CONTENT
1 SUMMARIZATION .......................................................................................................................................... 1
2 SPECIFICATION .............................................................................................................................................. 2
3 APPEARANCE ................................................................................................................................................. 4
4 INSTALLATION ............................................................................................................................................... 6
4.1 Install display pole ............................................................................................................................. 6
4.2 Power on/off ...................................................................................................................................... 7
4.3 Paper Installation ............................................................................................................................... 8
4.3.1 Label Paper Installation .......................................................................................................... 8
4.3.2 Receipt Paper Installation ......................................................................................................11
4.3.3 Linerless Paper Installation .................................................................................................. 13
5 PRINTER REPLACEMENT ........................................................................................................................... 14
6 SALES OPERATION ...................................................................................................................................... 17
6.1 Weight Unit Selection ...................................................................................................................... 17
6.2 Calculate by Weight ......................................................................................................................... 17
6.3 Tare Operation ................................................................................................................................. 18
6.4 Calculate by Piece ............................................................................................................................ 19
6.5 Discount ........................................................................................................................................... 21
6.6 Change Price .................................................................................................................................... 21
6.6.1 Permanently Change Price.................................................................................................... 21
6.6.2 Temporarily Change Price .................................................................................................... 22
7 SOME SIMPLE OPERATION ........................................................................................................................ 24
7.1 Copy price label ............................................................................................................................... 24
7.2 Print receipt ...................................................................................................................................... 24
7.3 Normal Package ............................................................................................................................... 24
7.4 Package by Fixed weight ................................................................................................................. 24
7.5 Package by Fixed Price .................................................................................................................... 25
7.6 Piece Together Usage ....................................................................................................................... 25
8 FUNCTION SET ............................................................................................................................................. 27
8.1 PLU Set ............................................................................................................................................ 27
8.2 System Set ....................................................................................................................................... 28
8.3 Function Lock .................................................................................................................................. 29
8.4 Lock Scale ....................................................................................................................................... 29
9 COMMUNICATION SETUP .......................................................................................................................... 30
9.1 Handshaking Flowchart of Label Scale and Background ................................................................ 31
9.2 Making procedure of connector ....................................................................................................... 33
10 TROUBLESHOOTING .......................................................................................................................... 34
11 APPENDIX ............................................................................................................................................. 37
11.1 Appendix 1: Barcode Coding List ................................................................................................... 37
11.2 Appendix2: Main difference between LB scale and LP scale: ........................................................ 39
11.3 Main difference between label scale and receipt scale .................................................................... 39
STATEMENT
Please refer to PC software management manual in attached CD about the PLU editing, hotkey downloading, label editing and parameter setting etc.
1
1 SUMMARIZATION
Simple and easy to operate
1. You can use single key to sell PLU quickly. Clerk can operate this scale without training.
2. This scale has 112 direct keys (224 hotkeys can be set) and can set hotkeys for most of the common goods.
Advanced function and endurance
1. Firmware program can be updated through PC in order to keep advanced and up to date.
2. FlashRom protection function assures the security of program and source.
3. Keyboard can be cleaned. It resists dirty with great validity.
4. Printer is designed elaborately and not easily subject to paper jam.
5. Barcode rotation can prolong the life of printer head. Printer core can be adjusted according to label paper.
6. Printer can load 1000 pieces of label paper while other printer can only load 800 pieces of label paper.
7. There are several package methods (fixed weight, and fixed price). Barcode printer is specially designed.
8. Piece together function, which can gather several kinds of commodity as required, such as fruit basket.
9. 12000 pieces of PLU can meet all kinds of demand.
10. Every piece of PLU can be set to use multiple labels.
11. Every piece of PLU can use single barcode format, which resolves the coding problems during selling.
12. Every piece of PLU can use single metric unit.
13. Numeric unit can be defined by user such as block, package and entries.
14. Sufficient PLU message includes barcode format, live commodity Code and package type and so on.
15. Label can be printed in rotated position.
16. Support 8 code, Ean-13 code, and 18 code and resolve the coding problem of live commodity.
17. Special barcode type for the convenience of live commodity lot management.
Convenient, flexible and powerful software support
1. What you see in label designing is what you get. Label size can be selected. Volume of smallest area can be created
according to user. Thus we can decrease cost greatly.
2. International design and supporting worldwide language make it unnecessary to add any accessory.
3. We can adjust the popular commodity at any time and improve the foregrounding working efficiency greatly.
4. Downloading data can be executed in scheduled time.
5. Background discounts fixedly.
6. Discount in different period of time. Ten discount modes can be defined and each mode has five periods of time using
different discount rate.
7. It supports broadcast downloading.
8. With the function of FTP and TCP/IP. The software supports Unix system and Internet.
9. We can set POS program parameters on PC.
10. Its management is separated into machine, commodity, and hotkey, which make usage of the scale optimum.
11. We can edit and print keyboard sheet quickly with this software.
12. Locking the POS function key can control its operation such as locking discount key and PLU edit key. Also it offers
function to unlock password.
13. It is managed by multi-user and records login information automatically in order to supervision.
14. It offers dynamic link library for the convenience of user‟s second development.
2
2 SPECIFICATION
Resolve segment Power: AC 100V~240V 50/60Hz 1A Working temperature: 0-40
Precision grade: A/D resolving rate: 30000 Verification scale interval: LS2615: 0kg~6kg e=2g 6kg~15kg e=5g
LS215: 0kg~15kg e=5g
LS21530: 0kg~15kg e=5g 15kg~30kg e=10g Number of verification scale interval: 3000
Printer: Printer driver: 24V Number of dots/line: 448dots/per line Dot spacing: 0.125mm
LCD: Message/weight: 24×110 dots Price: 8×110 dots Total price: 7×110 dots Dimension:
(1 4.3
364.0mm
344.9mm
263.4mm
124.0mm
(13.6
(10.4
(4.9
(6.2
429.1mm
478.3mm
158.2mm
(16.9
(18.8
[LS2R]
3
[LS2C]
[LS2N]
4
3 APPEARANCE
LS2R:
Printer
Display Tray
Hotkey
Numerical key
Function key Power switch
LS2C:
Printer
Display
Tray
Hotkey Numerical key
Function key
Power switch
5
Note: As for cleaning the thermal printer head, please refer to Chapter 10.
Gradienter Clearing pen
Note: If the printer head is dirty, clean hot sensor head softly with the cleaning pen attached. The cleaning pen is an alcohol pen; please cover it immediately after you wipe the dirty off.
LS2N:
Printer
Operator Display
Tray
Hotkey
Numerical key
Function key
Power switch
6
4 INSTALLATION
4.1 Install display pole
1. Take out the fix set
4. Put on fix set .Connect the line, and fix the 4 screws.
2. Open the LCD cover 3o ~5 o, and Mount the display pole.
3. Cover the LCD, then put on fix set like the picture shows.
7
4.2 Power on/off
At the first ten seconds after you turn on the scale, the LCD displays from “9” to “0” to enter self-testing.
