Pietro Fiorentini governor User Manual

governor
Line Pressure Regulators
*** APPLICATION NOTES ***
1. The Governor regulator is ANSI Z21.80a and ANSI Z21.18 certified for vent limited
installations (indoor installations where a vent line is not required) depending upon local codes and standards requirements. Per the terminology of the standard there is no "vent less regulator", they are vent limited because they can leak up to 2.5 cu.ft. per hr. (1 cu.ft. per hr. propane) per the code. The regulators per code can be installed without installing a vent line but again are technically termed "vent limited" per the standard not vent less.
2. The tables listed are guidelines in capacity. The actual capacity can differ based on inlet and outlet piping, type of equipment installed and flowing differential pressure of the system.
3. The Governor is a bubble tight full lockup regulator (it will not leak gas downstream when it shuts off). Lock up of the Governor is certified to CSA ANSI Z21.80a
standards. Lock up in any given installation can vary based on, piping, snap acting gas valve on high efficiency equipment, firing rate at the time of equipment shut off, debris in the line, temperature, as well as many other variables. You may see
variations in lock up in some installations due to the above Pietro Fiorentini will not guarantee the lock up will meet your equipment requirement due to these variations in installations and piping.
4. The low Capacity GOVERNORS 1/2" - 1" are intended for use on equipment such as unit heaters or simple on/off furnace applications.
5. Use the High Capacity GOVERNORS on all "High Efficiency" quick acting gas valve applications, such as generators, pool heaters, or high turn down boilers. Install a
regulator on each individual piece of equipment. Size the regulator at minimum 50% to 100% of listed capacity to minimize high lock-up. Make sure you match the
regulator pipe size to the pipe size of the equipments gas train and design the piping to minimize pressure drop to 1" W.C. between the regulator and the gas train.
6. Try to match the GOVERNOR regulator to the pipe size of the equipment and minimize pressure drop between the regulator and equipment to 1" W.C.. Minimize
the amount of elbows and fittings between the regulator and the equipment and use full port ball valves not plug valves or reduced port valves.
7. Be careful on applications where you increase the outlet piping more than 1 diameter. You may need to install an external control line in the larger piping. The GOVERNOR can be ordered with or retrofitted with an external control line.
8. Make sure on all installations you don't install the regulator directly at the equipment. Install the regulator 3 to 10 feet away depending on the application.
9. Never install the external brass vent limiter outdoors. For outdoors installation install
appropriate vent protection.
10. All GOVERNORS include an inlet filter. The filter and/or regulator may be cleaned by removing the bottom plate Torx security screws, bottom plate assembly, then remove the filter. The filter can then be cleaned with detergent or Buna compatable solvent and dried. The valve and orifice can be cleaned with a cloth while the bottom plate is off. Then reassemble the unit.
11. If there are ever any questions on the installation or application of the Governor regulator, immediately contact your local authorized distributor or representative.
12. The maximum inlet pressure on the regulator label is the required maximum pressure of the CSA ANSI Z21.80 rating. It is not always the maximum allowable operating inlet pressure of the regulator. The rating is a CSA requirement.
GOVERNOR
Line Pressure Regulators
Introduction
Pietro Fiorentini’s GOVERNOR line of gas regulators are designed to comply with the latest CSA and international standards for regulators suitable for indoor and outdoor installations with no modifications.
The GOVERNOR family of regulators are ideal for a wide range of residential through large industrial applications. The materials and soft parts used in the construction of the GOVERNOR regulators make them suitable for use with natural gas, LPG, Propane air and other non-corrosive gases.
All GOVERNOR regulators are equipped with balanced valve design for improved high outlet pressure accuracy regardless of Inlet pressure variation. The double diaphragm with integral vent limiter provides added security. The external vent limiter reduces piping costs and the need for costly vent piping for indoor installations and complies with CSA guidelines.* The number of high capacities and regulator options sometimes eliminates the need for separate units and significantly reduces installation costs.
Safe, Reliable and High Performance
Internal vent limiter: non removable, for indoor and outdoor installations.
External vent limiter option for indoor installations.*
Double diaphragm for added safety and greater reliability of service.
Balanced valve design gives you for increase capacity, high 500
to 1 turndown and stable regulation from low to high flow. Complete lockup in absence of gas flow, 100% bubble tight
shutoff. Filter included in high capacity model.
