Pizzato CS AR-91 Data Sheet

10A
Safety module CS AR-91
Technical data
Housing
Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94 Protection degree: IP40 (housing), IP20 (terminal strip) Dimensions: see page 295, design A
General data
SIL CL: up to SIL CL 3 acc. to EN 62061 Performance Level (PL): up to PL e acc. to EN ISO 13849-1 Safety category: up to cat. 4 acc. to EN ISO 13849-1 Safety parameters: see page 349 Ambient temperature: -25°C…+55°C Mechanical endurance: >10 million operating cycles Electrical endurance: >100,000 operating cycles Pollution degree: external 3, internal 2 Impulse withstand voltage (U Rated insulation voltage (U Overvoltage category: II Weight: 0.2 kg
): 4 kV
imp
): 250 V
i
Module for emergency stops, end position monitoring for movable guards and magnetic safety sensors
Main features
•For safety applications up to SIL 3/PL e
•Choice between automatic start, manual start
•Connection of input channels of opposite potentials
•Reduced housing width of 22.5 mm
•Output contacts:
2 NO safety contacts, 1 NO opto-decoupled auxiliary contact
•Supply voltage: 24 Vac/dc
•Insensitive to voltage dips
Utilization categories
Alternating current: AC15 (50…60 Hz) Ue (V) 230 Ie (A) 3 Direct current: DC13 (6 oper. cycles/min.) Ue (V) 24 Ie (A) 4
Quality marks and certificates:
IMQ certificate of conformity no. 340
(EN 81‑20:2014; EN 81‑50:2014; EN 81‑1:1998+A3:2009;
EN 81‑2:1998+A3:2009)
EC type examination certificate: IMQ CP 432 DM
(Machinery Directive)
EC type examination certificate: IMQ 236
(Machinery Directive)
CCC approval: 2013010305640211 EAC approval: RUC-IT.AД35.В.00454
Compliance with the requirements of:
Low Voltage Directive 2014/35/EU, Machinery Directive 2006/42/EC, EMC Directive 2014/30/EU
Supply
Rated supply voltage (U Max. DC residual ripple in DC: 10%
): 24 Vac/dc; ±15%; 50…60 Hz
n
Power consumption AC: < 5 VA Power consumption DC: < 2.5 W
Control circuit
Protection against short circuits: PTC resistance, Ih=0.5 A PTC response time: Response time > 100 ms, release time > 3 s Maximum resistance per input:
50 Current per input: < 40 mA Min. duration of start impulse t Response time t Release time t Release time in absence of power supply t Simultaneity time t Response time starting from application of the supply: < 300 ms
: < 120 ms
A
: < 15 ms
R1
: unlimited
C
: > 50 ms
MIN
: < 65 ms
R
Auxiliary signalling circuit
Auxiliary output (Y43-Y44): 1NO opto-decoupled Rated operating voltage (U Rated operating current (I Rated impulse withstand voltage (U Release time t
: < 1 ms
R2
): 24 Vdc
e
): 25 mA
e
): 4 kV
imp
In compliance with standards:
EN 60204-1, EN ISO 13855, EN 1037, EN ISO 12100, EN ISO 13850, EN 60529, EN 61000-6-2, EN 61000-6-3, EN 61326-1, EN 60664-1, EN 60947-1, EN ISO 13849-1, EN ISO 13849-2, EN 62061, UL 508, CSA C22.2 n° 14-95
Output circuit
Output contacts: 2 NO safety contacts, Contact type: forcibly guided Material of the contacts: gold-plated silver alloy Maximum switching voltage: 230/240 Vac; 300 Vdc Max. current per contact: 6 A Conventional free air thermal current (Ith): 6 A Max. total current Σ Ith
2
: 36 A
2
Minimum current: 10 mA Contact resistance:
100 m External protection fuse: 4 A type F
The number and the load capacity of output contacts can be increased by using expansion modules or contactors. See page 241-250.
