Model SSH, SSH55T and SSH75
Solstice Supreme Gas Fryer
SSH75 with optional
Computer, Basket
Lift and casters
**
STANDARD FEATURES & ACCESSORIES
Tank - stainless steel construction
Cabinet - stainless front, door and sides
Solstice Burner Technology, No blower or ceramics
Self Cleaning Burner & Down Draft Protection
Solid State T-Stat with melt cycle and boil out mode
Matchless Ignition with DVI drain valve interlock
Heavy duty 3/16” bottom door hinge
1 ¼” (3.2 cm) Full port drain valve for fast draining
Separate Manual gas shutoffs, for front servicing
Integrated flue deflector
9” (22.9 cm) adjustable legs, easier access to clean
Tube rack, allows crumbs & debris into cool zone
Removable basket hanger, requires no tools
Drain Line Clean out rod
Drain Extension
Fryer cleaner sample packet
Choice of basket options :
Twin Baskets
Full Basket
CONTROLS
Matchless Ignition automatically lights the pilot when the
power is turned on and saves you money during off times.
Solid State Thermostat with melt cycle and boil out mode.
Optional: Digital Controller with displaying 2 product timer
Optional: I-12 Computer with 12 product timer and flex time
DVI drain valve interlock safety system turns the heat off
preventing the oil from scorching and overheating.
Integrated gas control safety valve controls gas flow.
Temperature limit switch safely shuts off all heat if the
upper temperature limit is exceeded.
Project_________________________
Item No._________________________
Quantity_________________________
HIGH EFFICIENCY SERIES OF GAS FRYERS
For Energy Saving High Production frying specify Pitco
Model SSH55, SSH55T, SSH75 tube fired gas fryers with
Solstice Supreme Burner Technology which provides very
dependable atmospheric heat transfer and fuel saving
Energy Star
power blowers. This patented atmospheric burner system
with its long lasting alloy heat baffles reaches up to 70%
thermal efficiency and delivers lower flue temperatures. New
Self Clean Burner
second cleaning cycle to keep your burners tuned to operate
in the most energy efficient manner. Ventilation troubles are
virtually eliminated with the Down Draft Protection
pending)
maintenance, highly reliable fryer.
**
TM
performance without the need for complex
(patent pending) goes through a daily 30
(patent
that safely monitors your fryer, making this a low
MODELS AVAILABLE
SSH55 (40-50 lbs, 80KBtu/hr, 14” x 14” fry area)
SSH55T (20-25 lbs, 40KBtu/hr, 7” x 14” fry area
per side for this split vat fryer)
SSH75 (75 lbs, 105KBtu/hr, 18” x 18” fry area)
OPTIONS & ACCESSORIES (AT ADDITIONAL COST)
Digital Controller
I-12 Computer
Backup thermostat (only on Digital and I-12 computer)
Basket Lift (must be ordered with Digital Control or Computer)
(To meet AGA/CGA/CSA specification, must be ordered with
casters & installed with flexible gas hose w/restraining cable
Stainless Steel back (not available with basket lift)
9”(22.9 cm) adjustable,non-lock rear & front lock casters
Flexible gas hose with disconnect and restraining cable
Tank cover
Triple Baskets
Institutional Prison security package
BNB Dump Station
Filter System, see Supreme Filter spec sheet for details
TYPICAL APPLICATIONS
High Volume restaurants or multi-store restaurant chains
that require a Reliable, Highly Efficient EnergyStarTM**
rating, High Production Fryer with low operational energy
cost and lower annual maintenance and repair cost
Patent Pending
)
Model SSH55, SSH55T and SSH75 Solstice Supreme Gas Fryer
Pitco Frialator, Inc • P.O. Box 501, Concord, NH 03302-0501 • 509 Route 3A, Bow, NH 03304
603-225-6684 • FAX: 603-225-8497 • www.pitco.com
L10-266 Rev 1 02/07 Printed in the USA
Model SSH55, SSH55T and SSH75 Solstice Supreme Gas Fryer
3/4 INCH GAS CONNECTION
(CE 3/4 INCH BSP ADAPTOR
G
ADDS 1 1/2 [3.8] TO
CONNECTION)
6 FOOT (183 CM) POWER
CORD (NEMA 5-15 PLUG
P
115VAC UNITS ONLY)
A
38 11/32 [97.4]
34 15/32 [87.5]
P
SSH55/55T
48 11/32 [122.8]
A
15 5/8 [39.7]
B
4 1/4 [10.8]
C
SSH75
52 11/32 [132.9]
19 5/8 [49.8]
6 1/4 [15.9]
B
IN [CM]
OPTIONAL
COMPUTER
SOLID STATE
THERMOSTAT
INTEGRAL FLUE DEFLECTOR
OPTIONAL BASKET LIFT
11/16
[1.7]
54 13/32
[138.2]
NOM.
