1. Product Features ..........................................................................................................................................................................................................1-1
4. Link Fault Pass Through (LFP) .............................................................................................................................................................................1-3
5. Installing The Converter .........................................................................................................................................................................................1-3
6. Duplex Mode Support ............................................................................................................................................................................................1-4
7. LED Indication ............................................................................................................................................................................................................... 1-5
1. Les Caracteristiques Du Produit ....................................................................................................................................................................... 2-1
3. Le Produit .......................................................................................................................................................................................................................... 2-2
4. Link Fault Pass Through (LFP) .............................................................................................................................................................................2-3
5. L’installation Du Convertisseur ........................................................................................................................................................................... 2-3
6. Le Maintien Du Mode Duplex ........................................................................................................................................................................... 2-4
7. L’indication Del ..............................................................................................................................................................................................................2-5
8. Les Parametres De La Connexion Des Cables .......................................................................................................................................2-6
9. Les Specications Du Produit ............................................................................................................................................................................ 2-7
4. Link Fault Pass Through (LFP) Verbindungsfehler-Durchreiche ................................................................................................3-3
5. Installierung Des Konverters ............................................................................................................................................................................... 3-3
6 Duplex Modus Unterstützung ........................................................................................................................................................................... 3-4
7. LED Anzeige ....................................................................................................................................................................................................................3-5
1. Характеристики Изделия ...................................................................................................................................................................................4-1
3. Вид Продукта ................................................................................................................................................................................................................ 4-2
4. Link Fault Pass Through (LFP) .............................................................................................................................................................................4-3
5. Установка Конвертера .......................................................................................................................................................................................... 4-3
6. Поддержка Режима Duplex...............................................................................................................................................................................4-4
8. Параметры Проводного Соединения ..................................................................................................................................................... 4-6
9. Технические Условия Эксплуатации Изделия ..................................................................................................................................4-7
Português
1. Características do Produto ................................................................................................................................................................................... 5-1
3. Panorama do Produto .............................................................................................................................................................................................5-2
4. Link Fault Pass Through (LFP) .............................................................................................................................................................................5-3
5. Instalando o Conversor........................................................................................................................................................................................... 5-3
6 Modo Duplex de Suporte.....................................................................................................................................................................................5-4
8 Parâmetro de Conexão do Cabo ..................................................................................................................................................................... 5-6
9. Especicação do Produto ..................................................................................................................................................................................... 5-7
Español
1. Caracteristicas Del Producto ............................................................................................................................................................................... 6-1
2. Lista De Control ............................................................................................................................................................................................................ 6-1
3. Una Mirada Al Producto Product Outlook ...............................................................................................................................................6-2
4. Pase De Error De Enlace (LFP) ...........................................................................................................................................................................6-3
5. Instalacion Del Convertidor .................................................................................................................................................................................6-3
6. Soporte Del Modo Duplex................................................................................................................................................................................... 6-4
7. Indicadores Del LED .................................................................................................................................................................................................. 6-5
8. Parametro De La Conexion De Cable .......................................................................................................................................................... 6-6
9. Especicaciones Del Producto .......................................................................................................................................................................... 6-7
1. Product Features
Note
FT-80x Fast Ethernet Media Converter:
Comply with IEEE 802.3/802.3u, 10/100Base-TX, 100Base-FX Standard l
Data Transfer Rate: TP - 10/100Mbps; FX - 100Mbps l
Duplex mode support: l
- Full or half-duplex mode by Auto-Negotiation (Twisted Pair port)
- Full or half-duplex mode by DIP-switch (Fiber port)
Compliance with PLANET’s 10”/19” Media Converter Chassis l
GT-80x Gigabit Ethernet Media Converter:
Comply with IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX, IEEE 802.3ab 1000Base-T, IEEE 802.3z l
1000Base-SX/LX standard
Data Transfer Rate: TP – 10/100/1000Mbps; FX – 1000Mbps l
DIP switch for lLFP function (Disable / Enable) setting
OAM (TS-1000 and IEEE 802.3ah) supported l
9K Jumbo frame supported l
Compliance with PLANET’s 10”/19” Media Converter Chassis l
In the following sections, the term "FT-80x / GT-80x" indicates the product family above, the term "MM"
and "SM" represent Multi-Mode and Single Mode ber-optic mode.
