Pizzato CS AR-40, CS AR-41 Data Sheet

Page 1
10A
Safety module CS AR-40 / CS AR-41
Module for emergency stops and end position monitoring for movable guards
Main features
•For safety applications up to SIL CL 2/PL d
(CS AR-40 only) or monitored start (CS AR-41 only)
•Reduced housing width of 22.5 mm
•2 NO safety contacts
•Supply voltage:
24 Vac/dc
Utilization categories
Alternating current: AC15 (50…60 Hz) Ue (V) 230 Ie (A) 3 Direct current: DC13 (6 oper. cycles/min.) Ue (V) 24 Ie (A) 4
Quality marks and certificates:
EC type examination certificate: IMQ CP 432 DM UL approval: E131787
CCC approval: 2013010305640211 EAC approval: RUC-IT.AД35.В.00454
Compliance with the requirements of:
Low Voltage Directive 2014/35/EU, Machinery Directive 2006/42/EC, EMC Directive 2014/30/EU
Technical data
Housing
Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94 Protection degree: IP40 (housing), IP20 (terminal strip) Dimensions: see page 296, design D
General data
SIL CL: up to SIL CL 2 acc. to EN 62061 Performance Level (PL): up to PL d acc. to EN ISO 13849-1 Safety category: up to cat. 2 acc. to EN ISO 13849-1 Safety parameters: see page 349 Ambient temperature: -25°C…+55°C Mechanical endurance: >10 million operating cycles Electrical endurance: >100,000 operating cycles Pollution degree: external 3, internal 2 Impulse withstand voltage (U Rated insulation voltage (U Overvoltage category: II Weight: 0.2 kg
Supply
Rated supply voltage (U Max. DC residual ripple in DC: 10% Supply voltage tolerance: ±15% of U Power consumption AC: < 5 VA Power consumption DC: < 2 W
Control circuit
Protection against short circuits: PTC resistance, Ih=0.5 A PTC times: Response time > 100 ms, release time > 3 s Maximum resistance per input: Current per input: 70 mA (typical) Min. duration of start impulse t Response time t Release time in absence of power supply t Simultaneity time t
: < 50 ms
A
: unlimited
C
In compliance with standards:
EN 60204-1, EN ISO 13855, EN 1037, EN ISO 12100, EN ISO 13850, EN 60529, EN 61000-6-2, EN 61000-6-3, EN 61326-1, EN 60664-1, EN 60947-1, EN ISO 13849-1, EN ISO 13849-2, EN 62061, UL 508, CSA C22.2 n° 14-95
Output circuit
Output contacts: 2 NO safety contacts Contact type: forcibly guided Material of the contacts: silver alloy Maximum switching voltage: 230/240 Vac; 300 Vdc Max. current per contact: 6 A Conventional free air thermal current (Ith): 6 A Max. total current Σ Ith
2
Minimum current: 10 mA Contact resistance: External protection fuse: 4 A
The number and the load capacity of output contacts can be increased by using expansion modules or contactors. see page 241-250.
): 4 kV
imp
): 250 V
i
): 24 Vac/dc; 50…60 Hz
n
n
50
: > 100 ms
MIN
: < 105 ms
R
: 36 A
2
100 m
Code structure
CS AR-40V024
Start mode
40
manual or automatic start
41
monitored start
Connection type
V
Screw terminals
M Connector with screw terminals
X Connector with spring terminals
211
Supply voltage
024
24 Vac/dc
Stock items
CS AR-40V024
Features approved by UL
Rated supply voltage (Un): 24 Vac/dc; 50…60 Hz Power consumption AC: < 5 VA Power consumption DC: < 2 W Maximum switching voltage: 230 Vac Max. current per contact: 6 A Utilization category C300
Notes:
- Use 60 or 75 °C copper (Cu) conductors, rigid or flexible, wire size 30-12 AWG.
- Tightening torque for terminal screws of 5-7 lb in.
- Only for 24 Vac/dc versions: power supply only with class 2 sources or with limited voltage and energy. (Supply from Remote Class 2 Source or limited voltage limited energy).
General Catalogue Safety 2017-2018
Page 2
K1
K2
A1
S33
S34
13
23
24
14
A2
LED CH1
LED CH2
S33/S34 (START)
S33/S34 (START)
Safety module CS AR-40 / CS AR-41
Pin assignment
A1 13 23 S33
ITALY
PWR
CH1
CH2
Function diagrams
1-channel configuration with automatic start (CS AR-40)
t
A
1-channel configuration with manual start (CS AR-40)
t
t
R
A
t
R
10A
CH1: A1
13/14, 23/24
A2 14 24 S34
Internal block diagram
L / +
LED
PWR
N / -
LOGIC LOGIC
t
A
t
t
MIN
R
t
R
1-channel configuration with monitored start (CS AR-41)
t
t
A
MIN
Legend:
t
: Min. duration of start impulse
MIN
tA: response time tR: release time in absence of power supply
t
R
t
A
t
R
CH1: A1
13/14, 23/24
CH1: A1
13/14, 23/24
Input configuration
Emergency stop circuits
One channel input configuration with manual start
L / +
S33
A1
CS AR-40
S34
A2
N / -
The diagram does not show the exact position of the terminals in the product
Automatic start
With regard to the indicated diagram, bridge the start button between S33 and S34 in order to activate the automatic start module.
Items with code on green background are stock items
General Catalogue Safety 2017-2018
S34 S34
Monitored start
Use module CS AR-41 with the circuit diagrams for manual start.
Movable guard monitoring
The safety module can monitor emergency stop circuits and control circuits for movable guards. Replace the emergency stop contacts with the switch contacts.
212