DC power wire into the negative(-) contact
(middle pin) and tighten the wire-clamp for preventing the DC
power wire from loosening.
3. Insert the grounding power wire into the grounding(G) contact
(right pin) and tighten the wire-clamp for preventing the power
wire from loosening.
Figure 4-1 Power Pin Design of GPL-PWR75-DC
– 5 – – 6 –
1
1
2
Figure 5-1 Removing the GPL-PWR75-DC