Pico Macom PIDA-1000, PIDA-750, PIDA-550 User Manual

HON-KWANG
AHEAD
PLUG IN CLASS 2 TRANSFORMER
AC ADAPTOR
LISTED
U
69N0
Model: MW57-02401250A
L
®
E97199
I/P: AC120V 60Hz MODEL NO: D12-10-03 O/P: 24V 1250mA
INPUT:120V 60Hz 25W OUTPUT: 26VAC 1.2A
PIDA
Pro Series
O
F
U
O
T
R
P
W
U
T
A
R
D
-
3
0
T
d
E
A
T
T
G
A
E
F
I
N
A
N
C
T
T
&
T
O
I
O
S
O
M
L
R
O
I
N
Y
N
F
P
I
S
O
M
E
E
U
W
T
M
P
A
A
R
T
D
H
S
L
O
P
E
T
D
W
IS
O
P
F
L
A
T
G
A
I
N
M
A
X
H
T
A
P
D
R
A
W
FO
E
Q
F
A
H
P
F
L
P
F
I
N
F
O
P
U
W
T
F
A
A
R
D
-
3
0
T
d
E
B
S
T
2
6
V
A
6
C
P
0
O
H
1
W
z
E
R
H
P
F
A
P
L
P
F
H
T
A
3
P
6
N
S
/
4
R
P
9
U
T
L
E
I
T
R
T
E
NTSC AUDIO/VIDEO
T
-
W
R
ID
I
A
B
Y
U
A
B
T
IO
R
O
N
A
A
D
M
B
A
P
L
N
IF
M
OD
EL
P
:
I
D
A
P
-
5
I
D
5
A
0
-
7
I
D
5
A
0
-
1
0
0
0
M
H
z
R
D
IE
R
B
S
T
G
A
I
N
M
R
A
E
X
T
P
U
A
R
T
N
H
BROADBAND DISTRIBUTION
AMPLIFIER
Installation
Operation
Manual
for PIDA-550, 750 and 1000
And
ECO 1769
PICO MACOM, INC.
12500 Foothill Blvd. • Lakeview Terrace, CA 91342 • (818) 897-0028 • (800) 421-6511 • FAX (818) 834-7197
SAFEGUARDS
Important Information
Product Inspection
Inspect the equipment for shipping damage. Should any damage be discovered, immediately file a claim with the carrier.
Important
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
REFER SEVICING TO QUALIFIED SERVICE PERSONNEL
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE
Safety Instructions
To insure proper installation and operation, take a moment to read this guide before proceeding with the installation. If you have any questions or comments about the PIDA amplifier, please contact your dealer or have him contact the PICO MACOM Service Center at the phone numbers on the bottom of the page.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE
THIS APPLIANCE TO RAIN OR MOISTURE. DO NOT OPEN THE CABINET, REFER SERVICING TO QUALIFIED PERSONNEL ONLY.
CAUTION: TO PREVENT ELECTRIC SHOCK DO NOT USE THIS (POLARIZED) PLUG
WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and mainte­nance (servicing) instructions in the literature accompanying the appliance.
ATTENCION : POUR PREVENIR LES CHOCS ELECTRIQUES, NE PAS UTILISER CETTE
FICHE POLARISEE AVEC UN PROLONGATEUR, UNE PRISE DE COURANT OU UNE AUTRE SORTIE DE COURANT, SAUF SI LES LAMES PEUVENT ETRE INSEREES A FOND SANS ENLAISSER AUCUNE PARTIE A DECOUVERT.
1. Read Instructions - All safety and operating instructions should be read before the appliance is operated.
2. Retain Instructions - The safety and operating instructions should be retained for future reference.
3. Heed Warnings - All warnings on the appliance should be adhered to.
4. Follow Instructions - All operating and user instructions should be followed.
5. Cleaning - Unplug this appliance from the wall outlet before cleaning. Use a damp cloth for cleaning. Do not use liquid cleaners or aerosol cleansers.
6. Do Not Use Attachments - not recommended by the manufacturer or they may cause hazards.
1
PICO MACOM, INC.
