1. Package Contents
100-240V , 50/60Hz, 2A max.
Standard
Extend
Standard
Extend
PoE
1 2 3 4
5 Uplink 6
ACTLNK
PoE-in-Use
FSD-604HP
PWR
Standard
Extend
Check the following contents of your package:
FSD-604HP User’s Manual
Foot Pad Power Cord
If any of these are missing or damaged, please contact your dealer immediately.
Hardware-based 10/100Mbps auto-negotiation and auto
MDI/MDI-X
Flow control for full duplex operation and back pressure
for half duplex operation
1536bytes packet size
Integrates address look-up engine, supporting 2K absolute
MAC addresses
Automatic address learning and address aging
Solid DIP switch to isolate ports to prevent broadcast
storm and defend DHCP spoong
Hardware
Desktop palm size
LED indicators for PoE ready/activity and LINK/ACT
Supports Contact Discharge of ±4KV DC and Air Discharge
of ±6KV DC for Ethernet ESD protection
Supports ±4KV Surge Immunity
Internal AC power supply
Fanless design
Power
Power
Note
Standard PoE Mode
PoE IP Camera
FSD-604HP
PoE
100 meters (328 feet)
Extend PoE Mode
PoE IP Camera
FSD-604HP
PoE
250 meters (820 feet)
PoE
100BASE- TX UTP with PoE
PoE
10BASE- T UTP with PoE
After changing the mode, you need to manually restart the FSD-604HP to make the corresponding configuration take effect.
5. Switch Rear Panel
Figure 5-1 shows the rear panel of the FSD-604HP.
Figure 5-1: FSD-604HP Rear Panel
1. The device is a power-required device, meaning it will not work till it is powered. If your networks should be active all the time, please consider using UPS (Uninterrupted Power Supply) for your device. It will prevent you from
Power
Note
network data loss or network downtime.
2. In some areas, installing a surge suppression device may also help to protect your FSD-604HP from being damaged by unregulated surge or current to the FSD-604HP.
- 1 -
2. Product Features
RJ45 Interface
6-port 10/100TX Ethernet RJ45 copper
4-port IEEE 802.3af/at PoE Injector (Port-1 to Port-4)
Power over Ethernet
Complies with IEEE 802.3af/at Power over Ethernet end-
span PSE
Up to 4 IEEE 802.3af/2 IEEE 802.3at devices powered
Supports PoE power up to 30 watts for each PoE port
60-watt PoE budget
Hardware DIP switch for “Standard” and “Extend” mode
selection; the “Extend” mode features 30-watt PoE transmit distance of 250m at speed of 10Mbps and VLAN isolation
Auto detects powered device (PD)
Circuit protection prevents power interference between
ports
Remote power feeding up to 100m in standard mode
- 3 -
3. Switch Front Panel
Figure 3-1 shows the front panel of the FSD-604HP.
Figure 3-1: FSD-604HP Front Panel
The front panel of the FSD-604HP provides one DIP switch for “Standard” and “Extend” mode selections. The detailed descriptions are shown in the following table.
DIP Switch
Mode
Standard
(default)
Extend
This mode makes the FSD-604HP operate as a general switch and all ports operate at 10/100Mbps auto-negotiation.
This mode makes the FSD-604HP operate as
a VLAN isolation switch and port 1 to port 4 will isolate respectively. Port 1 to port 4 can communicate with port 5~6 (uplink port).
This mode also makes the FSD-604HP
operate at auto–negotiation 10Mbps speed duplex mode only, but the delivery distance of PoE power and network data can reach 250m.
Function
- 5 -
4. LED Indicators
System
LED Color Function
PWR Orange Lights to indicate the Switch has power.
Per 10/100Mbps Port
LED Color Function
PoE Orange
LNK/ACT Green
Lights to indicate the port is providing 52V DC in-line power to remote PoE PD.
Lights to indicate the link through that port is successfully established at 10/100Mbps.
Blinks to indicate that the Switch is actively sending or receiving data over that port.
- 7 -
6. Installing the Switch
This part describes how to install your FSD-604HP and make connections to it. Please read the following topics and follow the procedures as presented.
This FSD-604HP does not need software
Note
Desktop Installation
To install the FSD-604HP on desktop, simply follow the following steps:
Step 1: Place the FSD-604HP on desktop near an electrical
Step 2: Keep enough ventilation space between the
Note
configuration.
outlet.
FSD-604HP and the surrounding objects.
When choosing a location, please keep in mind the environmental restrictions discussed in Chapter 7 -­Product Specifications.
- 2 -
- 4 -
- 6 -
- 8 -
Step 3: Connect your FSD-604HP to network devices.
