10A
Safety module CS AR-08
Module for emergency stops, end
position monitoring for movable guards,
semiconductor outputs (e.g. light
barriers) and magnetic safety sensors
Main features
•For safety applications up to SIL CL 3/PL e
•Input with 1 or 2 channels
•Choice between automatic start, manual start
or monitored start
•Can be connected to semiconductor outputs
(e.g. light barriers), to electromechanical
contacts or to magnetic safety sensors
•Output contacts:
2 NO safety contacts
•Supply voltage:
12 Vdc, 24 Vac/dc, 120 Vac, 230 Vac
•Possibility of parallel reset of several modules
Utilization categories
Alternating current: AC15 (50…60 Hz)
Ue (V) 230
Ie (A) 3
Direct current: DC13 (6 oper. cycles/min.)
Ue (V) 24
Ie (A) 4
Quality marks:
EC type examination certificate: IMQ CP 432 DM
UL approval: E131787
CCC approval: 2013010305640211 TÜV
SÜD approval: Z10 10 09 75157 002
EAC approval: RUC-IT.AД35.В.00454
Compliance with the requirements of:
Low Voltage Directive 2014/35/EU,
Machinery Directive 2006/42/EC,
EMC Directive 2014/30/EU
Code structure
CS AR-08V024
Connection type
V
Screw terminals
M Connector with screw terminals
X Connector with spring terminals
Stock items
CS AR-08V024
Technical data
Housing
Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94
Protection degree: IP40 (housing), IP20 (terminal strip)
Dimensions: see page 295, design A
General data
SIL CL: up to SIL CL 3 acc. to EN 62061
Performance Level (PL): up to PL e acc. to EN ISO 13849-1
Safety category: up to cat. 4 acc. to EN ISO 13849-1
Safety parameters: see page 349
Ambient temperature: -25°C…+55°C
Mechanical endurance: >10 million operating cycles
Electrical endurance: >100,000 operating cycles
Pollution degree: external 3, internal 2
Impulse withstand voltage (U
Rated insulation voltage (U
Overvoltage category: II
Weight: 0.3 kg
Supply
Rated supply voltage (U
Max. DC residual ripple in DC: 10%
Supply voltage tolerance
24 Vac/dc, 120 Vac, 230 Vac:
Supply voltage tolerance 12 Vdc: -10% … +15% of U
Power consumption AC: < 5 VA
Power consumption DC: < 2 W
Control circuit
Protection against short circuits: PTC resistance, Ih=0.5 A
PTC times: Response time > 100 ms, release time > 3 s
Maximum resistance per input:
Current per input: 30 mA (70 mA)* (typical)
Min. duration of start impulse t
Response time t
Release time t
Release time in absence of power supply t
Simultaneity time t
: < 150 ms ( 220 ms)*
A
: < 20 ms (15 ms)*
R1
: unlimited
C
In compliance with standards:
EN 60204-1, EN ISO 13855, EN 1037, EN ISO 12100, EN ISO 13850, EN 60529,
EN 61000-6-2, EN 61000-6-3, EN 61326-1, EN 60664-1, EN 60947-1, EN ISO 13849-1,
EN ISO 13849-2, EN 62061, UL 508, CSA C22.2 n° 14-95
Output circuit
Output contacts: 2 NO safety contacts,
Contact type: forcibly guided
Material of the contacts: gold-plated silver alloy
Maximum switching voltage: 230/240 Vac; 300 Vdc
Max. current per contact: 6 A
Conventional free air thermal current (Ith): 6 A
Max. total current Σ Ith
2
Minimum current: 10 mA
Contact resistance:
External protection fuse: 4 A
The number and the load capacity of output contacts can be increased by using expansion modules or
contactors. see page 241-250.
Supply voltage
U12
12 Vdc
024
24 Vac/dc
120
120 Vac
230
230 Vac
): 4 kV
imp
): 250 V
i
): 12 Vdc
n
24 Vac/dc; 50…60 Hz
120 Vac; 50…60 Hz
230 Vac; 50…60 Hz
±15% of U
50 (15 )*
: > 200 ms (100 ms)*
MIN
: < 150 ms (50 ms)*
R
: 36 A
2
100 m
Features approved by UL
Rated supply voltage (Un): 24 Vac/dc, 50…60 Hz, 120 Vac;
50…60 Hz: 230 Vac; 50…60 Hz
Power consumption AC: < 5 VA
Power consumption DC: < 2 W
Maximum switching voltage: 230 Vac
Max. current per contact: 6 A
Utilization category: C300
- Use 60 or 75 °C copper (Cu) conductors, rigid or flexible, wire size 30-12 AWG.
