PLANET FT-80x User Manual [en, fr, de, ru, es]

Table of Contents
English
1. Product Features ..........................................................................................................................................................................................................1-1
2. Checklist .............................................................................................................................................................................................................................1-1
3. Product Outlook........................................................................................................................................................................................................... 1-2
4. Link Fault Pass Through (LFP) .............................................................................................................................................................................1-3
5. Installing The Converter .........................................................................................................................................................................................1-3
6. Duplex Mode Support ............................................................................................................................................................................................1-4
7. LED Indication ............................................................................................................................................................................................................... 1-5
8. Cable Connection Parameter ............................................................................................................................................................................. 1-6
9. Product Specication ...............................................................................................................................................................................................1-7
Française
1. Les Caracteristiques Du Produit ....................................................................................................................................................................... 2-1
2. L'aide-Mémoire .............................................................................................................................................................................................................2-1
3. Le Produit .......................................................................................................................................................................................................................... 2-2
4. Link Fault Pass Through (LFP) .............................................................................................................................................................................2-3
5. L’installation Du Convertisseur ........................................................................................................................................................................... 2-3
6. Le Maintien Du Mode Duplex ........................................................................................................................................................................... 2-4
7. L’indication Del ..............................................................................................................................................................................................................2-5
8. Les Parametres De La Connexion Des Cables .......................................................................................................................................2-6
9. Les Specications Du Produit ............................................................................................................................................................................ 2-7
Deutsch
1. Produkt Eigenschaften ............................................................................................................................................................................................3-1
2. Checkliste ..........................................................................................................................................................................................................................3-1
3. Produkt Erscheinung ................................................................................................................................................................................................3-2
4. Link Fault Pass Through (LFP) Verbindungsfehler-Durchreiche ................................................................................................3-3
5. Installierung Des Konverters ............................................................................................................................................................................... 3-3
6 Duplex Modus Unterstützung ........................................................................................................................................................................... 3-4
7. LED Anzeige ....................................................................................................................................................................................................................3-5
8 Kabel Verbindungsparameter .......................................................................................................................................................................... 3-6
9. Produkt Spezikation................................................................................................................................................................................................ 3-7
Pусский
Português
Español
1. Product Features
Note
FT-80x Fast Ethernet Media Converter:
Comply with IEEE 802.3/802.3u, 10/100Base-TX, 100Base-FX Standard l
Data Transfer Rate: TP - 10/100Mbps; FX - 100Mbps l
Duplex mode support: l
- Full or half-duplex mode by Auto-Negotiation (Twisted Pair port)
- Full or half-duplex mode by DIP-switch (Fiber port)
DIP-switch: 2 DIP-switches; FX duplex mode selection & l LFP mode selection
Compliance with PLANET’s 10”/19” Media Converter Chassis l
GT-80x Gigabit Ethernet Media Converter:
Comply with IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX, IEEE 802.3ab 1000Base-T, IEEE 802.3z l 1000Base-SX/LX standard
Data Transfer Rate: TP – 10/100/1000Mbps; FX – 1000Mbps l
DIP switch for l LFP function (Disable / Enable) setting
OAM (TS-1000 and IEEE 802.3ah) supported l
9K Jumbo frame supported l
Compliance with PLANET’s 10”/19” Media Converter Chassis l
In the following sections, the term "FT-80x / GT-80x" indicates the product family above, the term "MM" and "SM" represent Multi-Mode and Single Mode ber-optic mode.
2. Checklist
Your FT-80x / GT-80x carton should contain the following items:
The Fast / Gigabit Ethernet Media Converter n
AC-DC Power Adapter (Output: 5V DC, 2A max.) n
This User’s Manual n
If any item is missing or damaged, please consult the dealer from whom you purchased your Fast / Gigabit Ethernet Media Converter.
English
GT-805A is with one vacant SFP module slot. The mini GBIC SFP module is not bundled with in the package.
