Pico Macom SPI-14/18-2150 Installation And Operation Manual

Installation and
Operation Manual
SPI-14/18-2150
400-2150MHz Satellite Inline Power Inserters
Operation
Manual
Rev. 06/03
www.picomacom.com
SPI-14/18-2150 Manual.qxd 10/20/03 9:32 AM Page 1
SPI-14/18-2150
2
Rev. 06/03
www.picomacom.com
The lightning flash with arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the presence of un-insulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Product Inspection
Inspect the equipment for shipping damage. Should any damage be discovered, immediately file a claim with the carrier.
Important Safety Instructions
To insure proper installation and operation, take a moment to read this guide before proceeding with the installation. If you have any questions
or comments about the SPI-14/18-2150 400-2150MHz Satellite Inline Power Inserters, please contact your dealer or have him contact the PICO
MACOM
Service Center at these phone numbers: 800-421-6511, 818-493-4300.
1. Read Instructions: All safety and operating instructions should
be read before the appliance is operated.
2. Retain Instructions: The safety and operating instructions
should be retained for future reference.
3. Heed Warnings: All warnings on the appliance should be
adhered to.
4. Follow Instructions: All operating and user instructions should
be followed.
5. Cleaning: Unplug this appliance from the wall outlet before clean-
ing. Use a damp cloth for cleaning. Do not use liquid cleaners or aerosol cleansers.
6. Do Not Use Attachments: Use of attachments not recommend-
ed by the manufacturer may cause hazards.
7. Water and Moisture: Do not use this product near water—for
example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool—and the like.
8. Accessories: Do not place this product on an unstable cart,
stand, tripod, bracket, or table.The product may fall, causing serious injury to a child or adult, and serious damage to the appliance.
9. Ventilation: This video product should never be placed near or
over a radiator or heat register. This video product should not be placed in a built-in installation such as a bookcase or rack unless proper ventilation is provided or the manufacturer’s instructions have been adhered to. Any slots or opening in the cabinet are provided for ventilation. To ensure reliable operation of the video product and to protect it from overheating, these openings must not be blocked or covered. Openings should never be blocked by placing the product on a bed, sofa, rug, or other similar surface.
10. Grounding or Polarization: This video product is equipped with
either a three prong plug for 110 VAC use or a two prong flat blade 220 volt type plug. Each type is to be inserted into only the type of receptacle for which they specifically designed. Do not cut off the round grounding pin in order to be able to fit into a two prong recep­tacle as this could cause injury and will void the warranty.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE
TO RAIN OR MOISTURE. DO NOT OPEN THE CABINET. REFER SERVICING TO QUALIFIED PERSONNEL ONLY.
CAUTION: TO PREVENT ELECTRIC SHOCK DO NOT USE THIS (POLARIZED) PLUG WITH AN EXTENSION
CORD RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.
ATTENCION: POUR PREVENIR LES CHOCS ELECTRIQUES, NE PAS UTILISER CETTE FICHE POLARISEE AVEC
UN PROLONGATEUR, UNE PRISE DE COURANT OU UNE AUTRE SORTIE DE COURANT, SAUF SI LES LAMES PEUVENT ETRE INSEREES A FOND SANS EN LAISSER AUCUNE PARTIE A DECOUVERT.
Safeguards
SPI-14/18-2150 Manual.qxd 10/20/03 9:32 AM Page 2
SPI-14/18-2150
3
Rev. 06/03
www.picomacom.com
Safeguards
11. Power Sources: This product should be operated only from the
type of power source indicated on the marking label. If you are not sure of the type of power supplied to your home, consult your appli­ance dealer or local power company.
12. Power-cord Protection: Power-supply cords should be routed
so they are not likely to be walked on or pinched by items placed upon or against them. Pay particular attention to cords and plugs, conven­ience receptacles, and the point where they exit from the appliance.
13. Lightning: For added protection for this product during a lightning
storm, or when it is left unattended or unused for long periods of time, the unit should be disconnected from power source.
14. Power Lines: An outside antenna system should not be located
in the vicinity of overhead power lines, other electric light or power cir­cuits, where it can fall into such power lines or circuits.When installing an outside antenna system, extreme care should be taken to keep from touching such power lines or circuits as contact with them may be fatal.
15. Overloading: Do not overload wall outlets and extension cords as
this can result in risk of fire or electric shock.
16. Object and Liquid Entry: Never push objects of any kind into this
product through openings as they may touch dangerous voltage points or short-out parts that could result in a fire or electric shock. Never spill liquid of any kind on the product.
17. Servicing: Do not attempt to service this product yourself as
opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.
18. Damage Requiring Service: Unplug this product from the wall
outlet and refer servicing to qualified service personnel under the fol­lowing conditions:
a. When the power-supply cord or plug is damaged. b. If liquid has been spilled, or objects have fallen into the product. c. If the product has been exposed to rain or water. d. If the product does not operate normally by following the oper-
ating instruction. Adjust only those controls that are covered by the operating instructions. An improper adjustment may result in damage and will often require extensive work by a qualified tech­nician to restore the product to its normal operation.
e. If the product has been dropped or the cabinet has been
damaged.
f. When the product exhibits a distinct change in performance—
this indicates a need for service.