12500 Foothill Blvd. • Lakeview Terrace, CA 91342 • (818) 897-0028 • (800) 421-6511 • FAX (818) 834-7197
7. Water and Moisture - Do not use this product near water ­for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool - and the like.
8. Accessories - Do not place this product on an unstable cart, stand, tripod, bracket, or table. The product may fall, causing serious injury to a child or adult, and serious damage to the appliance.
9. Ventilation - This video product should never be placed near or over a radiator or heat register. This video product should not be placed in a built-in installation such as a bookcase or rack unless proper ventilation is provided or the manufacturer’s instructions have been adhered to. Any slots or opening in the cabinet are provided for ventilation. To ensure reliable opera­tion of the video product and to protect it from overheating, these openings must not be blocked or covered. The openings should never be blocked by placing the product on a bed, sofa, rug, or other similar surface.
SAFEGUARDS
Important Information
10. Grounding or Polarization - This video product is equipped with either a three prong plug for 120 Vac use. It is to be inserted into only the type of receptacle for which they specifi­cally designed . Do not cut off the round grounding pin in order to be able to fit into a two prong receptacle as this could cause injury and will void the warranty.
11. Power Sources - This product should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supplied to your home, consult your appliance dealer or local power company.
12. Power-cord Protection - Power-supply cords should be routed so they are not likely to be walked on or pinched by items placed upon or against them. Pay particular attention to cords and plugs, convenience receptacles, and the point where they exit from the appliance.
13. Lightning - For added protection for this product during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet.
14. Power Lines - An outside antenna system should not be located in the vicinity of overhead power lines, other electric light or power circuits, where it can fall into such power lines or circuits. When installing an outside antenna system, extreme care should be taken to keep from touching such power lines or circuits as contact with them may be fatal.
15. Overloading - Do not overload wall outlets and extension cords as this can result in risk of fire or electric shock.
16. Object and Liquid Entry - Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short-out parts that could result in a fire or electric shock. Never spill liquid of any kind on the product.
17. Servicing - Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.
18. Damage Requiring Service - Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions:
a. When the power-supply cord or plug is damaged. b. If liquid has been spilled, or objects have fallen into the
product.
c. If the product has been exposed to rain or water. d. If the product does not operate normally by following the
operating instruction. Adjust only those controls that are covered by the operating instructions. An improper adjustment may result in damage and will often require extensive work by a qualified technician to restore the product to its normal operation. e. If the product has been dropped or the cabinet has been damaged. f. When the product exhibits a distinct change in performance
- this indicates a need for service.
EXAMPLE OF ANTENNA GROUNDING ACCORDING TO
NATIONAL ELECTRICAL CODE INSTRUCTIONS CONTAINED
IN ARTICLE 810 - "RADIO AND TELEVISION
EQUIPMENT"
POWER LINES
LAM
PS
GROUND CLAMP
TO EXTERNAL ANTENNA TERMINALS OF PRODUCT
d
GROUND WIRE GROUND CLAMPS OPTIONAL ANTENNA GROUNDING ELECTRODE
DRIVEN 8 FEET (2.44M) INTO THE EARTH IF REQUIRED BY LOCAL CODES. SEE NEC SECTION 810 - 21(f).
STANDOFF
b
INSULATORS
MAST ANTENNA
LEAD-IN WIRE
ANTENNA DISCHARGE UNIT
c
SERVICE ENTRANCE EQUIPMENT
POWER SERVICE GROUNDING ELECTRODE SYSTEM (e.g. interior metal water pipe)
SERVICE ENTRANCE CONDUCTORS
G
ROUND C
BONDING JUMPER
19. Replacement Parts - When replacement parts are required, be sure the service technician has used replacement parts speci­fied by the manufacturer or have the same characteristics as the original parts. Unauthorized substitutes may result in fire, electric shock or other hazards.
20. Safety Check - Upon completion of any service or repairs to this product, ask the service technician to perform safety checks to determine that the product is in proper operating conditions.