1-1
Fast Ethernet Bridge 10/100Base-TX to 100Base-FX
TX RX
FX TX
100PWR
FDX/ COL
LNK/ ACT
Gigabit Ethernet Converter 10/100/1000Base-T to 1000Base-SX/LX
TX RX
LNK
ACT
PWR 1000
LFP
OFF
ON
TPFiber
LNK /ACT
Gigabit Ethernet Converter 10/100/1000Base-T to 1000Base-SX/LX
Mini-GBIC
LNK
ACT
PWR 1000
LFP
OFF
ON
TPFiber
LNK /ACT
Gigabit Ethernet Converter 10/100/1000Base-T to 1000Base-LX
WDM
LNK
ACT
PWR 1000
LFP
OFF
ON
TPFiber
LNK /ACT
FX Duplex
HDX FDX
5V DC
+
English
3. Product Outlook
Right View (FT-80x)
There are one RJ-45 Twisted-Pair jack (Auto-MD I /MDI-X), one ber-optic connector (var y by model) and six LED indicators.
Figure 1: FT-80x Right View
Right View (GT-80x)
There are one RJ-45 Twisted-Pair jack (Auto-MDI/MDI-X), one ber-optic connector (vary by model) and four LED indicators. Also One DIP switch for Link-Fault -Ppassthrough (LFP) feature, "ON" to turn-on the LLCF and LLR detection. And "OFF" to turn o the feature. Please refer to the following sections for more.
Figure 2: GT-802/802S Right View
Figure 3: GT-805A Right View
Left View (FT-80x)
One DC 5V power socket and one DIP switch for Fiber-optic operating mode selection, FDX for full­duplex, and HDX for half-duplex.
1-2
Figure 4: GT-806A15/B15/A60/B60 Right View
Figure 5: FT-80x Left View
Left View (GT-80x)
5V DC
+
OFF ON
LFP
Note
The rear panel of the Gigabit Ethernet Media Converter indicates one DC jack, which accepts input power with 5V DC 2A.
Figure 6: GT-80x Left View
Side View (FT-80x)
One DIP switch for Link Fault Pass Through (LFP) feature, "ON" to turn-on the LLCF and LLR detection. And "OFF" to turn –o this feature. Please refer to the following sections for more.
Figure 7: FT-80x Side View
4. Link Fault Pass Through (LFP)
The LFP function includes the Link-Fault-Passthrough function (LLCF/LLR) and the DIP Switch design. LLCF/ LLR can immediately alarm administrators the problem of the link media and provide ecient solution to monitor the network. The DIP Switch will disable or enable the LFP function.
LLCF (Link Loss Carry Forward) means when a device connected to the converter and the TP line loss the link, the converter’s ber will disconnect the link of transmit. LLR (Link Loss Return) means when a device connected to the converter and the ber line loss the link, the converter’s ber will disconnect the link of transmit.
LFP function is ON by default setting. If you are familiar with the network installation and for diagnostic purpose (i.e. check which end is broken), you can turn it off and reset the converter to make it take effect. Otherwise, please remain it in the default position.
5. Installing The Converter
To install FT-80x / GT-80x stand-alone, on a desktop or shelf, simply complete the following steps:
Step 1: Turn o the power of the device/station in a network to which the FT-80x / GT-80x will be
attached.
Step 2: Attach ber cable from the FT-80x / GT-80x to the ber network. TX, RX must be paired at both
ends.
1-3
Step 3: Attach a Cat. 5/5e/6 UTP cable from the 10/100Base-TX or 10/100/1000Base-T network to the
RX
TX
FT-80X
TX RX
10/100Base-TX Cat.5/5e TP Cable Network
100Base-FX Fiber Network
RX
TX
GT-80X
TX RX
10/100/1000Base-T Cat.5/5e/6 TP Cable Network
1000Base-SX/LX Fiber Network
Note
RJ-45 port on the FT-80x / GT-80x.
Step 4: Connect the 5VDC power adapter to the FT-80x / GT-80x and verify that the Power LED lights
up.
Step 5: Turn on the power of the device/station, the TX Link and FX Link LEDs should light when all
cables are attached.
Figure 8: FT-80x Installation
Figure 9: GT-80x Installation
1. It is recommends using PLANET MGB-SX / MGB-LX series 1000Base-SX/LX SFP on the GT-805A. If you insert a SFP transceiver that is not supported, the GT-805A will not recognize it.
2. Please check the link-budget of your SFP transceivers and its physical wiring distance, in some installation, a in-line optical attenuator may be required to protect your transceivers.
