Piazzetta 600HT, 610 HT, 655HT, 650HT Installation, Use And Maintenance Instructions

The instruction booklet is an integral part of the product.
English
installation, use and
maintenance instructions
Riverside, Goods Road, Belper, Derbyshire. DE56 1 UU Tel. 01773 820940 • Fax 01773 820477 e-mail: info@robeys.co.uk • web site: www.robeys.co.uk
600HT - 610 HT - 650HT - 655HT
English
2
H07024510 / DT2000575 - Rev. 00
SUPPLEMENTARY INSTALLATION INSTRUCTIONS FOR THE UK MARKET
TO BE READ IN CONJUNCTION WITH THOSE IN THE INSTRUCTION BOOKLET
Please note that it is a legal requirement under England and Wales Building Regulations that the installation of the stove is either carried out under Local Authority Building Control approval or is installed by a Competent Person registered with a Government approved Competent Persons Scheme. HETAS Ltd operate such a Scheme and a listing of their Registered Competent Persons can be found on their website at www.hetas.co.uk.
HEALTH AND SAFETY PRECAUTIONS
Special care must be taken when installing the stove such that the requirements of the Health and Safety at Work Act are met.
Handling
Adequate facilities must be available for loading, unloading and site handling. Ensure compliance with the “Manual Handling Operations 1992 Regulations” as amended. Mechanical handling equipment may be required.
Fire Cement
Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case of contact wash immediately with plenty of water.
Asbestos
This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective equipment.
Metal Parts
When installing or servicing this stove care should be taken to avoid the possibility of personal injury. Wear suitable gloves
STOVE PERFORMANCE
In the UK the stove has been approved by HETAS Ltd as an intermittent operating appliance for burning wood logs only.
It should be noted that it is an offence to burn wood logs in this stove if it is installed within a Smoke Control Area in the UK.
READ THE INSTRUCTION BOOKLET AND THESE SUPPLEMENTARY INSTRUCTIONS
CAREFULLY BEFORE INSTALLATION
These instructions together with those in the instruction booklet cover the basic principles to ensure the satisfactory installation of the stove, although detail may need slight modification to suit particular local site conditions.
In all cases the installation must comply with current Building Regulations, Local Authority Byelaws and other specifications or regulations as they affect the installation of the stove. It should be noted that the Building Regulations requirements may be met by adopting the relevant recommendations given in British Standards BS 8303, BS 6461 and BS 7566 as an alternative means to achieve an equivalent level of performance to that obtained following the guidance given in Approved Document J.
English
3
H07024510 / DT2000575 - Rev. 00
PREPARATORY WORK AND SAFETY CHECKS
IMPORTANT WARNING
This stove must not be installed into a chimney that serves any other heating appliance.
There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit fumes into the room.
Chimney
In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate draught of approximately 15 Pa so as to clear the products of combustion and prevent smoke problems into the room.
NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the top of the chimney should be satisfactory. Alternatively the calculation procedure given in BS 5854:1980 may be used as the basis for deciding whether a particular chimney design will provide sufficient draught.
The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regulations Approved Document J.
If installation is into an existing chimney then it must be sound and have no cracks or other faults which might allow fumes into the house. Older properties, especially, may have chimney faults or the cross section may be too large i.e. more than 230 mm x 230 mm. Remedial action should be taken, if required, seeking expert advice, if necessary. If it is found necessary to line the chimney then a flue liner suitable for solid fuel must be used in accordance with Building Regulations Approved Document J.
Any existing chimney must be clear of obstruction and have been swept clean immediately before installation of the stove. If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and the open fire.
If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations Approved Document J or a twin walled insulated stainless steel flue to BS EN 1856 can be used. These chimneys must be fitted in accordance with the manufacturer’s instructions and Building Regulations.
A single wall metal fluepipe is suitable for connecting the stove to the chimney but is not suitable for using for the complete chimney. The chimney and connecting fluepipe must have a minimum diameter of 150 mm and its dimension should be not less than the size of the outlet socket of the stove.
Any bend in the chimney or connecting fluepipe should not exceed 45°. 90° bends should not be used.
Combustible material should not be located where the heat dissipating through the walls of fireboxes or flues could ignite it. Therefore when installing the stove in the presence of combustible materials due account must be taken of the guidance on the separation of combustible material given in Building Regulations Approved Document J and also in these stove instructions.
If it is found that there is excessive draught in the chimney then either an adjustable flue damper or alternatively a draught stabiliser should be fitted. The adjustable flue damper should not close off the flue entirely but should in its closed position leave a minimum continuous opening free area of at least 20 % of the total cross sectional area of the flue or fluepipe.
