Planar C5i, DX/PCI, DX2, DX Reference Manual

QUICK LINKS
Contents
Index
Regulatory Compliance
Product Information
Warranty
About the Display
Package Contents
Identify Components
Position Display
Desk Stand Features
INSTALLING THE DISPLAY
Set DIP Switch
Install Display Controller
Connect Video and Power
Install Display Driver
Change Display Properties
Dome CXtra Software
APPENDIXES
Troubleshooting
Specifications
LED Status Lights
Single Desktop
USB Connection
Component Removal
Power Management
Palette Options
Dome
®
C5i Display
DX/DX2 Display Controller
Reference Guide
www.planar.com
QUICK LINKS
Contents
Index
Regulatory Compliance
Product Information
Warranty
About the Display
Package Contents
Identify Components
Position Display
Desk Stand Features
INSTALLING THE DISPLAY
Set DIP Switch
Install Display Controller
Connect Video and Power
Install Display Driver
Change Display Properties
Dome CXtra Software
APPENDIXES
Troubleshooting
Specifications
LED Status Lights
Single Desktop
USB Connection
Component Removal
Power Management
Palette Options
ii
Dome C5i Display
Copyright © 2005 Planar Systems, Inc. All rights reserved.
Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness of the contents. This document is subject to change without notice. Planar provides this information as reference only. Reference to other vendors’ product does not imply any recommendation or endorsement.
This document contains proprietary information protected by copyright. No part of this manual may be reproduced by any mechanical, electronic, or other means, in any form, without prior written permission of the manufacturer.
Planar, Dome C5i, CXtra, and RightLight are either registered trademark or trademarks of Planar Systems, Inc. All other trademarks are the property of their respective owners.
020-0262-03 A
America Sales
Planar Systems, Inc. 1195 NW Compton Drive Beaverton, OR 97006-1992 USA (503) 748-1100 phone (503) 748-1493 fax
Medical Sales
Planar Systems, Inc. 400 Fifth Avenue Waltham, MA 02451-8738 USA (781) 895-1155 phone (781) 895-1133 fax
Europe & Asia-Pacific Sales
European Representative Planar Systems, Inc. Olarinluoma 9, P. O. Box 46 FIN-02201 Espoo, Finland + 358 9 420 01 phone + 358 9 420 0200 fax
medicalsales@planar.com medicalsupport@planar.com www.planar.com
iii
Dome C5i Display
QUICK LINKS
Contents
Index
Regulatory Compliance
Product Information
Warranty
About the Display
Package Contents
Identify Components
Position Display
Desk Stand Features
INSTALLING THE DISPLAY
Set DIP Switch
Install Display Controller
Connect Video and Power
Install Display Driver
Change Display Properties
Dome CXtra Software
APPENDIXES
Troubleshooting
Specifications
LED Status Lights
Single Desktop
USB Connection
Component Removal
Power Management
Palette Options
Contents
Regulatory Compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
iv
Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ix
About the Dome C5i Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
Identify the Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
Position the Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
Desk Stand Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6
Set the DIP Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
Install the Display Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8
Connect Video Cable and Power Supply . . . . . . . . . . . . . . . . . . . . . . .
9
Install the Display Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10
Change the Display Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
Enhancements with Dome CXtra Software . . . . . . . . . . . . . . . . . . . .
13
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14
C5i Display Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16
LED Status Lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
Single Desktop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22
USB Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
Display Driver and Controller Removal . . . . . . . . . . . . . . . . . . . . . . .
26
Power Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27
Palette Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
28
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
32
Overview of Standard Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . .
34
iv
Dome C5i Display
QUICK LINKS
Contents
Index
Regulatory Compliance
Product Information
Warranty
About the Display
Package Contents
Identify Components
Position Display
Desk Stand Features
INSTALLING THE DISPLAY
Set DIP Switch
Install Display Controller
Connect Video and Power
Install Display Driver
Change Display Properties
Dome CXtra Software
APPENDIXES
Troubleshooting
Specifications
LED Status Lights
Single Desktop
USB Connection
Component Removal
Power Management
Palette Options
Regulatory Compliance
United States/European Union/Canada
These displays have been tested and found to comply with IEC/EN 60601-1 and IEC EN 60601-1-2 standards, and is certified to meet medical standard C22.2 No. 601.1-M1990 (C US Mark).
