PIE Practical Instrument Electronics 211 Data sheet

Page 1
Practical Instrument Electronics
841 Holt Road #1 Webster, NY 14580 Tel: 585.872.9350 Fax: 585.872.2638 sales@piecal.com www.piecal.com
Automated RTD Calibrator
• Easy to use
With the PIECAL 211 you can check & calibrate all your RTD instruments and measure RTD Sensors. Automatic indication of connections on the display for simple hookups.
• Take it into the shop, plant or field
Carry it without worry - it comes protected with a rubber boot and rugged, low profile switch. Easy to operate even in the dark areas of the plant with the backlit display.
Stop carrying around a decade box and RTD resistance tables. The PIECAL 211 works with the RTDs you use including Platinum 100 (alpha = 3850, 3902, 3926) & 1000 (alpha = 3850, 3750) Ohm, Copper 10 & 50 Ohm, Nickel 100 and 120 Ohm. Easily set any value quickly to within 0.1° with the adjustable digital potentiometer “DIAL” plus store any three temperatures for instant recall with the EZ-CHECK™ switch. Or use like a decade box from 0.00 to 410.00 and from 410.0 to 2010.0 Ohms.
PIECAL 211
Fast calibration with automatic output stepping
Choose between 2, 3, 5, 11 and 21 steps to automatically increment the output in 100%, 50%, 25%, 10% or 5% of span. Select the step time to match your system from 5, 6, 7, 8, 10, 15, 20, 25, 30 and 60 seconds.
• Compatible with ALL process instruments
No competitor’s calibrator is compatible with as many process instruments! Connect directly to the RTD inputs of smart transmitters, PLCs, DCS and multichannel recorders and verify their outputs or displays. Works with older instruments with fixed excitation currents and newer multichannel instruments that switch the excitation current between input channels.
Actual Size
• Measure RTD sensors
Trouble shoot sensor connections and find broken wires with patented technology. Connect your two, three or four wire RTDs and the PIECAL 211 automatically detects the connections and measures the RTD in degrees C or F.
• Evolutionary design
PIECAL Calibrators are designed and built by members of the same team that designed and built the calibrators manufactured by Fluke* under the Altek* label. The PIECAL 211 improves upon other brands by including a rubber boot, tilt stand, backlit display with larger digits, rugged switches and a battery compartment for fast battery changes.
* PIECAL Calibrators are not manufactured or distributed by Fluke Corp or Altek Industries Inc, manufacturers of Altek Calibrators.
Page 2
Practical Instrument Electronics
841 Holt Road #1 Webster, NY 14580
Tel: 585.872.9350 Fax: 585.872.2638
sales@piecal.com www.piecal.com
Copyright © 2009 All rights reserved 211-9001 - Rev B 9 Feb 2010
PIECAL 211 Specifications
(Unless otherwise indicated all specifications are rated from a nominal 23°C, 70% RH for 1 year from calibration)
General
Accuracy ±(0.025% of Reading + 0.05 Ohms)
Temperature Drift
Operating Temperature Range
Relative Humidity Range 10 % ≤RH ≤90 % (0 to 35 °C), Non-condensing
Size L=5.63 x W=3.00 x H=1.60 inches
Weight 12.1 ounces (including boot & batteries)
Batteries Four “AA” Alkaline 1.5V (LR6)
Battery Life 50 Hours
Optional NiMh Rechargeable battery kit
Low Battery Low battery indication with nominal 1 hour of
Protection against misconnection
Display High contrast graphic liquid crystal display. LED
± 0.01% of span outside of 23°C ±10 °C (73°C ±18 °F)
-25 to 60 °C (-10 to 140 °F)
10 % ≤RH≤ 70 % (35 to 60 °C), Non-condensing
120 VAC for North America Only; charger, four NiMh batteries, AC & DC cords [Part # 020-0103]
operation left
Over-voltage protection to 60 V dc (rated for 30 seconds)
backlighting for use in low lit areas.