19. Replacement Parts: When replacement parts are required, be
sure the service technician has used replacement parts specified by the manufacturer or have the same characteristics as the original parts. Unauthorized substitutes may result in fire, electric shock or other hazards.
20. Safety Check: Upon completion of any service or repairs to this
product, ask the service technician to perform safety checks to deter­mine that the product is in proper operating conditions.
21. Outdoor Antenna Grounding: Before attempting to install this
product, be sure the antenna or cable system is grounded so as to
provide some protection against voltage surges and built-up static charges.
a. Use No.10 AWG (5.3mm) copper, No.8 AWG (8.4mm) alu-
minum, No.7 AWG (10mm) copper-clad steel or bronze wire or larger, as ground wire.
b. Secure antenna lead-in and ground wires to house with stand-
off insulators spaced from 4 feet (1.22m) to 6 feet (1.83m) apart.
c. Mount antenna discharge unit as close as possible to where
lead-in enters house.
d. A driven rod may be used as the grounding electrode where
other types of electrode systems do not exist. Refer to the National Electrical Code, ANSI/NFPA 70-1984 for information.
e. Use jumper wire not smaller than No.6 AWG (13.3mm) copper
or equivalent, when a separate antenna grounding electrode is used.
NOTE TO THE CATV SYSTEM INSTALLER
THIS REMINDER IS PROVIDED TO CALL THE CATV SYSTEM
INSTALLER’S ATTENTION TO ARTICLE 820-22 OF THE NEC THAT PROVIDES GUIDELINES FOR PROPER GROUNDING AND, IN PARTICULAR, SPECIFIES THAT THE CABLE GROUND SHALL BE CONNECTED TO THE GROUNDING SYSTEM OF THE BUILDING, AS CLOSE TO THE POINT OF CABLE ENTRY AS PRACTICAL.
SPI-14/18-2150 Manual.qxd 10/20/03 9:33 AM Page 3
SPI-14/18-2150
Descriptions
400-2150MHz Satellite Inline Power Inserters
4
Rev. 06/03
www.picomacom.com
SPI-14/18-2150
400-2150MHz Satellite Inline Power Inserters
TruSpec power inserters supply constant DC voltage to C/Ku or DSS Satellite LNBs,
microwave down-converters and in-line amplifiers – Plug-in External UL Power Wall Adapter Included – Input Voltage 120VAC 60Hz 35W – Operating Frequency 400­2150MHz – 2 Independent Paths – Output Voltage Selection Switch 13-14/17-18 or 17-18/17-18 VDC 600mA – Insertion Loss 2dB ±1dB – Isolation 65dB
SPI-14/18-2150 Manual.qxd 10/20/03 9:33 AM Page 4
SPI-14/18-2150
Specifications
5
Rev. 06/03
www.picomacom.com
400-2150MHz Satellite Inline Power Inserters
Ordering Information
SPI-14/18-2150
SPI-14/18-2150 Manual.qxd 10/20/03 9:33 AM Page 5
SPI-14/18-2150
6
Rev. 06/03
www.picomacom.com
Operation and Controls
Front Panel
1. H-OUT (RF):
The Horizontal or Left Hand Circular Polarity (LHCP) is available at this F port.
2. V-OUT (RF):
The Ver tical or Right Hand Circular Polarity (RHCP) is available at this F port.
3. PWR TO H-LNB (17/18):
This port provides voltage (17/18vdc) to the LNB and serves as the horizontal or LHCP input.
4. PWR TO V-LNB (13/14):
This port provides voltage (13/14vdc) to the LNB and serves as the vertical or RHCP input. This port may also be configured to provide 17/18vdc.
5. Voltage Selection Switch:
This switch can be toggled to provide 13/14 or 17/18vdc at the “PWR TO V-LNB” port.
6. Wall Adaptor Jack:
This 3.5mm plug receptacle is provided for insertion of DC voltage via the AC wall adaptor.
1
2
3
4
5
6
SPI-14/18-2150 Manual.qxd 10/20/03 9:33 AM Page 6
SPI-14/18-2150
7
Rev. 06/03
www.picomacom.com
Installation Procedure
Installation
1. Connect the V-OUT and H-OUT to the appropriate polarity of the satellite IF distribution system.
2. Connect the PWR TO H-LNB and PWR TO V-LNB to the LNB.
3. Verify the voltage selector switch is in the correct position 13/14~17/18 for DBS operation or 17/18~17/18 for C/ku band operation.
4. Insert the 3.5mm power adaptor connector into the SPI-14/18-2150. Plug the AC wall adaptor into a polarized wall receptacle.