The medical displays, in addition to meeting medical requirements, has been tested and found to comply with the limits for Federal Communications Commission (FCC) Class B computing devices in a typically configured system since many medical offices are located in residential areas. It is the system integrator’s responsibility to test and ensure that the entire system complies with applicable electromagnetic compatibility (EMC) laws.
Planar Systems, Inc. has made great efforts to support the medical device industry, in particular, medical device manufacturers and medical device system integrators. We offer state-of-the-art color displays that are compliant with worldwide accepted medical device safety standards, and for the European market, CE-marked displays based on compliance with counsel directive 93/42/EEC— commonly referred to as the Medical Device Directive (MDD). The following summarizes our qualification of these displays as it relates to compliance with the MDD.
The European Medical Device Directive requires that the intended use of the device be defined. The intended use of these displays is “to display alphanumeric, graphic, and image data as inputted from any type of medical device.” These displays do not provide a measurement function in any way, and it is the device and systems manufacturer’s responsibility to verify its function in the integrated device or system.
The displays were classified as required by the MDD according to Annex IX of the directive and the medical device (MEDDEV) guidance available at the time of classification. Because the display uses electrical energy and has no direct patient connections and—by itself—no medical utility, the display is classified according to Rule 12 as an MDD Class I device, component, or accessory. The mode of operation is continuous. The MDD states that manufacturers of Class I medical devices or accessories shall satisfy the requirements in regard to design and manufacturing controls, that is, the applicable assessment route to be used for CE-marking under the MDD, and it shall carry the CE mark according to Annex XII of the directive, with no notified body annotation.
v
Dome C5i Display
QUICK LINKS
Contents
Index
Regulatory Compliance
Product Information
Warranty
About the Display
Package Contents
Identify Components
Position Display
Desk Stand Features
INSTALLING THE DISPLAY
Set DIP Switch
Install Display Controller
Connect Video and Power
Install Display Driver
Change Display Properties
Dome CXtra Software
APPENDIXES
Troubleshooting
Specifications
LED Status Lights
Single Desktop
USB Connection
Component Removal
Power Management
Palette Options
The applicable safety standards for an MDD Class I display are IEC/EN 60601-1:1990 along with Amendments 1 and 2. To help the medical device designer evaluate the suitability of these displays, Planar has also conducted EMC testing to IEC 60601-1-2 as it can be applied. The display with its power supply alone does not represent a functional medical device. Hence, Planar configured a minimal operating system to exercise the display. The resulting data are made available to interested parties.
This is informative data, not certification data. Certification data must be obtained by the device or system integrator according to Article 12 of the MDD titled “Particular procedure for systems and procedure packs.” Paragraph 2 clearly outlines the device or system integrator’s responsibility in this matter.
In summary, Planar Systems, Inc. is CE-marking these displays under the Medical Device Directive, which establishes compliance to the basic medical safety standards. However, EMC compliance can only be accomplished in the configured medical device or system and is the responsibility of the device or system manufacturer. Planar has the necessary documentation such as IEC 60601-1 notified body and other third-party test reports and certifications, a risk/hazard analysis, an essential requirements checklist, and the Planar International Electrotechnical Commission (IEC) declaration of conformity.
Planar Systems, Inc., located in Beaverton, Oregon, USA, is the manufacturer of these displays in the meaning of the directive. As required by the MDD in Article 14, Planar Systems, Inc., not residing in the European Economic Area (EEA), has a European representative, Planar Systems, Inc.— Olarinluoma 9, P. O. Box 46, FIN-02201 Espoo, Finland (phone + 358 9 420 01; fax + 358 9 420 0200).
In the opinion of Planar Systems, Inc. registration required to put this device into commerce is the responsibility of the medical device/system manufacturer, and Planar supports this requirement by providing a European Commission (EC) declaration of conformity. If Planar supplies a display to an end user, rather than a device manufacturer, it is the end user’s responsibility to ensure continued compliance with the MDD of the system in which the display is integrated.