Adequate provision e.g. easily accessible soot door or access doors, must be provided for sweeping the chimney and connecting fluepipe, also to permit visual checks on the integrity of the flue when the appliance is serviced.
English
4
H07024510 / DT2000575 - Rev. 00
Hearth
T
he hearth should be able to accommodate the weight of the stove and its chimney if the chimney is not
independently supported. The weight of the stove is indicated in the brochure.
The stove should always be installed on a non-combustible hearth of a size and construction that is in accordance with the provisions of the current Building Regulations Approved Document J.
The clearance distances to combustible material beneath, surrounding or upon the hearth and walls adjacent to the hearth should comply with the guidance on the separation of combustible material given in Building Regulations Approved Document J and also in these stove instructions.
If the stove is to be installed on a wooden floor, it must be covered with a non-combustible material at least 12mm thick, in accordance with Building Regulations Approved Document J, to a distance of 30 cm in front of the stove and 15 cm to each side measuring from the door of the combustion chamber.
Combustion air supply
In order for the stove to perform efficiently and safely there should be an adequate air supply into the room in which the stove is installed to provide combustion air. This is particularly necessary if the room is double-glazed or a flue draught stabiliser is operating in the same room as the appliance. It may be necessary to increase the air vent size in property with low air permeability [5.0 m
3
/(h.m2)] The provision of air supply to the stove must be in accordance with current Building RegulationsApproved Document J. An opening window is not appropriate for this purpose.
Connection to chimney
All the stoves have a rear and/or top flue gas connector that allows connection to either a masonry chimney or a prefabricated factory made insulated metal chimney in accordance with the instructions for the appliance given in the instruction booklet.
Commissioning and handover
Ensure loose parts are fitted in accordance with the instructions given in the instruction booklet.
On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out, when a small fire may be lit and checked to ensure the smoke and fumes are taken from the stove up the chimney and emitted safely to atmosphere. Do not run at full output for at least 24 hours.
On completion of the installation and commissioning ensure that the operating instructions for the stove are left with the customer. Ensure to advise the customer on the correct use of the appliance with the fuels likely to be used on the stove and warn them to use only the recommended fuels for the stove.
Advise the user what to do should smoke or fumes be emitted from the stove. The customer should be warned to use a fireguard to BS 6539 in the presence of children, aged and/or infirm persons. Make provision for securing a suitable guard where applicable.
Carbon Monoxide Alarm
A carbon monoxide alarm complying with BS EN 50291 must be fitted in the same room as the appliance in accordance with the current Building Regulations Part J. It should be positioned on the ceiling at least 300mm from any wall or, if it is located on a wall, as high up as possible (above any doors and windows) but not within 150mm of the ceiling. The alarm should also be between 1m and 3m horizontally from the appliance.
English
5
H07024510 / DT2000575 - Rev. 00
SUPPLEMENTARY USER OPERATING INSTRUCTIONS
TO BE READ IN CONJUNCTION WITH THOSE IN THE INSTRUCTION BOOKLET
WARNING NOTE
Properly installed, operated and maintained this stove will not emit fumes into the dwelling. Occasional fumes from de-ashing and re-fuelling may occur. However, persistent fume emission is potentially dangerous and must not be tolerated. If fume emission does persist, then the following immediate action should be taken: -
(a) Open doors and windows to ventilate room
(b) Let the fire out or eject and safely dispose of fuel from the appliance
(c) Check for flue or chimney blockage and clean if required
(d) Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected.
If necessary seek expert advice.
The most common cause of fume emission is flueway or chimney blockage. For your own safety these must be kept clean at all times.
IMPORTANT NOTES
General
Before lighting the stove check with the installer that the installation work and commissioning checks described in the installation instructions have been carried out correctly and that the chimney has been swept clean, is sound and free from any obstructions. As part of the stoves’ commissioning and handover the installer should have shown you how to operate the stove correctly.
Use of fireguard
When using the stove in situations where children, aged and/or infirm persons are present a fireguard must be used to prevent accidental contact with the stove. The fireguard should be manufactured in accordance with BS 8423:2002.
If the fire is left unattended a spark guard to BS3248, specification for spark guards for use with solid fuel appliances should be used.
Chimney cleaning
The chimney should be swept at least once a year for smokeless fuels and a minimum of twice a year for wood and other fuels. It is important that the flue connection and chimney are swept prior to lighting up after a prolonged shutdown period.
If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and the open fire.
In situations where it is not possible to sweep through the stove the installer will have provided alternative means, such as a soot door. After sweeping the chimney the stove flue outlet and the flue pipe connecting the stove to the chimney must be cleaned with a flue brush.
