MH-18-PCH-A
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
Safety Information
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND
INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN. ASPHYXIATION, CARBON MONOXIDE POISONING AND / OR ELECTRIC SHOCK. ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER. IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABEL, ETC. CONTACT THE MANUFACTURER.
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR
CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THESE INSTRUCTIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNERS, DUST PARTICLES OR UNKNOWN CHEMICALS.
NOT FOR HOME OR RECREATIONAL VEHICLE USE.
Carbon Monoxide Hazard This heater produces carbon
monoxide, which has no odor. Burning the heater in an enclosed
space can kill you. Never use the heater in enclosed spaces such as a tent, a camper, any vehicle or recreational vehicle (RV), enclosed shelter, or any other enclosed areas.
If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or
loss of life.
Factory ID: 522
Fax: 320-251-2922 • Web: www.masterindustrialproducts.com • Email: info@pinnacleclimate.com
1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA Toll Free (800) 779-3267
© 2017 Pinnacle Climate Technologies, Inc. MACA-400
NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER
DANGER
WARNING
WARNING
WARNING
WARNING
WARNING
DANGER
SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE
Not for use in residential living areas or in non-adequately venti-
lated enclosed spaces. Never bring or store a propane cylinder
indoors.
DO NOT OPERATE THIS HEATER UNTIL YOU HAVE READ AND THOROUGHLY UNDERSTAND THESE SAFETY AND OPERATING INSTRUCTIONS.
Failure to comply with the precautions and instructions provided with this heater can result in death, serious bodily injury, property loss or damage from the hazards of fire, explosions, burns, asphyxiation or carbon monoxide poisoning. Only persons who can read and understand these instructions should use or service this heater.
This is an unvented portable heater. It uses air (oxygen) from the area in which it is used. Adequate combustion and ventilation air must be provided. Refer to VENTILATION on Page 9.
EXTREMELY HOT DURING OPERATION! Do Not touch any metal components while in operation. Keep gasoline and any other flammable liquids away from hater.
CALIFORNIA RESIDENTS: This product contains chemicals, including lead, known to the State of California to cause birth defects or other reproductive harm. Wash hands after handling.
Safety Information
RISK OF INDOOR AIR POLLUTION!
The products described in this manual are
propane direct-red, forced air heaters. Propane
forced air heaters are primarily intended for use for temporary heating of buildings under
construction, alteration or repair. Direct-red
means that all of the combustion products of the heater enter the heated space. This appliance
is rated at 98% combustion efciency, but does
produce small amounts of carbon monoxide. Carbon monoxide is toxic. Humans can tolerate only small amounts of carbon monoxide and so precautions should be taken to provide proper ventilation. Failure to provide proper ventilation in accordance with the instructions in this manual can result in death.
CARBON
MONOXIDE
POISONING MAY LEAD TO DEATH!
People with breathing problems should consult a physician before using this heater.
Early signs of carbon monoxide poisoning
resemble the u. Symptoms of improper
ventilation / carbon monoxide poisoning are:
Headache • Dizziness • Nausea • Dry Mouth
Sore Throat • Burning of Nose and Eyes
If you experience any of these symptoms: GET FRESH AIR AT ONCE! Have your heater serviced and check for proper ventilation. Some people are more affected by carbon monoxide than others. These include: pregnant women, those with heart or lung problems, anemia or those under the influence of alcohol or at high altitudes.
FOR OUTDOOR USE. INDOOR USE PERMITTED ONLY FOR: The temporary heating of adequately ventilated buildings or structures under construction, alteration or repair! Provide at least a three square foot (2,800 sq cm) opening of outside air for every 100,000 Btu / Hr heater rating. Refer to “Ventilation” on page 8 for further instructions.
© 2017, Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual
1
NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER
DANGER
WARNING
WARNING
WARNING
WARNING
SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE
Safety Information
PROPANE IS AN
EXPLOSIVE GAS.
WHAT TO DO IF THE SMELL OF GAS IS PRESENT:
DO NOT attempt to light the heater. Extinguish any open ame. Shut off gas to heater. If odor continues, contact your local gas
supplier or re department.
DO NOT touch or use any electric switch or
any electric device that can cause a spark.
Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers instructions.
If you can not reach your gas supplier, call
the re department.
Service must be done by a qualied
service agency.
RISK OF BURNS, FIRE AND EXPLOSION!
