Pitco Frialator SSH55T User Manual

Project_________________________
Item No._________________________
60W(R), 75(R) Gas Fryers
STANDARD FRYER FEATURES & ACCESSORIES
Tank - stainless steel construction Cabinet - stainless front, door and sides Patented Solstice Burner Technology, No blower or
ceramics
Patented Self Cleaning Burner & Down Draft Protection Solid State T-Stat with melt cycle and boil out mode Matchless Ignition with DVI drain valve interlock High Temperature safety limit switch Heavy duty 3/16” bottom door hinge 1 ¼” (3.2 cm) Full port drain valve for fast draining Separate Manual gas shutoffs, for front servicing Integrated flue deflector 10”(25.4cm) adjustable legs, easier access to clean Tube rack, allows crumbs & debris into cool zone Removable basket hanger, requires no tools Drain Line Clean out rod Fryer cleaner sample packet Choice of basket options :
2 - Twin Baskets
1 - Full Basket (not available on 55T or Basket Lifts)
STANDARD FILTER FEATURES & ACCESSORIES
Easy Two Step Filtering Extra Large 3” (7.6cm) curved drain spout virtually eliminates
splashing and swivels for oil disposal
8 gpm filter pump for fast refill times Self Aligning filter connection for effortless hookup Rear oil return for bottom cleaning Filter pan is stainless with rear wheels for easy handling Filter pan lid is self storing and out of the way Fryer cleaning brush Fryer crumb scoop Filter shovel scoop Filter paper envelope starter pack Filter powder sample
SFSSH55(R), 55T(R), 60(R),
SSFSSH75
SSFSSH55T W/Digital rear casters
SSFSSH60W W/Digital, front/rear casters
** ENERGYSTAR ® Models SSFSSH55
W/Computer and Basket Lift, front/rear casters
Quantity_________________________
HIGH EFFICIENCY SERIES OF GAS FRYERS
For Space Saving Filtering and Energy Saving High Production Frying specify Pitco Model SFSSH55(R), SFSSH55T(R), SFSSH60(R), SFSSH60W(R), SFSSH75(R), tube fired gas fryers with Solstice Supreme Burner Technology which provides very dependable atmospheric heat transfer and fuel saving ENERGYSTAR power blowers. This patented atmospheric burner system with its long lasting alloy heat baffles reaches up to 70% thermal efficiency and delivers lower flue temperatures. Patented Self Cleaning Burner goes through a daily 30 second cleaning cycle to keep your burners tuned to operate in the most energy efficient manner. Ventilation troubles are virtually eliminated with the Patented Down Draft Protection that safely monitors your fryer, making this a low maintenance, highly reliable fryer. Simple two step filtering keeps oil filtering convenient and swift to keep oil clean to produce fresher products and to help maximize oil life and profits.
SOLOFILTER MODELS AVAILABLE 55 Series (40-50 lbs, 14” x 14” fry area)
**
®
performance without the need for complex
SFSSH55** (80 Kbtu/hr, 23.4 kW, 88 MJ) SFSSH55R (100 Kbtu/hr, 29.3 kW, 105 MJ)
55T Twin Vat Series (20-25 lbs, 7” x 14” fry area/side)
SFSSH55T (40K btu/hr, 11.7 kW, 44 MJ /side) SFSSH55TR (50K btu/hr, 14.6 kW, 53 MJ /side)
60 Series (50-60 lbs, 14” x 18” fry area)
SFSSH60** (80K btu/hr, 23.4 kW, 88 MJ) SFSSH60R (100K btu/hr, 29.3 kW, 105 MJ)
60W Series (50-60 lbs, 18” x 14” fry area)
SFSSH60W** (100K btu/hr, 29.3 kW, 110 MJ) SFSSH60WR (125K btu/hr, 36.6 kW, 132 MJ)
75 Series (75 lbs, 18” x 18” fry area)
SFSSH75** (105K btu/hr, 30.8 kW, 116 MJ) SSH75R (125K btu/hr, 36.6 kW, 132 MJ)
OPTIONS & ACCESSORIES (AT ADDITIONAL COST)
Digital Controller (2 times w/melt cycle)
Intellifry I-12 Computer
Backup thermostat (only on Digital and I-12 computer) Basket Lift (must be ordered with Digital Control or Computer)
(To meet AGA/CGA/CSA specification, must be ordered with casters & installed with flexible gas hose w/restraining cable)
Stainless Steel back (not available with basket lift)
10”(25.4cm) adjustable rear fixed rigid casters only.