Office Building Office Area
Warehouse
Control Room
Office Building
FSD-604HP
DC
Power Line (DC)
100BASE-TX UTP
PoE
100BASE-TX UTP with PoE
IEEE 802.3af PoE VoIP Phone
IEEE 802.3at PoE IP Camera
Fixed IP Dome
IEEE 802.3af PoE Splitter
DC
IEEE 802.3af PoE IP Camera
PoE Extender
PoE
PoE
PoE
PoE
A. Connect one end of a standard network cable to
the Port-5~6 of the FSD-604HP that marks with “Uplink”.
B. Connect the other end of the cable to the network
devices such as routers, Ethernet switches or NVRs (network video recorders).
Step 4: Connect your FSD-604HP to PoE PDs.
A. Connect one end of a standard network cable to
one of the four 10/100Mbps RJ45 PoE+ ports of the FSD-604HP.
B. Connect the other end of the cable to the 802.3af/
at PD.
Wall-mount Installation
Step 1: Please nd the wall that can mount the FSD-604HP.
Step 2: Please refer to the picture below and screw the two
screws on the wall.
122mm
Step 3: Hang the FSD-604HP on the screws from the wall.
Step 4: Repeat step 5 of Desktop Installation for power
supply to the FSD-604HP.
Before mounting the device to the wall, please check the location of the electrical outlet and the
Note
length of the Ethernet cable.
- 9 -
Cable distance for Switch If the “DIP Switch Mode” is set to
“Standard”, then the distance between the
FSD-604HP and PC/PD should not exceed 100
Note
meters for UTP/STP cable.
If the “DIP Switch Mode” is set to “Extend”,
then the distance between the FSD-604HP and PC/PD should not exceed 250 meters.
Make sure the wiring is correct
Category 3/4/5 cable can be used in 10 Mbps operation. To reliably operate your network at 100Mbps, you must use an unshielded twisted-pair
Note
(UTP) Category 5/5e cable, or better data grade cabling. While a Category 3 or 4 cable may initially seem to work, it will soon cause data loss.
Step 5: Supply power to the FSD-604HP.
A. Connect one end of the power cable to the Switch.
B. Connect the power plug of the power cable to a
standard wall outlet.
When the Switch receives power, the power LED should remain solid orange.
- 10 -
- 11 -
7.ProductSpecications
Model
Hardware Specications
Network Connector
PoE Inject Port
LED Display
DIP Switch
Switch Architecture Store and Forward switch architecture
MAC Address Table
ESD Protection 6KV
Switch Fabric 1.2Gbps
Switch Throughput 0.89Mpps @64bytes
Maximum Packet Size 1536bytes
Flow Control
Power Requirements AC 100~240V, 2A max.
Power Consumption Max. 63 watts, 214 BTU
Dimensions (W
x D x
Weight 499g
FSD-604HP
4-Port 10/100Mbps 802.3at PoE + 2-Port 10/100Mbps Desktop Switch
6-Port RJ45 for 10/100BASE-TX, auto MDI/ MDIX
4-Port with 802.3af/at PoE injector function (Port 1 to port 4)
System: Power (Orange) Per PoE port: PoE (Orange, port 1 to port 4)
LNK/ACT (Green, port 1 to port 6)
Distance in Standard mode is 100M Distance in Extend mode is 250M Based on the cable category
2K MAC address table with auto learning function
Back pressure for half duplex. IEEE 802.3x pause frame for full duplex
H) 168 x 93 x 32mm
- 12 - - 13 - - 14 -
Power over Ethernet
PoE Standard
IEEE 802.3af Power over Ethernet/PSE IEEE 802.3at Power over Ethernet Plus/PSE
PoE Power Supply Type End-span
Power Pin Assignment 1/2 (+), 3/6 (-)
Per Port 52V DC, 300mA. max. 15.4 watts
PoE Power Output
(IEEE 802.3af) Per Port 52V DC, 600mA. max. 30 watts (IEEE 802.3at)
PoE Power Budget 60 watts
Number of PDs (7
watts)
Number of PDs (15.4 watts)
Number of PDs (30 watts)
4
4
2
Standard Conformance
EMI Safety CE, FCC
Ethernet Fast Ethernet Flow Control Power over Ethernet Power over Ethernet Plus
Standard Compliance
IEEE 802.3 IEEE 802.3u IEEE 802.3x IEEE 802.3af IEEE 802.3at
Environment
Operating Environment 0 ~ 50 degrees C
Storage Environment -10 ~ 70 degrees C
Operating Humidity 5 ~ 95%, relative humidity, non-condensing
Storage Humidity 5 ~ 95%, relative humidity, non-condensing
8. Customer Support
Thank you for purchasing PLANET products. You can browse
our online FAQ resource on PLANET Website rst to check if it
could solve your issue. If you need more support information, please contact PLANET support team.
PLANET online FAQs: http://www.planet.com.tw/en/support/faq.php?type1=1
Support team mail address: support@planet.com.tw
Copyright © PLANET Technology Corp. 2019. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.
Loading...