21. Outdoor Antenna Grounding - Before attempting to install this product, be sure the antenna or cable system is grounded so as to provide some protection against voltage surges and built-up static charges. a. Use No.10 AWG (5.3mm ) copper, No.8 AWG (8.4mm (aluminum, No.7 AWG (10mm ) copper-clad steel or bronze wire or larger, as ground wire. b. Secure antenna lead-in and ground wires to house with stand­off insulators spaced from 4 feet (1.22m) to 6 feet (1.83m) apart. c. Mount antenna discharge unit as close as possible to where lead-in enters house. d. A driven rod may be used as the grounding electrode where other types of electrode systems do not exist. Refer to the National Electrical Code, ANSI/NFPA 70-1984 for information. e. Use jumper wire not smaller than No.6 AWG (13.3mm ) copper or equivalent, when a separate antenna grounding elec­trode is used.
NOTE TO THE CATV SYSTEM INSTALLER:
THIS REMINDER IS PROVIDED TO CALL THE CATV SYS­TEM INSTALLER’S ATTENTION TO ARTICLE 820 - 40 OF THE NEC THAT PROVIDES GUIDELINES FOR PROPER GROUND­ING AND, IN PARTICULAR, SPECIFIES THAT THE CABLE GROUND SHALL BE CONNECTED TO THE GROUNDING SYSTEM OF THE BUILDING, AS CLOSE TO THE POINT OF CABLE ENTRY AS PRACTICAL.
2
PICO MACOM, INC.
12500 Foothill Blvd. • Lakeview Terrace, CA 91342 • (818) 897-0028 • (800) 421-6511 • FAX (818) 834-7197
D E S C R I P T I O N S
and Specifications
Features
Several models available in 1000, 750 and 550MHz bandwidths
Built-in variable slope and gain controls for foward path
Built-in gain control for reverse path
Optional plug-in equalizers and attenuators
Dual push-pull hybrid modules for low distortion, high input and output capability
External U.L approved 26Vac power supply
Input and output test ports for monitoring signal levels without disturbing service.
Description
The PIDA series of broadband distribution amplifiers are high quality push-pull amplifiers producing signal with extremely low distortion and high output. These amplifiers are designed for RF distribution systems for hospitals, schools, apartment complexes, hotels and similar applications. It can also be used as a headend launch amplifier in conjunction with the PHC-12U headend combiner. The enclosure is made of aluminum to assure reliable heat sinking and corrosion resistance.
+
ATTENTION
GAIN & SLOPE FACTORY SET
TO MINIMUM
FOWARD
PATH
SLOPE
FLAT
+
GAIN
MAX
FOWARD PATH
EQ
+
+ +
OUTPUT
FORWARD
TWO-WA Y BROADBAND
DISTRIBUTION AMPLIFIER
MODEL:
PIDA-550 PIDA-750 PIDA-1000
HPF LPF
HPF LPF
FA FA
INPUT
FOWARD
-30dB TEST
PIDA
-30dB TEST
RETURN PATH
26VAC 1A
60Hz
POWER
GAIN
MAX
RETURN
PATH
FOWARD PATH
TILT
+
+
+
Specifications
Foward Path Return Path
Frequency Range: PIDA-1000: 50-1000MHz 5-36MHz
PIDA-750: 50-750MHz 5-36MHz PIDA-550: 50-550MHz 5-36MHz
Channel Loading: 110 3 Flatness: ±0.75dB ±0.5 ref to 1dB tilt Gain: 30dB 20dB Noise Figure (a): 8.5dB 6dB Output Level: +40dBmV +42dBmV Test Port Level: -30±2dB ------­Gain Control Range: 10dB 18dB Slope Control Range: 8dB ------­Composite Triple Beat-CTB (b): -53dB -60dB Composite Second Order-CSO (b): -56dB -60dB Cross Modulation-XMOD (b): -54dB -60dB Hum Modulation: -70dB -65dB Impedance-All Ports: 75 ohms 75 ohms Return Loss-Input and Output: 16dB 16dB Operating Temperature: -20 to +60 deg C ------­Power Supply (adapter): 26Vac, 60 ------­Size (approximate): 7.25 x 3.25 x 10.25 ------­Number of Hybrids: 2 ------­Hybrid type: Push-Pull -------
Notes:
a. measured at full gain with 0dB slope
3
b. at specified channel loading at rated output capacity
PICO MACOM, INC.