Please wait and do not press any key, system initialization is going on.
“On/Off” key is used to turn on or turn off the scale softly. Press this key and hold it for 2 seconds to turn off
the scale, and so as how to turn down it. (Note: this key takes effect by the condition that the plug has connected and the power switch under the scale is turned on.)
We suggest that you should use On/Off key to turn On/Off the scale, and do not pull out the power plug directly if it hasnt been softly turned down, especially if the scale is under the conditions of connecting with network or downloading data.
Gradienter, which is under the tray
Circumvolve the 4 feet to adjust the level of scale, and make the air bladder into the red circle.
8
4.3 Paper Installation
4.3.1 Label Paper Installation Notice: please take the conveying protection bolt down, when you load the paper for the first time.
(1) Open the side cover
(2) Take out the printer, and open the turnable printing assembly
Conveying protection bolt
(3) Rip off the first several labels.
(4) Insert the release paper to the rewinder
(5) Roll the release paper in the rewinder axis, and adjust the paper-fixing-block to fix the roll paper.
paper-fixing-block
9
1. Turn the bar out wards, open the turnable printing assembly in the direction shown as the
arrowhead 1
2. Please rip off the first several labels, load paper in the direction shown as the arrowhead 2, roll the
release paper in the rewinder axis as the direction of arrowhead 3 shows.
3. Push the turnable printing assembly to the right position in the direction shown as the arrowhead
4
.
4. When every five-paper roll is used up, or the labels print unclearly, please clean the printing head by
using cotton dipping cleaning oil or alcohol.
1
2
3
4
(7) Close the side cover
(6) Close the turnable printing assembly.
10
Note: if the papers position is inaccurate after pressing the FEED key for the first time, pleas press this key again to relocate the paper‟s position.
Label Paper
We have two types of label paper: no-gap paper and gap paper
The label paper we produced is very suitable for label scale. It is a kind of environment protecting material has suitable thickness, high sensitivity and low price. We can produce any kind of specification label paper to match your request. Order easily, dial 86-592-5710087 or log on our company website www.aclas.com
Press this key for 2 seconds; the scale will adjust the papers position automatically; you yourself can also press it to adjust the paper minitrimly.
No-gap paper
Gap paper2mm
11
4.3.2 Receipt Paper Installation
1. Install the receipt paper-cutter.
2. Open the turnable printing assembly.
3. Load the paper like the map shows (directly lead the thermal paper to the paper outlet).
4. Pay attention to adjust the paper-fixing-block until the paper roll is fixed.
12
5. Close the turnable printing assembly.
6. Close the side cover.
NOTE: If you use thermal paper instead of label, you should choose „RECEIPT‟ in System Set. Please refer to Chapter 7.2 „Print receipt‟.
Paper-fixing-block
13
4.3.3 Linerless Paper Installation Note: The linerless paper printing module is different from the receipt and label printing module. If
customers bought was the receipt or label printing module, but now want to replace it to the linerless paper module, please contact the service department. Please pre-set the related items when you print linerless paper.
1) Press System set for seconds to enter the related setting, and then press key “ ” “ till the LCD display Gap paper and choose Yes, and then press the key Print/Enter to confirm.
2) Press System set for seconds to enter the related setting, and then press key ” “ till the LCD display paper type”, please choose “black label”, and then press the key Print/Enter to confirm.
1. Open the side cover and rotatable printing assembly.
2. Load the paper like the map shows (directly lead the thermal paper to the paper outlet).
14
5 PRINTER REPLACEMENT
If the printer is damaged, you can follow the steps below to replace a new one.
Precaution:
Before you do the following operations, please cut the power supply first. Do not disassemble, assemble or adjust the printer if it is operating satisfactorily. In particular, do not
carelessly loosen the screws holding various parts in place.
When servicing, be sure not to leave used parts or screws, etc.
1. Demount the damaged printer
Open the printer cover.
Pull out the printer
3 Close the rotatable printing assembly
4 Close the side cover
15
Use a screwdriver to push the latch to the left side.
Lift up the printer
16
2. Install a new one
Install new printer by following the demount procedure in reverse order.
Pull out the cable
17
6 SALES OPERATION
6.1 Weight Unit Selection
Operation step for price unit selection
OPERATION STEP
KEY
DISPLAY
REMARK
Weight
Unit
price
Total
1 Press UNIT key without releasing, or release the key after two seconds. Repress the key when hear a sound.
Unit
0.000kg
0.00
0.00
After step, the unit will be display circularly.
2 Select unit. For example, select PCS (g) as the unit.
0g
0.00
0.00
6.2 Calculate by Weight
There are three kinds of operation. If PLU data is downloaded by background server PC or pre-edited in the
scale, operation follows method 1 or method 2. Otherwise the operation follows method 3.
Notes:
1. AUTO state: On the condition that the weight and the unit are nonzero and after the weight is steady, a
label will be printed. When power on, “AUTO” signal is lighted, which means the scale is in “AUTO” state.
Press “AUTO” key to switch off the state. Suggest making “AUTO” state as default state.
2. ZERO state: There is nothing on the pan. Press “ZERO” key to let the weight zero and the “ZERO” signal
will be on.
3. Usage of Print key: All of the following operations including Calculate by Weight, Tare Operation, and
Calculate by Piece, Discount, and Change Price are in the “Auto” state. If the default state is not “Auto” state, the Auto arrow on the LCD won‟t be lightening, you must press Print key in order to print the label.
METHOD 1: HOTKEY OPERATION
Trade example: Some onions weighing 2.000kg are sold . Its hotkey is 01, and price is 0.500$/kg.
OPERATION STEP
KEY
ARROW
DISPLAY
REMARK
Zero
Auto
Weight
Unit
price
Total
1. Press “ZERO” key to let the scale return to zero
Zero
0.000kg
0.00
0.00
Ignore this step if the scale is in “ZERO” status.
2. Put the onions 2.000kg on the pan.
2.000kg
0.00
0.00
3. Input the hotkey 01 of the onions through PLU keyboard
0 1
2.000kg
0.50
1.00
*4. Cancel “AUTO” state
Auto
2.000kg
0.50
1.00
This step is optional. If you want to switch off the “Auto” state, do this step.
*5. Set “AUTO” state
Auto
2.000kg
0.50
1.00
Only after you take the above step 4 and want to
set “Auto” state, take this
step.
18
NOTES:
1) There are 224 hotkey. These hotkeys can be changed randomly and be printed in a sheet quickly by
the background PC.