6. Duplex Mode Support
The FT-80x TP port supports duplex mode detection by auto-negotiation (A-N). It shall auto detects the link speed and the duplex mode by default. And auto fall-back to 100 or 10Mbps half-duplex mode with its link partner. The ber port supports DIP switch selection for Full-duplex (default) or Half-duplex.
The GT-80x TP port supports triple speed - 10/100/1000Base-T, Auto-negotiation. It shall auto detects the link speed and the duplex mode by default with its link partner. The Fiber port - 1000Base-SX/LX, allow 1000Mbps full duplex by Auto-Negotiation. Please also check the setting of the link partner as well.
1-4
7. LED Indication
FT-80x:
LED Color Description
FX LNK / ACT Green
TX LNK / ACT Green
FX FDX / COL Green
TX FDX / COL Green
100 Green
PWR Green Lit: when +5VDC power detected.
GT-80x:
LED Color Description
PWR Green Lit: When +5V DC power detected.
Fiber LNK/ACT Green
TP LNK/ACT Green
TP 1000 Green
Blinks: when any FX packets transmitting and receiving.
Lit: when Fiber connection is good.
Blinks: when any TP packets transmitting and receiving.
Lit: when TP connection is good.
Lit: when Full-duplex mode is enabled in FX port.
Blinks: when FX port is in half-duplex mode and receives collision.
Lit: when Full-duplex mode is enabled (detect by Auto-Negotiation) in TP port.
Blinks: when TP port receive collision.
Lit: when the TP port runs in 100Mbps.
Remains o while LINK LED lit represent the TP port runs in 10Mbps.
Lit: To indicate the link through ber por t is successfully established.
Blink: Indicate the ber port is actively sending or receiving data.
Lit: To indicate the link through TP port is successfully established.
Blink: Indicate the port is actively sending or receiving data.
Lit: When the port runs in 1000Mbps line speed.
O: When the port runs in 10/100Mbps.
1-5
8. Cable Connection Parameter
Note
Cables:
Standard (Wavelength) 100Base-FX (1310nm) 1000Base-SX (850nm) 1000Base -LX (1310nm)
Fiber Type & Cable Specication
FT-80x:
The wiring details are as below: Wiring distance:
Duplex Connection Limitation (max.)
Twisted Pair
Half / Full
Multi-Mode Converters
MM Half
MM Full
Single-Mode Converters* (FT-80xynn; x= 2, 6; y= S, A, B; nn=km)
SM Full
GT-80x:
Wiring Distances:
Standard Fiber Diameter (micron) Bandwidth (MHz x km) Max. Distance (meters)
1000Base-SX MM
1000Base-LX
Multi-mode 50/125μm or 62.5/125μm
Single-mode 9/125μm
Node to Node Node to Switch/Hub
Node to Node Node to Switch
Node to Node Node to Switch
Node to Node Node to Switch
62.5 50
62.5
MM
50
SM 9 N/A 5000*
100 500
5 5
100 meters
412 meters
2 kilometers
Depends on model
220 550
550
The Single-mode port (1000Base-LX port) of GT-802S, GT-805A, GT-806A15/B15 and GT-806A60/B60 is complied with LX 5 kilometers and provides additional margin allowing for a 10 / 15 / 60 kilometers Gigabit Ethernet link (max. 120k m) on single mode fiber.
1-6
9. Product Specication
Note
FT-80x
Model FT-801 FT-802 FT-802S15 FT-802S35 FT-802S50
Fiber Connector ST SC SC SC WDM
Fiber Mode Multi-mode Single-mode
Fiber Maximum Distance 2km 15km 35km 50km 20km
Copper Connector 10/100Mbps RJ-45
Copper Modes Full Duplex, auto-negotiation
Packet Forwarding Rate (64bytes)
DIP switch LFP Disable / Enable; FX Full / Half-duplex
Protocols and Standards
Dimensions 97 x 69 x 26 mm (W x D x H)
Weight 0.2kg
Power 5VDC, 2A max.