READ THE INSTRUCTION BOOKLET AND THESE INSTRUCTIONS CAREFULLY
BEFORE USING THE STOVE
English
6
H07024510 / DT2000575 - Rev. 00
Extractor fan
T
here must not be an extractor fan fitted in the same room as the stove as this can cause the stove to
emit smoke and fumes into the room.
Aerosol sprays
Do not use an aerosol spray on or near the stove when it is alight.
Use of operating tools
Always use the operating tools provided when handling parts likely to be hot when the stove is in use.
Chimney Fires
If the chimney is thoroughly and regularly swept, chimney fires should not occur. However, if a chimney fire does occur turn the air control setting to the minimum, and tightly close the doors of the stove. This should cause the chimney fire to go out in which case the control should be kept at the minimum setting until the fire in the stove has gone out. The chimney and flueways should then be cleaned. If the chimney fire does not go out when the above action is taken then the fire brigade should be called immediately.
After a chimney fire the chimney should be carefully examined for any damage. Expert advice should be sought if necessary
Permanent air vent
The stove requires a permanent and adequate air supply in order for it to operate safely and efficiently. In accordance with current Building Regulations the installer may have fitted a permanent air supply vent into the room in which the stove is installed to provide combustion air. This air vent should not under any circumstances be shut off or sealed.
HETAS Ltd Approval Please note that HETAS Approval only covers the use of wood on the stove and approval does not cover the use of other fuels either alone or mixed with other fuels, nor does it cover instructions for the use of other fuels.
USER OPERATING INSTRUCTIONS - WOOD
The instructions detailed in the section / in the instruction booklet should be followed.
Door operation
Describe door operation and use of the tool to open and close the doors, if appropriate.
Lighting of fire
Place some firelighters or paper and dry kindling wood on the grate and cover with a small amount of fuel. Set air controls to maximum and set light to firelighters or paper. Close the doors and allow fire to burn until fuel is well alight then load with more fuel and adjust air controls to the required level of heat output.
Before relighting the fire clean the firebed of excess ash and clinker and empty the ashpan.
Refuelling
Keep the firebox well filled (the fuel may be sloped up from the front firebars), but do not allow fuel to spill over the top of the front fire bars. Take care that fuel does not project over the front fire bars or damage to the glass may be caused when the doors are closed
English
7
H07024510 / DT2000575 - Rev. 00
Flueway cleaning
I
t is important that the baffle plate and all the stove flueways are kept clean. When burning smokeless fuels they should be cleaned at least monthly. When burning other fuels they should be cleaned at least once a week, and more frequently if necessary.
Remove any sooty deposits from the baffle plate.
More soot will be deposited on the baffle plate and in the flueways if the stove is run at low levels for long periods. If this is the case then more frequent cleaning will be necessary.
Cleaning and maintenance
The instructions detailed in the section “Maintenance” in the instruction booklet should be followed.
Trouble shooting
The instructions detailed in the relevant section in the instruction booklet should be followed together with the following additional items:
1. Fire Will Not Burn
Check that: a)the air inlet is not obstructed in any way, b)that chimneys and flueways are clear, c) that a suitable fuel is being used, d)that there is an adequate air supply into the room, e)that an extractor fan is not fitted in the same room as the fire.
2. Fire Blazing Out Of Control
Check that: a)the doors are tightly closed, b)the air control is turned down to the minimum setting, c) the air inlet damper is closed and that it is not prevented from closing completely by a piece of ash, d)a suitable fuel is being used, e) the door seals are in good condition.
DT2011502-00
Registered Office: Robeys Ltd, Goods Road, Belper Derbyshire DE56 1UU
Tel +44(0)1773 820940 Fax +44(0)1773 820477 Email info@robeys.co.uk www.robeys.co.uk
Company No. 5741182
Director: Mark Robey Company Secretary: Sharon Robey
English
8
H07024510 / DT2000575 - Rev. 00
Dear Customer, Thank you for having chosen one of our products, which is the result of years of experience and continuous research aimed at making a superior product in terms of safety, reliability and performance. T
his booklet contains information and advice for safe and efficient use of your product.
D
T2010001-01
See the guarantee certificate enclosed with the product for the terms, limitations and exclusions.
In line with its policy of constant product improvement and renewal, the manufacturer may make changes without notice.
This document is the property of Gruppo Piazzetta S.p.A.; no part of it may be disclosed to third parties without the written permission of Gruppo Piazzetta S.p.A. All rights reserved by Gruppo Piazzetta S.p.A..
• This instruction booklet has been prepared by the manufacturer
and is an integral part of the product. In the event of sale or relocation of the product make sure this booklet accompanies it, since the information contained in it is addressed to the purchaser and to anyone involved in the installation, use and maintenance of the product.
