Safety Information
USE THIS HEATER ONLY AS DESCRIBED IN THIS MANUAL. ANY OTHER USE NOT RECOMMENDED BY THE MANUFACTURER MAY CAUSE FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS.
FIRE OR EXPLOSION MAY OCCUR! Heater has hot arching or
sparking parts inside. Do not use it in areas where gasoline, paint or flammable liquids are used or stored.
RISK OF FIRE. To prevent a possible fire, Do not block intakes or exhaust in any manner. Do not use on soft surfaces, like a bed where
openings may become blocked. Heater must be kept clear of all obstructions. Maintain a 3 foot minimum clearance from front and 12 inches from sides and rear. Heaters must be kept clean of lint, dirt, and debris (see maintenance instructions Page 6).
RISK OF FIRE. DO NOT use heater with extension cord. Plug the
MH-515-120 heater directly into a 120VAC receptacle. Plug the
MH-53-240 heater directly into a 208-240VAC receptacle.
OVERHEATING OR FIRE MAY OCCUR. Do not place heater
behind doors.
BURN HAZARD. This heater is hot when in use. To avoid burns,
do not let bare skin touch hot surfaces. If provided, use handles
when moving the heater
RISK OF ELECTRIC SHOCK OR INJURY. Do not run cord under
carpeting, Do not cover cord with throw rugs, runners or similar
coverings. Do not route cord under furniture or appliances. Arrange cord away form the traffic area where it will not cause a tripping hazard. Do not operate any heater with a damaged cord or plug, or after heater malfunctions, or has been dropped or damaged in any manner. Discard heater, or return to authorized service facility for examination and / or repair.
RISK OF ELECTRICAL SHOCK. Connect to properly
grounded outlets only. Do not insert or allow foreign
objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage the heater. Unplug heater before performing any maintenance or when not in use, To disconnect heater, turn control to low, then remove plug from outlet.
4003787
Factory ID: 514
Fax: 320-251-2922 • Web: www.masterindustrialproducts • Email: info@pinnacleclimate.com
1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (800) 779-3267
© 2017 Pinnacle Climate Technologies, Inc. MAEA-400
NEVER LEAVE HEATER UNATTENDED WHILE CONNECTED TO
CAUTION – RISK OF ELECTRIC SHOCK DO NOT OPEN HEATER SHELL NO USER-SERVICEABLE PARTS INSIDE
A POWER SOURCE
Safety Information
CALIFORNIA RESIDENTS: This product contains chemicals, including
lead, known to the State of California to cause birth defects or other
reproductive harm. Wash hands after handling.
Turn the electrical power off at the electrical panel board
(circuit breaker or fuse box) and lock or tag the panel board
door to prevent someone from turning on the power while you are working on the heater. When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:
Read all
instructions before
using this heater.
Extreme caution is necessary when any heater is
used by or near children or invalids.
Do not use outdoors.
This heater is not intended for use in bathrooms,
laundry areas and similar indoor locations. Never locate heater where it may fall into a bathtub or other water container.
Do not use heater in wet or moist locations.
Always locate heater on a stable and level
surface.
Do not place the heater against paperboard or
low-density berboard surfaces.
Avoid using an extension cord because the
extension cord may overheat and cause a risk of
re.
CAUTION!
HOT WHILE IN
OPERATION. DO NOT TOUCH. KEEP CHILDREN, ANIMALS, CLOTHING AND COMBUSTIBLES AWAY FROM HEATER.
RISK OF ELECTRIC SHOCK!
ALWAYS use only the electrical power (voltage
and frequency) specified on the model plate of the heater.
ALWAYS use only three-prong, grounded outlet
and extension cord.
ALWAYS unplug the heater when not in use.
ALWAYS install the heater so that it is not directly
exposed to water spray, rain, dripping water, or wind.
Keep all combustible materials away from
this heater
Minimum Clearance From Combustibles
MH-515-120 MH-53-240
Front 3 ft. 3 ft. Top 1 ft. 1 ft. Sides 1 ft. 1 ft. Rear 1 ft. 1 ft.
Look for this icon throughout the manual for helpful tips on how to assemble, use and clean your Electric Fan Heater.
© 2017, Pinnacle Climate Technologies,Inc Turbo Electric Fan Heater User’s Manual
1
NEVER LEAVE HEATER UNATTENDED WHILE CONNECTED TO
A POWER SOURCE
Specications
Model # MH-515-120 MH-53-240
BTU 5,100 10,200 Watts 1,500 3,000 Heating Area (ft2) 165 320 Power (Volts) 120V~60Hz 240V~60Hz Amps 15 20 Heat Settings 1 1
Specications subject to change without notice.
Features
MH-515-120 / MH-53-240
Function Selector
Caution Light
53-240 Only
Power Light
Heater Coil
Fan
Front Guard
Figure 1
Handle
Thermostat Knob
Adjustment Knob
Troubleshooting
Locating Your Serial Number:
Your serial number can be found on the heater’s rating label. It will begin with the letters PEFH followed by 9 digits. For Example: PEFH120900170. Have your Serial Number ready before calling customer service at 800-779-3267.