NEVER store or use gasoline or other ammable
vapors and liquids in the vicinity of this heater. NEVER store a propane (LP) cylinder not
connected to this heater in the vicinity of this heater. NEVER NEVER
ventilation air. NEVER use duct work in front or rear of heater. NEVER modify this heater or operate a heater that
has been modified. NEVER service, move or handle heater while still
hot or operating Keep all combustible materials away from this heater.
connect heater to an unregulated gas supply.
obstruct the flow of combustion and
Minimum Clearance From Combustibles
Front Sides Top
72 in. 12 in. 24 in.
For use with propane (LP) gas only.
ALWAYS install the heater so that it is not directly
exposed to water spray, rain, dripping water, or wind.
Use heater in accordance with all local codes
and with CSA 5.90 U.S. (5th Ed.) Infrared Patio Heater.
This heater is shipped from the factory
for use with propane (LP) gas only. Do not
convert to any other gas. Installation must conform to local codes, or in their absence, with the standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/ NFPA 58 and the Natural Gas and Propane Installation Code CSA B149.1.
Gas supply connections should be checked
by using a 50/50 soap and water solution. Never use a ame to check for gas leaks.
Use only the regulator and hose assembly
provided with this heater. Inspect the regulator/hose assembly prior to each use of the heater. If there is excessive abrasion or wear, or if the hose is cut, replace it with the proper assembly shown in the parts list, prior to using the heater.
This heater is not for use on nished oors.
Minimum and Maximum Inlet
Pressure
Model MH-18-PCH-A
Min. 5 PSI
Max. Bottle Pressure
CAUTION! HOT WHILE IN
OPERATION. DO NOT TOUCH. KEEP CHILDREN, ANIMALS, CLOTHING AND COMBUSTIBLES AWAY FROM HEATER.
© 2017, Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual
The hose assembly shall be pro tected
from traffic, building material and contact with hot surfaces both during use and while in storage.
2
NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER
WARNING
CAUTION
SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE
RISK OF FIRE! ALWAYS LOCATE HEATER ON A STABLE AND LEVEL SURFACE!
Unpacking
1. Remove all packing items applied to heater for shipment. Keep plastic cover caps attached to inlet connector and hose / regulator assembly for storage.
2. Remove all items from carton
3. Check all items for shipping damage. If the heater is damaged, promptly inform dealer where you purchased the heater.
hose assembly supplied with the heater must be used without alteration.
The Propane (LP) gas pressure regulator and
Specications
Model # MH-18-PCH-A
BTU 6,600 / 12,000 / 18,000 Fuel Consumption (Lbs./hr) 0.31 / 0.56 / 0.83 Heat Settings 3 Maximum Operating Hours 65 / 36 / 24 Required Cylinder Lbs. 20 Fuel Type Propane Heating Area (Ft.2) 165 / 300 / 450
Specications subject to change without notice.
Features
© 2017, Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual
3
NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER
CAUTION
CAUTION
SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE
Missing Parts? Please Call (800) 779-3267 For Assistance
Unpacking and Assembly
- Remove heater and base from carton (save
carton and packing materials for later storage)
- Remove all protective packaging protecting
heater during shipping.
- Place heater base on at surface with wheels
on ground.
- Line up holes in bottom of heater cabinet with
locking tabs on top of base (see gure 2)
- Mount heater cabinet to heater base, sliding
tabs through holes in bottom of cabinet and sliding cabinet backward approximately 1/4" or until cabinet will not move further back.
- Use thumbscrews to attach heater cabinet to
heater base.
- Inspect heater closely for any damage that may
have occured during shipping. If there is any damage, return the heater to place of purchase.
Connecting to Gas Supply
IMPORTANT! - Always use a propane (LP) cylinder that has a connection device that is compatible with the hose and regulator assembly supplied.
- Remove the back cover by sliding the cover straight up and away from the heater body. Place the LP cylinder on the bottom plate and replace the back cover.
- To connect LP cylinder, insert regulator end
tting into cylinder valve, rotate coupling nut clockwise and tighten rmly (see gure 3)
- Open valve on propane cylinder slowly. If the
valve is not opened slowly, the excess ow check valve in the regulator will stop the ow of
gas. If this should happen, close the valve, wait one minute (or until you hear the valve click), and re-open, slowly.
- Be sure to inspect all connections for leaks, by using a 50/50 mixture of dish soap and water on all connection. Any bubbles forming indicate a leak.
The Propane (LP) gas pressure
regulator and hose assembly supplied with the heater must be used without alteration.
Be sure to inspect the regulator hose
before each use. If the hose is cut or frayed, replace it with the manufacturer suggested assembly.