  10” (25.4cm) adjustable rear non locking and front locking
rigid casters
Flexible gas hose with disconnect and restraining cable Tank cover 3-Triple Baskets (not available on 55T or Basket Lifts) Consult Factory for other basket configurations
Splash Guard reversible (L/R) 6" 8" 12" 18"
Work shelves call factory for specifications and availabilty. Fish Grids (not available on 55T)
SoloFilter System Options
Filter flush hose Filter pump heaters Paperless Filter Waste Oil Management Filter Crumb Catch
Institutional Prison security package BNB Dump Station, see BNB spec sheet L10-269 for details SPINFRESH See Spec Sheet L10-524 for details
(12 elastic timers w/melt cycle & boil out)
SOLOFILTER SOLSTICE SUPREME (SSH) SERIES SFSSH55(R), 55T(R), 60(R), 60W(R), 75(R)
Pitco Frialator, Inc P.O. Box 501, Concord, NH 03302-0501 509 Route 3A, Bow, NH 03304
603-225-6684 FAX: 603-225-8497 www.pitco.com
L10-267 Rev 5 04/12 Printed in the USA
SOLOFILTER SOLSTICE SUPREME SFSSH55(R), 55T(R), 60(R), 60W(R), 75(R)
)
(
)
(
(
g
(
)
(
)
(
)
(
)
)
(
)
)
(
)
(
)
)
A
48 11/32 [122.8] B C
B
SSH55 (R)
SSH55T (TR)
15 5/8 [39.7]
4 1/4 [10.8]
SSH75 (R)
52 11/32 [132.9]
19 5/8 [49.8]
6 1/4 [15.9]
SPACE REQUIRED TO
REMOVE FILTER PAN
SSH60 (R)
48 11/32 [122.8]
15 5/8 [39.7]
4 1/4 [10.8]
32 [81.4]
MINIMUM AISLE
SSH60W (R)
52 11/32 [132.9]
19 5/8 [49.8]
6 1/4 [15.9]
38 11/32 [97.4]
34 15/32 [87.5]
INTEGRAL FLUE DEFLECTOR
OPTIONAL BASKET LIFT
11/16
[1.7]
3/4 INCH GAS CONNECTION (CE 3/4 INCH BSP ADAPTOR
G
ADDS 1 1/2 [3.8] TO CONNECTION)
6 FOOT (183 CM) POWER CORD (NEMA 5-15 PLUG
P
115VAC UNITS ONLY)
P
OPTIONAL
DIGTIAL
SOLID STATE
THERMOSTAT
G
C
14 x 18 in
SSH60W, 60WR
SSH75, 75R
For Models
SSH55,55T,60 (R)
SSH60W,75 (R)
Pan Oil Capacity
66 Lbs (29.9 kg)
90 Lbs (41 kg)
18 x 14 in 18 x 18 in
Model -Solo Filter Shipping Weight Shipping Cube
SSH55, SSH55R 358 Lbs (162 kg) 458 Lbs (208 kg)
SSH55T, SSH55TR
380 Lbs (172 kg)
SSH60, SSH60R 376 Lbs (170 kg 59 x 23 x 44 in (149.8 x 58.4 x 111.7 cm)
SSH60W,SSH60WR 425 Lbs (193 kg)
SSH75, SSH75R 425 Lbs (193 kg)
GAS SYSTEM REQUIREMENTS
Gas Type
Natural
Propane
* Check plumbin
Store Supply Pressure *
7 - 10" w.c.(17.4 mbars/ 1.7 kPa)
11 - 13" w.c.(27.4 mbars/ 2.7 kPa)
/ gas codes for proper gas supply line sizing to sustain burner pressure when all gas appliances are full on.