12500 Foothill Blvd. • Lakeview Terrace, CA 91342 • (818) 897-0028 • (800) 421-6511 • FAX (818) 834-7197
PCB Plug-In Module and Jumper Locations
REMOVE JUMPERS W6 AND W5 AND INSERT JUMPER BETWEEN THESE TWO POINTS FOR PASSIVE RETURN PATH
D E S C R I P T I O N S
RETURN PATH INPUT FOWARD PATH OUTPUT
-30dB OUTPUT TEST POINT
GAIN CONTROL (RETURN PATH)
W5
JUMPERS W5 AND W6 INSERTED FOR ACTIVE RETURN PATH
SLOPE CONTROL
(FOWARD PATH)
GAIN CONTROL (FOWARD PATH)
PLUG-IN LOCATION FOR ATTENUATOR* (FORWARD PATH)
PLUG-IN LOCATION FOR EQUALIZER* (FORWARD PATH)
FOWARD
ATTENUATOR
W10
W6
W8
EQUALIZER
W3
W2
PIDA 550/750/1000
PLUG-IN LOCATION FOR ATTENUATOR* (RETURN PATH)
-30dB INPUT TEST POINT
FOWARD PATH INPUT RETURN PATH OUTPUT
*NOTE:
PLUG-IN EQUALIZERS AND ATTENUATORS ARE OPTIONAL. IF PLUG-INS ARE TO BE USED REMOVE JUMPER WIRE AT APPROPRIATE LOCATION AND INSERT PLUG-IN.
PICO MACOM, INC.
4
12500 Foothill Blvd. • Lakeview Terrace, CA 91342 • (818) 897-0028 • (800) 421-6511 • FAX (818) 834-7197
D E S C R I P T I O N S
Block Diagram
RF OUTPUT
RETURN PATH INPUT
2
HYBRID AMP
FLAT
SLOPE CONTROL
CIRCUIT
FULL
GAIN CONTROL
CIRCUIT
HYBRID AMP
1
49 MHz
HPF
36 MHz
LPF
FULL
FREQUENCY OFFSETS - FCC (U.S.A.)
W3
TEST PORT
(-30dB)
ATT.
GAIN CONTROL
CIRCUIT
P4
P3
J3
PASSIVE RETURN
P2
P1
J2
J1
NOTES:
1. FOR PASSIVE RETURN, CONNECT J3 TO P1 AND P4.
2. FOR ACTIVE RETURN, CONNECT J1 TO P1 AND P2 ANDJ2 TO P3 AND P4
3. PLUG-IN EQUALIZERS AND ATTENUATORS ARE OPTIONAL. IF PLUG-INS ARE TO BE USED REMOVE JUMPER WIRE AT APPROPRIATE LOCATION AND INSERT PLUG-IN
5
PICO MACOM, INC.
W2
49 MHz
RF INPUT RETURN PATH OUTPUT
HPF
36 MHz
LPF
ATT.
W8
TEST PORT
(-30dB)
12500 Foothill Blvd. • Lakeview Terrace, CA 91342 • (818) 897-0028 • (800) 421-6511 • FAX (818) 834-7197
INSTALLATION
Power Adaptor Hook-Up
POWER STRIP TERMINAL FOR 26VAC, 1A ADAPTOR
HON-KWANG
AHEAD
PLUG IN CLASS 2 TRANSFORMER
AC ADAPTOR
Model: MW57-02401250A I/P: AC120V 60Hz
MODEL NO: D12-10-03 O/P: 24V 1250mA
INPUT:120V 60Hz 25W OUTPUT: 26VDC 1.0A
LISTED
U
69N0
L
®
E97199
PICO MACOM, INC.
6
12500 Foothill Blvd. • Lakeview Terrace, CA 91342 • (818) 897-0028 • (800) 421-6511 • FAX (818) 834-7197
INSTALLATION
Distribution
The output levels of the modulator should be the same as the output of the off-air strip amplifiers. The M860
modulators are usually combined with either the SP860 signal processor, LBS/MBS/FMS/UBS series strip amplifiers. Two methods are suggested to combine strip amplifier, modulator and processor outputs which are then amplified with the PIDA distribution amplifier serving as a launchamp.