For vigilance reporting as required under Article 10 of the MDD, Planar Systems, Inc. will provide any information requested by competent authority to support any reported incident investigation by such an authority.
vi
Dome C5i Display
QUICK LINKS
Contents
Index
Regulatory Compliance
Product Information
Warranty
About the Display
Package Contents
Identify Components
Position Display
Desk Stand Features
INSTALLING THE DISPLAY
Set DIP Switch
Install Display Controller
Connect Video and Power
Install Display Driver
Change Display Properties
Dome CXtra Software
APPENDIXES
Troubleshooting
Specifications
LED Status Lights
Single Desktop
USB Connection
Component Removal
Power Management
Palette Options
FCC Compliance Statement
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technical for help.
Caution: Changes or modifications to this equipment not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
vii
Dome C5i Display
QUICK LINKS
Contents
Index
Regulatory Compliance
Product Information
Warranty
About the Display
Package Contents
Identify Components
Position Display
Desk Stand Features
INSTALLING THE DISPLAY
Set DIP Switch
Install Display Controller
Connect Video and Power
Install Display Driver
Change Display Properties
Dome CXtra Software
APPENDIXES
Troubleshooting
Specifications
LED Status Lights
Single Desktop
USB Connection
Component Removal
Power Management
Palette Options
European Union Declaration of Conformity for Medical Application
A Declaration of Conformity has been filed for this product. For additional copies of the Declaration of Conformity document, contact Planar Systems, Inc.
The Dome C5i digital flat-panel display meets the essential health and safety requirements, is in conformity with, and the CE marking has been applied according to the relevant EU Directives listed below, using the relevant section of the following EU standards and other normative documents;
EU EMC Directive 89/336/EEC
EU Electromagnetic Compatibility Directive
EN 60601-1-2 (2001) Medical Electrical Equipment
Section 1.2. Collateral standard electromagnetic compatibility requirements
EN 55011 (Class B) Limits and methods of measurements for radio interference
characteristics of industrial, scientific, and medical equipment
IEC 1000-3-2 Harmonic emissions
IEC 1000-3-3 Voltage fluctuations/flicker emissions
IEC 1000-4-2 Electrostatic discharge requirements for industrial process
measurement and control equipment
IEC 1000-4-3 Radiated electromagnetic field requirements for industrial
process measurement and control equipment
IEC 1000-4-4 Electrically fast transients for industrial process measurement
and control equipment
IEC 1000-4-5 Surge requirements
IEC 1000-4-11 Voltage variations/dips/interrupts
IEC 1000-4-6 Conducted immunity
IEC 1000-4-8 Magnetic field immunity
Conformance to the Medical Device Directive 93/42/EEC
EN 60601-1 Medical Electrical Equipment
Part 1: General requirements for safety
viii
Dome C5i Display
QUICK LINKS
Contents
Index
Regulatory Compliance
Product Information
Warranty
About the Display
Package Contents
Identify Components
Position Display
Desk Stand Features
INSTALLING THE DISPLAY
Set DIP Switch
Install Display Controller
Connect Video and Power
Install Display Driver
Change Display Properties
Dome CXtra Software
APPENDIXES
Troubleshooting
Specifications
LED Status Lights
Single Desktop
USB Connection
Component Removal
Power Management
Palette Options
Australian
China
Japan
Korea
C-Tick Australian Communications Authority regulating product EMC compliance.
CCC China Compulsory Certification regulating safety and EMC.
GB4943-2001
GB9254-1998 (Class A)
CB17625.1-2003
VCCI Voluntary Control Council for Interference by information technology
equipment sold in Japan.
MIC Mark Ministry of Information and Communications.
ix
Dome C5i Display
QUICK LINKS
Contents
Index
Regulatory Compliance
Product Information
Warranty
About the Display
Package Contents
Identify Components
Position Display
Desk Stand Features
INSTALLING THE DISPLAY
Set DIP Switch
Install Display Controller
Connect Video and Power
Install Display Driver
Change Display Properties
Dome CXtra Software
APPENDIXES
Troubleshooting
Specifications
LED Status Lights
Single Desktop
USB Connection
Component Removal
Power Management
Palette Options
Product Information
The design of the Dome C5i digital display takes into account every known measure to ensure your personal safety. Improper use of the display can result in electric shock, fire, or damage to the display. Read all instructions before setting up the display.