2. Checklist
Your FT-80x / GT-80x carton should contain the following items:
The Fast / Gigabit Ethernet Media Converter n
AC-DC Power Adapter (Output: 5V DC, 2A max.) n
This User’s Manual n
If any item is missing or damaged, please consult the dealer from whom you purchased your Fast / Gigabit
Ethernet Media Converter.
English
GT-805A is with one vacant SFP module slot. The mini GBIC SFP module is not bundled
with in the package.
1-1
Fast Ethernet Bridge
10/100Base-TX to 100Base-FX
TXRX
FX TX
100PWR
FDX/
COL
LNK/
ACT
Gigabit Ethernet Converter
10/100/1000Base-T to 1000Base-SX/LX
TXRX
LNK
ACT
PWR 1000
LFP
OFF
ON
TPFiber
LNK /ACT
Gigabit Ethernet Converter
10/100/1000Base-T to 1000Base-SX/LX
Mini-GBIC
LNK
ACT
PWR 1000
LFP
OFF
ON
TPFiber
LNK /ACT
Gigabit Ethernet Converter
10/100/1000Base-T to 1000Base-LX
WDM
LNK
ACT
PWR 1000
LFP
OFF
ON
TPFiber
LNK /ACT
FX Duplex
HDXFDX
5V DC
+
English
3. Product Outlook
Right View (FT-80x)
There are one RJ-45 Twisted-Pair jack (Auto-MD I /MDI-X), one ber-optic connector (var y by model) and six
LED indicators.
Figure 1: FT-80x Right View
Right View (GT-80x)
There are one RJ-45 Twisted-Pair jack (Auto-MDI/MDI-X), one ber-optic connector (vary by model) and four
LED indicators. Also One DIP switch for Link-Fault -Ppassthrough (LFP) feature, "ON" to turn-on the LLCF and
LLR detection. And "OFF" to turn o the feature. Please refer to the following sections for more.
Figure 2: GT-802/802S Right View
Figure 3: GT-805A Right View
Left View (FT-80x)
One DC 5V power socket and one DIP switch for
Fiber-optic operating mode selection, FDX for fullduplex, and HDX for half-duplex.
1-2
Figure 4: GT-806A15/B15/A60/B60 Right View
Figure 5: FT-80x Left View
Left View (GT-80x)
5V DC
+
OFFON
LFP
Note
The rear panel of the Gigabit Ethernet Media
Converter indicates one DC jack, which accepts input
power with 5V DC 2A.
Figure 6: GT-80x Left View
Side View (FT-80x)
One DIP switch for Link Fault Pass Through (LFP)
feature, "ON" to turn-on the LLCF and LLR detection.
And "OFF" to turn –o this feature. Please refer to the
following sections for more.
Figure 7: FT-80x Side View
4. Link Fault Pass Through (LFP)
The LFP function includes the Link-Fault-Passthrough function (LLCF/LLR) and the DIP Switch design. LLCF/
LLR can immediately alarm administrators the problem of the link media and provide ecient solution to
monitor the network. The DIP Switch will disable or enable the LFP function.
LLCF (Link Loss Carry Forward) means when a device connected to the converter and the TP line loss the
link, the converter’s ber will disconnect the link of transmit. LLR (Link Loss Return) means when a device
connected to the converter and the ber line loss the link, the converter’s ber will disconnect the link of
transmit.
LFP function is ON by default setting. If you are familiar with the network installation
and for diagnostic purpose (i.e. check which end is broken), you can turn it off and reset
the converter to make it take effect. Otherwise, please remain it in the default position.