2) The above opreation is for the hotkeys from 1 to112. As to hotkeys from 113 to 224, the above
operation step 3 should be changed as follows: Press “PLU” key and press the hotkey no. of the
commodity. Other steps are the same. METHOD 2: General operation step Trade example: Some onions weighing 2.000kg are sold. Their LFCODE is 10, unit price is 1.500$/kg.
OPERATION STEP
KEY ARROW
DISPLAY
REMARK
Zero
Auto
Weight
Unit
price
Total
1. Press “ZERO” key to make the scale return to zero.
ZERO
0.000kg
0.00
0.00
Ignore this step if the
scale is in “ZERO”
status.
2. Put the onions weighing
2.000kg on the pan.
2.000kg
0.00
0.00
3. Press “PLU” key
PLU
LLFCODE?
(1-6)
4. Input LFCODE 10 of the onions through small keyboard.
1 0
LLFCODE?
(1-6)
10.00
5. Press PLU key.
PLU
2.000kg
1.50
3.00
Ignore this step if the LFCODE has 6 digits.
METHOD 3: operation for PLU without settings.
OPERATION SETP
KEY
ARROW
DISPLAY
REMARK
Zero
Auto
Weight
Unit
price
Total
1. Press “ZERO” key to make the scale return to zero state.
Zero
0.000kg
0.00
0.00
Ignore this step if the scale is in “ZERO” status.
2. Press “UNIT” key without releasing to select a correct price unit such as kg.
Unit
0.000kg
0.00
0.00
3. Input unit price 2.00 through the small keyboard.
2 0 0
0.000kg
2.00
0.00
4. Put on the commodity weighing
1.0kg.
1.000kg
2.00
2.00
6.3 Tare Operation
It is only applicable to the commodity packed in package or container such as eggs, beans or fruit and so on.
MOTHOD: Operation for commodity separated from container or package. Trade example: A package of apples is sold. The hotkey of apples is 05, the net weight is 2.000kg and unit price
is 6.000$/kg.
19
OPERATION
KEY
ARROW
DISPLAY
REMARK
Zero
Auto
Tare
Weight
Unit
price
Total
1. Put the container or package weighing
1.000 kg on the pan.
1.000kg
0.00
0.00
2. Press “TARE” key.
Tare
0.000kg
0.00
0.00
The “TARE” signal flashing
means the scale is in the weight-deducting state.
3. Put a page of apples weighing
2.000kg on the pan.
2.000kg
0.00
0.00
4. Key in the hotkey 05 of apple through PLU keyboard.
05
2.000kg
6.00
12.00
5. Take away the container and the apples on the tray, then press “TARE‟ key.
Tare
0.000kg
0.00
0.00
This step is to leave the weight-deducting state. The arrow of “tare” disappears.
6.4 Calculate by Piece
There are three kinds of operation methods. The following operation of method 1 and method 2 is suitable for
PLU already downloaded by background sever or pre-edited on the scale. And method 3 is for PLU not pre-edited.
Note: Before you taking these two operations, please make sure the PLU is pre-edited with piece calculation. METHOD 1: Hotkey operation step Trade example: Ten pieces of cake are sold. The hotkey of cake is 05.
OPERATION
KEY
ARROW
DISPLAY
REMARK
Zero
Auto
Weight
Unit
price
Total
1. Input the number of the commodity through small keyboard. For example 10.
1 0
0.000kg
0.10
0.00
2. Press “UNIT” key.
Unit
0.000kg
0.00
0.00
The LCD returns to
initial state after “unit”
key is pressed.
3. Press the corresponding hotkey 05 of the cake through PLU keyboard.
05
0.000kg
3.00
30.00
20
METHOD 2: general operation step Trade example: Ten pieces of cakes are sold and the LFCODE of the cake is 12.
OPERATION
KEY
ARROW
DISPLAY
REMARK
Zero
Auto
Weight
Unit
price
Total
1. Input the number of the cake 10 through small keyboard.
1 0
0.000kg
0.10
0.10
2. Long press “UNIT” key and select a unit such as PCS (Kg).
Unit
KG
0.000kg
0.00
0.00
3. Press “PLU” key.
PLU
LLFCOD?
(1-6)
4. Input LFCODE of the cake 12 through small keyboard.
1
2
LLFCODE?
(1-6)
12
5. Press “PLU” key
PLU
0.000Kg
3.00
30.00
Ignore this step if the LFCODE has 6 digits.
METHOD 3: operation for PLU without pre-edited.
OPREATION
KEY
ARROW
DISPLAY
REMARK
Zero
Auto
weight
Unit
price
Total
1.Press “Unit” key without
releasing to select the correct unit price such as PCS (Kg)
Unit
0.000Kg
0.00
0.00
2. Input the number of the commodity through numeric keyboard. For example 10.
1
0
0.000Kg
0.10
0.10
3. Press “unit” key.
Unit
0.000Kg
0.00
0.00
4. Input unit price through the numeric keyboard. For example 2.0.
2 0 0
0.000Kg
2.00
20.00
21
6.5 Discount
Discount function can be locked by password which is set and can be randomly changed by background sever PC.
METHOD: operation for proportional discount.
Trade example: some peaches give a discount of 95. Its unit is 8.0$/kg and hotkey is 12.
OPERATION
KEY
ARROW
DISPLAY
REMARK
Zero
Auto
weight
Unit
price
Total
1. Input discount proportion of the commodity 9 5 through numeric keyboard.
9
5
0.000kg
0.95
0.00
2. Press Discount key.
Discount
0.000kg
0.00
0.00
The LCD returns to initial state after DISCOUNT key is pressed.
3. Put the commodity weighing 1.000kg on the pan.
1.000kg
0.00
0.00
4. Key in the corresponding hotkey of the peaches e.g. 12.
12
1.000kg
8.00
7.60
Notes:
As for step 3 and 4, please refer to the operation of calculate by weight‟. You can choose other kinds of operation such as normal operation or operation for pre-edited PLU to proceed with the above operation.
6.6 Change Price
Change the unit price of a commodity. There are two methods to change the unit price of a commodity, they are
permanently change price and temporarily change price.
6.6.1 Permanently Change Price METHOD 1:
Trade example: The unit price of the apples 4.000$/kg. After changing price, its unit price is 3.000$/kg and the
hotkey is 05.
OPERATION
KEY
ARROW
DISPLAY
Zero
Auto
Weight
Unit
price
Total
1. Key the hotkey 05 of the apples via PLU keyboard.
05
0.000kg
4.00
4.00
2. Press Change price key.
Change Price
? PRICE?
0.00
4.00
3. Key in the new price 3.000$/kg.
3 0 0
? PRICE?
3.00
4.00
4. Press Enter key.
Enter
0.000kg
3.00
0.00
5. Proceed with the normal operation of weighing or granular price calculating.
METHOD 2: Trade example: Some apples are sold. The unit price of the apple is 4.000$/kg, and LFCODE is 900001. After
change the unit price, the unit price of the apple is 3.000$/kg.
