FP, FR, FX series housing made of glass fibre reinforced technopolymer, self-extinguishing, shock-proof and with double insulation:
FD, FL, FC, FM, FZ series: metal housing, baked powder coating.
FD, FP, FC, FR, FM series: one threaded conduit entry: M20x1.5 (standard)
FX series: two knock-out threaded conduit entries: M20x1.5 (standard)
FZ series: two threaded conduit entries: M20x1.5 (standard)
FL series: three threaded conduit entries: M20x1.5 (standard)
Protection degree: IP67 acc. to EN 60529 with
General data
For safety applications up to:SIL 3 acc. to EN 62061
Safety parameters:
:2,000,000 for NC contacts
B
10D
Service life:20 years
Ambient temperature: -25°C … +80°C
Max. actuation frequency: 1 cycle / 6 s
Mechanical endurance: 1 million operating cycles
Max. actuation speed:0.5 m/s
Min. actuation speed:1 mm/s
Tightening torques for installation:see page 313-324
Cable cross section (flexible copper strands)
Contact blocks
20, 21, 22, 33, 34:min. 1 x 0.34 mm2 (1 x AWG 22)
Contact blocks 18, 8, 9:min. 1 x 0.5 mm2 (1 x AWG 20)
In compliance with standards:
IEC 60947-5-1, EN 60947-5-1, EN 60947-1, IEC 60204-1, EN 60204-1, EN ISO 14119,
EN ISO 12100, IEC 60529, EN 60529, UL 508, CSA 22.2 No.14 .
Approvals:
IEC 60947-5-1, UL 508, CSA 22.2 No.14, GB14048.5-2001.
Compliance with the requirements of:
Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU.
Positive contact opening in conformity with standards:
IEC 60947-5-1, EN 60947-5-1.
cable gland of equal or
higher protection degree
PL e acc. to EN ISO 13849-1
max. 2 x 1.5 mm
max. 2 x 2.5 mm
2
(2 x AWG 16)
2
(2 x AWG 14)
If not expressly indicated in this chapter, for correct installation and utilization of all articles see chapter utilization requirements
from page 313 to page 324.
Electrical dataUtilization category
Thermal current (I
Rated insulation voltage (U
Rated impulse withstand voltage (U
without
connector
Conditional short circuit current:1000 A acc. to EN 60947-5-1
Protection against short circuits: type aM fuse 10 A 500 V
Pollution degree: 3
Thermal current (Ith): 2 A
Rated insulation voltage (U
8-pole
Protection against short circuits: type gG fuse 2 A 500 V
Pollution degree: 3
with M12 connector
): 30 Vac 36 Vdc
i
Description
These rope-operated safety switches are installed on machines or conveyor belts and facilitate the simple shut-down of the machine
from any point and with any pull on the rope.
Provided with self-control function, they allow the constant monitoring of correct functioning, signalling with the opening of the
contacts an eventual loosening or breaking of the rope.
Head with variable orientation
8
For all switches, the head can be adjusted in 90° steps after
removing the four fastening screws.
Protection degree IP67
These devices are designed to be used in the
toughest environmental conditions and they pass
the IP67 immersion test acc. to EN 60529. They
can therefore be used in all environments where maximum protection degree of the housing is required.
Indicator for rope adjustment
Tension
indicator
Area of correct rope
tightening
electrical safety contacts will open.
The switches (head 79 and
80) are provided with a green
ring that shows the area of
the correct tightening of the
rope. The installer has only to
tighten the rope until the black
indicator will be in the middle
of the green area. If the tension (or loosening) on the rope
is so high that the black indicator exits the green area, the
Extended temperature range
These devices are also available in a special
version suitable for an ambient operating temperature range from -40ºC up to +80°C.
They can therefore be used for applications in cold stores, sterilisers
and other equipment with low temperature environments. The special materials used to produce these versions retain their characteristics even under these conditions, thereby expanding the installation
possibilities.
Actuating forces
These switches can be supplied
with reduced hardness internal
springs on request. The force
required to actuate the switch
can thereby be reduced without
changing the actuating path of
the electrical contacts. This is
particularly advantageous for
smaller spans, but must, however, always make use of rope
pulleys.