Emission FCC, CE
Temperature Operating: 0 ~ 50°C / Storage: -40 ~ 70°C
Humidity 5% ~ 95% non-condensing
Installation Wall mount, DIN-Rail, Chassis Installation
1. Please note FT-806A20/806B20 is designed to work together. It means you must
2. The FT-802xxx / FT-806xxx series single mode Media Converter provide long
3. Connecting to the Fast Ethernet products, please refer to the device’s Technical
4. Consult your dealer for DIN-Rail or Chassis installation.
14880pps @10Mbps; 148810pps @100Mbps
IEEE 802.3, 10Base-T IEEE 802.3u, 100Base-TX, 100Base-FX
connect FT-806A20 to FT-806B20 in pair. If both ends are FT-806A20 (or FT-806B20), or any above model to any 3rd party device, they can’t work normally and may damage the fiber connectors.
distance support from 15 km to 50km. When shorter distance of single-mode fiber cable is used, you might need to insert an in-line optical attenuator in the link to avoid overloading of the receiver.
Manual.
FT-806A20 FT-806B20
1-7
GT-80x
Model GT-802 GT-802S GT-805A
Fiber Connector SC-type connector SFP, LC type SC-type connector (WDM) LX
Fiber Mode Multi-mode Single mode
Fiber Maximum Distance
Copper Connector 10/100/1000Mbps RJ-45
Copper Modes Full Duplex, auto-negotiation
Packet Forwarding Rate (64bytes)
DIP switch LFP Disable / Enable
Protocols and Standards
OAM TS-1000, IEEE 802.3ah terminal
Jumbo Packet Size 9K
Dimensions 26 x 70 x 97mm (H x W x D)
Power 5VDC, 2A max.
Emission FCC CE
Temperature Storage: -10 ~ 70°C / Operating: 0 ~ 50°C
Humidity 5% ~ 90% non-condensing
Installation Wall mount, DIN-Rail, Chassis Installation
220m / 550m 10km
14880pps @10Mbps / 148810pps @100Mbps / 1488000pps @1000Mbps
IEEE 802.3 10Base-T IEEE 802.3u 100Base-TX IEEE 802.3ab 1000Base-T IEEE 802.3z 1000Base-SX/LX
Vary on module
Vary on module
GT-806A15 GT-806B15
15km 60km
GT-806A60 GT-806B60
Single mode
1-8
Note
1. Please note GT-806A15/806B15 and GT-806A60/806B60 is designed to work together. It means you must connect GT-806A15 to GT-806B15 or GT-806A60 to GT-806B60 in pairs. If both ends are GT-806A15 or GT-806A60 and GT-806B15 or GT-806B60, or any above model to any 3rd party device, they can’t work normally and may damage the fiber connectors.
2. The GT-802S / GT-806xxx series single mode Media Converter provide long distance support from 10 km to 60km. When shorter distance of single-mode fiber cable is used, you might need to insert an in-line optical attenuator in the link to avoid overloading the receiver:
3. Connecting to the Gigabit Ethernet products, please refer to the device’s Technical Manual.
4. Consult your dealer for DIN-Rail or Chassis installation.
1-9
This page is intentionally left blank
1. Les Caracteristiques Du Produit
La note
FT-80x Le convertisseur des médias Fast Ethernet:
Conforme aux normes IEEE 802.3/802.3u, 10/100Base-TX, 100Base-FX l
Le taux de transfert des données: TP - 10/100Mbps; FX - 100Mbps l
Le maintien du mode duplex: l
- Le mode plein- ou semi-duplex par l'Auto-Négociation (Le port-paire détourné)
- Le mode plein- ou semi-duplex par le commutateur DIP (le port à bre)
Le commutateur DIP: 2 commutateurs DIP; la sélection du mode duplex FX & la sélection du mode LFP l
La conformité au châssis du convertisseur des medias de 10”/19” de PLANET l
GT-80x Le convertisseur des médias Gigabit Ethernet:
Conforme aux normes IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX, IEEE 802.3ab 1000Base-T, IEEE 802.3z l 1000Base-SX/LX
Le taux de transfert des données: TP – 10/100/1000Mbps; FX – 1000Mbps l
Le commutateur DIP pour la conguration des paramètres de la fonction l LFP (Activer / Désactiver)
Le maintien d’OAM (TS-1000 and IEEE 802.3ah) l
Le maintien du frame Jumbo 9K l
La conformité au châssis du convertisseur des medias de 10”/19” de PLANET l
Dans les sections suivantes, le terme "FT-80x / GT-80x" indique la famille de produits ci-dessus; le terme "MM" et "SM" représente les modes optiques à bre Multi-Mode et Single Mode.