* As Approved by Local Codes and Standards
** Brass Vent Limiters must be removed for outdoor installation **
STANDARD MODEL
Inlet Pressure Range: 3” W.C. to 2 PSIG
OVER PRESSURE DEVICE (OPD) MODEL
Inlet Pressure Range: 7” W.C. to 5 PSIG
OVER PRESSURE DEVICE (DC) MODEL
Inlet Pressure Range: 3 PSIG to 10 PSIG
*As Approved by Local Codes and Standards
3
GOVERNOR
Line Pressure Regulators
PSIG
Standard Model
2
Main Features
CSA 6.22a-2005 ANSI Z21.80A2005 Class I
for outlet pressures up to 14” W.C. Certified
Integral Vent Limiter
CSA approved External Vent Limiter – no vent line required**
Positive 100% bubble tight lock up Inlet and Outlet test ports
500 to 1 Turndown
Specifications
Suitable for use with Natural Gas,
LPG, and other non-corrosive, clean gas
Inlet Pressure: 3” W.C. to 2 PSIG CSA approved
Max. Inlet 7.25 PSIG for non-CSA
Outlet pressure: 2" W.C. to 14" W.C. for CSA
Outlet pressure: 2" W.C. to 4.25 PSIG for non-CSA Temperature range: -40°F to 150°F
Connections: ½” thru 4”
Maximum Emergency Inlet Exposure Pressure: 80 PSIG
Suitable for Indoor or Outdoor Installation
* As Approved by Local Codes and Standards
** Brass Vent Limiters must be removed for outdoor installation **
Standard Model
Inlet Pressure Range: 3” W.C. to 2 PSIG
Vent Sizes
1/4” NPT 1/2” – 1”
1/2” NPT 11/4” – 4”
Outlet Spring Range
Green 2” W .C. to 5.1” W.C.*
Red 2.75” W .C. to 7.87” W.C.*
Black 6” W.C. to 14” W.C.*
Yellow 9.8” W.C. to 27.5” W.C.
Violet 23.6” W.C. to 59” W.C. or 0.85 to 2.13 PSIG
Orange 55” W.C. to 118” W.C. or 2 to 4.26 PSIG
*Spring is CSA outlet pressure certified
4
**
As Approved by Local Codes and Standards
GOVERNOR Standard Model
CAPACITY IN CFH FOR .60 SPECIFIC GRAVITY GAS WITH FILTER (CAPACITY WITHOUT FILTER IN BRACKETS)
Outlet Pressure Set Point
31051 ½"
8” W.C.
11” W.C.
Outlet Pressure Set Point
31052 ¾"
8” W.C.
W.C.
11”
Outlet Pressure Set Point Operating Inlet Pressure
31053 1"
8” W.C.
11” W.C.
Outlet Pressure Set Point
31150 ½"
High Capacity
8” W.C.
11” W.C.
Outlet Pressure Set Point
31151 ¾
"
8” W.C.
High Capacity 11” W.C.
Operating Inlet Pressure
14” W.C.
306
218
1 PSIG
(360)
(256)
552 785
(649)
511 788
(601)
2 PSIG
Operating Inlet Pressure
369
263
495
353
(450)
(321)
(585)
(417)
665 946
(812)
616 950
(751)
(1,055)
893 1,270
(977)
826 1,274
Operating Inlet Pressure
675
(855)
481 1,127 1,738
(609)
1,218
(1,543)
(1,428)
1,731
Operating Inlet Pressure
788 1,421
(1,080)
561 1,315 2,028
(770)
(1,949)
(1,803)
2,020
(923)
(927)
(1,154)
(1,158)
(1,500)
(1,506)
(2,193)
(2,201)
(2,771)
(2,781)
Outlet Pressure Set Point
31152 1"
High Capacity
8” W.C.
11” W.C.
Outlet Pressure Set Point
31153 1¼
"
8” W.C.
11” W.C.
Outlet Pressure Set Point
31154 1½"
8” W.C.
11” W.C.
Outlet Pressure Set Point
31155 2"
8” W.C.
11” W.C.
Outlet Pressure Set Point
31156/F 2½" 8” W.C.
11” W.C.
Outlet Pressure Set Point
31157/F 3"
8” W.C.
11” W.C.