22
OPERATION
KEY
ARROW
DISAPLY
Zero
Auto
Weight
Unit
price
Total
1. Press Change price key.
Change Price
LLFCODE?
(1-6)
2. Key in the LFCODE 900001 of the apples through small keyboard.
900001
? PRICE?
0.00
4. Key in the price changed 3.000.
3 0 0
? PRICE?
3.00
5. Press Enter key.
Enter
0.000kg
3.00
0.00
6. Proceed with the normal operation of calculate by weight or calculate by piece.
6.6.2 Temporarily Change Price
METHOD 1: temporarily change the price of cherryits original price is 24.0$/PCS(g))。 Trade ExampleSell 10 cases of the cherry, temporarily change the price as 30.0$/PCS(g), and its hotkey is 11.
When finish this dealing, it will recover to the original price 24.0$/PCS(g).
OPERATION
KEY
ARROW
DISAPLY
REMARK
Zero
Auto
Weight
Unit price
Total
1. Key in 10 (10 cases) via the numeric key.
1 0
0.000kg
0.10
0.00
2. Press Unit key.
Unit
0.000kg
0.00
0.00
Display is back to the initial status.
3. key in the new price
30$/PCS(g)
3 000
0.000kg
30.00
0.00
Begin with this step if sell the commodity by unit.
4.Press Comm. Test key
Comm. Test
0.000kg
0.00
0.00
5. Key the hotkey 11 of
the cherry via PLU keyboard.
1 1
0.000kg
30.00
300.00
METHOD 2: Trade Example The unit price of the cheese is 4.000$/ PCS (g), and LFCODE is 15. Change the unit price of
the cheese as 3.000$/kg. When finish this dealing, it will recover to the original price 4.000$/PCS (g).
OPERATION
KEY
ARROW
DISAPLY
REMARK
Zero
Auto
Weight
Unit price
Total
1. Key in the LFCODE
15 of the cheese via small keyboard.
1 5
0.000kg
15
0.00
2. Press Change price
key.
Change Price
? PRICE?
0.00
0.00
3. Key in the new price
3.0 $/PCS (g).
3 0 0
? PRICE?
3.00
0.00
4. Press Print key.
Print
0.000kg
3.00
3.00
23
METHOD 3: Temporarily change the PLU whose initial unit price is 0$/kg.
1. Trade Example 1Suppose the initial price of the cherry is 0$/kg, and now temporarily change it as 30.0$/kg,
and its hotkey is 11. When finish this dealing, it will recover to the initial price 0$/kg.
OPERATION
KEY
ARROW
DISAPLY
REMARK
Zero
Auto
Weight
Unit
price
Total
1. Put the cherry weighted 1kg onto the scale.
1.000kg
0.00
0.00
2. key in the new price 30$/kg
3 0 0 0
1.000kg
30.00
30.00
3. Key the hotkey 11 of the cherry via PLU keyboard.
1 1
1.000kg
30.00
30.00
PLU with its unit price as 0 cannot be sold directly.
2. Trade Example 1:The original unit price of PLU is 0$/kg, sell with LF-code.
Suppose the initial price of the cherry is 0$/kg, and now temporarily change it as 30.0$/kg, and its LF-code is 13.
When finish this dealing, it will recover to the initial price 0$/kg.
OPERATION
KEY
ARROW
DISAPLY
REMARK
Zero
Auto
Weight
Unit
price
Total
1. Put the cherry
weighted 1kg onto the scale.
1.000kg
0.00
0.00
2. Key in LF-code 13
via the numeric keypad.
1 3
1.000kg
0.13
0.00
PLU with unit price 0$/kg can‟t be sell directly.
3. Press key PLU
PLU
? PRICE?
0.00
30.00
4. key in the new
price 30$/kg
3 0 0 0
? PRICE?
30.00
30.00
5. Press Print key.
Print
1.000kg
30.00
30.00
Ignore this step if the LFCODE has 6 digits.
METHOD 4: Temporarily change the price of the PLU, which is needed to be weighted. Trade ExampleThe unit price of the cabbages is1$/kg, and it should be change price as 2$/PCS in the evening to
promote it. When finish this dealing, it will recover to its initial price 1$/kg. Suppose a cabbage is 3kg, and its hotkey is 13.
OPERATION
KEY
ARROW
DISAPLY
REMARK
Zero
Auto
Weight
Unit
price
Total
1. Put the cabbage
onto the scale.
3.000kg
0.00
0.00
Sell by PCS now.
2. Key in the new
price 2$/PCS.
200
3.000kg
2.00
6.00
3Press Comm. Test key
Comm. Test
3.000kg
0.00
0.00
4. Key the hotkey 13
of the cabbage via PLU keyboard.
1 3
3.000kg
2.00
2.00
24
7 SOME SIMPLE OPERATION
7.1 Copy price label
1. Call PLU or input unit price in normal state and print a piece of label.
2. Press “Copy” key and input a number between 1 and 9, then the corresponding number pieces of label is printed.
3. Press Copy key and 0 key to print 1000 pieces of label continuously.
7.2 Print receipt
1. Reloaded the rolling paper and extend its head out of the outlet. Make sure not roll the paper head in the
rewinder. Please refer to Chapter 4.3.2 Receipt Paper Installation.
2. Use key [] or [] to select the paper type as RECEIPT.
3. Press Enter key to confirm.
Note: If you want to use label paper again, you should enter this function to select the paper type as LABEL‟, and after setting you must restart the scale by press the on-off on the scale‟s bottom (switch to RECEIPT‟ no need restart the scale).
7.3 Normal Package
This is suitable to quickly pack a same commodity (or different commodity with the same unit price) with
different weight. (The Package Type is set as Normal‟ on the scale software PLU manager.
1. Start up the function of “Auto” and “Price lock” (these two indicator light are lighting)
2. Select PLU or input the unit price.
3. Put the commodity (to be packed) on the pan and the label will be printed automatically.
Note: the operation of the right is suggested if you want to operate quickly.
1. Put commodity 1 on the pan
2. After the label is printed automatically put commodity 2 on the pan at the same time, take away commodity 1.
3. Take away the label and stick it on commodity 1. The label of the commodity 2 will be printed out.
4. Put commodity 3 on the pan and take away commodity 2.
5. Take away the label and stick it on commodity 2, the next label will be printed.
6. Repeat as the above steps to overlap the time of waiting for printing label and sticking label.
7.4 Package by Fixed weight
Fix weight package, this function is available by setting on PC software first. Please refer to the related
chapter package by fixed weight on “LS2X scale PC software management in attached CD..
For example: pack fish by the fixed weight 0.255kg, and the corresponding hotkey is 38.