P
46 1/8
[117.1]
NOM.
10 1/2
[26.7]
NOM.
1 13/32 [3.6]
4 13/32 [11.2]21 7/8 [55.6]
Gas Input Rate / Hr
80,000 BTUs (23 kW) (84 MJ)
105,000 BTUs (31 kW) (110 MJ)
G
C
Model SSH55, SSH55T and SSH75 Solstice Supreme Gas Fryer
Model
SSH55
SSH55T
SSH75
per side
Frying Area
14 x 14 in (35.6 x35.6cm)
7 x 14 in (35.6 x35.6cm)
18 x 18 in (45.7 x 45.7 cm) 3-1/4 - 5 in (8.3 -12.7cm)
34 [86.4]
NOM.
12 13/16
[32.5]
NOM.
G
9 [22.9]
NOM.
INDIVIDUAL FRYER SPECIFICATIONS
Cook Depth Oil Capacity
3-1/4 - 5 in (8.3 -12.7cm)
3-1/4 - 5 in
8.3 -12.7cm
40 - 50 Lbs (18 - 23 kg)
20 - 25 Lbs (9 -11 kg) 40,000 BTUs (18 kW) (42 MJ)
75 Lbs (34 kg)
FRYER SHIPPING INFORMATION (Approximate)
Model Shipping Weight
SSH55
SSH55T
208 Lbs (95 kg) 258 Lbs (117 kg) 58 x 22 x 44 in (147.3 x 55.8 x 111.7 cm)
230 Lbs (104 kg)
SSH75 226 Lbs (103 kg)
Shipping Weight w B/L
280 Lbs (127 kg)
276 Lbs (125 kg)
Shipping Crate Size H x W x L
58 x 22 x 44 in (147.3 x 55.8 x 111.7 cm)
58 x 22 x 44 in (147.3 x 55.8 x 111.7 cm)
Shipping Cube
32.5 ft
32.5 ft
32.5 ft
INSTALLATION INFORMATION
ELECTRIC SYSTEM REQUIREMENTS (50/60 hz)
Amps
Fryer
# of Cord
10.7
208 / 220-240V 115V
Gas Type
Natural
Propane
* Check plumbin
GAS SYSTEM REQUIREMENTS
Store Supply Pressure *
7 - 10" w.c.(17.4 mbars/ 1.7 kPa)
11 - 13" w.c.(27.4 mbars/ 2.7 kPa)
Burner Manifold Pressure
4" w.c. (10 mbars / 1 kPa)
10" w.c. (25mbars/2.4 kPa)
/ gas codes for proper gas supply line sizing to sustain burner pressure when all gas appliances are full on.
CLEARANCES (Do Not Curb Mount)
30"
(76.2 cm)
6"
(15.25 cm)
Combustible material Non-Combustible material
Sides min. Rear min.
6" (15.2cm) 6" (15.2cm)
Sides min.
0"
Rear min.
0"
Do not block / restrict flue gases from flowing into hood
or install vent hood drains over the flue.
Fryer Flue AreaFront min. Floor min.
SHORT FORM SPECIFICATION
Provide Pitco Model (SSH55,55T,75) tube fired high efficiency gas floor fryer with EnergyStar TM**rating. Fryer shall be xx-xx lbs oil capacity, xxx Kbtu/hr,
xx” by xx” fry area, 304 SS peened tank, stainless front, door, sides. Blower Free atmospheric burner system with up to 70% thermal efficiency, self cleaning
burners, down draft protection, matchless ignition, drain valve interlock, behind the door solid state t-stat with melt and boil mode, separate gas shut off, 3/4" npt
rear gas connect, recessed cabinet back, 1-1/4" Full port drain, 3/16" bottom hinge, 9” adjustable legs, manual reset high limit. If supplied with casters: Casters
with 1" min. adjustment and front toe locks. Provide options and accessories as follows:
3
. (0.9m3 )
3
. (0.9m3 )
3
. (0.9m3 )
0.4
Pitco Frialator, Inc • P.O. Box 501, Concord, NH 03302-0501 • 509 Route 3A, Bow, NH 03304
603-225-6684 • FAX: 603-225-8497 • www.pitco.com
We reserve the right to change specifications without notice and without incurring any obligation for equipment previously or subsequently sold.
L10-266 Rev 1 02/07 Printed in the USA