5. Installing The Converter
To install FT-80x / GT-80x stand-alone, on a desktop or shelf, simply complete the following steps:
Step 1: Turn o the power of the device/station in a network to which the FT-80x / GT-80x will be
attached.
Step 2: Attach ber cable from the FT-80x / GT-80x to the ber network. TX, RX must be paired at both
ends.
1-3
Step 3: Attach a Cat. 5/5e/6 UTP cable from the 10/100Base-TX or 10/100/1000Base-T network to the
RX
TX
FT-80X
TX
RX
10/100Base-TX
Cat.5/5e TP
Cable Network
100Base-FX
Fiber Network
RX
TX
GT-80X
TX
RX
10/100/1000Base-T
Cat.5/5e/6 TP
Cable Network
1000Base-SX/LX
Fiber Network
Note
RJ-45 port on the FT-80x / GT-80x.
Step 4: Connect the 5VDC power adapter to the FT-80x / GT-80x and verify that the Power LED lights
up.
Step 5: Turn on the power of the device/station, the TX Link and FX Link LEDs should light when all
cables are attached.
Figure 8: FT-80x Installation
Figure 9: GT-80x Installation
1. It is recommends using PLANET MGB-SX / MGB-LX series 1000Base-SX/LX SFP on
the GT-805A. If you insert a SFP transceiver that is not supported, the GT-805A will
not recognize it.
2. Please check the link-budget of your SFP transceivers and its physical wiring
distance, in some installation, a in-line optical attenuator may be required to protect
your transceivers.
6. Duplex Mode Support
The FT-80x TP port supports duplex mode detection by auto-negotiation (A-N). It shall auto detects the link
speed and the duplex mode by default. And auto fall-back to 100 or 10Mbps half-duplex mode with its link
partner. The ber port supports DIP switch selection for Full-duplex (default) or Half-duplex.
The GT-80x TP port supports triple speed - 10/100/1000Base-T, Auto-negotiation. It shall auto detects the
link speed and the duplex mode by default with its link partner. The Fiber port - 1000Base-SX/LX, allow
1000Mbps full duplex by Auto-Negotiation. Please also check the setting of the link partner as well.
1-4
7. LED Indication
FT-80x:
LEDColorDescription
FX LNK / ACTGreen
TX LNK / ACTGreen
FX FDX / COL Green
TX FDX / COLGreen
100Green
PWRGreen Lit: when +5VDC power detected.
GT-80x:
LEDColorDescription
PWRGreen Lit: When +5V DC power detected.
Fiber LNK/ACTGreen
TP LNK/ACTGreen
TP 1000Green
Blinks: when any FX packets transmitting and receiving.
Lit: when Fiber connection is good.
Blinks: when any TP packets transmitting and receiving.
Lit: when TP connection is good.
Lit: when Full-duplex mode is enabled in FX port.
Blinks: when FX port is in half-duplex mode and receives collision.
Lit: when Full-duplex mode is enabled (detect by Auto-Negotiation) in TP port.
Blinks: when TP port receive collision.
Lit: when the TP port runs in 100Mbps.
Remains o while LINK LED lit represent the TP port runs in 10Mbps.
Lit: To indicate the link through ber por t is successfully established.
Blink: Indicate the ber port is actively sending or receiving data.
Lit: To indicate the link through TP port is successfully established.
Blink: Indicate the port is actively sending or receiving data.
Lit: When the port runs in 1000Mbps line speed.
O: When the port runs in 10/100Mbps.