Note: Before operate on the scale, please press key Price Lock first, and the indicator light for price lock will be lighting.
25
OPERATION
KEY
ARROW
Display
Remark Zero
Auto
Fix
Weight
Weight
Unit
Price
Total
1. Put the fish on
the pan.
0.255kg
0.00
0.00
2. Press the hotkey
38 of the fish via PLU keyboard.
3 8
0.255kg
70.00
17.85
Attention: The commodity can be sold at the condition that its weight is between the weight tolerance +5%kg while it is in Fixed Weight package mode.
7.5 Package by Fixed Price
Fix price package, this function is available by setting on PC software first. (As for the PC software operation,
please refer to Chapter Package by Fixed Weight in attached CD. And choose the item Fixed Price in the column Package Type, input the fixed price in the column Unit Price, and input the weight value for the commodity‟s fixed price in the column „Package Weight‟
Note1. after download the setting data to the scale, the indicator light for Fixed Price‟ will be lighting;
2. before operate on the scale, please press key Price Lock first, and the indicator light for price lock will be lighting.
OPERATION
KEY
ARROW
DISPLAY
REMARK Zero
Auto
Fix Price
Weight
Unit
Price
Total
1. Put the fish on
the pan.
0.505kg
0.00
0.00
2. Press the hotkey
38 of the fish via PLU keyboard.
3 8
0.505kg
0.00
35.35
Attention: The commodity can be sold at the condition that its total price is between the package tolerance $+5% while it is in Fixed Price package mode.
7.6 Piece Together Usage
Piece together function is usually used in the aspect, such as pack gift-box and fruit-dish. This function is available by setting a hotkey piece together‟ on PC software first. As for the PC software
operation, please refer to Chapter Piece together usage in attached CD.
Note:1. After download the setting data to the scale, the indicator light for Fixed Weight‟ and Fixed Price will be lighting;
2. Before operate on the scale, please press key Price Lock first, and the indicator light for price lock will be lighting.
For examplePackage a fruit-dish (apple, grape, and orange)
PLU nameapple weight unitkg unit price10.00 $/kg hotkey 06 PLU nameorange weight unitkg unit price4.00 $/kg hotkey 07 PLU namegrape weight unitkg unit price20.00 $/kg hotkey 08
Suppose each of the three fruits is 1.000kg.
26
OPERATION
KEY
ARROW
DISPLAY
REMARK
Zero
Auto
Fix weight
Fix price
Weight
Unit
Price
Total
1. Press hotkey 01
0.000kg
0.00
0.00
2. Put the apple on
the pan, and press hotkey 06
0 6
1.000kg
0.00
0.00
3. Put the orange on
the pan, and press hotkey 07
0 7
2.000kg
0.00
0.00
4. Put the grape on
the pan, and press hotkey 08
0 8
3.000kg
0.00
0.00
5. Press hotkey 01
01
3.000kg
.34.00
34.00
27
8 FUNCTION SET
8.1 PLU Set
Notes: This operation can be locked by password that is set in background PC changed randomly.
PLU Input
1.Press PLU key for 2 seconds. The display shows “PLU EDIT, it means the system is in the state of editing PLU.
2. Key in LFCODE when the display prompt LLFCODE?, and press Enter to confirm. Then the display shows NAME” and enter editing items: N/L/C/P/U/F/T/B/D/W/Y/M/G/I/R/S, you can use key and to choose
the item you want to edit, then press Enter.
3. Press Enter key. Input the corresponding data by sequence. Refer to the following notes.
4. Press S or Enter to save the above operation.
NOTES: the following is the sequence of PLU data input. When one item is input, press Enter to confirm. The system will shift to another item, and press Enter again to enter it. If no contents are inputted, press ESC to exit.
1) N---PLU NAME: Input PLU name not exceeding 36 characters directly through keyboard. And through the
numeric keyboard input the code of the input characters. The code is in the word stock table.
2) L---LFCODE: Input Life and Fresh Code within 6 digits.
3) C---PLU CODE: Input PLU code within 10 digits.
4) P---UNIT PRICE: Input PLU price.
5) U---UNIT: Select price unit from g, 10g, 100g, kg, Lb and Oz or PCS (g), PCS (kg), PCS (Lb) and PCS (Oz).
6) F---SHELF: Input the shelf-time of PLU: period from 0 to 365---means its unit is day; period from 1000 to
9999---means its unit is hour‟. e.g. input 60, which stands for its shelf-time is 60-day; input 1006, which means its shelf-time is 6-hour.
7) T---TARE: Input tare (not exceeding the maximum weight).
8) B---BAR CODE: Select barcode type from 1 to 99.
9) D---DEPARTMENT: Input department code from o to 99.
10) W---PACKING WEIGHT: Input the package weight.
11) Y---Packing Type: Use key “”“”to select (Normal; fixed weight; fixed price; both) weight and price.
12) M---MESSAGE1: Input the selected message No. (0~12000). 0-no use this message
13) G---MESSAGE2: reserved
14) I---LABEL SELECT (Set label of corresponding PLU) Use key “”“”to select (DEF, D0, D1,D0D1).
15) R---Set PLU discount (-10~125).
16) S---Save PLU revision.
PLU Data Revise
1. Press PLU key for two seconds. The display shows “PLU EDIT, it means the system is in the state of editing PLU.
2. Key in LFCODE when the display prompt LLFCODE?, and press Enter to confirm. Then the display shows NAME” and enter editing items: N/L/C/P/U/F/T/B/D/W/Y/M/G/I/R/S, you can use key and to choose the item you want to edit, then press Enter.
3. Key in the corresponding letter of the item to be modified, refer to the above notes, for example, key in N to modify name and P to modify price.
4. Input the new information.
5. Press S key to save the above results. Else they are abandoned.
28
8.2 System Set
Note: This operation can be locked by password set in background PC server and is changeable as will.
1. Press the System Set for two seconds to enter the system setting state.
2. Use “” “” to select the desired items as follows: T/A/L//S/N/J/X/W/K/Y/D/E/F/Y/G/Q/N/W/;/@/V Refer to the following notes.
3. Press Enter key to confirm.
Notes:
1. T---DATE: input date and time, use key ” “to switch the two options. (Before you do it, you need to set
the date format)
2. A---ALIGN: Use arrow key to select one of the 17(-8~+8) values to adjust the label to the most suitable
printing state.