2. L'aide-Mémoire
L’emballage de votre FT-80x / GT-80x doit contenir les éléments suivants:
Le convertisseur des médias Fast/Gigabit Ethernet n
L’adaptateur de l’alimentation CA-CD (l’alimentation de sortie: 5V CD, 2A au maximum) n
Ce manuel d’utilisateur n
Si un élément est manquant ou endommagé, veuillez consulter le revendeur auprès duquel vous avez acheté votre convertisseur des médias Fast/Gigabit Ethernet.
Française
GT-805A contient un emplacement vacant pour le module SFP. Le mini-module GBIC SFP n'est pas inclus dans l'emballage.
2-1
3. Le Produit
Fast Ethernet Bridge 10/100Base-TX to 100Base-FX
TX RX
FX TX
100PWR
FDX/ COL
LNK/ ACT
Gigabit Ethernet Converter 10/100/1000Base-T to 1000Base-SX/LX
TX RX
LNK
ACT
PWR 1000
LFP
OFF
ON
TPFiber
LNK /ACT
Gigabit Ethernet Converter 10/100/1000Base-T to 1000Base-SX/LX
Mini-GBIC
LNK
ACT
PWR 1000
LFP
OFF
ON
TPFiber
LNK /ACT
Gigabit Ethernet Converter 10/100/1000Base-T to 1000Base-LX
WDM
LNK
ACT
PWR 1000
LFP
OFF
ON
TPFiber
LNK /ACT
FX Duplex
HDX FDX
5V DC
+
La vue de droite (FT-80x)
La vue représente un connecteur -paire détourné RJ-45 (Auto-MD I /MDI-X), un connecteur optique à bre (varie selon le modèle) et six indicateurs DEL.
Française
La gure 1: La vue de droite de FT-80x
La vue de droite (GT-80x)
La vue représente un connecteur -paire détourné RJ-45 (Auto-MD I /MDI-X), un connecteur optique à bre (varie selon le modèle) et quatre indicateurs DEL. En plus, un commutateur DIP pour la foction Link-Fault
-Passthrough (LFP), "ON" pour activer LLCF et la détection LLR, ainsi que "OFF" pour désactiver la foction. An d’obtenir plus d’information, veuillez vous référer aux sections suivantes.
La gure 2: La vue de droite de GT-802/802S
La gure 3: La vue de droite de GT-805A
La vue de gauche (FT-80x)
Une prise CD 5V et un commutateur DIP pour la sélection du mode de fonctionnement optique à bre, FDX pour le plein-duplex et HDX pour le semi­duplex.
2-2
la vue de droite de GT-806A15/B15/A60/B60
La gure 4:
La gure 5: La vue de gauche de FT-80x
La vue de gauche (GT-80x)
5V DC
+
OFF ON
LFP
La note
Le panneau arrière du convertisseur des médias Gigabit Ethernet contient une prise CD, qui accepte l’alimentation d’entrée de 5V CD 2A.
La gure 6: La vue de gauche de GT-80x
La vue latérale (FT-80x)
Un commutateur DIP pour la fonction Link Fault Pass Through (LFP), "ON" pour activer LLCF et la détection LLR, ainsi que "OFF" pour désactiver la foction. An d’obtenir plus d’information , veuillez vous référer aux sections suivantes.
La gure 7: La vue latérale de FT-80x
4. Link Fault Pass Through (LFP)
La fonction LFP inclut la fonction Link-Fault-Passthrough (LLCF/LLR) et la conception des commutateurs DIP. LLCF/LLR peut immédiatement alarmer aux administrateurs le problème des médias de lien, ainsi que fournir une solution ecace pour surveiller le réseau. Le commutateur DIP permet de désactiver ou activer la fonction LFP.
LLCF (Link Loss Carry Forward) signie que, lorsqu’un périphérique connecté au convertisseur et la ligne TP a perdu le lien, la bre du convertisseur va déconnecter le lien de transmission. LLR (Link Loss Return) signie que, lorsqu’un périphérique connecté au convertisseur et la ligne à bre a perdu le lien, la bre du convertisseur va déconnecter le lien de transmission.