Combustible material Non-Combustible material
32"
(76.2 cm)
6"
(15.25 cm)
6" (15.2cm) 6" (15.2cm)
Provide Pitco SoloFilter Solstice Supreme Model (SSH xxx) tube fired high efficiency, high production gas floor fryer/filter with EnergyStar performance. Fryer shall be xx-xx lbs oil capacity, xxx Kbtu/hr, xx” by xx” fry area, stainless peened tank, stainless front, door, sides. Blower Free atmospheric burner system with up to 70% thermal efficiency, self cleaning burners, down draft protection, matchless ignition, drain valve interlock, behind the door solid state t-stat with melt and boil mode (or specify optional digital controller or computer controls), separate gas shut off, 3/4" npt rear gas connect, recessed cabinet back, 1-1/4" Ful l port drain, 3/16" bottom hinge, 10” adjustable legs, manual reset
SOLOFILTER SOLSTICE SUPREME (SSH) SERIES SFSSH55(R), 55T(R), 60(R), 60W(R), 75(R)
high limit. Drain Line shall be 3" (7.6 cm) diameter with a swivel drain spout for oil disposal. Filter pickup assembly use envelope filter paper. 8 GPM, 60 hz (25.4 LPM 50 hz) filter pump. Filter piping to be self aligning, filter lid integral to cabinet, filter pan to have rear casters for portability, two step filter process. Provide options and accessories as follows:
IN [CM]
10 [25.4]
NOM.
21 7/8 [55.6]
INDIVIDUAL FRYER SPECIFICATIONS
Cook Depth Oil CapacityModel Frying Area
14 x 14 in
7 x 14 in
35.6 x 35.6 cm
35.6 x35.6cm
35.6 x 45.7 cm
45.7 x 35.6 cm
45.7 x 45.7 cm
3-1/4 - 5 in 3-1/4 - 5 in (8.3 -12.7 cm 3-1/4 - 5 in 3-1/4 - 5 in (8.3 -12.7 cm 3-1/4 - 5 in (8.3 -12.7 cm
FILTER SPECI FICATIONS
Filter Pump Rated FlowFilter Pump Motor
1/3 HP 50/60 Hz
8 GPM (30.3 LPM) @ 60 Hz
6.7 GPM (25.4 LPM) @ 50 Hz
FRYER SHIPPING INFORMATION (Approximate)
Add for Each Bsk/Lifts
480 Lbs 467 Lbs
218 kg) 212 kg)
525 Lbs (238 kg)
525 Lbs (238 kg)
Burner Manifold Pressure
4" w.c. (10 mbars / 1 kPa)
10" w.c. (25mbars/2.4 kPa)
Shipping Crate Size H x W x L
CLEARANCES
Sides min.Sides min. Rear min.
0"
Rear min.
0"
SHORT FORM SPECIFICATIONS
55 13/32
[140.7]
NOM.
G
8.3 -12.7 cm
P
47 1/8
[119.7]
NOM.
4 13/32 [11.2]
40 - 50 Lbs (18 - 23 kg)SSH55, 55R
A
20 - 25 Lbs (9 -11 kg)SSH55T, 55TR per side
8.3 -12.7 cm
50 - 60 Lbs (23 - 27 kg)SSH60, 60R 50 - 60 Lbs (23 - 27 kg)
75 Lbs (34 kg)
Filter Media Paper Envelope
10 x 20-1/2 in
25.4 x 52.1 cm
14 x 22 in (35.6 x 55.9 cm
3
34.6 ft
. (1.0m3 )
ELECTRIC SYSTEM REQUIREMENTS (50/60 hz)
Amps # of Cord
Fryer/Filter
For heaters add 0.43A to 115V or .24A to 208/230-240V
1
208 / 220-240V 115V
6.16.1
Fryer Flue AreaFront min. Floor min.
Do not block / restrict flue gases from flowing into hood
or install vent hood drains over the flue.
TM
Pitco Frialator, Inc  P.O. Box 501, Concord, NH 03302-0501 509 Route 3A, Bow, NH 03304
603-225-6684 FAX: 603-225-8497 www.pitco.com
We reserve the right to change specifications without notice and without incurring any obligation for equipment previously or subsequently sold.
L10-267 Rev 5 04/12 Printed in the USA
Loading...