© 2017, Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual
4
NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER
CAUTION
CAUTION
WARNING
SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE
Operation
Propane Supply / Information:
Propane (LP)
This heater is not supplied with a propane cylinder. Use only an approved propane cylinder.
LP Characteristics
Flammable, explosive under pressure, heavier than air
and pools in low areas.
In its natural state, propane has no odor, but for your
safety an odor that smells like rotten cabbage has been added.
Contact of propane (LP) gas with the skin can cause
freeze burns.
Heater is manufactured for use with propane gas only.
DO NOT attempt to convert to any other gas. Such
modications are dangerous and will void the warranty.
When heater is not in use, LP Cylinder must be turned
OFF.
Be sure that the LP Cylinder is located on a level and
stable surface.
DO NOT use this heater in a basement or below ground
level. Propane is heavier than air and will always seek the lowest level. If you suspect a leak, shut off the valve at the LP Cylinder immediately.
The Propane (LP) cylinder must also be equipped with the following
A collar to protect the gas valve.
A shut-off valve terminating a LP cylinder valve outlet
as specied in the American National Standard for
Compressed Gas Cylinder Valve Outlets and Inlets Connections.
A safety relief valve having direct communications with
the vapor space of the LP cylinder.
The heater must operate on vapor withdrawal from the
operating cylinder.
Never connect an unregulated LP cylinder to a
construction heater. – DO NOT subject LP cylinder to excessive heat. – Tightly close the gas shutoff valve on the LP cylinder
after each use. – All ttings must be protected when disconnected from
the LP cylinder. – Never store an LP cylinder inside a building or in the
vicinity of an gas burning appliances.
The disconnected
tank must never be stored in a building, garage or any other enclosed area.
Pre-Lighting Instructions:
Connecting the LP Cylinder
ALL NEW LP CYLINDERS MUST BE PURGED BEFORE THE FIRST FILLING.
Turn heater gas valve knob and LP cylinder valve to
OFF position.
LP cylinder valve equipped with old style tting has
LEFT HANDED THREADS. Turn tting CLOCKWISE to loosen. Protect this tting when disconnected from LP
cylinder.
Have your LP cylinder lled by your local propane gas
supplier.
Some LP cylinders have a bleed-OFF valve. This valve
should be inspected for leaks after each lling of the LP
cylinder. Turn the valve clockwise to close.
Fasten full propane tank and connect proper tting to
LP cylinder valve by turning COUNTER-CLOCKWISE.
With heater gas valve knob still in OFF position turn
ON the LP cylinder valve and check for leaks with
soap solution.
Propane is safe to use
when properly handled. Careless handling of the LP cylinder could result in a fire and or an explosion.
Always keep LP cylinder fastened and upright. – Avoid tipping the LP cylinder on its side when
connected to a regulator, since this may cause damage to diaphragm in the regulator.
Handle valves with care.
© 2017, Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual
Purging and filling of the LP
cylinders must be performed by personnel who have been thoroughly trained in accepted LP gas industry procedures. Failure to follow these instructions may result in explosion, fire, severe personal injury or death.
5
NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER
WARNING
SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE
Operation
Checking For Leaks
Lighting Instructions:
To check for leaks, make up a 50/50 solution
of dish soap and water. Apply this solution to all gas connections. If bubbles appear, there is a leak. If a leak is found, turn off the gas supply, and re-connect the leaking connection. If the leak persists after several tries, contact Pinnacle Customer Service at (800) 779-3267.
The installation of this heater must meet all
local codes and/or gas utility requirements. In the absence of local codes, the National Fuel Code ANSI Z223.1 should be followed.
The minimum clearances to any combustible
construction materials must be maintained at all times (See Page 2).
Inspect the heater before each use, and at
least annually by a qualied service person.
Supply Valve
Regulator
1. STOP! Read all of the safety information provided with this heater.
2. Turn valve on propane cylinder COUNTERCLOCKWISE until fully open.
3. Wait ve (5) minutes for any gas to clear. Smell for gas. If none is evident, proceed to the next step.
4. Push in the valve knob and turn to "PILOT".
NOTE: If this is rst time use for heater or LP
cylinder has been replaced, hold the valve knob for approximately 30 seconds to allow bleeding of air from system then turn valve knob to PILOT.
5. While depressing the valve knob, press red piezo ignition button to ignite. It may be necessary to press the igniter button several times to ignite the center burner panel.
6. Continue to hold valve knob down for 30 seconds after the panel has lit. This will heat the thermocouple. After 30 seconds, release the valve knob.
Hose
Figure 6
Propane Tank
EXTREMELY HOT during operation.