• Read the instructions and the technical information contained in
this booklet carefully before proceeding with installation, use or any repairs.
• The observance of the instructions and technical information in
this instruction booklet guarantees the safety of persons and property; it also ensures more efficient operation and an increased lifespan.
• Gruppo Piazzetta S.p.A. cannot be held responsible for damage or
injury due to failure to comply with the instructions for installation, use and maintenance given in this booklet, or due to unauthorised alterations or to the use of other than original spare parts.
• Appliance installation and use must conform with the
manufacturer’s instructions as well as with European and national legislation and local regulations.
• The wall against which the product is to be placed must not be of
wood or any other flammable material. For correct installation it is also important to maintain safety distances (refer to the section entitled “MINIMUM SAFETY DISTANCES”).
• Prior to completing installation of the surround, light the stove and when it has heated up check that the grate and that the flue connection is correct.
• Check that the floor where the product is to be installed is perfectly level.
• Do not fix the heater unit in any way whatsoever, but simply place it next to the surround.
• When handling the steel parts of the surround or the ceramic parts it is advisable to use clean cotton gloves to avoid leaving fingerprints that are difficult to remove at first time of cleaning
• The firebox must be assembled by two persons.
• This appliance has been designed solely for heating. It is not recommended for cooking foods.
• Stop using the product in the event of fault or malfunctioning.
• The product you have purchased may differ slightly from the one illustrated in this booklet since the pictures are only given as an indication and not an exact portrayal.
UNI EN 832 . . . . . . . . . . . . . . . . . . . . . . . .Thermal performance of buildings - Calculation of energy use for heating
UNI EN 13229 . . . . . . . . . . . . . . . . . . . . . .Inset appliances including open fires fired by solid fuels - Requirements and test methods
UNI 10683:2005 . . . . . . . . . . . . . . . . . . . . .Heating appliances fired by wood or other solid biofuels - Installation requirements
UNI EN 13384 . . . . . . . . . . . . . . . . . . . . . .Chimneys - Thermal and fluid dynamic calculation methods
UNI 7129 . . . . . . . . . . . . . . . . . . . . . . . . . .Gas plants for domestic use fed by network distribution
UNI 10847 . . . . . . . . . . . . . . . . . . . . . . . . .Chimneys for generators feeded with liquid and solid flues - Maintenance and inspection
EN 1856-1 . . . . . . . . . . . . . . . . . . . . . . . . .Chimneys - Requirements for metal chimneys - Part 1: System chimney products
EN 1856-2 . . . . . . . . . . . . . . . . . . . . . . . . .Chimneys - Requirements for metal chimneys - Part 2: Metal liners and connecting flue pipes
UNI EN 1443 . . . . . . . . . . . . . . . . . . . . . . .Chimneys – General requirements
DIN 18 895 . . . . . . . . . . . . . . . . . . . . . . . . .Fireboxes
DIN 51731 class of measurement HP2 . .Fuels
IMPORTANT INFORMATION
D
T2010139-00
REFERENCE STANDARDS
DT2010140-02
English
9
H07024510 / DT2000575 - Rev. 00
INDEX
DT2010187-01
This booklet code H07024510 / DT2000575 - Rev. 00 - (06/2010) comprises 40 pages.