Important recycle information:
Symbol explanations
LCD lamp(s) inside this product contain mercury. This product may contain other electronic waste that can be hazardous if not disposed of properly. Recycle or dispose in accordance with local, state, or federal laws. For more information, contact the Electronic Industries Alliance at WWW.EIAE.ORG. For lamp-specifc disposal information, check WWW.LAMPRECYCLE.ORG.
Disposal – Do not use household or municipal waste collection services for disposal
of electrical and electronic equipment. EU countries require the use of separate recycling collection services. Contact local authorities for more information on proper disposal.
Caution – Section contains important information. Read the accompanying text
carefully, for proper operation and maintenance of the display system
Dangerous voltage – Section contains important precautions about electric shock.
Read the accompanying text carefully, to prevent damage to components of the display system and for your safety.
Barometric pressure – Transport and storage
Approx. 12,000 meters (39,400 feet), maximum in unpressurized container
Relative humidity – Transport and storage
<70% (non-condensing)
Temperature – Transport and storage
0° to 50° C
QUICK LINKS
Contents
Index
Regulatory Compliance
Product Information
Warranty
About the Display
Package Contents
Identify Components
Position Display
Desk Stand Features
INSTALLING THE DISPLAY
Set DIP Switch
Install Display Controller
Connect Video and Power
Install Display Driver
Change Display Properties
Dome CXtra Software
APPENDIXES
Troubleshooting
Specifications
LED Status Lights
Single Desktop
USB Connection
Component Removal
Power Management
Palette Options
x
Dome C5i Display
Intended use
The Dome C5i display is an AMLCD display designed for viewing medical X-ray images. This unit is not used near patients and is outside of 1.83 m perimeter and 2.29 m vertical.
Safety precautions
External equipment intended for connection to signal input, signal output, or other connectors, must comply with the relevant IEC standard (EN/IEC 60601-1 series for medical electrical equipment). In addition, all such combinations (systems) must comply with the standard IEC 60601-1-1, Safety requirements for medical electrical systems . Equipment not complying to IEC 60601 must be kept outside the patient environment, as defined in the standard as at least 1.5 meters from the patient or the patient support.
Any person who connects external equipment to signal input, signal output, or other connectors has formed a system and is therefore responsible for the system to comply with the requirements of IEC 60601-1-1. If in doubt, speak with a qualified technician.
To prevent fire or injury
Replace the power supply or cables if damaged.
Use only the appropriate power source indicated in this guide or listed on the display.
Activate the Dome CXtra Backlight Saver service (the preferred method) or the DPMS (Display Power Management Signaling) energy saver when the display is idle for extended periods.
Do not plug the power supply into an overloaded AC outlet or extension cord. Overloaded AC outlets and cords can result in electric shock or fire.
Do not drop or push objects into the display case. Internal components contain high voltage.
Unplug the power cord from the wall outlet during thunderstorms.
Do not place magnetic devices, such as magnets or motors, near the display.
Safety tips
Never open the Dome C5i display case, even when the power is off. Dangerous voltage inside may cause electric shock or death.
To avoid damage to the Dome C5i display, use the grounded power supply and video cable supplied by Planar, or use certified replacements.
Be sure the Dome C5i display is electrically grounded. You must connect the third grounding pin on the US power cord to a grounded outlet. The European power cord does not have a third grounding pin, but it still must be plugged into a grounded outlet.
If you cannot insert the plug into the outlet you plan to use, have a licensed electrician replace the outlet with a properly grounded outlet. If your power cord connects directly into the computer, make sure the computer is grounded.
Take appropriate measures to keep the Dome C5i display dry if it is part of a surgical system. The Dome C5i display lacks protection against liquids or spills.