3. L---LABEL SELECT: Choose label type D0 or D1. (We only have such two label types presently.)
4. S---Paper: Using arrow to select paper type: label, receipt or no recycle.
5. N---DATE FORMAT: Set date format.
6. PRINT WEIGHT UNIT: This function is to set whether print the weight unit in the label.
7. PRINT PRICE UNIT: This function is to set whether print the price unit in the label.
8. J---PRICE FORMAT: Set decimal position for unit price in the label.
9. X---AMOUNT FORMAT: Set decimal position for total price in the label.
10. BARCODE SET: set barcode type; refer to Chapter 11.1 Appendix 1 for the barcode list details.
11. W---Print Time: This is to set whether print time in the label or not.
12. K---ROUND: set rounding; input a digit among 1 ~ 10, round off the last digit.
1: 0 off 1 up 2~4: Reserved 5: 4 off 5 up 6: 5 off 6 up 7: 6 off 7 up 8: 7 off 8 up 9: 8 off 9 up 10: All round off E.g.: if you input 5, then 2.45 will be rounded to 2.5, while 2.44 will be rounded to 2.4.
13. Y---YEAR FORMAT: Set year format, use key ” “”to select 2 digits or 4 digits.
14. D---DENSITY: Select printing density from “0” to “5” with arrow. This scale supports print density class 0 to
5. „0‟ is the lightest one of all, and „5‟ is the thickest of all.
15. Q---PRINT DELMARK: This function is to set whether print delete mark in the label or not.
16. G---SOURCE PRICE: This function is to set whether use the original price before discount as the sale price.
17. PRINT ITEM IN WEIGHT ITEM: Two items can be printed in the weight column: Weight and PCS. This
function is to set whether print Weight or PCS in the weight column.
18. E---MESSAGE 1: This is to set the message no. of MESSAGE 1. Input a number among 0~250. Each number
represents different message content.
19. F---MESSAGE 2: This is to set the message no. of MESSAGE 2. Input a number among 0~250. Each number
represents different message content.
20. Set BARCODE LINE WIDTH: only effective in 18-code barcode. Use arrow key to select width or narrow.
21. ;---ANTI WIND: Select anti-wind state.
22. @---IP: Input the scale IP address directly. Note: The scale IP and PC IP should be in the same network segment, namely, the first three fields of
scale IP should be accord with PC IP. E.g. my computers IP is 192.168.1.151, therefore, in the next step, I should set the first three fields of scale IP to match with PC IP, namely, the first three fields of scale IP should be 192.168.1.‟ and I set scale IP as 192.168.1.101.
23. V---SPEED: Set print speed. Select print speed from “0” to “7” with arrow. 0‟ is the fastest one of all, and „7‟
is the slowest of all.
24. Rebate to 23 department: Whether to set the initial 2-digit department numbers of the discount PLU barcode
as 23.
25. R---HOST IP: Input the host IP address directly, and press key [ENTER].
26. stat. mode: Whether to set the system in stat. mode. Use arrow key to select YES or NO.
29
If you choose YES, the system will be in stat. mode, when you use the hotkey, the sale subtotal of this key will be printed on label. And if you choose “NO”, you can do hotkey operation as normal.
27. stat Warnning? : Whether to set the stat. Warnning. Use arrow key to select YES or NO.
28. prn Tubtot: Press [Enter] to print the total label.
29. Prn ALL stat. plu: This operation can print stat. data of each hotkey.
30. clr stat.: Press [Enter] to clear stat..
31. Z---LABEL SELECT: This is to choose the label paper type. There are two types of label paper, one is
No-gap paper, and the other is gap paper. User key ” “ to select YES or NO. YES for No-gap paper, and NO for gap paper. Gap paper is the default label paper type. Only when you install the No-gap paper into the scale, you need to set this item to YES.
8.3 Function Lock
PLU edit, Discount Program and tare functions can be locked by password and password of each function is independent and changeable. Password is set by background PC server and downloaded to every scale. Operation on the label scale is as followings:
Note: Once you turn on the locked function, this function will be valid until the scale is warmly closed.
Turn on the
locked
function
1. Turn on the scale.
2. Select the desired function key. Press Discount key two seconds to enter discount function, the system prompts to input
password, then input the safe password which is set by background PC server.
Press PLU key for two second to enter PLU editing state, the system prompts to input
password, then input the safe password which is set by background PC server.
Press System Set key for one second to enter program setting state, the system prompts to
input password, then input the safe password which is set by background PC server.
Press Tare key for one second to enter tare state, the system prompts to input password, then
input the safe password which is set by background PC server.
Press Change Price key for one second to enter change price state, the system prompts to
input password, then input the safe password which is set by background PC server.
Lock these functions again.
1. Press On/Off key for two seconds to warmly close the scale.
2. Press On/Off key to open the scale.
8.4 Lock Scale
You can lock the scale by password, so that other people can‟t do any operation on the scale. Lock scale as the following method:
Lock the scale
1. Press Password key until the word PASSW appears on the LCD display.
2. Input the eight-digit password by numeric keyboard.
3. Press Password key and after hearing a beep sound to show the password has been set.
Turn on the lock casually
1. Turn on the scale.
2. The LCD display PASSW.
3. Input the eight-digit password, then press Password key to turn on the lock.
Turn on the lock timelessly
1. Turn on the scale.
2. Press C key.
3. Press Password key for two seconds until the word PASSW appears on the LCD display.
4. Input the eight-digit password, then press Password key to turn on the lock.
30
9 COMMUNICATION SETUP
Note: If the HUB/SWITHCH cant identify the Crossover Cable when you use HUB/SWITCH to connect the scale, please use A Straight through Cable to replace the Crossover one.
PC MANAGER
POS SERVER
POS1
POS2
NETWARE
WINDOWS NT
UNIX
Ethernet
TO PC
31
Link32 run starting
Command (201)
Background transfers one
PLU to Link32 (110)
LINK32 sends ACK
Command (202)
Background requires uploading sale account (120)
Link32 sends end
command (220)
Link32 transfers one account to background (210)
Background sends ACK command (102)
Link32 download PLU change date to label scale
9.1 Handshaking Flowchart of Label Scale and Background
Link32 gathers Sale account from the scale
Is there PLU N is there N Change in sale Background? account i
Y Y
32
Record package format: One record package includes three aspects:
1. Package length 4Byte
2. Command 4Byte
3. Record uncertain length Example: Starting command: 00080201
Package length: 0008 Command: 0201 Record: no
ACK command: 00220102100000010000
Package length: 022 Command: 0102 Source: 02100000010000 From command list we can see responding command includes three aspects: Command: 0210 which means responding to command 0210 LFCode: 000001 Error code: 0000 which means no error
Command list:
Link32->background
Code
Description
Type
Length
Remark
0201
Starting command
Number
4
0202
ACK command
Number
4
Command code
Number
4
LFCode
Number
6
Error code
Number
4
0210
Link32 sends sale records command
Number
4
Scale number
Number
8
User ID
Number
6
LFCode
Number
6
Unit price
Number
8
No decimal fraction mode
Weighing unit
Number
1
Hexadecimal system
Total price
Number
10
No decimal fraction mode
Weight
Number
6
Within 15kg after logic conversion
Sell time
Number
14
YYYYMMDDHH (24) NNSS
Discount
Number
1
0:common, 1:change unit price, 2:change total price
Last connect time
Number
14
YYYYMMDDHH (24) NNSS
0220
Sales records sending over
Number
4
33
9.2 Making procedure of connector
(1) Select a connector wire (8 pin) by length of L.