Operating Inlet Pressure
990
(1,283)
706 1,653
(914)
1,786
(2,314)
(2,142)
Operating Inlet Pressure
2,071
(3,062)
1,476 3,457 5,330
(2,183)
3,735 5,311
(5,522)
(5,110)
Operating Inlet Pressure
2,567 4,629 6,581
1,829 4,284 6,605
(3,197)
(2,279)
(5,766)
(5,336)
Operating Inlet Pressure
5,179 9,339 13,278
3,691 8,643 13,327
(5,854)
(4,173)
(10,557)
(9,770)
Operating Inlet Pressure
6,530 11,775 16,741
4,655 10,898 16,803
7,205 12,993 18,473
5,136 12,025 18,542
(7,431)
(5,297)
Operating Inlet Pressure
(9,007)
(6,240)
(13,399)
(12,401)
(16,242)
(15,032)
2,540
2,549
(3,290)
(3,302)
(7,851)
(7,880)
(8,197)
(8,228)
(15,009)
(15,065)
(19,051)
(19,121)
(23,092)
(23,177)
31158/F 4"
Outlet Pressure Set Point
8” W.C.
11” W.C.
9,149
(15,762)
(11,236)
12,835 23,145
Operating Inlet Pressure
32,906
33,027
21,420
(28,424)
(26,306)
(40,411)
(40,560)
NOTE: Flow rates are actual stated recommended capacities, for optimal performance.
For additional sizing, visit www.GasInside.com • 888.618.8787
5
GOVERNOR
Line Pressure Regulators
PSIG
Over Pressure Device (OPD) Model
Main Features
Worker & Monitor for added Safety CSA Certified 6.22a-2005 ANSI Z21.80A2005 Class I for outlet
pressures up to 14" W.C. and inlet pressures up to 5 PSIG
5
Over Pressure Device (OPD) Model
Inlet Pressure Range: 7” W.C. to 5 PSIG
CSA Certified 6.22a-2005 ANSI Z21.80A2005 Class II for outlet
pressures up to 1 PSIG and inlet pressures up to 5 PSIG
Integral Vent Limiter
CSA approved External Vent Limiter – no vent line required**
Positive 100% bubble tight lockup
Inlet and Outlet test ports
500 to 1 Turndown
Specifications
Suitable for use with Natural Gas, LPG, and other non-corrosive, clean gas
Inlet Pressure: 7” W.C. to 5 PSIG CSA approved
Max. Inlet 7.25 PSIG for non-CSA Outlet pressure: 2" W.C. to 14" W.C. for CSA Class I
Outlet pressure: 2" W.C. to 1 PSIG for CSA Class II Outlet pressure: 2" W.C. to 4.25 PSIG for non-CSA Temperature range: -40°F to 150°F
Connections: ½” thru 4”
Maximum Emergency Inlet Exposure Pressure: 80 PSIG
Suitable for Indoor or Outdoor Installation
** Brass Vent Limiters must be removed for outdoor installation **
Vent Sizes
1/4” NPT 1/2” – 1”
1/2” NPT 11/4” – 4”
Outlet Spring Range
Green 2” W .C. to 5.1” W.C.*
Red 2.75” W .C. to 7.87” W.C.*
Black 6” W.C. to 14” W.C.*
Yellow 9.8” W.C. to 27.5” W.C.*
Violet 23.6” W.C. to 59” W.C. or 0.85 to 2.13 PSIG *
Orange 55” W.C. to 118” W.C. or 2 to 4.26 PSIG
*Spring is CSA outlet pressure certified
6
**
As Approved by Local Codes and Standards
GOVERNOR Over Pressure Device (OPD) Model
CAPACITY IN CFH FOR .60 SPECIFIC GRAVITY GAS WITH FILTER (CAPACITY WITHOUT FILTER IN BRACKETS)
Outlet Pressure Set Point
8” W.C.
31051OPD ½"
11” W.C.
14” W.C.
Outlet Pressure Set Point Operating Inlet Pressure
8” W.C.
31052OPD ¾"
11” W.C.
14” W.C.
Outlet Pressure Set Point Operating Inlet Pressure
8” W.C.
31053OPD 1"
11” W.C. 14” W.C.
Outlet Pressure Set Point Operating Inlet Pressure
31150OPD ½" High Capacity
8” W.C.
11” W.C.
14” W.C.
Outlet Pressure Set Point Operating Inlet Pressure
31151OPD ¾"
High Capacity
8” W.C.
11” W.C.
14” W.C.
Outlet Pressure Set Point Operating Inlet Pressure
31152OPD 1"
High Capacity
8” W.C.
11” W.C.
14” W.C.
Outlet Pressure Set Point Operating Inlet Pressure
31153OPD 1¼"
8” W.C. 11” W.C.