QUICK LINKS
Contents
Index
Regulatory Compliance
Product Information
Warranty
About the Display
Package Contents
Identify Components
Position Display
Desk Stand Features
INSTALLING THE DISPLAY
Set DIP Switch
Install Display Controller
Connect Video and Power
Install Display Driver
Change Display Properties
Dome CXtra Software
APPENDIXES
Troubleshooting
Specifications
LED Status Lights
Single Desktop
USB Connection
Component Removal
Power Management
Palette Options
xi
Dome C5i Display
To set up the display properly
Allow the display to warm up to room temperature before turning it on.
Avoid sudden temperature changes. Sudden changes may cause condensation that can damage the display.
Turn off your computer, but leave it plugged into a grounded outlet.
Secure the display properly onto a standard VESA 100-mm mounting unit if you elect not to use the desk stand.
Do not step on or place anything on top of the power cord.
Do not set up the display near strong light sources.
Do not block the vents on the back of the display or install the display in a built-in enclosure. Blocked vents cause excessive heat to build up inside the display, increasing risk of fire.
Do not expose the display to water or excessive moisture.
Do not place the display near a heat source.
Do not hang anything from the display.
Use the display only in an indoor setting.
To disconnect the power supply properly
First, turn off your computer and other connected devices. Then unplug the power supply from the display or wall outlet.
Reasons to disconnect power
Power cord is damaged.
Liquid spills inside the display case.
Display is dropped or case is damaged.
Display needs service or repair.
Display or case needs cleaning.
QUICK LINKS
Contents
Index
Regulatory Compliance
Product Information
Warranty
About the Display
Package Contents
Identify Components
Position Display
Desk Stand Features
INSTALLING THE DISPLAY
Set DIP Switch
Install Display Controller
Connect Video and Power
Install Display Driver
Change Display Properties
Dome CXtra Software
APPENDIXES
Troubleshooting
Specifications
LED Status Lights
Single Desktop
USB Connection
Component Removal
Power Management
Palette Options
xii
Dome C5i Display
To clean the LCD screen
1
Unplug the power supply.
2
Dampen a clean, soft nonabrasive cloth with isopropyl alcohol.
3
Wipe the screen gently .
4
Dry the screen with a clean, soft nonabrasive cloth to remove any residue.
Shipping/storing the display
Keep the display in its shipping container until installation. Return the display to its original container whenever you need to store the unit, move it to another location, or return it for repair. The packaging supplied by the manufacturer protects the display from damage while it is in transit. Also see environment specifications for detailed information.
Before returning the display to the container for shipping or storing, do the following:
Swivel the display panel in portrait mode.
Push the panel down to the lowest position.
Use the stand lock to anchor the panel.
Disposal information
Follow your local governing ordinance and recycling policy for proper disposal or recycling of display components.
Maintenance tips
Use a clean, lint-free, absorbent cotton cloth to clear off any residual glue from removal of the protective film.
Use a clean, lint-free, absorbent cotton cloth to remove surface dust. Apply light pressure to remove the dust.
Dampen a clean cloth with
a small amount of isopropyl alcohol to remove glue or dust if the screen is still not clean. Use a clean, dry cloth to completely remove the alcohol residue.
Do not use chemically treated
dust cloths on the display case or LCD screen.
Do not use acetone, toluene, or
harsh solvents. They can damage the polarizer and display case.
Do not saturate the cleaning
cloth with alcohol. The alcohol may seep into the display case and collect in the enclosure.
Do not allow water or other
stains to stand on the unit. Wipe these off immediately to prevent damage to the display case and screen.
QUICK LINKS
Contents
Index
Regulatory Compliance
Product Information
Warranty
About the Display
Package Contents
Identify Components
Position Display
Desk Stand Features
INSTALLING THE DISPLAY
Set DIP Switch
Install Display Controller
Connect Video and Power
Install Display Driver
Change Display Properties
Dome CXtra Software
APPENDIXES
Troubleshooting
Specifications
LED Status Lights
Single Desktop
USB Connection
Component Removal
Power Management
Palette Options
1
Dome C5i Display
About the Dome C5i Display
The Dome C5i display system, 5 megapixels, consists of a thin film transistor, LCD panel and the DX/DX2 controller and driver. The display’s thin film transistors, in a transmissive-type display, use an integrated cold cathode fluorescent tube (CCFT) backlight system.
