10
Selecting functions
AIR CONDITIONING FUNCTIONS
To turn the unit on in air conditioning mode,
proceed as follows:
1. Press the ON/OFF button (the signal
light will come on).
2. Rotate the function selector dial anticlockwise:
• Place the function selector in the HIGH
pos. to operate the unit in air conditioning
mode at maximum fan speed, after 3
minutes the signal light will come on ).
• Place the function selector in the LOW
pos. to operate the unit in air condtioning
mode at minimum fan speed (the signal
light will come on, and then, after 3
minutes the signal light will come on ).
3. Now set the required temperature by rotating the room thermostat dial .
Note
The temperature is not expressed in degrees.
We recommend that you turn the thermostat
dial to the maximum position. When the desired room temperature has been reached,
slowly turn the thermostat in a clockwise
direction until it arrives at the position where a
click can be heard. The signal lights (or
) will turn off.
The temperature selected in this way will
automatically be regulated and maintained,
and save energy. When regulating the thermostat, the air conditioning function is temporarily interrupted and the unit continues to
operate in fan only mode. In this way, the
appliance keeps the air temperature within
the room even.
Delay on Start Up
1. A special safety device will delay the start
of air conditionig by approximately 3 to 5
minutes when switching between functions or on initial start up.
2. You may also experience a slight delay
between changing from one function to
another.
16
15
20
16
21
15
19
10
11
VENTILATION/FILTRATION
Rotate the function selector clockwise.
• Press the ON/OFF button (the signal
light will come on).
• Place the function selector on the “FreshZo-
ne” position and choose the desired fan
speed (min/max). The signal light or
will come on).
17
10
11
19
COOL JET
The cool jet mode was conceived to provide
the appliance with a greater cooling potential. This is particularly useful when you want to
bring the temperature of a very warm room
quickly down to a more comfortable level. In
this case:
Make sure that the tank is full of water (see
page 8);
Make sure that the function selector switch
is in the HIGH position.
Press the Cool jet button .
After reaching the desired temperature, you
can release the Cool jet button and reposition the selector switch to the LOW pos.
Doing so will make the operation quiter.
22
19
18
PROBLEM WARNING LIGHT
The lighted pilot light indicates that
the safety device of the pressure switch has
switched on. In this case the appliance is
deactivated. To restore the proper functioning of the appliance, eliminate the possible
causes of the problem and press the restore
button .
The causes may be:
1) The exhaust hose forms a siphon in which
condensation water has accumulated: in
this case, it is necessary to drain the accumulated out of the machine, outwards
(never towards the air conditioner) and
eliminate the siphon on the hose.
2) The exhaust hose is obstructed: eliminate
the obstacles which obstruct the expulsion
of the air to the outside.
If, after having repositioned the drainage tube,
the machine still does not start up, the problem
might be more complicated (ex.: obstructed
ventilation fan) and could require the assistance of the Authorised Service Centre.
6
23