1-5
8. Cable Connection Parameter
Note
Cables:
Standard (Wavelength) 100Base-FX (1310nm)1000Base-SX (850nm)1000Base -LX (1310nm)
StandardFiberDiameter (micron)Bandwidth (MHz x km)Max. Distance (meters)
1000Base-SXMM
1000Base-LX
Multi-mode50/125μm or 62.5/125μm
Single-mode9/125μm
Node to Node
Node to Switch/Hub
Node to Node
Node to Switch
Node to Node
Node to Switch
Node to Node
Node to Switch
62.5
50
62.5
MM
50
SM9N/A5000*
100
500
5
5
100 meters
412 meters
2 kilometers
Depends on model
220
550
550
The Single-mode port (1000Base-LX port) of GT-802S, GT-805A, GT-806A15/B15 and
GT-806A60/B60 is complied with LX 5 kilometers and provides additional margin
allowing for a 10 / 15 / 60 kilometers Gigabit Ethernet link (max. 120k m) on single mode
fiber.
1-6
9. Product Specication
Note
FT-80x
ModelFT-801 FT-802 FT-802S15 FT-802S35 FT-802S50
Fiber ConnectorSTSCSCSC WDM
Fiber ModeMulti-modeSingle-mode
Fiber Maximum Distance2km15km35km50km20km
Copper Connector10/100Mbps RJ-45
Copper ModesFull Duplex, auto-negotiation
Packet Forwarding Rate
(64bytes)
DIP switchLFP Disable / Enable; FX Full / Half-duplex
connect FT-806A20 to FT-806B20 in pair. If both ends are FT-806A20 (or FT-806B20),
or any above model to any 3rd party device, they can’t work normally and may
damage the fiber connectors.
distance support from 15 km to 50km. When shorter distance of single-mode fiber
cable is used, you might need to insert an in-line optical attenuator in the link to
avoid overloading of the receiver.
1. Please note GT-806A15/806B15 and GT-806A60/806B60 is designed to work
together. It means you must connect GT-806A15 to GT-806B15 or GT-806A60 to
GT-806B60 in pairs. If both ends are GT-806A15 or GT-806A60 and GT-806B15 or
GT-806B60, or any above model to any 3rd party device, they can’t work normally
and may damage the fiber connectors.
2. The GT-802S / GT-806xxx series single mode Media Converter provide long distance
support from 10 km to 60km. When shorter distance of single-mode fiber cable
is used, you might need to insert an in-line optical attenuator in the link to avoid
overloading the receiver:
3. Connecting to the Gigabit Ethernet products, please refer to the device’s Technical
Manual.
4. Consult your dealer for DIN-Rail or Chassis installation.
1-9
This page is intentionally left blank
1. Les Caracteristiques Du Produit
La note
FT-80x Le convertisseur des médias Fast Ethernet:
Conforme aux normes IEEE 802.3/802.3u, 10/100Base-TX, 100Base-FX l
Le taux de transfert des données: TP - 10/100Mbps; FX - 100Mbps l
Le maintien du mode duplex: l
- Le mode plein- ou semi-duplex par l'Auto-Négociation (Le port-paire détourné)
- Le mode plein- ou semi-duplex par le commutateur DIP (le port à bre)
Le commutateur DIP: 2 commutateurs DIP; la sélection du mode duplex FX & la sélection du mode LFP l
La conformité au châssis du convertisseur des medias de 10”/19” de PLANET l
GT-80x Le convertisseur des médias Gigabit Ethernet:
Conforme aux normes IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX, IEEE 802.3ab 1000Base-T, IEEE 802.3z l
1000Base-SX/LX
Le taux de transfert des données: TP – 10/100/1000Mbps; FX – 1000Mbps l
Le commutateur DIP pour la conguration des paramètres de la fonction lLFP (Activer / Désactiver)
Le maintien d’OAM (TS-1000 and IEEE 802.3ah) l
Le maintien du frame Jumbo 9K l
La conformité au châssis du convertisseur des medias de 10”/19” de PLANET l
Dans les sections suivantes, le terme "FT-80x / GT-80x" indique la famille de produits ci-dessus; le terme
"MM" et "SM" représente les modes optiques à bre Multi-Mode et Single Mode.