S
ECTION TITLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PAGE
1
.0 GENERAL RULES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
1.1 SINGLE FLUEWAY OR CHIMNEY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
1.2 SOOT INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
1.3 CHIMNEY STACK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
1.4 PERMANENT VENTILATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
1.5 INSTALLATION ENVIRONMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
1.6 CAPACITY LOAD OF THE FLOOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
1
.7 HEATING CAPACITY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
1.8 METHOD OF HEAT DIFFUSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
1.9 SUITABLE HEAT INSULATING MATERIALS . . . . . . . . . . . . . . . . . . . . . . . .16
1.10 MINIMUM SAFETY DISTANCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
1.11 CONNECTION TO THE FLUEWAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
1.12 LINING WALL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
1.13 HOOK GRILLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
1.14 WOOD MANTEL PROTECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
1.15 ELECTRIC POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
1.16 PREVENTION OF DOMESTIC FIRE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
2.0 TECHNICAL DATA AND SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . .20
2.1 DESCRIPTION OF THE APPLIANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
2.2 ACCESSORIES AND EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
2.3 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
2.4 PRODUCT IDENTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
2.5 TECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
2.6 FIREBOX DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
3.0 PREPARATION FOR INSTALLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
4.0 INSTALLATION OF THE SMOKE DAMPER . . . . . . . . . . . . . . . . . . . . . . . .26
5.0 USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
5.1 FUEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
5.2 SMOKE DAMPER REGULATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
5.3 COMBUSTION AIR REGULATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
3.4 LIGHTING FOR THE FIRST TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
5.5 LIGHTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
5.6 OPENING THE DOOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
5.7 NIGHTTIME OPERATION AT MINIMUM . . . . . . . . . . . . . . . . . . . . . . . . . .30
5.8 OPERATION UNDER ADVERSE WEATHER CONDITIONS . . . . . . . . . . . . .31
5.9 OVERHEATING AND EXTINGUISHING . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
6.0 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
6.1 PERIODIC CECKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
6.2 CLEANING THE CERAMIC CLADDING . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
6.3 CLEANING THE STEEL PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
6.4 CLEANING THE PAINTED METAL PARTS . . . . . . . . . . . . . . . . . . . . . . . . .32
6.5 CLEANING THE GLASS (DAILY) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
6.6 CLEANING THE GRATE AND THE ASH TRAY . . . . . . . . . . . . . . . . . . . . . .33
6.7 DISPOSAL OF ASHES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
6.8 CLEANING ALUKER
®
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
6.9 REMOVING THE SMOKE BAFFLE PLATES . . . . . . . . . . . . . . . . . . . . . . . .34
6.10 CLEANING THE FAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
6.11 SHUTTING DOWN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
6.12 CLOSING DOOR SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
5.0 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
DECLARATION OF CONFORMITY STOVE 600 HT . . . . . . . . . . . . . . . . . . .37
DECLARATION OF CONFORMITY STOVE 610 HT/B . . . . . . . . . . . . . . . . .38
DECLARATION OF CONFORMITY STOVE 650 HT - 655T HT - 655E HT . .39
English
10
H07024510 / DT2000575 - Rev. 00
1.0 GENERAL RULES
DT2012089-00
Before proceeding with installation, choose the most suitable position for your firebox according to the indications given in the paragraph “MINIMUM SAFETY DISTANCES” and to all the indications below.
DT2033014-00
CHIMNEY POT
FLUEWAY
CONNECTION TO FLUE
INSPECTION SOOT DOOR
MINIMUM SAFETY DISTANCES
FRESH AIR INTAKE
POWER SWITCH
POWER SUPPLY
CHECK FLOOR FOR LOAD BEARING CAPACITY
MULTIFUOCO VENTILATION SYSTEM
CONTROL FOR FLUE DAMPER. NOTE, CAN BE ON SIDE
HOOD GRILL
LINING WALL
PROTECTION FOR ORNAMENTAL LEDGE
FIXED AIR OUTLET
MINIMUM SAFETY DISTANCES
F
ig. 1
English
11
H07024510 / DT2000575 - Rev. 00
DT2012124-00
1.1 SINGLE FLUEWAY OR CHIMNEY
Every appliance must have a vertical flue pipe operating by natural
draught to discharge the combustion gases outdoors.
T
he flue must:
- comply with regulations in force in the place of installation of the appliance;
- be sealed to the products of combustion, waterproof, suitably insulated, made with materials resistant to the corrosion of the g
ases and to stress;
- be connected to just one stove, firebox or extraction hood;
- be properly sized, with constant free internal section, equal to or greater than the diameter of the flue pipe of the stove and at least
3.5 m in length;
- be mainly in a vertical position with a deflection from the axis of no more than 45° (Fig. 2);
- be at a suitable distance from combustible or flammable materials, ensured by an air gap or suitable insulating material;
- be of uniform internal section, preferably round. Square or rectangular sections must have rounded corners with a radius of at least 20mm and a maximum ratio between the sides of 1.5 (Fig. 3-4-5);
- the walls must be smooth if possible and without narrowing. Bends must be regular and without discontinuity (Fig. 6).
It is forbidden to connect any other appliance to the flue either permanently or temporarily.
It is forbidden to pass other air ducts or service pipes inside the flue pipe, however large it is.
If the flue pipe is an incorrect size or installed other than in compliance with the above instructions, Gruppo Piazzetta S.p.A. cannot be held liable for malfunctioning of the product, damage to property or injury to persons or animals.
DT2010031-01
1.2 SOOT INSPECTION
We recommend that the flue must have a chamber for collecting solid matter and any condensate located below the connection and which may be easily inspected by means of an airtight door. (Fig.1)
D
T2030258-00
DT2030050-00
Fig. 2
Fig. 3
MAX 45°
NO
X
MINIMUM 3,5 M
Ø
DT2030188-00
Fig. 4
R
(
min
.
