Pizzato Prewired position switches FA series Technical Data

2
Main data
Metal housing, cable output from right or
from bottom 4 integrated cable types available Versions with M12 connector from right or from
bottom suitable for saf ety applications Protection degree IP67 4 contact blocks available 24 actuators available
Prewired position switches FA series
Technical data
Housing
Metal housing, coated with baked epoxy powder Version with cable integrated with 5x 0.75 mm2 wires length 2 m, other lengths on request. Versions with 5 poles M12 integrated connector suitable for safety applications Protection degree: IP67
General data
Ambient temperature: See table on page 2/102 Max operating frequency: 3600 operations cycles1/hour Mechanical endurance: 20 million operations cycles Assembling position: any Vibrations holding: 20 gn (10...500 Hz) according to IEC 60068-2-6 Shock holding: 50 gn (1 1 ms) according to IEC 60068-2-27
(1) One operation cycle means two movements, one to close and one to open contacts, as foreseen by IEC 947-5­1 standard.
In conformity with standards:
IEC 60947-5-1, EN 60947-5-1, IEC 60204-1, EN 60204-1, EN 1088, EN ISO 1 2100-1, EN ISO 12100-2, IEC 529, EN 60529, NFC 63-140, VDE 0660-200, VDE 0113, CENELEC EN
50013.
Approvals:
IEC 60947-5-1, UL 508, GB14048.5-2001
1
Markings and quality marks:
Approval IMQ: EI007 Approval UL: E131787 Approval UL: 2007010305229997 Approval EZU: 1010151
Installation for safety applications:
Use only switches marked with the symbol . The safety circuit must always be connected with the NC contacts (normally closed contacts: see “internal connections” on page 2/102) as stated in the standard EN 60947-5-1, encl. K, par. 2. The switch must be actuated with at least
up to the positive opening travel shown in the travels diagrams on page 6/8. T he switc h must be actuated at least with the positiv e opening force, shown in brackets, underneath each article, near the value of the min. force.
If not expressly indicated in this chapt er , for the r ight installation and the cor rect utilization of all ar ticles see requir ements indicated
from page 6/1 to page 6/8.
Electrical data Utilization categories
Thermal current (Ith): 10 A Rated insulation voltage (Ui): 500 VAC 600 VDC Protection against short circuits: fuse 10 A 500 V type aM
with cable
Pollution degree: 3
Thermal current (Ith): 4 A Rated insulation voltage (Ui): 250 VAC 300 VDC Protection against short circuits: fuse 4 A 500 V type gG Pollution degree: 3
with 5 poles
M12 connector
In conformity with requirements requested by:
Low Voltage Directive 2006/95/EC, Machinery Directive 2006/42/EC and Electromagnetic Compatibility 2004/108/EC.
Positive contact opening in conformity with standards:
IEC 60947-5-1, EN 60947-5-1, VDE 0660-206.
Alternate current: AC15 (50...60 Hz) Ue (V) 120 250 400 Ie (A) 6 4 3 Direct current: DC13 Ue (V) 24 125 250 Ie (A) 2,5 0,55 0,27
Alternate current: AC15 (50...60 Hz) Ue (V) 120 250 Ie (A) 4 4 Direct current: DC13 Ue (V) 24 125 250 Ie (A) 2,5 0,55 0,27
page 2/101
General Catalog 2007-2008
Prewired position switches FA series
Data type approved by IMQ and EZU Data type approved by UL
Rated insulation voltage (Ui): 500 VAC / 250 VAC (with connector) Thermal current (Ith): 10 A / 4 A (with connector) Protection against short circuits: fuse 10 A 500 V type aM Protection degree: IP67 MA terminals (seamed clamps) Pollution degree 3 Utilization category: AC15 / DC13 (with connector) Operation voltage (Ue): 400 VAC (50 Hz) / 24 VDC (with connector) Operation current (Ie): 3 A / 2,5 A (with connector) Forms of the contact element: Zb Positive opening of contacts on contact block 45, 46, 48 In conformity with standards: EN60947-1, EN 60947-5-1 and subsequent modifi cations and completions, fundamental requirements of the Low Voltage Directive 73/23 EEC and subsequent modifi cations and completions.
Please contact our technical service for the list of type approved products.
Adjustable levers Overturning levers Rotating heads
In switches with revolving lever it is possi­ble to adjust the lever with 10° steps for the whole 360° range. The positive movement
10°
transmission is always guaran­teed thanks to the particular geo­metrical coupling between the lever and the revolv­ing shaft as pre­scribed for safety applications by the German standard BG-GS-ET-15.
It’s possible to fasten the lever on switches on straight or reverse side, maintaining the positive coupling. In this way it is possible to obtain two different work plans of the lever.
Utilization categories Q300 (69 VA, 125-250 VDC) A600 (720 VA, 120-600 VAC) Data of the housing type 4X, 6 (indoor use only) In conformity with standard: UL 508
Please contact our technical service for the list of type approved products.
According to diff erent v ersions, it is possible to rotate the head in 90° or 180° steps.
2
Internal connections
With cable With M12 connector
Brown Black
Gray Blue
Yellow-Green
Utilization temperatures and approvals
Cable code Cable features
N G U
H
PVC H05VV-F, fi xed laying
Not spreading the fl ame EN 50265-2-1
PVC S05VV-F,
Not fl ame-spreading CEI 20-22 II
fi xed laying
Polyurethane H05BQ-F, fi xed laying
Oil-resistant IEC 60811-2-1
Polyurethane without halogens,
Without halogens IEC 60754-1 Oil-resistant IEC 60811-2-1 Self-extinguishing IEC 60332-1, IEC 60332-2 Not fl ame-spreading IEC 60332-3 Gas emission reduced IEC 61034-1 Copper class 6 (IEC 228)
dynamic laying
5 poles M12 safety connectors
The long experience of Pizzato Elet trica has lead to the realization of the fi rst 5-poles connector integrated in a safety switch complying with the requirements of standard IEC 947-5-1. Its high insulation voltage Ui 250 V A C allows to mark it as suitable for safety applications
.
Available on request
Switches FA series standard
Fixed laying
Tmin Tmax Tmin Tmax Tmin Tmax Tmin Tmax
cable
versions
Dynamic laying
cable
-25 °C +70 °C - - - - - - CE, IMQ, UL, CCC
-25 °C +70 °C - - - - - - CE
-25 °C +70 °C - - -35 °C +80 °C - - CE, IMQ, CCC
-25 °C +80 °C -25 °C +80 °C -35 °C +80 °C -35 °C +80 °C CE, UL
Switches FA series extended
temperature versions
Fixed laying cable
Dynamic laying
cable
Approvals of
switches with
integrated cable
Connector
code
K
Available on request
Approvals of
switches with
integrated connector
Connector features
Switches FA series standard
versions
Tmin Tmax Tmin Tmax
Switches FA series extended
temperature versions
5 poles M12 connector -25 °C +80 °C -35 °C +80 °C CE, IMQ, UL, CCC
General Catalog 2007-2008