Do Not touch any metal components while in operation. Keep gasoline and any other flammable liquids
7. If heater fails to light, or does not stay lit, repeat steps 2 through 6.
8. When the center burner panel stays lit, turn the valve knob to the desired setting.
Shut Down Instructions
1. Turn valve knob to the OFF position.
2. Turn the knob at the LP cylinder CLOCKWISE to the OFF position.
3. Disconnect regulator hose assembly from the LP cylinder.
away from the heater.
© 2017, Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual
6
NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER
DANGER
DANGER
SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE
Operation
Test Firing Heater
It is always a good idea to test re your heater in a safe
and controlled environment, in an area with adequate ventilation, and away from any combustibles to be sure that all functions of the heater and gas supply system are operating properly.
Leak test all gas connections with a 50/50 solution of
dish soap and water. DO NOT use a ame to test for
leaks!
Moving and Positioning the Heater
There is a brake in each of the front wheels of your heater that helps keep it in place when in use. To engage the brakes, push the lever down on each wheel. To move the heater, release the brakes, simply
by ipping the levers on both brakes up.
CARBON MONOXIDE POISONING MAY LEAD TO DEATH!
Ventilation
Risk of indoor air pollution and Carbon
Monoxide Poisoning. Use heater only in well ventilated areas.
Refer to Safety Information on pages 1-2
for information about Carbon Monoxide Poisoning.
ALWAYS provide a fresh air opening in the
heated space of at least 3 square feet (2,800 sq. cm) for each 100,000 BTU / Hr. of heater output. Provide a larger opening if more heaters are being used.
FOR OUTDOOR USE. INDOOR USE
PERMITTED ONLY FOR: The temporary heating of adequately ventilated buildings or structures under construction, alteration or repair.
Minimum Ventilation
Opening Needed
MH-18-PCH-A
0.54 ft.
501.7 cm
2
2
Not for use in residential living
areas or in non-adequately ventilated enclosed spaces.
© 2017, Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual
7
NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER
CAUTION
DANGER
SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE
Storage / Maintenance
Always disconnect the LP cylinder from the regulator assembly and remove the LP cylinder from the heater before putting the heater into storage. If, for any reason, the heater is to be stored indoors, the heater MUST be disconnected from the LP cylinder, and the cylinder stored outdoors in a well-ventilated area, out of the reach of children, and in accordance with the Standard for Storage and Handling of Liquefied Gasses, ANSI/NFPA 58 - latest edition. The plastic valve plug or valve cover supplied with the LP cylinder must be reinstalled on the valve to protect the fitting from damage.
NOTE: Repair of this heater should be done by a qualified service person.
It is recommended that you save all of the packaging materials that came with your heater, and re-package the heater using these materials for safe storage. Debris, dust and dirt inside of the heater body can affect the performance of your heater. This debris can impair the heaters ability to draw air for ventilation and combustion. Spiderwebs can also appear during periods of inactivity.
Be sure to inspect the heater before each use to look for any such obstructions. Be sure to keep the air passage-ways, burner and combustion areas clean. Wipe with a damp cloth or use a vacuum cleaner to clean these areas. It is suggested that you perform a thorough cleaning at least once every 30 days of operation. You may need to clean the heater more often if conditions are naturally dirty.
Clean the ceramic plaques using compressed air below 30 PSI to prevent damage to plaques.
A yellow tip of the pilot flame indicates that the burner area may be in need of cleaning.
Never store an LP cylinder inside of a building or near any other gas or oil burning appliances.
Always be sure that the heater has been allowed to cool for at least 30 minutes before attempting to store, service, or perform maintenance.
© 2017, Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual
8
NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER
SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE
Troubleshooting Guide
Locating Your Serial Number:
Your serial number can be found on the heater’s rating label. It will begin with the letters PGCV followed by 8 digits. For Example: PGCV12345678. Have your Serial Number ready before calling customer service at (800) 779-3267.