- Tightening torque for terminal screws of 5-7 lb in.
- Only for 24 Vac/dc versions: power supply only with class 2 sources or with
limited voltage and energy. (Supply from Remote Class 2 Source or limited
voltage limited energy).
Features approved by TÜV SÜD
Rated supply voltage (Un): 24 Vac/dc, ± 15%, 120 Vac ± 15%,
230 Vac ± 15%
Power consumption: 5 VA max AC, 2 W max DC
Rated operating current (max.): 4 A
Maximum switching load (max.): 1380 VA
Ambient temperature: -25°C … +55°C
Storage temperature: -25 °C … + 70°C
Protection degree: IP40 (housing), IP20 (terminal strip)
In compliance with standards: 2006/42/EEC Machine Directive,
EN ISO 13849-1 (up to cat. 4 PL e), EN 50178:1997, EN 60947-5-3/
A1:2005, EN 61508-1:1998 (SIL CL 1-3), EN 61508-2:2000 (SIL CL
1-3), EN 61508-4:1998 (SIL CL 1-3), IEC 62061:2005 (SIL CL 3)
n
n
* Version CS AR-08•U12
203
General Catalogue Safety 2017-2018

Safety module CS AR-08
Pin assignment
ITALY
Function diagrams
Configuration with automatic start
tCt
Configuration with monitored start
tR1tCt
A
t
A
A
t
tAt
R1
10A
A1/A2
S11/S12 (+/S12)
S21/S22 (+/S52)
13/14, 23/24
t
t
R1
A
t
R1
MINtA
t
R
A1/A2
S11/S12 (+/S12)
S21/S22 (+/S52)
S33/S34 (START)
13/14, 23/24
t
R
Internal block diagram
L / +
LED
PWR
LOGIC LOGIC
N / -
Input configuration
Semiconductor outputs (e.g. light barriers)
Input configuration with manual start
1 channel 2 channels
+
24 VDC
-
S21 S22
L / +
A1
S21 S22
The diagram does not show the exact position of the terminals in the product
Items with code on green background are stock items
OSSD
A1
S12
CS AR-08
S35
S33
S52
S34
A2
Emergency stop circuits
Input configuration with manual start
1 channel 2 channels
S11
CS AR-08
S12
S35
S33
S31
S34
A2
N / -
+
24 VDC
-
A1
S21 S22
L / +
A1
S21 S22
OSSD1 OSSD2
S12
CS AR-08
S35
S11
CS AR-08
Configuration with manual start
A1/A2
S11/S12 (+/S12)
S21/S22 (+/S52)
S33/S34 (START)
13/14, 23/24
t
A
Legend:
t
: Min. duration of start impulse
MIN
tC: simultaneity time
tA: response time
Notes:
The configurations with one channel are obtained taking into consideration the CH1
input only. In this case it is necessary to consider time t
time t
referred to the supply, time tA referred to input CH1 and to the start, and
R
time t
MIN
tR1t
A
referred to the start.
t
t
R1
MIN
t
: release time
R1
: release time in absence of
t
R
t
R
power supply
referred to input CH1,
R1
Automatic start
With regard to the
indicated diagrams, bridge
the start button between
S33 and S34 in order to
activate the automatic
start module.
S33
S52
S34 S34
Monitored start
S34
A2
With regard to the
indicated diagrams,
S21
S21
remove the connection
between S22 and S35
in order to activate the
monitored start module.
S22
S35
S22
S35
Monitoring of movable guards and magnetic safety sensors
The safety module can
monitor emergency stop
circuits, control circuits for
S12
S33
S31
movable guards as well as
magnetic safety sensors.
Replace the emergency
S35
S34
A2
stop contacts with switch
contacts or sensor contacts.
N / -
The sensors can only be
used in 2-channel configuration.
Application examples See page 251
General Catalogue Safety 2017-2018
204