Features approved by IMQ
Rated insulation voltage (U
Conventional free air thermal current (I
Protection against short circuits:type aM fuse 10 A 500 V
Rated impulse withstand voltage (U
Protection degree of the housing:IP67
MV terminals (screw terminals)
Pollution degree:3
Utilization category:AC15
Operating voltage (U
Operating current (I
Forms of the contact element: Zb, Y+Y, Y+Y+X, Y+Y+Y, Y+X+X
Positive opening contacts on contact blocks 18, 8, 9, 20, 21, 22, 33, 34
In compliance with standards: EN 60947-1, EN 60947-5-1+ A1:2009, fundamental
requirements of the Low Voltage Directive 2014/35/EU.
Please contact our technical department for the list of approved products.
General Catalogue Safety 2017-2018
):500 Vac
i
):400 Vac (50 Hz)
e
):3 A
e
400 Vac
): 10 A
th
imp
): 6 kV
(for contact blocks 20, 21, 22, 33, 34)
4 kV
(for contact blocks 20, 21, 22, 33, 34)
Features approved by UL
Utilization categories Q300 (69 VA, 125-250 Vdc)
A600 (720 VA, 120-600 Vac)
Housing features type 1, 4X “indoor use only”, 12, 13
For all contact blocks use 60 or 75 °C copper (Cu) conductor, rigid or flexible,
wire size 12, 14 AWG. Tightening torque for terminal screws of 7.1 lb in
(0.8 Nm).
In compliance with standard: UL 508, CSA 22.2 No.14
Please contact our technical department for the list of approved products.
How to read travel diagrams All values in the diagrams are in mm
NO opening
0
1.5
4
2
S
NC closing
Ideal rope tension point
Maximum travel
7.5
8.5
11-12
7
8
23-24
Positive opening travel
Example diagram
Closed contact
Open contact
IMPORTANT:
In safety applications, actuate the switch at least up to the
positive opening travel shown in the travel diagrams with symbol . Actuate the switch at least with the positive
opening force, reported in brackets below each article, next
to the actuating force value.
)
Items with code on green background are stock items
181
Accessories See page 299
The 2D and 3D files are available at www.pizzato.com
General Catalogue Safety 2017-2018
S
S
Contact type:
= slow action
L
Contact block
8
L
15.325.1
7
60
5.9
FP 874-M2
8
5.3
5.3x7.3
1NC
14.5
16
15
30.4
36.5
15.325.1
757
FL 874-M2
14.5
6.5
14.5
40
56
18
14.5
31.5
1NC
14.5
15.325.1
7
5.4
16.2
15.2
5.4x7.4
30
40
30.4
38.6
1NC
606.2
FD 874-M2
30
40
Actuating force
Travel diagrams
Initial 63 N…final 83 N (90 N )
page 182 - group 3
3
38.815.3
108.6
51.5
Contact block
L
8
Actuating force
Travel diagrams
FR 874-M2
Initial 63 N…final 83 N (90 N )
page 182 - group 3
Travel diagrams table
Contact block
18
1NO+1NC
8
1NC
9
2NC
20
1NO+2NC
21
3NC
22
2NO+1NC
33
1NC+1NO
34
2NC
Initial 63 N…final 83 N (90 N )
Initial 63 N…final 83 N (90 N )
page 182 - group 3
4.2x7.2
12.2
14.2
24.2
46.1
56
12.2
4.2x7.2
20
22
30.830.8
24.2
14.2
3
38.815.3
111.5
20
22
54.4
30.831.5
1NC
FM 874-M2
Initial 63 N…final 83 N (90 N )
page 182 - group 3
1NC
FX 874-M2
Initial 63 N…final 83 N (90 N )
Group 1Group 2Group 3
016133.5
08.57
1.5
4
S
1.1
7.4
08.5
4
S
7.21.4
08.571.5
08.5
08.571.5
08.57
1.5
1.1
08.5
8
4
S
7.41.1
8
4
S
71.5
8
4
S
7.41.1
4
S
7.4
8
4
71.5
S
8
8
8
8
S
412.6
14.5
8
0
S
133.5
016
3.812.6
8
133.5
S
0163.512.6
8
0
3.812.6
8
8
0
3.812.6
S
133.5
8
0163.812.6
S
14
16
14
14
14
16
14
16
14
page 182 - group 3
15.3
11
20
45
22
40
42
58
page 182 - group 3
0
4
S
6.3
12.2
15.3
4
3
24.2
18.5
14.2
31.7
1NC
3
38.8
102.1
45
FZ 874-M2
20
22
40
42
50
4.2x7.2
18.5
1NC
12.2
14.2
24.2
31.5
Initial 63 N…final 83 N (90 N )
page 182 - group 3
In the rest position (with rope correctly tightened) the
two contacts of con-tact block 8 are both
closed and are acti-
8
8.51
vated respectively by
tightening or loosening
the rope. In order to use this contact block for safety applications it
is necessary to connect the two
contacts in series. For this reason,
in the wiring diagrams the contact block 8 is indicated as 1NC, whereas in travel diagrams both contacts are indicated.