Problem Possible Cause Solution
Burner fails to ignite
No spark created when
ignited
1. Air in gas line
2. Gas pressure from cylinder too low.
3. LP cylinder valve turned off
4. Obstruction in air passageway.
5. Dirt in pilot orifice.
6. Safety switch in cylinder valve engaged.
7. Tipover switch engaged.
1. Incorrect igniter electrode position.
2. Electrode damaged or broken.
3. Loose or disconnected igniter wire.
4. Broken igniter wire.
1. Keep depressing the gas control knob for at least 30 seconds to remove any in line.
2. Check LP cylinder pressure. Tank may be empty.
3. Open LP cylinder valve.
4. Inspect and clean heater housing.
5. Blow out, or clean pilot orifice.
6. Close LP cylinder valve. Wait 1 min. for switch to click off. Reopen LP cylinder valve slowly.
7. Move heater to a level surface.
1. Properly position electrode
2. Replace the electrode.
3. Tighten or reconnect loose wire.
4. Replace igniter wire.
1. Thermocouple damaged
2. Gas control valve damaged.
3. Gas leak
Heater stops running by
itself
© 2017, Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual
4. Thermocouple not in contact
5. Tip-over switch damaged,
6. Out of fuel.
with pilot flame.
or loose connection at tip­switch.
1. Replace thermocouple.
2. Replace gas control valve.
3. Check all connections for leaks using 50/50 solution of dish soap and water. Repair any leaks found.
4. Clean inside of heater housing.
5. Inspect tip-over switch and connections. Replace if necessary.
6. Replace LP cylinder
NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER
SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE
Exploded View
3
1
Parts List
Item
Description MH-18-PCH-A
#
1 Front Castor 50-011-0110 2 Rear Castor 50-011-0210 3 Piezo Button 50-014-0100
2
© 2017, Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual
9
NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED TO A POWER
SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE
LIMITED WARRANTY
Pinnacle Climate Technologies, Inc. warrants this heater
to the original retail purchaser only, to be free from defects in material and workmanship for a period of one (1) year from the date of initial purchase. This product must be properly installed, maintained and operated in accordance with the instructions provided.
Pinnacle Climate Technologies, Inc. requires reasonable proof of your date of purchase from an authorized retailer or distributor. Therefore, you should keep your sales slip, invoice or cancelled check from the original purchase. This Limited Warranty shall be limited to the repair or replacement of parts, which prove defective under normal use and service within the warranty period, and which Pinnacle Climate Technologies , Inc. shall determine at its reasonable discretion.
This warranty does not apply to products purchased for rental use.
This Limited Warranty does not cover any failures or
operating difculties due to normal wear and tear, accident,
abuse, misuse, alteration, misapplication, improper installation or improper maintenance and service by you or any third party. Failure to perform normal and routine maintenance on the heater, shipping damage, damage related to insects, birds or animals of any kind, and damage due to weather conditions are also not covered. In addition, the Limited Warranty does not cover damage
to the nish, such as scratches, dents, discoloration, rust or
other weather damage, after purchase.
All transportation costs for the return of damaged product or parts will be the responsibility of the purchaser. Upon receipt of damaged item, Pinnacle Climate Technologies,
Inc. will examine the item and determine if defective. Pinnacle Climate Technologies, Inc. will repair or replace
and return the item, freight pre-paid.
If Pinnacle Climate Technologies, Inc. nds the item to be in normal operating condition, or not defective the item will be returned freight collect. This Limited Warranty is in lieu of all other express warranties. Pinnacle Climate Technologies, Inc. disclaims al warranties for products that are purchased from sellers other than authorized dealers or distributors.
AFTER THE PERIOD OF THE ONE (1) YEAR EXPRESS WARRANTY EXPIRES, Pinnacle Climate Technologies,
Inc. DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR APPLICATION. FURTHER, Pinnacle Climate Technologies, Inc. SHALL HAVE NO LIABILITY WHATSOEVER TO PURCHASER OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, PUNITIVE INCIDENTAL, OR CONSEQUENTIAL DAMAGES. Pinnacle
Climate Technologies, Inc. assumes no responsibility for any defects caused by third parties. This Limited Warranty
gives the purchaser specic legal rights; a purchaser may
have other rights depending upon where he or she lives. Some states do not allow the exclusion or limitation of special, incidental or consequential damages, or limitations on how long a warranty lasts, so the above exclusion and limitations may not apply to you.
Pinnacle Climate Technologies, Inc. does not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return or replacement of its equipment, and no such representations are binding on Pinnacle Climate
Technologies, Inc.
Always be sure to specify the model number and serial number when making any claim with Pinnacle Climate Technologies, Inc. For your convenience, use the space provided below to list this information.
Locating Your Serial Number:
Your serial number can be found on the heater’s rating label. It will begin with the letters PGCV followed by 8 digits. For Example: PGCV12345678. Have your Serial Number ready before calling customer service at 1-800-779-3267.
Model #:________________________________
Serial #:________________________________
Date of Purchase: ________________________
© 2017, Pinnacle Climate Technologies, Inc. Cabinet Heater User's Manual
10
Loading...