The PHC-12U twelve channel passive headend combiner consists of two rows of directional couplers
combined by a hybrid splitter. The directional coupler combining provides high isolation (40 dB) between the inputs. Normally, the odd channels are combined on one row while even channels are combined on the other row of directional couplers. The combiner loss is 16 dB per channel.
V A
RF
IN
RF
IN
+10dBmV
+14dBmV +10dBmV
M860
SP860
*BS
+52dBmV
+52dBmV
+52dBmV
Ch. 2
PHC-12U
-16dB
Ch. 3
Ch. 4
+36dBmV
6dB PAD
ATTENUA TOR P AD
PIDA-*
+60dBmV
Another method of combining signals uses three hybrid splitters per headend rack. The odd channels are
combined in one splitter, the even channels in another splitter and the two splitters are combined to a single output with a third splitter. Each rack is then combined with a final splitter prior to the PIDA amplifier.
NOTE : * Denotes either LBS, MBS, HBS or FMS model numbers.
V A
M860S
+60dBmV
Ch. 2
+45dBmV
RF
+10dBmV
IN
+14dBmV
RF
+10dBmV
IN
*PIDA-550, 750, 1000
7
PICO MACOM, INC.
Ch. 4
SP860
*BS
+52dBmV
+52dBmV
EVEN CHANNELS
Ch. 3
ODD CHANNELS
+45dBmV
+38dBmV +60dBmv
8dB PAD
ATTENUA TOR P AD
PIDA-*
12500 Foothill Blvd. • Lakeview Terrace, CA 91342 • (818) 897-0028 • (800) 421-6511 • FAX (818) 834-7197
16
W A R R A N T Y
Five Y ear Limited Warranty*
ico Macom, Inc. war­rants to the original purchaser this prod­uct shall be free of
P
with only the limitations or exclusions set out below.
During the warranty period Pico Macom, Inc. or an authorized Pico Macom service facility will provide, free of charge, the parts and labor necessary to correct defects in mate­rial and workmanship.
defects in material and craftsmanship
Warranty Duration
This warranty shall terminate five years* from the original date of pur­chase of the product or at a time the product is:
1. Misused or damaged due to
neglect or improper installation
2. Modified
3. Repaired by someone other
than the warrantor
4. Sold by the original purchaser
Statement of Remedy
To obtain such a warranty service,
contact the salesperson where the prod­uct was obtained or contact Pico Macom, Inc at the address listed at bottom of page . You will be issued a Return Authoriza­tion (RA) number which will be used to track your product. Be prepared to provide:
1. The model number and channel number of the product
2. The date of purchase
3. A specific identification of the
problem Deliver the products to Pico Macom, Inc. or ship the products in the original packing material at the address at the bottom of the page. Include satisfactory evidence of the date of purchase.
Products will not be accepted by Pico Macom, Inc. without the RA number clearly indicated on the shipping label.
The foregoing constitutes the Pico Macom, Inc. entire obligation with re­spect to this product and the original purchaser and any user or owner shall have no other remedy and no claim for
incidental or consequential damages.
This warranty gives you specific le­gal rights, and you also have rights which vary from state to state. (U.S.A.)
*One year limited warranty on product sold outside the U.S.A.
PICO MACOM, INC.
8
12500 Foothill Blvd. • Lakeview Terrace, CA 91342 • (818) 897-0028 • (800) 421-6511 • FAX (818) 834-7197
NOTES
PICO MACOM, INC.
12500 Foothill Blvd. • Lakeview Terrace, CA 91342 • (818) 897-0028 • (800) 421-6511 • FAX (818) 834-7197
NOTES
PICO MACOM, INC.
12500 Foothill Blvd. • Lakeview Terrace, CA 91342 • (818) 897-0028 • (800) 421-6511 • FAX (818) 834-7197
PICO MACOM, INC.
12500 Foothill Blvd. • Lakeview Terrace, CA 91342 • (818) 897-0028 • (800) 421-6511 • FAX (818) 834-7197
Loading...