Accessories See page 299 The 2D and 3D files are available at www.pizzato.com
General Catalogue Safety 2017-2018
182
8
Safety rope switch without reset for simple stop
Application examples and max. rope length for switches with longitudinal head
Example
A
VF AF-TR5
FD 1879-M2
2 ÷ 3 m2 ÷ 3 m2 ÷ 3 m2 ÷ 3 m2 ÷ 3 m2 ÷ 3 m2 ÷ 3 m
24 m MAX
VF AF-CA5
VF AF-MR5
FD 1879-M2
VF AF-TR5
VF AF-CA5
VF AF-MR5
VF AF-ME78
Example
B
FD 1879-M2
VF AF-TR5
2 ÷ 3 m2 ÷ 3 m2 ÷ 3 m2 ÷ 3 m2 ÷ 3 m2 ÷ 3 m
18 m MAX
VF AF-CA5
VF AF-MR5
Example
C
Example
D
FD 1879-M2
FD 1879-M2
VF AF-TR5
2 ÷ 3 m2 ÷ 3 m2 ÷ 3 m
12 m MAX
VF AF-MR5
VF F05
6 m MAX
VF AF-CA10
VF AF-IFGR03
VF AF-MR5
Application examples and max. rope length for switches with transversal head
VF AF-TR5
VF AF-CA5
VF AF-MR5
3 m max
FD 1879-M2
FD 874-M2
Example
E
VF F05
VF AF-IFGR03VF AF-IFGR03
VF AF-IFGR03
VF AF-TR8
3 m max
Example
F
Example
G
Example
H
Example
I
FD 1880-M2
FD 1880-M2
FD 1880-M2
FD 1880-M2
VF AF-TR5
VF AF-TR5
VF AF-TR5
3 ÷ 5 m3 ÷ 5 m3 ÷ 5 m3 ÷ 5 m3 ÷ 5 m3 ÷ 5 m3 ÷ 5 m
70 m MAX
VF AF-CA5
3 ÷ 5 m3 ÷ 5 m3 ÷ 5 m3 ÷ 5 m3 ÷ 5 m3 ÷ 5 m
50 m MAX
VF AF-CA5
3 ÷ 5 m3 ÷ 5 m3 ÷ 5 m
35 m MAX
VF AF-MR5
VF F05
16 m MAX
VF AF-MR5
VF AF-MR5
VF AF-ME80
VF AF-CA10
VF AF-IFGR03
VF AF-MR5
3 m max
5 m max
FD 1880-M2
FD 1880-M2
Example
J
VF F05
VF AF-TR8
3 m max
5 m max
VF AF-IFGR03VF AF-IFGR03
VF AF-IFGR03
183
General Catalogue Safety 2017-2018
Maximum spans
30
25
20
15
10
Max. rope length (m)
5
0
0102030405060708090100
Maximum spans for switches with longitudinal head
Temperature difference (°C)
example A
example B
example C-E
example D
8
The max. recommended
spans are indicated in the
diagram as a function of the
temperature fluctuations
(temperature differences)
to which the switch may be
exposed at the point of use.
For instance, with installation of type C and a temperature difference of 30°C,
the max. recommended
rope length is 10 metres.
Maximum spans for switches with transversal head
80
70
60
50
40
Max. rope length (m)
30
20
10
0
0102030405060708090100
Temperature difference (°C)
Important: The above data are guaranteed only using original rope and accessories. See page 185.
example F
example G
example H-J
example I
Adjustment of the switching point
For switches with head 79 and 80: Tighten the rope con-
nected to the switch, until the end of the indicator (1) reaches about the middle of the green ring (2).
General Catalogue Safety 2017-2018
For switches with head 74: Tighten the rope connected
to the switch until the thimble will be at about 4 mm from
the head.
184