2. L'aide-Mémoire
L’emballage de votre FT-80x / GT-80x doit contenir les éléments suivants:
Le convertisseur des médias Fast/Gigabit Ethernet n
L’adaptateur de l’alimentation CA-CD (l’alimentation de sortie: 5V CD, 2A au maximum) n
Ce manuel d’utilisateur n
Si un élément est manquant ou endommagé, veuillez consulter le revendeur auprès duquel vous avez
acheté votre convertisseur des médias Fast/Gigabit Ethernet.
Française
GT-805A contient un emplacement vacant pour le module SFP. Le mini-module GBIC
SFP n'est pas inclus dans l'emballage.
2-1
3. Le Produit
Fast Ethernet Bridge
10/100Base-TX to 100Base-FX
TXRX
FX TX
100PWR
FDX/
COL
LNK/
ACT
Gigabit Ethernet Converter
10/100/1000Base-T to 1000Base-SX/LX
TXRX
LNK
ACT
PWR 1000
LFP
OFF
ON
TPFiber
LNK /ACT
Gigabit Ethernet Converter
10/100/1000Base-T to 1000Base-SX/LX
Mini-GBIC
LNK
ACT
PWR 1000
LFP
OFF
ON
TPFiber
LNK /ACT
Gigabit Ethernet Converter
10/100/1000Base-T to 1000Base-LX
WDM
LNK
ACT
PWR 1000
LFP
OFF
ON
TPFiber
LNK /ACT
FX Duplex
HDXFDX
5V DC
+
La vue de droite (FT-80x)
La vue représente un connecteur -paire détourné RJ-45 (Auto-MD I /MDI-X), un connecteur optique à bre
(varie selon le modèle) et six indicateurs DEL.
Française
La gure 1: La vue de droite de FT-80x
La vue de droite (GT-80x)
La vue représente un connecteur -paire détourné RJ-45 (Auto-MD I /MDI-X), un connecteur optique à bre
(varie selon le modèle) et quatre indicateurs DEL. En plus, un commutateur DIP pour la foction Link-Fault
-Passthrough (LFP), "ON" pour activer LLCF et la détection LLR, ainsi que "OFF" pour désactiver la foction.
An d’obtenir plus d’information, veuillez vous référer aux sections suivantes.
La gure 2: La vue de droite de GT-802/802S
La gure 3: La vue de droite de GT-805A
La vue de gauche (FT-80x)
Une prise CD 5V et un commutateur DIP pour la
sélection du mode de fonctionnement optique à
bre, FDX pour le plein-duplex et HDX pour le semiduplex.
2-2
la vue de droite de GT-806A15/B15/A60/B60
La gure 4:
La gure 5: La vue de gauche de FT-80x
La vue de gauche (GT-80x)
5V DC
+
OFFON
LFP
La note
Le panneau arrière du convertisseur des médias
Gigabit Ethernet contient une prise CD, qui accepte
l’alimentation d’entrée de 5V CD 2A.
La gure 6: La vue de gauche de GT-80x
La vue latérale (FT-80x)
Un commutateur DIP pour la fonction Link Fault Pass
Through (LFP), "ON" pour activer LLCF et la détection
LLR, ainsi que "OFF" pour désactiver la foction. An
d’obtenir plus d’information , veuillez vous référer aux
sections suivantes.
La gure 7: La vue latérale de FT-80x
4. Link Fault Pass Through (LFP)
La fonction LFP inclut la fonction Link-Fault-Passthrough (LLCF/LLR) et la conception des commutateurs
DIP. LLCF/LLR peut immédiatement alarmer aux administrateurs le problème des médias de lien, ainsi que
fournir une solution ecace pour surveiller le réseau. Le commutateur DIP permet de désactiver ou activer
la fonction LFP.
LLCF (Link Loss Carry Forward) signie que, lorsqu’un périphérique connecté au convertisseur et la ligne
TP a perdu le lien, la bre du convertisseur va déconnecter le lien de transmission. LLR (Link Loss Return)
signie que, lorsqu’un périphérique connecté au convertisseur et la ligne à bre a perdu le lien, la bre du
convertisseur va déconnecter le lien de transmission.