14” W.C.
Outlet Pressure Set Point Operating Inlet Pressure
8” W.C.
31154OPD 1 ½"
11” W.C.
14” W.C.
Outlet Pressure Set Point
31155OPD 2"
8” W.C.
11” W.C.
14” W.C.
13,278
13,327
13,375
Outlet Pressure Set Point Operating Inlet Pressure
8” W.C.
31156OPD 2 ½"
11” W.C.
14” W.C.
16,865
Outlet Pressure Set Point
31157OPD 3”
8” W.C.
11” W.C.
14” W.C.
18,473
18,542
18,610
Outlet Pressure Set Point Operating Inlet Pressure
31158OPD 4"
8” W.C.
11” W.C.
14” W.C.
32,906
33,027
33,149
NOTE: Flow rates are actual stated recommended capacities, for optimal performance.
For additional sizing, visit www.GasInside.com • 888.618.8787
Operating Inlet Pressure
3 PSIG 5 PSIG
785
788
790
946
950
953
1,270
1,274
1,279
1,731
1,738
1,744
2,020
2,028
2,035
2,540
2,549
2,558
5,311
5,330
5,350
6,581 (8,197)
6,605
6,629
(923)
(927)
(930)
(1,154)
(1,158)
(1,163)
(1,500)
(1,506)
(1,512)
(2,193)
(2,201)
(2,209)
(2,771)
(2,781)
(2,791)
(3,290)
(3,302)
(3,314)
(7,851)
(7,880)
(7,909)
(8,228)
(8,258)
785
788
790
946
950
953
1,270
1,274
1,279
1,731
1,738
1,744
2,020
2,028
2,035
2,540
2,549
2,558
5,311
5,330
5,350
6,581 (8,197)
6,605
6,629
Operating Inlet Pressure
13,278
13,327
13,375
16,741
16,803
16,865
16,741
16,803
(15,009)
(15,065)
(15,120)
(19,051)
(19,121)
(19,191)
Operating Inlet Pressure
(23,092)
(23,177)
(23,262)
(40,411)
(40,560)
(40,709)
18,473
18,542
18,610
32,906
33,027,
33,149
(923)
(927)
(930)
(1,154)
(1,158)
(1,163)
(1,500)
(1,506)
(1,512)
(2,193)
(2,201)
(2,209)
(2,771)
(2,781)
(2,791)
(3,290)
(3,302)
(3,314)
(7,851)
(7,880)
(7,909)
(8,228)
(8,258)
(15,009)
(15,065)
(15,120)
(19,051)
(19,121)
(19,191)
(23,092)
(23,177)
(23,262)
(40,411)
(40,560)
(40,709)
7
GOVERNOR
Line Pressure Regulators
PSIG
Over Pressure Device (DC) Model
10
Main Features
2 stage out for added Safety
CSA Certified 6.22a-2005 ANSI Z21.80A2005 Class I for outlet
pressures up to 1 PSIG and inlet pressures up to 10 PSIG
CSA Certified 6.22a-2005 ANSI Z21.80A2005 Class II for outlet
pressures up to 1 PSIG and inlet pressures up to 10 PSIG
Two stage regulation for Over Pressure Protection
Intergal Vent Limiter
CSA approved External Vent Limiter – no vent line required**
Positive100% bubble tight lockup
Inlet and Outlet test ports
500 to 1 Turndown
Specifications
Suitable for use with Natural Gas,
LPG, and other non-corrosive, clean gas
Inlet Pressure: 3 PSIG to 10 PSIG
Max. Inlet 10 PSIG for CSA and non-CSA
Outlet pressure: 2" W.C. to 14" W.C. for CSA Class I
Outlet pressure: 2" W.C. to 1 PSIG for CSA Class II Outlet pressure: 2" W.C. up to 4.25 PSIG for non-CSA
Temperature range: -40°F to 150°F
Connections: ½” thru 4”
Maximum Emergency Inlet Exposure Pressure: 80 PSIG
Suitable for Indoor or Outdoor Installation
** Brass Vent Limiters must be removed for outdoor installation **
6
Over Pressure Device (DC) Model
Inlet Pressure Range: 3 PSIG to 10 PSIG
Vent Sizes
1/4” NPT 1/2” – 1”
1/2” NPT 11/4” – 4”
Outlet Spring Range