The display is designed for grayscale medical imaging in diagnostic settings, in either portrait or landscape orientation. It comes fully tuned with gamma correction that complies with the DICOM Part 14 Standard. An all-digital design enables the display to produce the sharp, crisp images critical to softcopy medical viewing. Unwanted analog display image artifacts, such as noise, jitter, ghosting, and image smearing are eliminated.
The Dome C5i display offers the following key features. See the specification for more information.
3061 distinct shades of gray
IPS LCD technology for distortion-free image over a wide-viewing angle
Accelerated hardware rotation for viewing in portrait or landscape mode
Calibrated to DICOM response curve
Automated calibration and backlight stabilization through RightLight technology
The Dome CXtra™ software enhances the functionality of the Dome C5i display. Dome CXtra provides a range of value-added services, such as DICOM calibration, error reporting, and backlight saver.
Before installing the display system, review the safety and installation
precautions. Once your display system is in operation, follow the guidelines for cleaning and servicing your unit. Also see environment specifications for
detailed operating and storage information.
Systems requirements
Computer system
1 PCI slot per board
50 MB hard disk space
256 MB RAM
CD-ROM drive
Operating system
Windows XP or Windows 2000
Dome C5i displays
Size (diagonal) 541 mm (21.3 in)
Resolution 2048 x 2560 pixels
QUICK LINKS
Contents
Index
Regulatory Compliance
Product Information
Warranty
About the Display
Package Contents
Identify Components
Position Display
Desk Stand Features
INSTALLING THE DISPLAY
Set DIP Switch
Install Display Controller
Connect Video and Power
Install Display Driver
Change Display Properties
Dome CXtra Software
APPENDIXES
Troubleshooting
Specifications
LED Status Lights
Single Desktop
USB Connection
Component Removal
Power Management
Palette Options
2
Dome C5i Display
Package Contents
The Dome C5i display system contains the items shown here. Speak with your sales rep if any item is missing or damaged.
Display controller AC power cord
DVI video cable
CD-ROMs with
display driver and Dome CXtra software
DC power adapter
Quick references for Dome CX display and Dome CXtra software
Dome C5i LCD
panel mounted on desk stand
Unpacking and handling tips
The Dome C5i display is a precision instrument that requires proper care to maintain product operation and adherence to specification.
Unpack the display and components carefully. Improper handling may damage or break the LCD glass.
Use both hands to grasp the
display case when lifting it from the shipping carton, but avoid touching the screen.
Do not touch the polarizer with
foreign objects.
Do not touch the polarizer with
bare fingers. Some cosmetics are detrimental to the polarizer, and skin oils are difficult to remove.
Avoid sudden temperature
change as this may cause condensation, which damages the display.
Do not subject the unit to strong
light sources.
Do not remove the back cover or
disassemble the display. There are no user-serviceable parts inside.
QUICK LINKS
Contents
Index
Regulatory Compliance
Product Information
Warranty
About the Display
Package Contents
Identify Components
Position Display
Desk Stand Features
INSTALLING THE DISPLAY
Set DIP Switch
Install Display Controller
Connect Video and Power
Install Display Driver
Change Display Properties
Dome CXtra Software
APPENDIXES
Troubleshooting
Specifications
LED Status Lights
Single Desktop
USB Connection
Component Removal
Power Management
Palette Options
3
Dome C5i Display
Identify the Components
Review this illustration of the back panel to identify controls and ports on the display unit.
Back panel of the Dome C5i display
Dome C5i connector plate
Controls and connector ports
Read the plates from left to right.
Dome C5i
1 Reset button (Restores the
original display configuration.)
2 LED status lights. Provides
information about the status of the display. See page 20.
3 DVI connector (Drives the data
to the display.)
4 8-pin DIN power connector
(Drives power to the display.)
1
4
3
2
Loading...
+ 33 hidden pages