(2) Put A end of the connector wire at the edge of blade of pliers horizontally (note: point against the baffle to ensure 12mm peeling length), press the pliers and pull out the wire and the peeling length is about 12mm.
1.Connection order:
green/white, green, orange/white, blue, blue/white orange, brown/white, white.
2. line Connection order:
orange/white, orange, green/white, blue, blue/white,
green, brown/white, white.
(3) Plug peeling end (A) into 8 PIN PHONE connector as either Connection order above.
Make sure to plug to the end.
(4) Plug wire connector with 8 pin into the position with logo 8P of pliers gently, then press the pliers forcefully.
(5) When process end B of connecting wire, don‟t twist
wire and keep the wire with same color in the same position.
Protruding strip
Edge of peeling blade
Edge of cut blade
34
10 TROUBLESHOOTING
The scale breaks down:
1. There is no sound and no display but backlight when power is on.
Reason: Electric sparkle caused by power plugging in and pulling out destroys the ROM program in the main
board.
Treatment: Change main board, reset sequence number and download all records.
2. There is no sound and displaying „UPDATE‟ when power is on.
Reason: The same as the above. Treatment: Download POS program to the scale again.
3. Buzzer sounds continuously and the displaying characters bounce.
Reason: The same as the above. Treatment: The same as the above.
Question about print:
1. Paper location is normal but the printed out label is blank.
Reason: Label type sets error. It is required label type printed out by the scale should be consistent with which
downloaded from PC. Otherwise the label printed out will be blank.
Treatment: a. Adjust the scale according to the following sequence.
Enter system Enter label type Select label type function set selection as D0 by arrow
b. Also we can adjust the software with PC. Open Link 32, input serial number of the scale, run
command function set and download this function set to the scale.
2. Printer spits out half paper or one and a half papers and paper locates abnormally.
Reason: a. Paper type sensor set error b. Printer back photoelectric group is in wrong direction or covered by dust. c. Photoelectric board is bad.
d. Photoelectric group of back photoelectric is bad.
Treatment: a. According to the following sequence, adjust the scale.
Enter system Enter paper Select paper type as Set function sensor selection „Label‟ with arrow
We can also make software adjustment on computer. Open „Link32‟, set paper type as „Label‟ in function
set; download the set to the scale.
b. Check whether the back photoelectric group is gradient or covered by dust. c. If it can‟t be resolved yet it is necessary to exchange back photoelectric group, which had better be
handled by the professional of our company.
3. Label out of printer is obscure and not dark enough.
Reason: a. Printer header is not put well.
b. Hot sensor head is dirty.
c. It is necessary to carry on voltage learning. Treatment: a. Place printer header in suitable position b. Clean the thermal printer with the cleaning pen attached.
4. Label printed out is half clear and half blur even blank.
Reason: a. Printer header is not put well.
b. Hot sensor header is dirty.
c. Printer header is distorted. Treatment: a. Place printer header in suitable position. b. Clean the thermal printer with the cleaning pen attached. The cleaning pen is an alcohol pen; please
cover it immediately after you wipe the dirty off.Please refer to the demonstration below.
c. If this problem can‟t be resolved yet it is necessary to change the printer. The bad printer had better
to be handled by professional of our company.
System set
L
Enter
System set
S → Enter
35
Demonstration for cleaning the thermal printer head:
[Note]The alcohol cleaning pen is with the scale when it leave factory. Please take it out as the picture shows below.
5. There is strange letter on the label.
Reason: LFZK has not been downloaded. Treatment: Download LFZK again.
Questions about keyboard:
1. Display is normal but keyboard sounds continuously.
Reason: There is a short circuit in keyboard. Treatment: change keyboard circuit.
2. Key doesn‟t sound.
Reason: a. Key wire is not inserted well.
b. Electric rubber of key press circuit board is not installed well.
c. The replaced kit is bad. Treatment: a. Check key wire and insert it again. b. Remove the electric rubber of key press and another location with rubber strip install again. c. If the problem can‟t be resolved yet, the selected kit is bad.
Questions about weighing:
1. The scale can‟t weigh correctly.
Reason: a. Rubber pad, which sustains the scale pan, touched the shell (upper cover).
Open the thermal printer head
Clean the thermal printer head.
Clean the thermal printer head.
36
b. Humidity or component aging or area difference makes the scale weigh incorrectly.
c. Sensor is damaged by over loading. Treatment: a. Check whether the upper covers are buckled well. If they still knock each other, install sensor
sustainer again.
b. Study zero weight and full weight again. If it is still no use, change main board, OP board or even
the sensor.
c. Change sensor and sustainer.
Note: OP board and sensor should be returned to our company in principal if they can‟t be used.
2. Zero state is not stable.
Reason: a. It is affected by environment such as vibration, or magnetic field interference, or wind. b. Weighing circuit is affected with damp. Treatment: a. Remove interference. b. Change main board. c. If the problem can‟t be resolved. Return the whole scale to our company to repair.
3. The scale can‟t weigh.
Reason: Main board or OP board or sensor is bad. Treatment: a. Change main board. b. Check whether OP board is abnormal. Return the whole scale to our company.
Questions about communication:
1. The scale can‟t communicate.
Reason: a. Communication port set error.
b. Serial number of the scale has not been set.
c. Connecting head is not used correctly or Netware wire is obstructed.
d. There is some wrong with power board or main board. Treatment: a. Confirm the correct communication port. b. Confirm number set in Link32 is consistent with the number in the scale. c. Confirm the Netware wire is smooth and communication connecting header is used correctly. There
are two types of communication port RS-232 which uses 9-pin or 25-pin connecting port attached with the scale and RS-422 which uses RST-11A connecting head.
d. If the above are right, detect whether main board or power board is wrong and change the wrong
main board or power board.
2. Downloading is stopped at 1/N (n represents some number) and computer shows message
“communicate error!”
Reason: Main board is error, which may be caused by chip damage. Treatment: Change main board or chip (ROM).
Question about display:
Display can‟t show all characters or even a character.
Reason: a. Display pole has not been installed well, which causes the display and the machine in bad contact. b. Water flows into the base seat of display pole which makes link board short-circuit or rotten. c. Display is damaged. Treatment: a. Install display pole and fix the bolt. b. Change link board or display pole. c. Change display pole.
Other question:
Roll paper can‟t be driven by print.
Reason: maybe roll paper doesn‟t get well along with rotating axis. Or there is some matter with rotating axis. Reason: Maybe roll paper doesn‟t get well along with rotating axis. Or there is some matter with rotating axis.