Green 2” W .C. to 5.1” W.C.*
Red 2.75” W .C. to 7.87” W.C.*
Black 6” W.C. to 14” W.C.*
Yellow 9.8” W.C. to 27.5” W.C.*
Violet 23.6” W.C. to 59” W.C. or 0.85 to 2.13 PSIG *
Orange 55” W.C. to 118” W.C. or 2 to 4.26 PSIG
*Spring is CSA outlet pressure certified
**
As Approved by Local Codes and Standards
GOVERNOR Over Pressure Device (DC) Model
CAPACITY IN CFH FOR .60 SPECIFIC GRAVITY GAS WITH FILTER (CAPACITY WITHOUT FILTER IN BRACKETS)
Outlet Pressure Set Point Operating Inlet Pressure
10 PSIG
785
788
790
946
950
953
1,270
1,274
1,279
1,731
1,738
1,744
2,020
2,028
2,035
2,540
2,549
2,558
5,311
5,330
5,350
6,581
6,605
6,629
13,278
13,327
13,375
18,473
18,542
18,610
32,906
33,027
33,149
(923)
(927)
(930)
(1,154)
(1,158)
(1,163)
(1,500)
(1,506)
(1,512)
(2,193)
(2,201)
(2,209)
(2,771)
(2,781)
(2,791)
(3,290)
(3,302)
(3,314)
(7,851)
(7,880)
(7,909)
(8,197)
(8,228)
(8,258)
(15,009)
(15,065)
(15,120)
(23,092)
(23,177)
(23,262)
(40,411)
(40,560)
(40,709)
31051DC ½
31052DC ¾”
31053DC 1
31150DC ½”
High Capacity
31151DC ¾”
High Capacity
31152DC 1”
High Capacity
31153DC 1¼”
31154DC 1½”
31155DC 2”
31157DC 3”
31158DC 4”
8” W.C.
11” W.C.
14” W.C.
Outlet Pressure Set Point
8” W.C.
11” W.C.
14” W.C.
Outlet Pressure Set Point
8” W.C.
11” W.C.
14” W.C.
Outlet Pressure Set Point
8” W.C.
11” W.C.
14” W.C.
Outlet Pressure Set Point
8” W.C.
11” W.C.
14” W.C.
Outlet Pressure Set Point
8” W.C.
11” W.C.
14” W.C.
Outlet Pressure Set Point
8” W.C.
11” W.C.
14” W.C.
Outlet Pressure Set Point
8” W.C.
11” W.C.
14” W.C.
Outlet Pressure Set Point
8” W.C.
11” W.C.
14” W.C.
Outlet Pressure Set Point
8” W.C.
11” W.C.
14” W.C.
Outlet Pressure Set Point
8” W.C.
11” W.C.
14” W.C.
3 PSIG
785
788
790
(923)
(927)
(930)
5 PSIG
785
788
790
Operating Inlet Pressure
946
950
953
(1,154)
(1,158)
(1,163)
946
950
953
Operating Inlet Pressure
1,270
1,274
1,279
(1,500)
(1,506)
(1,512)
1,270
1,274
1,279
Operating Inlet Pressure
1,731
1,738
1,744
(2,193)
(2,201)
(2,209)
1,731
1,738
1,744
Operating Inlet Pressure
2,020
2,028
2,035
(2,771)
(2,781)
(2,791)
2,020
2,028
2,035
Operating Inlet Pressure
2,540
2,549
2,558
(3,290)
(3,302)
(3,314)
2,540
2,549
2,558
Operating Inlet Pressure
5,311
5,330
5,350
(7,851)
(7,880)
(7,909)
5,311
5,330
5,350
Operating Inlet Pressure
6,581 (8,197) 6,581
6,605
6,629
(8,228)
(8,258)
6,605
6,629
Operating Inlet Pressure
(15,009)
13,278
13,327
13,375
(15,065)
(15,120)
13,278
13,327
13,375
Operating Inlet Pressure
18,473
18,542
18,610
(23,092)
(23,177)
(23,262)
18,473
18,542
18,610
Operating Inlet Pressure
32,906
33,027
33,149
(40,411)
(40,560)
(40,709)
32,906
33,027
33,149
(923)
(927)
(930)
(1,154)
(1,158)
(1,163)
(1,500)
(1,506)
(1,512)
(2,193)
(2,201)
(2,209)
(2,771)
(2,781)
(2,791)
(3,290)
(3,302)
(3,314)
(7,851)
(7,880)
(7,909)
(8,197)
(8,228)
(8,258)
(15,009)
(15,065)
(15,120)
(23,092)
(23,177)
(23,262)
(40,411)
(40,560)
(40,709)
NOTE: Flow rates are actual stated recommended capacities, for optimal performance.