Ranges & Accuracies
RTD
Type
Pt 100 Ohm
DIN/IEC/JIS 1989
Based on ITS-90
Pt 100 Ohm
(Burns)
Pt 100 Ohm
(Old JIS 1981)
Pt 100 Ohm
(US Lab)
Pt 1000 Ohm
DIN/IEC/JIS 1989
Pt 1000 Ohm Hy-Cal HVAC
Copper 10 Ohm
(Minco)
Copper 50 Ohm
Ni 120 Ohm
(Pure)
Ni 110
(Bristol 7 NA)
Alpha Degrees C
Range
1.3850
(0.00385)
1.3902
(0.003902)
1.3916
(0.003916)
1.3926
(0.003926)
1.3850
(0.00385)
1.3750
(0.00375)
1.4274
(0.004274)
1.4280
(0.00428)
1.6720
(0.00672)
1.5801
(0.005801)
-200.0 to 200.0
200.0 to 600.0
600.0 to 850.0
-195.6 to 200.0
200.0 to 648.9
-200.0 to 200.0
200.0 to 648.9
-200.0 to 100.0
100.0 to 700.0
700.0 to 850.0
-200.0 to 200.0
200.0 to 266.0
-200.0 to 200.0
200.0 to 274.0
-200.0 to 260.0
-50.0 to 150.0
-80.0 to 260.0
-100.0 to 260.0
°C
±0.2° ±0.3° ±0.4°
±0.2° ±0.3°
±0.2° ±0.3°
±0.2° ±0.3° ±0.4°
±0.2° ±0.3°
±0.2° ±0.3°
±2.0°
±1.0°
±0.1°
±0.2°
Degrees F
Range
-328.0 to 392.0
392.0 to 1112.0
1112.0 to 1562.0
-320.0 to 392.0
392.0 to 1200
-328.0 to 392.0
392.0 to 1200
-328.0 to 212.0
212.0 to 1292.0
1292.0 to 1562.0
-328.0 to 392.0
392.0 to 511.0
-328.0 to 392.0
392.0 to 525.0
-328.0 to 500.0
-58.0 to 302.0
-112.0 to 500.0
-148.0 to 500.0
°F
±0.4° ±0.6° ±0.7°
±0.4° ±0.6°
±0.4° ±0.6°
±0.4° ±0.6° ±0.7°
±0.4° ±0.6°
±0.4° ±0.6°
±4.0°
±1.6°
±0.2°
±0.3°
Read
Excitation Current
Normal Mode Rejection 50/60 Hz, 50 dB
Common Mode Rejection 50/60 Hz, 120 dB
Source
Accuracy
From 1 to 10.2 mA
External Excitation Current
Below 1 mA of External Excitation Current
Resistance Ranges 0.00 to 410.00, 410.1 to 2001.0 Ohms
Allowable Excitation Current Range
Pulsed Excitation Current Compatibility
0.5 mA nominal
±(0.025% of Reading + 0.05 Ohms)
±(0.025% of Rdg + + 0.05 Ohms)
<410 Ohms: 10.2 mA max; steady or pulsed/intermittent 410 to 2001 Ohms: 1 mA max; steady or pulsed/
intermittent
DC to 0.01 second pulse width
0.025 mV
mA Excitation Current
Accessories
Included:
Rubber Boot, Four “AA” Alkaline batteries, Certificate of Calibration Small Carrying Case with PIE Logo Part No. 020-0205 Evolution RTD Wire Kit Part No. 020-0208
2 Red & 2 Black Leads with Retractable Shield Banana Plugs & Spade Lugs
Optional:
Ni-MH 1 Hour Charger with 4 Ni-MH AA Batteries Part No. 020-0103 (100-120 V AC input for North America Only)
Additional Information
PIE Calibrators are manufactured in the USA. calibrated on equipment traceable to NIST and includes a Certificate of Calibration. Test Data is available for an additional charge.
Practical Instrument Electronics recommends a calibration interval of one year. Contact your local representative for recalibration and repair services.
This product is
Warranty
Our equipment is warranted against defective material and workmanship (excluding batteries) for a period of three years from the date of shipment. Claims under warranty can be made by returning the equipment prepaid to our factory. The equipment will be repaired, replaced or adjusted at our option. The liability of Practical Instrument Electronics (PIE) is restricted to that given under our warranty. No responsibility is accepted for damage, loss or other expense incurred through sale or use of our equipment. Under no condition shall Practical Instrument Electronics, Inc. be liable for any special, incidental or consequential damage.
Available From: