Pinnacle Technology PS1XA, PS1XB, PS1X series, PS1XD, PS1XD-Pole Technical Manual

...
PS1X Price Computing Scale
Technical Manual
Pinnacle Technology Corp.
CONTENTS
1 PS1X EXPLODED VIEWS .............................................................................................................................. 1
1.1 PS1XA .................................................................................................................................................. 1
1.2 PS1XB................................................................................................................................................... 2
1.3 PS1XC................................................................................................................................................... 3
1.4 PS1XD .................................................................................................................................................. 4
1.1 PS1XD-Pole .......................................................................................................................................... 5
2 ERROR CODE WARNING .............................................................................................................................. 6
3 SEALING OPERATION METHOD and ACCELERATION of GRAVITY ADJUSTMENT .......................... 6
3.1 Destroy the sealing ................................................................................................................................ 6
3.2 The methods of gravity acceleration compensation value adjustment .................................................. 8
3.3 The methods of label sealing after amending ........................................................................................ 8
4 ZERO/FULL WEIGHT LEARNING METHODS ............................................................................................ 9
1
1 PS1X EXPLODED VIEWS
1.1 PS1XA
Stainless steel platter
2
1.2 PS1XB
Stainless steel platter
3
1.3 PS1XC
Stainless steel platter
4
1.4 PS1XD
Stainless steel platter
5
1.1 PS1XD-Pole
Stainless platter
6
2 ERROR CODE WARNING
ERROR HLb’ : when the battery voltage is in warning voltage (3.1 Vand screen displays HLb
words , which means current electricity is about to ran out and can last a very short time .
ERROR LLb: when the battery voltage is in power off voltage (2.9V, scale will power off
itself automatically when screen displays LLb words.
When the scale is in power on status and screen displays LLb words accompanied by tick sound and then power off automatically. which means scale is out of work already and is needed to change battery immediately.
3 SEALING OPERATION METHOD and ACCELERATION of
GRAVITY ADJUSTMENT
Gravity acceleration compensation value cant be adjusted directly after the PS1X price computing scale adopts sealing protection. If needs to adjust the gravity acceleration, you must destroy the sealing.
Our company adopts environmental label sealing, only needs to destroy the fragile label
sealing to startup the amending mode, do not need to disassemble the cover.
The operating steps of adjusting the acceleration of gravity A/D value and Zero full weight
learning are as follows:
3.1 Destroy the sealing
1) Destroy the fragile label sealing
2) Open the plastic sealing cover.
3) Only use the sharp-pointed instrument such as pen point to touch the adjustable switch lightly
can adjust the acceleration of gravity A/D value and zero full weight learning.
4) What you need to do is breaking the label based on the adjustment and do not need to open case.
The label sealing must be broke if you want to open the case. Please take the below pictures as you references.
7
Fragile label
Screw
Adjustable switch
Sealing cover
Nut
Fragile label
Screw
Adjustable switch
Sealing cover
8
3.2 The methods of gravity acceleration compensation value adjustment
Please follow below steps to amend the gravity acceleration compensation value and there are two methods to reach value adjustment.
Manual adjustment:
1) Press the key to start up the scale
2) Take off the platter
3) Destroy the label sealing, startup the switch
4) Put the platter on the scale again
5) Press key first to make sure the scale weight is zero, the screen will display 00.000kg, and
then put full weight on platter according to measuring range, eg :30Kg weight. If the weight
displayed on the screen is not correct, please press or key to adjust till the digit is right.
Automatic adjustment:
1) Press the key to start up the scale
2) Take off the platter
3) Destroy the label sealing, startup the switch
4) Put the platter on the scale again
5) Please make sure there is nothing on the platter, and the screen will display 00.000kg. then
please put full weight on the platter, if the weight displayed on the screen is not full weight,
please press the key to auto-adjust. At this time you will hear a long sound beep and the screen will display full weight.
3.3 The methods of label sealing after amending
The price computing scale needs to be sealed again after amending the gravity acceleration compensation value; the specific steps are as follows:
1) Close the plastic cover.
2) Paste a new fragile label sealing.
9
4 ZERO/FULL WEIGHT LEARNING METHODS
1 Press the power key to start up the scale, until in weighing mode. 2 Input number [1377]. 3 Destroy the sealing (chapter 3.1) and press the green adjustable switch. 4 Please make sure the platter is in horizontal and there is no object on platter. 5 Input number [2400128], press [CHG] key to confirm. It will set the range as 15kg.
Input number [2400192], press [CHG] key to confirm. It will set the range as 30kg.
6 Press the key [M1] continuously for two times, at this time you can hear a long sound
beep which means the zero weight learning is successful. The weight column will display 0.000.
7 Put the full weight on the platter. 8 Press the key [M2] continuously for two times, at this time you can hear a long sound
beep which means full weight learning is successful. The weight column will display the full weight 15.000 or 30.000 (depends on the setting on step 5 above).
9 Put any weight on the platter to check whether the zero/full learning is successful or
not.
10 Restart the machine to exit factory mode