La fonction LFP est activée par défaut. Si vous êtes familier avec l'installation du réseau,
à des fins diagnostiques (par exemple, afin de vérifier lequel bout est hors de fonctionnement), vous pouvez l'éteindre et réinitialiser le convertisseur pour qu'il prenne effet.
Sinon, veuillez laisser la configuration de la fonction par défaut.
5. L’installation Du Convertisseur
Pour installer le FT-80x / GT-80x en autonome, sur un bureau ou une étagère, il sut de suivre les étapes
suivantes:
L’étape 1: Désactivez l'alimentation de l'appareil/la station d'un réseau auquel FT-80x / GT-80x sera
connecté.
L’étape 2: Branchez le câble à bre de FT-80x / GT-80x au réseau à bre. TX, RX doivent être couplés aux
deux extrémités.
L’étape 3: Attachez le câble Cat. 5/5e/6 UTP du réseau 10/100Base-TX or 10/100/1000Base-T au port RJ-45
de FT-80x / GT-80x.
2-3
L’étape 4: Connectez L'adaptateur de l’alimentation de CD de 5V à FT-80x / GT-80x et assurez-vous que
RX
TX
FT-80X
TX
RX
10/100Base-TX
Cat.5/5e TP
Cable Network
100Base-FX
Fiber Network
RX
TX
GT-80X
TX
RX
10/100/1000Base-T
Cat.5/5e/6 TP
Cable Network
1000Base-SX/LX
Fiber Network
La note
l’indicateur DEL d’alimentation s’allume.
L’étape 5: Activez l'alimentation de l'appareil/la station, les indicateurs DEL des liens TX et FX doivent s’al-
lumer lorsque tous le câbles sont attachés.
La gure 8: L’installation de FT-80x
La gure 9: L’installation de GT-80x
1. Il est recommande d’utiliser les séries 1000Base-SX/LX de PLANET MGB-SX / MGB-LX
SFP avec GT-805A. Si vous insérez un émetteur-récepteur SFP qui n’est pas supporté,
GT-805A ne le reconnaîtra pas.
2. Veuillez vérifier le lien-budget de vos émetteurs-récepteurs SFP et sa distance de
câblage physique; dans certaines cas d'installation, un atténuateur optique en ligne
peut être nécessaire pour protéger vos émetteurs-récepteurs.
6. Le Maintien Du Mode Duplex
Le port FT-80x TP maintient la détection du mode duplex par auto-négociation (A-N). Il détecte
automatiquement la vitesse du lien et le mode duplex par défaut, ainsi que retombe automatiquement au
mode semi-duplex de 100 ou 10 Mbps avec son partenaire du lien. Le port à bre maintient la sélection du
commutateur DIP pour le plein-duplex (par défaut) ou le semi-duplex.
Le port GT-80x TP maintient la vitesse triple - 10/100/1000Base-T, l’Auto-négociation. Il détecte
automatiquement la vitesse du et le mode duplex par défaut avec son partenaire du lien. Le port à bre 1000Base-SX/LX, permet le plein-duplex de 1000Mbps par l’Auto-Négociation. Veuillez également vérier les
congurations du partenaire de lien.
2-4
7. L’indication Del
FT-80x:
L’indicateur DEL La couleurLa description
FX LNK / ACTVerte
TX LNK / ACTVerte
FX FDX / COL Verte
TX FDX / COLVerte
100Verte
PWRVert eAllumé: lorsque l'alimentation +5V CD est détectée.
GT-80x:
L’indicateur DEL La couleurLa description
PWRVert eAllumé: lorsque l'alimentation +5V CD est détectée.
Fiber LNK/ACTVerte
TP LNK/ACTVerte
Clignote: lors de la transmission et la réception des paquets FX.
Allumé: lorsque la connexion à bre est bonne.
Clignote: lors de la transmission et la réception des paquets TP.
Allumé: lorsque la connexion TP est bonne.
Allumé: lorsque le mode plein-duplex est activé dans le port FX.