Treatment: Install the printer again which had better be processed by our company.
37
11 APPENDIX
11.1 Appendix 1: Barcode Coding List
Barcode type
Department
Commodity
number
Total price
Weight
Checksum
00~09: Ean13 code, the front two codes represent department code:
00
DD (2)
IIIIIIIIII (10)
X X C
01
DD (2)
IIIIII (6)
PPPP (4)
X C 02
DD (2)
IIIII (5)
PPPPP (5)
X C 03
DD (2)
IIII (4)
PPPPPP (6)
X C 04
DD (2)
III (3)
PPPPPPP (7)
X C 05
DD (2)
IIIIII (6)
X
Q.QQQ (4)
C
06
DD (2)
IIIIII (6)
X
QQ.QQ (4)
C
07
DD (2)
IIIII (5)
X
QQ.QQQ (5)
C
08
DD (2)
IIIII (5)
X
QQQQ.Q (5)
C
09
DD (2)
IIIII (5)
X
QQQQQ (5)
C
10~19: Ean13code, the front two codes represent fixed code:
10
20(2)
IIIIIIIIII (10)
X X C
11
21(2)
IIIIII (6)
PPPP (4)
X C 12
22(2)
IIIII (5)
PPPPP (5)
X C 13
23(2)
IIII (4)
PPPPPP (6)
X C 14
24(2)
III (3)
PPPPPPP (7)
X C 15
25(2)
IIIIII (6)
X
Q.QQQ (4)
C
16
26(2)
IIIIII (6)
X
QQ.QQ (4)
C
17
27(2)
IIIII (5)
X
QQ.QQQ (5)
C
18
28(2)
IIIII (5)
X
QQQQ.Q (5)
C
19
29(2)
IIIII (5)
X
QQQQQ (5)
C
20: no print barcode
21~29: Ean13 code, the front one code represents department code:
21
D (1)
IIIIIII (7)
PPPP (4)
X C 22
D (1)
IIIIII (6)
PPPPP (5)
X C 23
D (1)
IIIII (5)
PPPPPP (6)
X C 24
D (1)
IIII (4)
PPPPPPP (7)
X C 25
D (1)
IIIIIII (7)
X
Q.QQQ (4)
C
26
D (1)
IIIIIII (7)
X
QQ.QQ (4)
C
27
D (1)
IIIIII (6)
X
QQ.QQQ (5)
C
28
D (1)
IIIIII (6)
X
QQQQ.Q (5)
C
29
D (1)
IIIIII (6)
X
QQQQQ (5)
C
30~35,40~45: 18code, the front one code represents department code
30&33
D (1)
IIIIII (6)
PPPPP (5)
QQ.QQQ (5)
C
31&34
D (1)
IIIIII (6)
PPPPP (5)
QQQQ.Q (5)
C
32&35
D (1)
IIIIII (6)
PPPPP (5)
QQQQQ (5)
C
50~52: 8 code
50
X
IIIIIII (7)
X X C
51
D (1)
IIIIII (6)
X X C
52
DD (2)
IIIII (5)
X X C
53
X
IIIIIIII(8)
X X X
54
D(1)
IIIIIII(7) X X
X
55
DD(2)
IIIIII(6) X X
X
38
36-38: 18code, the front one code represents department code, which is particular for the
batch management of live commodity.
36
D (1)
LLLLLL (6)
IIII (4)
RR (2)
QQ.QQQ (5)
37
D (1)
LLLLLL (6)
IIII (4)
RR (2)
QQQQ.Q (5)
38
D (1)
LLLLLL (6)
IIII (4)
RR (2)
QQQQQ (5)
Bar code type
Department
Art. No
Quantity/weight
Total/Unit price
Check sum
79~858718 code
79
DD
IIIIII(6)
WW.WWW
PPP.PP
X
80
D
IIIIII(6)
WW.WWW
PPP.PP
C
81
D
IIIIII(6)
WWWW.W
PPP.PP
C
82
D
IIIIII(6)
WWWWW
PPP.PP
C
83
D
IIIIII(6)
WW.WWW
UUU.UU
C
84
D
IIIIII(6)
WWWW.W
UUU.UU
C
85
D
IIIIII(6)
WWWWW
UUU.UU
C
87
DD
IIIII(5)
WW.WWW
PPP.PP
C
Bar code type
Department
Art. No
Total price
Quantity/weight
Unit price
Check sum
90~95: 18 code, the former two codes print department code
90
DD(2)
IIIIII(6)
WW.WWW
UU.UU(4)
C
91
DD(2)
IIIIII(6)
WWWW.W
UU.UU(4)
C
92
DD(2)
IIIIII(6)
WWWWW
UU.UU(4)
C
93
D(1)
IIIIII(6)
PPP.PP(5)
UUU.UU(5)
C
94
DD(2)
IIIII(5)
PPP.PP(5)
WW.WWW
C 95
DD(2)
IIIIII(6)
WWWWW
UU.UU(4)
C
Meaning of characters in the above list: C: CHECKSUM D: Department code 2: Fixed number I: commodity number L: Live code P: price R: discount Q: weight X: no this item Notes:
1. Ean 13= DEPMENT+CODE+[TOTAL PRICE]+[WEIGHT]+C
Items with [] mean no this item in some coding system.
2. Usually Ean13 adopts 2 or 22 as its price barcode type while 7 or 77 as its weight barcode type.
3. CHECKSUM is calculated by the scale automatically and it is not necessary for user to input in PLU
manager.
4. The difference between 30-32 and 33-35 is the method to calculate checksum.
5. The difference between 40-45 and 30-35 is that the price in 30-35 is total price while in 40-45 is unit price.
6. 36-38 is barcode type, which can be accessed by live batch management. Commodity batch number takes up
commodity number column and commodity number takes up live code column.
39
11.2 Appendix2: Main difference between LB scale and LP scale:
Main difference between scale with pole and scale without pole:
LB serial Scale (with pole)
LP Serial scale (without pole)
System set option R/T/D/B/P/A/L/H/O/M/S/I/J/X/K/E/F/C/Y/G/Q/N/U/V/W/Z/,/./
System set option R/T/D/B/P/A/L/H/O/M/S/I/J/X/K/E/F/C
Two select key (hotkey 11), (hotkey 10).
Only one select key (47key)
Switch key between Chinese character and English character (73)
Switch hotkey between Chinese character and English character (5)
Label editing key (key between on/off and change
Press change for one minute
Confirmation key Enter (hotkey 10)
Confirmation key Enter (hotkey 48)
11.3 Main difference between label scale and receipt scale
Main difference between label scale and receipt scale is that they use different sensitive paper. Their other
functions are approximately same.
DPSB01002EV-LS2X-12
Loading...