Pitco Frialator Solid State Temperature Control User Manual

IMPORTANT INFORMATION FOR FUTURE REFERENCE
and retain this manual for the life of the equipment:
Model #: __________________________
Serial #: __________________________
Date Purchased: ___________________
Operations Manual
Covering Pitco # B2005301 SSTC Primary Control for GAS appliances B2005302 SSTC Backup Control for GAS appliances
B2005303 SSTC Primary Control for Electric appliances B2005304 SSTC Backup Control for Electric appliances
B2005305 SSTC Backup Control for SE147 Electric appliances
B2005401 SSTC Primary Control for Flat Bottom GAS appliances
Solid State Temperature Control
English
PRIMARY BACKUP FLAT BOTTOM
This control was developed by Pitco to replace bulb and capillary thermostats in fryer applications. It utilizes the latest in microprocessor technology and allows a host of features not practical with a simple capillary t-stat. Features include a selectable start up melt cycle, drain valve interlock, faulty probe detection, and a boil out mode.
This manual details the operation and adjustment of the Solid State Temperature Control.
L20-314 Rev 0 (9/7/07)
Solid State Temperature Control (SSTC)
1 Switch and Indicator Locations and Function:
On / Off switch:
Turns the control on or off. The power indicator
will be illuminated when the switch is in the on position.
Primary / Backup select switch:
In appliances with primary AND a backup control, this switch selects the control that will manage temperature in the appliance. When the switch is in the single dot position, power is diverted to the primary control, typically an I12 cooking computer. When the switch is moved to the two dot position, power is diverted to the Backup control.
Melt / No Melt select switch:
In the melt cycle position, melt cycle will be executed when the appliance first starts up. This melt cycle will end automatically when the temperature conditions are correct to allow full heat. Operators may bypass a running melt cycle by moving the switch to the full heat position.
PRIMARY
BACKUP
Temperature Set Knob:
The position of the pointer sets the cooking temperature of the control. Scales are shown in Fahrenheit and Celsius scales.
Power Indicator:
This green indicator shows the control is turned on.
Heat Demand Indicator:
This LED indicator shows when the control is demanding heat.
Heat Feed Back/Fault Indicator:
This indicator shows when the appliance is heating in response to a heat demand. Under normal conditions, this light will follow the head demand indicator. This indicator is also used to flash conditions for probe faults, drain valve open conditions, or, boil out operations.