SPI-14/18-2150 Manual.qxd 10/20/03 9:34 AM Page 7
SPI-14/18-2150
8
Rev. 06/03
www.picomacom.com
Warranty
Limited Warranty
Pico Macom warrants to the original purchaser that all of its new products are of sound design, quality materials and workmanship at the time of manufacture
and will be free from related defects for one year from the original purchase date. Pico Macom will repair or, at its discretion, replace without cost to the original purchaser, the product which, upon inspection by Pico Macom, appears to be defective or not conforming to factory specifications. Pico Macom will cover the cost of parts, labor, and return freight from factory.
Five-Year Limited Warranty
Most products designated as “Headend Electronics” are further covered by an extended 4-year period beyond the expiration of the original 1-year warranty, for a full
5-year period. Qualified equipment requiring factory repair during the extended 4-year period is covered under our re-certification program. Re-certification fees under this program shall not to exceed 20% of the product’s List Price and whenever possible, Pico Macom will attempt to upgrade performance to the latest improved specification.
Warranty Limitations
This warranty excludes coverage of damage or inoperability resulting from (1) use or installation other than in strict accordance with Pico Macom’s written instruc-
tions, (2) disassembly or repair by someone other than Pico Macom or a Pico Macom authorized repair center, (3) misuse, misapplication or abuse, (4) alteration, (5) lack of reasonable care or (6) wind, ice, snow, rain, lightning, power surges, or any other weather conditions or acts of God. Pico Macom’s warranty with respect to third-party proprietary sub-assembly modules and/or private-label products are limited to the duration and terms of third-party vendors’ warranty. Pico Macom shall in no event and under no circumstances be liable or responsible for any consequential, indirect, incidental, punitive, direct or special damages based upon breach of warranty, breach of contract, negligence, strict tort liability or otherwise or any other legal theory, arising directly or indirectly from the sale, use, installa­tion or failure of any product acquired by buyer from Pico Macom. This limited warranty extends to the original purchaser. Pico Macom reserves the right to modify or discontinue this warranty at Pico Macom’s sole discretion without notification. No other warrantees are expressed or implied.
Uptime Loaner Program
Our Uptime loaner program is designed to provide domestic users of our headend products and commercial systems the best possible support and service. This
program is established to minimize downtime resulting from equipment failure in critical service situations. We offer this program free-of-charge (excluding freight) to qualified purchasers within the warranty period. The program provides a free equipment loan of like qualified equipment enabling seamless operation for the time required to repair and return the unit.
The process is simple. Call our Customer Service desk requesting a return-merchandise-authorization (RMA) number for the failed equipment and ask for a loaner unit. We will issue an invoice for the List Price of the loaner unit plus shipping costs. When you receive the loaner unit, pack the failed unit in the loaner unit’s box and ship it freight prepaid to Pico Macom for repair.When you receive the repaired unit, a new RMA number will be provided in the box. Carefully pack the loaner unit and affix the new RMA number on the box and ship it back to us for full credit excluding shipping costs.
To qualify for the program, you must have current open-terms with us and in good standing. We must receive your failed unit within one week after the loaner unit is shipped to you, and must likewise receive the loaner unit within one week after the repaired unit is shipped back to you. Daily rental fees not to exceed 10% of the equipment’s List Price will apply beyond one week after the loaner or repaired unit are shipped to you. Other limitations may apply, so please call us for addi­tional information on qualifying equipment and procedures. Pico Macom reserves the right to modify or discontinue the Uptime Loaner Program at any time, and at its sole discretion.
Damage or Shortage Claims
Our shipping staff carefully packs and ships your orders in compliance with common carriers’ requirements. Please make note of any obvious damage or shortage
on the freight bill or carrier’s receipt next to your signature. The carrier’s agent must too sign acknowledging the loss. Failure to do so may result in the carrier’s refusal to honor the claim. Please open your order immediately upon receipt to check for concealed damage and compare the packing list to the items shipped. If damaged, keep the original shipping cartons for possible inspection by the carrier.You must report claims for loss or damage within 3 days of delivery, while claims for erroneous charges or price corrections must be presented within 30 days of invoice date.
Returning Shipped Items
To return any shipped items, including those shipped for warranty repairs or credit, call our Customer Service desk to request a Return Merchandise Authorization
(RMA) number. Please reference the original invoice number and purchase date, and product serial number (if any). Be certain to mark the RMA number on the package boldly and legibly. Unless we specify a different carrier, please ship your returned items to us via UPS freight prepaid and fully insured. If returned for credit, we will promptly process your request upon receipt of your return order.
Our Return Policy: Your Satisfaction Guaranteed
Our goal is your complete satisfaction. If for any reason, our products were not quite what you anticipated, simply call your customer service rep and
we will be happy to assist you in replacing or returning the order.You may return current, non-discontinued items for full credit for up to 30 days from invoice date. Our requirements are simple: Excepting defective items, the products must be returned in their original packaging and in re-salable condition. Restocking fees may otherwise apply beyond this period or if products are not returned in their original condition. Please contact your customer service rep for more information.
SPI-14/18-2150 Manual.qxd 10/20/03 9:34 AM Page 8
Loading...