© 2017, Pinnacle Climate Technologies,Inc Turbo Electric Fan Heater User’s Manual
2
NEVER LEAVE HEATER UNATTENDED WHILE CONNECTED TO
A POWER SOURCE
Assembly Instructions
What’s In The Box
Upper Handle Bracket
(2)
24 mm Bolts (16) 7 mm Nuts (16) Small Washers (32)
Inner Lower Handle
Bracket (2)
Outer Lower Handle
Bracket (2)
Adjustment Knob
(2)
Large Washers (2) Lock Washers (2)
Side Supports
© 2017, Pinnacle Climate Technologies,Inc Turbo Electric Fan Heater User’s Manual
Handles
Leg Frame
3
NEVER LEAVE HEATER UNATTENDED WHILE CONNECTED TO
A POWER SOURCE
Assembly Instructions
1 / 2
3
5 6 / 7
Tools Needed:
Phillips Head screw driver. 7 mm open end wrench.
1. Align holes in heater leg frame with lower inner bracket.
2. Attach lower outer bracket to lower inner bracket using screws.
3. Align lower inner bracket with side support.
4. Attach side supports to heater using tilt adjustment knob.
5. Slide side supports into upper brackets, align holes and insert screws to tighten.
6. Slide upper handle brackets onto front handle, align holes and insert screws to tighten.
4
7. Slide rear handle into upper handle brackets, align holes and insert screws to tighten.
© 2017, Pinnacle Climate Technologies,Inc Turbo Electric Fan Heater User’s Manual
4
NEVER LEAVE HEATER UNATTENDED WHILE CONNECTED TO
A POWER SOURCE
Operation
Operation
1. Position the fan heater so that it stands upright on a firm, level surface and at a safe distance from wet environments and flammable objects.
2. Connect the fan heater to the proper electrical power. See Grounding instructions (Page 8 Figure 2)
3. Set the thermostat dial to the maximum temperature.
4. The fan heater will switch on when the function selector dial is set to one of the three power settings.
Setting Function
Unit is Off Fan Runs - No heating Fan Runs - Full Power Heating
NOTE: The fan will run continuously while the heater is operating.
5. Once the room reaches the desired temperature, turn the thermostat dial back until heating element turns off.
Automatic Overheat Safety Control
This heater is equipped with safety internal
heat limiting thermostat and overheat protection circuit. When a potential overheat temperature is reached, the system will automatically shut the heater off at 185 ºF (85 ºC).
Caution Light
The Caution Light will illuminate when the
Overheat Safety Control is activated. The heating element will be shut off until the unit has cooled to a safe level.
The fan will continue to operate.
Once the heater has reached a safe level
(131 ºF / 55 ºc), the heater will turn back on automatically.
Thermostat Instructions
At first, set the thermostat to “+” and let the
heater operate with full power input. When the room temperature reaches the required value, turn the thermostat to the left until it switches off.
The thermostat will then switch on and off
automatically to control the room temperature according to the preset value and keep the room temperature constant.
© 2017, Pinnacle Climate Technologies,Inc Turbo Electric Fan Heater User’s Manual
When using the heater for the first time, you
may notice a slight emission of smoke. This is quite normal and it stops after a short time. The heating element is made of steel and was coated with a layer of protective oil during production. The smoke is caused by
the leftover oil as it is heated.
5
NEVER LEAVE HEATER UNATTENDED WHILE CONNECTED TO
Grounding Instructions
A POWER SOURCE
Operation
MH-515-120:
This heater is for use on 120 Volts. The
cord has a plug as show at A (below). An adapter as shown at C is available for connecting three-blade grounding-type plugs two-slot receptacles. The green grounding lug extending from the adapter must be connected to the permanent ground such as a properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available.
Metal Screw
A
MH-53-240:
This heater is for use on 240 (or 208) volts.
The cord has a plug as shown in D (below). No adapter is available for this blade
conguration, and none should be used. The
type outlet is a 240 (or 208) volt grounding outlet. When properly installed, it provides a ground connection through the cord to the heater to protect the operator from electric shock.
Grounding Methods
C
Grounding Means
B
D
Figure 2
Cleaning and Maintenance
Before cleaning the appliance, disconnect it
from the outlet and let it cool down.
The enclosure is easy to get dirty. Wipe it
often with a soft sponge. For very dirty parts, wipe with a sponge dipped in < 122°F water and mild detergent, then dry the heater enclosure with a clean cloth. Be careful not to let the water enter the inside of the appliance
© 2017, Pinnacle Climate Technologies,Inc Turbo Electric Fan Heater User’s Manual
Grounding Pin
Maintenance
In order to protect the enclosure, do not
splash water onto the heater, and never use a solvent like gasoline, isoamyl acetate, toluene, etc. to clean the heater.