For additional sizing, visit www.GasInside.com • 888.618.8787
9
GOVERNOR Standard Model - Dimensions
DIMENSIONS (IN INCHES)
Model # Size A B C D E F
Weight
(Lbs)
31051
31052
31053
31150
31151
31152
31153 1 1/4” NPT
31154
31155
31156/F
31157/F
31158/F
1/2” NPT
3/4” NPT
1” NPT
1/2” NPT 5.43
3/4” NPT 5.28
1” NPT 5.28 - 1
1 1/2” NPT
2” NPT
2 1/2 FLANGED
3” FLANGED
4” FLANGED
4.29
4.29
4.29
7.64
7.64
9.29 - 2
-
-
-
GOVERNOR Over Pressure Device (OPD) Model & Dual Cut (DC) Model - Dimensions
1/2
-
- 3/4
1
-
1/2
-
3/4
-
1 1/4
-
1 1/2
-
16.9
3
ANSI 150
3
16.9
16.9
ANSI 150 -
ANSI 150 -
4
17.09 27.56
-
17.09 27.56
19.76 27.56
- 1.54
- 1.54
- 1.54
- 2.75
- 2.75
- 2.75
- 7.5
- 7.5
- 5.59
- 5.59
- 5.59
- 6.89
- 6.89
- 6.89
- 10
- 10
12.44
- 13.74 12.34
DIMENSIONS (IN INCHES)
Model # Size A B C D E F
31051
31052
31053
31150
31151
31152
31153
31154
31155
31156/F
31157/F
31158/F
10
1/2” NPT 8.86
3/4” NPT 8.86
1” NPT 8.86
1/2” NPT 11.22
3/4” NPT 11.22
1” NPT 11.22
1 1/4” NPT 16.61
1 1/2” NPT 16.61
2” NPT
2 1/2” FLANGED 3” FLANGED 4” FLANGED ANSI 150
19.88
- 33.93
- 33.93
- 33.93
For additional sizing, visit www.gasinside.com
- 1/2
- 3/4
- 1
- 1/2
- 3/4
- 1
-
-
-
1 1/4
1 1/2
2
3 3 4
- 5.59
- 5.59
- 5.59
- 6.89
- 6.89
- 6.89
- 10
- 10
- 12.44
ANSI 150 ANSI 150
- 3.25
- 3.25
- 3.25
- 5.75
- 5.75
- 5.75
- 15.5
- 15.5
13.74
- 17.09
- 17.09
- 19.76
Weight
(Lbs)
25
56
56
56
Warranty Policy
The Seller undertakes to remedy any defects, lack of quality or nonconformity of the goods contract for which he is responsible, provided such defects have been notified in accordance within 10 (ten) days from the occurrence. The Seller may either repair or replace the goods which have shown to be defective.
In case of repair, request to return product(s) for repair must be pre-approved in writing by our Sales Department. The product(s) shall be returned pre-paid to Pietro Fiorentini USA. Seller is not responsible for defects due to: natural wearing, Buyer’s inexperience, negligence, tampering or wrong assemblage, overcome of limits conditions, non authorized intervention, force majeure or fault of the Buyer. The duration of the guarantee is twenty four months from delivery of goods.
The present warranty is not enforceable in case of lack of payment in the agreed terms. It is agreed that the obligation to repair or replace the defective goods is in lieu of any other legal guarantee or liability of the Seller,
whether contractual or noncontractual, which may arise out of or in relation with the goods supplied (e.g. compensation of damages, loss of profit, recall campaigns, etc.). For goods that have been purchased from sub-suppliers, the warranty guarantee granted by them is herewith extended to the Buyer.
Materials
Body & Cover: Aluminum Alloy
External Coatings: Polyurethane paint on request
Diaphragm, O Rings & Valve: Nitrile Rubber
Diaphragm Pan: Aluminized Steel
www.GasInside.com • 888.618.8787
11
Residential and Commerical Applications
DIVAL 600DIVAL 500
Pietro Fiorentini USA 4555 South Berkeley Lake Road Norcross, GA 30071
Toll Free: 800-554-1036
Fax: 770.448.7312
www.fiousa.com www.gasinside.com
NORVAL
The data enclosed is not binding. We reserve the right to make eventual changes without prior notice.
CT-s581-US August 2016