La fonction LFP est activée par défaut. Si vous êtes familier avec l'installation du réseau, à des fins diagnostiques (par exemple, afin de vérifier lequel bout est hors de fonction­nement), vous pouvez l'éteindre et réinitialiser le convertisseur pour qu'il prenne effet. Sinon, veuillez laisser la configuration de la fonction par défaut.
5. L’installation Du Convertisseur
Pour installer le FT-80x / GT-80x en autonome, sur un bureau ou une étagère, il sut de suivre les étapes suivantes:
L’étape 1: Désactivez l'alimentation de l'appareil/la station d'un réseau auquel FT-80x / GT-80x sera
connecté.
L’étape 2: Branchez le câble à bre de FT-80x / GT-80x au réseau à bre. TX, RX doivent être couplés aux
deux extrémités.
L’étape 3: Attachez le câble Cat. 5/5e/6 UTP du réseau 10/100Base-TX or 10/100/1000Base-T au port RJ-45
de FT-80x / GT-80x.
2-3
L’étape 4: Connectez L'adaptateur de l’alimentation de CD de 5V à FT-80x / GT-80x et assurez-vous que
RX
TX
FT-80X
TX RX
10/100Base-TX Cat.5/5e TP Cable Network
100Base-FX Fiber Network
RX
TX
GT-80X
TX RX
10/100/1000Base-T Cat.5/5e/6 TP Cable Network
1000Base-SX/LX Fiber Network
La note
l’indicateur DEL d’alimentation s’allume.
L’étape 5: Activez l'alimentation de l'appareil/la station, les indicateurs DEL des liens TX et FX doivent s’al-
lumer lorsque tous le câbles sont attachés.
La gure 8: L’installation de FT-80x
La gure 9: L’installation de GT-80x
1. Il est recommande d’utiliser les séries 1000Base-SX/LX de PLANET MGB-SX / MGB-LX SFP avec GT-805A. Si vous insérez un émetteur-récepteur SFP qui n’est pas supporté, GT-805A ne le reconnaîtra pas.
2. Veuillez vérifier le lien-budget de vos émetteurs-récepteurs SFP et sa distance de câblage physique; dans certaines cas d'installation, un atténuateur optique en ligne peut être nécessaire pour protéger vos émetteurs-récepteurs.
6. Le Maintien Du Mode Duplex
Le port FT-80x TP maintient la détection du mode duplex par auto-négociation (A-N). Il détecte automatiquement la vitesse du lien et le mode duplex par défaut, ainsi que retombe automatiquement au mode semi-duplex de 100 ou 10 Mbps avec son partenaire du lien. Le port à bre maintient la sélection du commutateur DIP pour le plein-duplex (par défaut) ou le semi-duplex.
Le port GT-80x TP maintient la vitesse triple - 10/100/1000Base-T, l’Auto-négociation. Il détecte automatiquement la vitesse du et le mode duplex par défaut avec son partenaire du lien. Le port à bre ­1000Base-SX/LX, permet le plein-duplex de 1000Mbps par l’Auto-Négociation. Veuillez également vérier les congurations du partenaire de lien.
2-4
7. L’indication Del
FT-80x:
L’indicateur DEL La couleur La description
FX LNK / ACT Verte
TX LNK / ACT Verte
FX FDX / COL Verte
TX FDX / COL Verte
100 Verte
PWR Vert e Allumé: lorsque l'alimentation +5V CD est détectée.
GT-80x:
L’indicateur DEL La couleur La description
PWR Vert e Allumé: lorsque l'alimentation +5V CD est détectée.
Fiber LNK/ACT Verte
TP LNK/ACT Verte
Clignote: lors de la transmission et la réception des paquets FX.
Allumé: lorsque la connexion à bre est bonne.
Clignote: lors de la transmission et la réception des paquets TP.
Allumé: lorsque la connexion TP est bonne.
Allumé: lorsque le mode plein-duplex est activé dans le port FX.
Clignote: lorsque le port FX est en mode semi-duplex et reçoit un
choc.
Allumé: lorsque le mode plein-duplex est activé (la détection par l’Auto-Négociation) dans le port TP.
Clignote: lorsque le port TP reçoit un choc.
Allumé: lorsque le port TP fonction en 100Mbps. Reste éteint: lorsque l'indicateur DEL du lien allumé indique que le
port TP fonctionne en 10Mbps.