Code structure
CS AR-91V024
Connection type
V
Screw terminals
M Connector with screw terminals
X Connector with spring terminals
215
Supply voltage
024
24 Vac/dc
Features approved by UL
Rated supply voltage (Un): 24 Vac/dc; 50…60 Hz Power consumption AC: < 5 VA Power consumption DC: < 2.5 W Maximum switching voltage: 230 Vac Max. current per contact: 6 A Utilization category C300
Notes:
- Use 60 or 75 °C copper (Cu) conductors, rigid or flexible, wire size 30-12 AWG.
- Tightening torque for terminal screws of 5-7 lb in.
- Only for 24 Vac/dc versions: power supply only with class 2 sources or with limited voltage and energy. (Supply from Remote Class 2 Source or limited voltage limited energy).
General Catalogue Safety 2017-2018
K1
K2
A1
S11
S12
S33
S34
13
23A2S21
S35
S22
14
24
Y43
Y44
LED CH1
LED CH2
A11323
A21424
S11
S12
Y43
Y44
S33
S21
S22
S35
S34
PWR
CH1
CH2
Safety module CS AR-91
ITALY
Internal block diagram
LED
PWR
LOGIC
Voltage dips, short interruptions and voltage variations
The CS AR-91 safety module has a built-in voltage drop sensor which serves to protect and safeguard the internal state of the safety relays, in the event of dips or short voltage interruptions. This is to prevent unwanted switching states in relation to the state of the inputs from occurring. When voltage is restored, the device continues to operate with a switching state that is consistent with the input signals. The safety module retains its normal function during voltage dips and brief interruptions; for longer voltage interruptions, the safety outputs open and reset themselves automatically during an automatic start if voltage is restored or – in the case of a manual or monitored start – require that the system be reset by the operator.
LOGIC
Function diagramsPin assignment
Configuration with automatic start
t
t
R
R
2
tCt
A
Configuration with monitored start
Configuration with manual start
t
A
Legend:
t
: Min. duration of start impulse
MIN
tC: simultaneity time tA: response time
2
tCt
A
t
t
R1
R1
t
t
R
R
2
2
t
A
t
t t
t
t
t
R2
R2
t
R1
R1
A
R1
R1
t
A
t
t
R
R
2
2
t
A
t
t
R1
R1
t
t
R
R
2
2
t
MINtA
t
t
R1
R1
t
t
R2
R2
t
t
t
MIN
R1
R1
t
: release time
R1
: release time in absence of
t
R
t
t
R
t
R
power supply
R
10A
A1/A2
S11/S12
S21/S22
13/14, 23/24
Y43/Y44
A1/A2
S11/S12
S21/S22
S33/S34 (START)
13/14, 23/24
Y43/Y44
A1/A2
S11/S12
S21/S22
S33/S34 (START)
13/14, 23/24
Y43/Y44
Input configuration
The diagram does not show the exact position of the terminals in the product
Automatic start
With regard to the indica­ted diagrams, bridge the start button between S33 and S34 in order to acti­vate the automatic start module.
S34 S34
Notes: The configurations with one channel are obtained taking into consideration the S11/ S12 input only. In this case it is necessary to consider time tR1 referred to input S11/S12, time tR referred to the supply, time tA referred to input S11/S12 and to the start, and time t
Input configuration with magnetic sensors
2 channels
L / +
A1
CS AR-91
S21 S22
S12
S11
S35
S33
S34
A2
N / -
Monitored start
With regard to the indica­ted diagrams, remove the
S21
connection between S22 and S35 in order to acti­vate the monitored start module.
S35
S22
S21
S22
MIN
S35
referred to the start.
Monitoring of movable guards and magnetic safety sensors
The safety module can monitor emergency stop circuits, control circuits for movable guards as well as magnetic safety sensors. Replace the emergency stop contacts with switch contacts or sensor con­tacts.
The sensors can only be used in 2-channel confi­guration.
General Catalogue Safety 2017-2018
Application examples See page 251
216