6
NEVER LEAVE HEATER UNATTENDED WHILE CONNECTED TO
A POWER SOURCE
Troubleshooting
Locating Your Serial Number:
Your serial number can be found on the heater’s rating label. It will begin with the letters PEFH followed by 9 digits. For Example: PEFH120900170. Have your Serial Number ready before calling customer service at 800-779-3267.
Problem Cause Solution
Fan stays on when heat shuts off.
Fan speed stays the same when changing settings.
Heating element does not glow red.
Do not feel heat or air ow.
1. Fan runs continuously while the heater is operating.
1. Fan speed stays constant. Setting changes amount of heat output only.
1. Heating element is made of stainless steel and will not glow red to produce heat.
1. No power to heater.
2. Desired room temperature reached.
3. Heater does not heat area in front of heater, it will disperse heat throughout room to heat entire space.
1. Heater is operating correctly.
1. Heater is operating correctly.
1. Heater is operating correctly.
1. Check power connections / connect heater to power supply.
2. Thermostat will shut off once desired room temperature is reached. Heater is operating correctly.
3. Heater is operating correctly.
© 2017, Pinnacle Climate Technologies,Inc Turbo Electric Fan Heater User’s Manual
7
NEVER LEAVE HEATER UNATTENDED WHILE CONNECTED TO
XXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXX
A POWER SOURCE
LIMITED WARRANTY
Pinnacle Climate Technologies, Inc. warrants this heater
to the original retail purchaser only, to be free from defects in material and workmanship for a period of one (1) year from the date of initial purchase. This product must be properly installed, maintained and operated in accordance with the instructions provided.
Pinnacle Climate Technologies, Inc. requires reasonable proof of your date of purchase from an authorized retailer or distributor. Therefore, you should keep your sales slip, invoice or cancelled check from the original purchase. This Limited Warranty shall be limited to the repair or replacement of parts, which prove defective under normal use and service within the warranty period, and which Pinnacle Products International , Inc. shall determine at its reasonable discretion.
This warranty does not apply to products purchased for rental use.
This Limited Warranty does not cover any failures or
operating difculties due to normal wear and tear, accident,
abuse, misuse, alteration, misapplication, improper installation or improper maintenance and service by you or any third part. Failure to perform normal and routine maintenance on the heater, shipping damage, damage related to insects, birds or animals of any kind, and damage due to weather conditions are also not covered. In addition, the Limited Warranty does not cover damage
to the nish, such as scratches, dents, discoloration, rust or
other weather damage, after purchase.
All transportation costs for the return of damaged product or parts will be the responsibility of the purchaser. Upon receipt of damaged item, Pinnacle Climate Technologies,
Inc. will examine the item and determine if defective. Pinnacle Climate Technologies, Inc. will repair or replace
and return the item, freight pre-paid.
If Pinnacle Climate Technologies, Inc. nds the item to be in normal operating condition, or not defective the item will be returned freight collect. This Limited Warranty is in lieu of all other express warranties. Pinnacle Climate Technologies, Inc. disclaims al warranties for products that are purchased from sellers other than authorized dealers or distributors.
AFTER THE PERIOD OF THE ONE (1) YEAR EXPRESS WARRANTY EXPIRES, Pinnacle Climate Technologies,
Inc. DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR APPLICATION. FURTHER, Pinnacle Climate Technologies, Inc. SHALL HAVE NO LIABILITY WHATSOEVER TO PURCHASER OR ANY THIRD PARTY FRO ANY SPECIAL, INDIRECT, PUNITIVE INCIDENTAL, OR CONSEQUENTIAL DAMAGES. Pinnacle
Climate Technologies, Inc. assumes no responsibility for any defects caused by third parties. This Limited Warranty
gives the purchaser specic legal rights; a purchaser may
have other rights depending upon where he or she lives. Some states do not allow the exclusion or limitation of special, incidental or consequential damages, or limitations on how long a warranty lasts, so the above exclusion and limitations may not apply to you.
Pinnacle Climate Technologies, Inc. does not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return or replacement of its equipment, and no such representations are binding on Pinnacle Climate
Technologies, Inc.
Always be sure to specify the model number and serial number when making any claim with Pinnacle Climate Technologies, Inc. For your convenience, use the space provided below to list this information.
Locating Your Serial Number:
Your serial number can be found on the heater’s rating label. It will begin with the letters PEFH followed by 9 digits. For Example: PEFH120900170. Have your Serial Number ready before calling customer service at 800-779-3267.
Model #:________________________________
Serial #:________________________________
Date of Purchase: ________________________
© 2017, Pinnacle Climate Technologies,Inc Turbo Electric Fan Heater User’s Manual
Serial Number Label
8
Fax: 320-251-2922 • Web: www.masterindustrialproducts.com • Email: info@pinnacleclimate.com