Allumé: An d'indiquer que le lien via le port à bre est successivement établi.
Clignote: Indique l'envoi ou la réception active des données via le port à bre.
Allumé: An d'indiquer que le lien via le port TP est successivement établi.
Clignote: Indique l'envoi ou la réception active des données via le port.
TP 1000 Verte
Allumé: Lorsque le port fonctionne en vitesse de ligne de 1000Mbps.
Eteint: Lorsque le port fonctionne en 10/100Mbps.
2-5
8. Les Parametres De La Connexion Des Cables
La note
Les câbles:
Le standard (La longueur de l’onde)
Le type de bre & La spécication du câble
FT-80x:
Les détails du câblage sont indiqués ci-dessous: La distance du câblage:
Duplex La connexion Les limites (max.)
La paire détournée
Semi / Plein
Les convertisseurs Multi-Mode
Semi MM
Plein MM
Les convertisseurs Single -Mode* (FT-80xynn; x= 2, 6; y= S, A, B; nn=km)
Plein SM
GT-80x:
Les distances du câblage:
Le standard La bre Le diamètre (micron) Le débit (MHz x km) La distance maximale (mètres)
1000Base-SX MM
1000Base-LX
100Base-FX (1310nm) 1000Base-SX (850nm) 1000Base-LX (1310nm)
Le multi-mode 50/125μm ou 62.5/125μm
Le single mode 9/125μm
Nœud à nœud Nœud à commutateur/hub
Nœud à nœud Nœud à commutateur
Nœud à nœud Nœud à commutateur
Nœud à nœud Nœud à commutateur
62.5 50
MM
SM 9 N/A 5000*
62.5 50
100 500
5 5
100 mètres
412 mètres
2 kilomètres
Dépend du modèle
220 550
550
Le port Single mode (le port 1000Base-LX) de GT-802S, GT-805A, GT-806A15/B15 et GT-806A60/B60 conforme aux 5 kilomètres de LX et fournit une marge supplémentaire permettant le lien Gigabit Ethernet à 10 / 15 / 60 kilomètres (120km au maximum) au Single mode fibre.
2-6
9. Les Specications Du Produit
La note
FT-80x
Le modèle FT-801 FT-802 FT-802S15 FT-802S35 FT-802S50
Le connecteur à bre ST SC SC SC WDM
Le mode bre Multi-mode Single mode
La distance maximale de la bre
Le connecteur-agent 10/100Mbps RJ-45
Les modes agents Plein-Duplex, l’auto-négociation
Le taux de transfert des paquets (64 bytes)
Le commutateur DIP LFP Désactivée / Activée; FX Plein- / Semi-duplex
Les protocoles et les standards
Les dimensions 97 x 69 x 26 mm (W x D x H)
Le poids 0.2kg
L’alimentation 5V CD, 2A au maximum
L’émission FCC, CE
La température Le fonctionnement: 0 ~ 50°C / La conservation: -40 ~ 70°C
L’humidité 5% ~ 95% sans condensation
L’installation Le montage au mur, le rail DIN, l’installation du châssis
1. Veuillez noter que FT-806A20/806B20 sont désignés de fonctionner en pair. Cela dit que vous devez connecter FT-806A20 à FT-806B20 en pair. En cas les deux extrémités sont FT-806A20 (ou FT-806B20), ou tout modèle mentionné ci-dessus est connecté à quelque autre périphérique, ils peuvent ne pas fonctionner normale­ment, ainsi que les connecteurs à fibre peuvent être endommagés.
2. Le convertisseur des medias des séries FT-802xxx / FT-806xxx le single mode fournit le maintien à longue distance de 15 à 50 km. Lorsque la distance courte du câble à fibre du single mode est utilisée, vous pourriez avoir besoin d'insérer l’atténuateur optique en ligne dans le lien pour éviter la surcharge du récepteur.
3. Lors de la connexion aux produits Fast Ethernet, veuillez vous référer au manuel technique de l'appareil.
4. Consultez votre revendeur à propos de l'installation du rail DIN ou du châssis.
2km 15km 35km 50km 20km
14880pps @10Mbps; 148810pps @100Mbps
IEEE 802.3, 10Base-T IEEE 802.3u, 100Base-TX, 100Base-FX
FT-806A20 FT-806B20
2-7