Planar Dome E4c User Manual

Dome E4c Display
User’s Guide
© 2006 Planar Systems, Inc. All rights reserved.
Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness of the contents. This document is subject to change without notice. Planar provides this information as reference only. Reference to other vendors’ product does not imply any recommendation or endorsement.
Planar, Dome, E4c, CXtra, RightLight are either registered trademark or trademarks of Planar Systems, Inc. All other trademarks are the property of their respective owners.
020-0436-00A

Product Information

The design of the Dome E4c digital display takes into account every known measure to ensure your personal safety. Improper use of the display can result in electric shock, fire, or damage to the display. Read all instructions before setting up the display.
Classification:
Shock Protection: Class I.
Degree of Protection Against Electric Shock: No applied part.
Degree of Protection Against Harmful Ingress of Water: Ordinary equipment (IPX0).
Degree of Safety in the Presence of Flammable Anaesthetic Mixture with Air or with Oxygen or Nitrous Oxide: Not suitable for use in the presence of a flammable anaesthetic mixture with air or with oxygen or nitrous oxide.
Mode of Operation: Continuous.
Important recycle instruction:
LCD lamp(s) inside this product contain mercury. This product may contain other electronic waste that can be hazardous if not disposed of properly. Recycle or dispose in accordance with local, state, or federal laws. For more information, contact the Electronic Industries Alliance at
WWW.EIAE.ORG. For lamp-specific disposal information, check WWW.LAMPRECYCLE.ORG.

Symbol explanations

DISPOSAL. Do not use household or municipal waste
collection services for disposal of electrical and electronic equipment. EU countries require the use of separate recycling collection services.
CAUTION. Read the accompanying text carefully, for
proper operation and maintenance of the display system.
DANGEROUS VOLTAGE. Important precautions about
electric shock. Read the accompanying text carefully, to prevent damage to components of the display system and for your safety.
DIRECT CURRENT.
BAROMETRIC PRESSURE.
Maximum operating altitude, up to 3,048 meters (10,000 feet). Maximum unpressurized shipping and storage altitude, up to 12,192 meters (40,000 feet).
RELATIVE HUMIDITY. Operating 10% to 90% (non-
condensing). Transport and storage 5% to 90% (non-condensing).
TEMPERATURE. Operating 0° to 40° C. (Ambient air
temperature surrounding the display.) Transport and storage -10° to 60° C. (NOTE: After shipping or storage, allow display unit to reach room temperature before powering on. Ambient room temperature ranges from 20° to 25° C (68° to 77° F).

Intended use

The Dome E4c display is an AMLCD unit designed for viewing medical X-ray images. This unit should not be used near patients and should be kept outside of 1.83 m perimeter and 2.29 m vertical.
This device must not be used in primary image diagnosis in mammography.
CAUTION: Federal law restricts this device to sale by or on the order of a medical practitioner.
iv | Dome E4c Display

Safety precautions

External equipment intended for connection to signal input, signal output, or other connectors, must comply with the relevant IEC standard (EN/IEC 60601-1 series for medical electrical equipment). In addition, all such combinations (systems) must comply with the standard IEC 60601-1-1, Safety requirements for medical electrical systems.
Equipment not complying to IEC 60601 must be kept outside the patient environment, as defined in the standard as at least 1.5 meters from the patient or the patient support.
Any person who connects external equipment to signal input, signal output, or other connectors has formed a system and is therefore responsible for the system to comply with the requirements of IEC 60601-1-1. If in doubt, speak with a qualified technician.
Safety tips
• Never open the display case, even when the power is off. Do not drop or push objects into the display case. Dangerous voltage inside may cause electric shock or death.
• Use the grounded power supply and the video cable supplied by Planar. Replace the power supply or video cable if damaged.
• Be sure the display is electrically grounded. Connect the third grounding pin on the US power cord to a grounded outlet. The European power cord does not have a third grounding pin, but it must be plugged into a grounded outlet. If the power cord connects directly into the computer, make sure the computer is grounded.
• Keep the display dry if it is part of a surgical system. The display lacks protection against liquids or spills.
• Do not plug the power supply into an overloaded AC outlet or extension cord. Overloaded AC outlets and cords can result in electric shock or fire.
• Unplug the power cord from the wall outlet during thunderstorms.
• Do not place magnetic devices, such as motors, near the display.
• In locations where 240V outlets are used, use the E4c display only on a center-tapped, 240V, single-phase supply.
GROUNDING RELIABILITY CAN ONLY BE ACHIEVED WHEN EQUIPMENT IS CONNECTED TO AN EQUIVALENT RECEPTABLE MARKED “HOSPITAL ONLY” OR “HOSPITAL GRADE.”
Product Information | v

Unpacking and handling tips

The Dome E4c display is a precision instrument that requires proper care to maintain adherence to specification. Unpack the display carefully, then set up and handle the unit properly to avoid damage to the LCD panel.
• Use both hands to grasp the display case when lifting it from the shipping carton, but avoid touching the screen.
• Do not apply pressure to the screen or touch the screen with bare fingers or objects. Pressure can affect image quality.
• Allow the display to warm to room temperature before turning it on. Avoid sudden temperature changes in environment to prevent condensation.
• Secure the display onto the Planar-supplied wall or cart mounting hardware to ensure safety if you elect not to use the desk stand.
• Do not set up the display near strong light or heat sources.
• Do not block the vents on the display or install the display in a built­in enclosure. Blocked vents cause excessive heat inside the display.
• Do not remove the back cover or disassemble the display. There are no user-serviceable parts inside.

Shipping/storing the display

Keep the display in its shipping container until installation. Return the display to its original container whenever you need to store the unit, move it to another location, or return it for repair.
vi | Dome E4c Display

Cleaning the display unit

Periodically wipe the display housing with a soft, dry cloth to prevent dust and other material from clogging the venting holes.
The display screen can be damaged by excessive scrubbing and by incompatible cleaning solvents. Dampen a clean, soft lint-free cloth with distilled de-ionized water and wipe the screen gently. Use a clean, soft, dry lint-free cloth to remove any residue.
To remove grease or other organic contaminants from the display screen, use a 50% to 70% IPA (isopropyl alcohol) solution sparingly. Never use acetone, as it can damage the antistatic hard coating and void the warranty.
WARNING
DISCONNECT SUPPLY BEFORE SERVICING
AVERTISSEMENT
COUPER L’ALIMENTATION AVANT L’ENTRETIEN ET LE DEPANNAGE

Disposal information

Follow your local governing ordinance for proper disposal or recycling of electronic components.
Product Information | vii
AMLCD panel mounted on desk stand
PCI Express
display controller
Dual-link DVI cable
DC power adapter Power cords
Display driver and
Quick reference
calibration software
Options available: VESA wall-mounting kit and Dome Surgery Review Cart. See page 8 for more information.