Clignote: lorsque le port FX est en mode semi-duplex et reçoit un
choc.
Allumé: lorsque le mode plein-duplex est activé (la détection par
l’Auto-Négociation) dans le port TP.
Clignote: lorsque le port TP reçoit un choc.
Allumé: lorsque le port TP fonction en 100Mbps.
Reste éteint: lorsque l'indicateur DEL du lien allumé indique que le
port TP fonctionne en 10Mbps.
Allumé: An d'indiquer que le lien via le port à bre est
successivement établi.
Clignote: Indique l'envoi ou la réception active des données via le port
à bre.
Allumé: An d'indiquer que le lien via le port TP est successivement
établi.
Clignote: Indique l'envoi ou la réception active des données via le port.
TP 1000Verte
Allumé: Lorsque le port fonctionne en vitesse de ligne de 1000Mbps.
Eteint: Lorsque le port fonctionne en 10/100Mbps.
2-5
8. Les Parametres De La Connexion Des Cables
La note
Les câbles:
Le standard
(La longueur de l’onde)
Le type de bre & La
spécication du câble
FT-80x:
Les détails du câblage sont indiqués ci-dessous:
La distance du câblage:
DuplexLa connexionLes limites (max.)
La paire détournée
Semi / Plein
Les convertisseurs Multi-Mode
Semi MM
Plein MM
Les convertisseurs Single -Mode* (FT-80xynn; x= 2, 6; y= S, A, B; nn=km)
Plein SM
GT-80x:
Les distances du câblage:
Le standardLa breLe diamètre (micron)Le débit (MHz x km) La distance maximale (mètres)
Le port Single mode (le port 1000Base-LX) de GT-802S, GT-805A, GT-806A15/B15 et
GT-806A60/B60 conforme aux 5 kilomètres de LX et fournit une marge supplémentaire
permettant le lien Gigabit Ethernet à 10 / 15 / 60 kilomètres (120km au maximum) au
Single mode fibre.
2-6
9. Les Specications Du Produit
La note
FT-80x
Le modèleFT-801 FT-802 FT-802S15 FT-802S35 FT-802S50
Le connecteur à breSTSCSCSC WDM
Le mode breMulti-modeSingle mode
La distance maximale de
la bre
Le connecteur-agent10/100Mbps RJ-45
Les modes agentsPlein-Duplex, l’auto-négociation
Le taux de transfert des
paquets (64 bytes)
Le commutateur DIPLFP Désactivée / Activée; FX Plein- / Semi-duplex
Les protocoles et les
standards
Les dimensions97 x 69 x 26 mm (W x D x H)
Le poids0.2kg
L’alimentation5V CD, 2A au maximum
L’émissionFCC, CE
La températureLe fonctionnement: 0 ~ 50°C / La conservation: -40 ~ 70°C
L’humidité5% ~ 95% sans condensation
L’installationLe montage au mur, le rail DIN, l’installation du châssis
1. Veuillez noter que FT-806A20/806B20 sont désignés de fonctionner en pair. Cela
dit que vous devez connecter FT-806A20 à FT-806B20 en pair. En cas les deux
extrémités sont FT-806A20 (ou FT-806B20), ou tout modèle mentionné ci-dessus est
connecté à quelque autre périphérique, ils peuvent ne pas fonctionner normalement, ainsi que les connecteurs à fibre peuvent être endommagés.
2. Le convertisseur des medias des séries FT-802xxx / FT-806xxx le single mode fournit
le maintien à longue distance de 15 à 50 km. Lorsque la distance courte du câble
à fibre du single mode est utilisée, vous pourriez avoir besoin d'insérer l’atténuateur
optique en ligne dans le lien pour éviter la surcharge du récepteur.
3. Lors de la connexion aux produits Fast Ethernet, veuillez vous référer au manuel
technique de l'appareil.
4. Consultez votre revendeur à propos de l'installation du rail DIN ou du châssis.