2
0
)
D
epos
i
t of c
reos
ot
e
DT2030189-00
Fig. 5
P
R (m
in. 20)
L (<_ 1,5 x P)
Deposit of creosote
DT2030190-00
Fig. 6
NO
English
12
H07024510 / DT2000575 - Rev. 00
The flue must be fitted at the top with a flue terminal designed to aid dispersion of the products of combustion in the atmosphere.
T
he flue terminal must comply with the following requirements:
- it must have an internal section and shape the same as the flue;
- it must have a useful outlet section of not less than twice that of the flue;
- the part of the flue that emerges from the roof or remains in contact w
ith the outside (e.g. in the case of an open loft), must be covered with brick or tile elements and well insulated. It must be built in such a way as to prevent the penetration of rain, snow and foreign matter into the flue and to ensure that in the event of winds from all directions and angle, discharge of the combustion products is assured (flue terminal with down-draught cowl);
- any buildings or other obstacles that are higher than the flue terminal must not be too close to the actual terminal Fig. 9;
- the flue terminal must be positioned in such a way as to ensure adequate dispersion and dilution of the angle of the roof and position see Fig. 10.
Clearances to easily ignited roof coverings (e.g. thatch) need to be increased in accordance with the building regulations part J.
6
-8 m
A
B*
*B free area is twice that of A
A
B
B
F
E
C
A
G
D
B
The illustration and table identify the minimum requirements as dictated by Building Regulations
CHIMNEY TERMINATION
Any adjacent building structure whether connected or not
N.B. All dimensions relate to the bottom edge of the terminal opening
Fig. 7 Fig. 8
F
ig. 9
Fig. 10
DT2030051-00
D
T2030052-00
DT2011502-00
DT2030191-00
1.3 CHIMNEY STACK
DT2012091-00
Dimension Minimum distance measured from the top of the chimney construction, excluding any pot or terminal
A
2, 3 metres horizontally clear of the roof surface, eg. if the roof pitch is 45°, then the chimney should project 2, 3 metres above it.
B 1 metre, provided A is satisfied, or 600 mm above the ridge if G is less than 600 mm.
C
1 metre above the top of any flat roof, and the top of any openable root light, dormer window or ventilator, etc., if it is located within 2, 3 metres.
D/E If D is less than 2, 3 metres, E shall be not less than 600 mm.
F 600 mm above the ridge. G Edge of chimney to roof ridge.
English
13
H07024510 / DT2000575 - Rev. 00
To ensure trouble-free operation the stove/firebox must have the necessary air available for combustion and this is provided through the permanent air vent.
The permanent air vent must:
- have a total free cross section at least equal to the size given in the
paragraph “TECHNICAL DATA”;
- be protected by a grille or suitable guard provided it does not
r
educe the minimum recommended section;
- be in a position whereby it cannot be obstructed.
The airflow necessary for the fire may be obtained in different ways:
- through a permanent air vent direct into the room of installation;
- with ducting through pipes direct to the room of installation,
increasing the recommended minimum free cross section by at least 15%;
- from an adjacent room to the place of installation provided this air
flows freely through permanent apertures communicating with the outside.
If the appliance is being fitted within an existing firebox recess, specialist advice should be sought before fitting any permanent ventilation within this area.
The adjacent room from which air is taken must not have a low pressure compared to the exterior due to a counter draught caused by the presence in that room of another appliance in use or of a suction device. The permanent apertures in the adjacent room must comply with the requirements given above.
Combustion air must not be taken from adjacent rooms used as a garage or a combustible materials store or for activities posing a fire hazard.
The air supply must comply with the current copy of the Building Regulations Approved Document J.
1.4 PERMANENT VENTILATION
DT2012090-00
Fig. 12
D
T2030260-01
Permanent air vent
Canopy grille
Fig. 11
D
T2030259-01
Fig. 13
DT2030261-01
English
14
H07024510 / DT2000575 - Rev. 00
DT2010033-01
1.5 INSTALLATION ENVIRONMENT
The appliance should be installed in a location which allows safe and convenient use as well as easy maintenance. If the product being installed requires an electrical socket, the room must also be provided with an earthed power supply in accordance with current regulations.
T
he room where the appliance is to be installed must comply with the following requirements:
they must not be used as a garage, store for combustible material or for activities with a risk of fire.
They must not be in a vacuum in relation to the outside environment due to the effect of contrary draught caused by the presence i
n the room where the firebox is installed of another appliance or an extractor device.
Do not use two stoves, a firebox and a stove, a stove and a wood-fired cooking range, etc. in the same environment, since the draught of one could affect the draught of the other.
• Recirculation type cooker hoods without an extractor fan may only be used in kitchens.
• Gas appliances of type C are allowed (refer to current legislation and regulations in the place of installation)
Gas appliances of type B are not allowed (refer to current legislation and regulations in the place of installation)
The stove or firebox must not be fitted where there are collective type ventilation ducts with or without extractor fan, other devices or other appliances such as: forced ventilation systems or other heating systems using ventilation to change the air. Such systems could cause a vacuum in the environment of installation even if installed in adjoining or communicating rooms.
The stove or firebox must not be used: in stairwells except in buildings with no more than two apartments; in corridors for common use; in bedrooms; in bathrooms or shower-rooms.
D
T2010171-00
1.6 CAPACITY LOAD OF THE FLOOR
Check the load-bearing capacity of the floor by adding together: the weight of the protections (lining walls), insulating materials, surround (given in the surround instruction booklet) and the stove (given in the paragraph “TECHNICAL DATA”). If the floor has an unsuitable load-bearing capacity, take adequate countermeasures.
D
T2010130-01
1.7 HEATING CAPACITY
Check the heating capacity of the appliance by comparing the rated power given in the paragraph
“TECHNICAL DATA”
with the power required by the environment to be heated. The energy requirement may be calculated approximately by multiplying the square metres of area by the height of the ceiling; the result is then multiplied by a coefficient, which depends on the degree of insulation of the building, that is, on internal and external factors of the dwelling: a) Internal factors: type of window and door frames, thickness of the insulation and walls, type of building materials, presence of stairwells,
walls with extensive glazing, high ceilings, position of the rooms to be heated in relation to other adjacent heated or unheated rooms, …
b) External factors: geographical position, average outdoor temperature, exposure, wind speed, latitude, altitude, …
Example of approximate calculation of the energy requirement to heat a fixed volume to 18/20° C:
The coefficient that is normally used is determined according to the real conditions as they occur case by case.
- From 0.04 to 0.05 kW per cubic metre in a well insulated environment
- From 0.05 to 0.06 kW per cubic metre in a poorly insulated environment
3 rooms measuring 20m2 X (H ceiling) 2.7m = 162 m3(volume)
In an environment with a good degree of insulation, an average value (coefficient) of 0.045 kW may be taken
162 (volume) X 0.045 (kW) = 7.3 kW necessary (6300 kcal/h)
Conversion 1kW = 860 kcal/h
Consult a heating technician or engineer for a correct check and calculation of the requirement of the environments to be heated (see “REFERENCE STANDARDS”).
Rated power being equal, products with the Multi-fire system can evenly distribute heat throughout the rooms to be heated.
English
15
H07024510 / DT2000575 - Rev. 00
DT2010172-00
1.8 METHOD OF HEAT DIFFUSION
Diffusion with the Multifuoco System
®
An original Piazzetta system designed to distribute heat evenly throughout the environment, even for several rooms on different f
loors.
The Multifuoco System
®
is very simple to install. It is necessary to install the ventilation kit, following the instructions given with the same, before positioning the stove and installing the surround. A
fter having installed the ventilation kit, it is necessary to connect the warm air outlets to the fan using 75mm diameter hoses. The warm air outflow may be sent in a maximum of four directions using two “Y-elements”. It is advisable to install closable warm air outlets and only one of these may be installed at a distance of less than six metres from the stove, keeping the remaining outlets closed so that distribution may be adjusted as required.
With the Multifuoco System
®
the KNOCKOUTS on the rear of the stove must NOT BE REMOVED, otherwise the apertures must be covered over with a metal plate sealed with silicone resistant to high temperatures and fixed with self-drilling screws. (Figure 16 - 17)
Under no circumstances must collars and any knockouts on the upper part of the stove (see figure 14) be obstructed in order to allow proper operation of the Multifuoco System®and the regular outflow of the warm air that stratifies inside the internal hood and comes out the hood grilles. For the size of the hood grille, see the “TECHNICAL DATA” paragraph under “Minimum section of duct for convective air with open inlet and outlet”.
The warm air ducts must be in non-flammable, resilient and if possible smooth material. To decrease heat loss the pipes must be suitably lagged with insulating material.
For best installation of the Multifuoco System®, Piazzetta supplies as optionals: Inlet/Outlet with closure; Wall Inlet/Outlet with closure; Suction Inlet/Outlet with fan; Hose; Y element; Connecting bend; Hose clamp. See the area dealer for other available accessories.
Diffusion by natural convection
For the stove to work by natural convection the knockouts on the rear (Figure 16 - 17) must be opened during installation in order to allow the warm air to flow upwards and out. There must be apertures or grilles located underneath the grate (see figure 15) with “Minimum section of duct for convective air with open inlet and outlet” that cannot be closed and are at least the size indicated in the “TECHNICAL DATA” paragraph. A passage for air must be made in the top part of the surround so that the heat may flow out from the internal hood through the hood grilles. For the hood grille size, see the “TECHNICAL DATA” paragraph. The air may be ducted in this mode to adjacent rooms.
CEILING
Fig. 14
D
T2030263-00
Fig. 15
DT2030264-00
English
16
H07024510 / DT2000575 - Rev. 00
F
ig. 16
KNOCKOUTS
(DO NOT KNOCKOUT
IF USING MULTIFUOCO
SYSTEM)
D
T2030523-00
Fig. 17
KNOCKOUTS
(DO NOT KNOCKOUT
IF USING MULTIFUOCO
SYSTEM)
DT2030524-00
Fig. 18
DT2030172-00
Use the rear collars on the stove for warm air ductwork and leave the front ones for normal outflow by natural convection towards the hood grille. If all the collars are to be used for air d
uctwork, a hood grille must be installed in any case for the
normal outflow of stratified warm air.
Warm air outlet grille heat radiation area
A safety area must be ensured around the warm air outlet grille, within which there must be no flammable objects (furniture, carpets, curtains...). The safety area includes 600mm from the outer edge of the grille. Figure 18
DT2010173-01
1.9 SUITABLE HEAT INSULATING MATERIALS
Type of suitable heat insulating materials. Material: mineral fibre; ceramic fibre; rock wool. Form: sheets; mat; shells. Specifications: specific weight of at least 245 kg/m³ with working temperature limit of at least 1000°C.
Thermal conductivity λ (400°C) 0.1 W/mK
Thickness: as shown in the figures in the paragraph “MINIMUM SAFETY DISTANCES”.
If the insulating material is not lining the walls, it must be fixed all over the surface of the walls with anchorage points every 30cm.
Material coded “AGI Q132” or “DIN 18895” is allowed for heat insulation.
AIR OUTLET GRILLE HEAT
English
17
H07024510 / DT2000575 - Rev. 00
DT2011906-00
1.10 MINIMUM SAFETY DISTANCES
Ceiling
Floor
Danger area for radiation
- FLAMMABLE WALLS: the stove may be installed near flammable
w
alls provided suitable protection consisting of insulating and non­combustible material is inserted. To insulate the stove and to install the surround correctly, construct a lining wall in non-flammable material (e.g. fireresistant plasterboard or masterboard) and insert a “C” thick layer of i
nsulating material between the two walls. Always leave a gap “A” between the stove and the lining wall. (Fig. 19 - 20)
- NON-FLAMMABLE WALLS: always leave a gap of 5 cm between the stove and the lining wall.
- FLAMMABLE CEILING: create an 8 cm false ceiling of non­flammable material. The minimum distance between the false ceiling and connection to the flueway must be 20 cm, while the flue connection must be insulated with at least 3 cm thick non-flammable material that is resistant to high temperatures. (Fig. 19 - 20) If the surround canopy and the flue connection are metal, the minimum distance from the false ceiling may be reduced to 10 cm, but the insulation of the connection to the flueway must be at least 6 cm thick.
- NON-FLAMMABLE CEILING: the minimum distance between the ceiling and connection to the flueway must be 20 cm.
If the floor is made of flammable material, it must be protected with a layer of insulating material of thickness “E” while an air space “D” must be left between the firebox and the floor. (Fig. 19)
For insulation, use insulating material with the characteristics given in the paragraph “SUITABLE HEAT INSULATING MATERIALS”.
There is a radiation area in front of the stove which must be kept free of any flammable element, such as: carpets, curtains, wood furnishings, ornaments, flammable liquids, fire-lighting products or firewood, etc. This area is defined by the distance “R”. (Fig. 19 - 20)
Failure to comply with the above could cause a fire!!!
The minimum safety distances to be observed are given in the table below:
A C
B E D
Flammable w
all
Insulating material
Flammable floor
R
8 cm20 cm min.
Fig. 19
D
T2032811-00
A
C
R
Flammable wall
Insulating material
Fig. 20
DT2032812-00
MODELS
600-610-650-655 HT
A clearance from stove to flammable wall at the side cm 5
B clearance from stove to flammable wall at the rear cm 5
C thickness of insulating material for wall to side/rear cm 10
D clearance from stove to flammable floor cm See feet height (pg. 22-24)
E thickness of floor insulating material cm 6
R minimum clearance from stove front to flammable material cm 100
Walls
English
18
H07024510 / DT2000575 - Rev. 00
DT2011907-00
1.11 CONNECTION TO THE FLUEWAY
Connection to the flueway must be done using pipes as short as possible without narrowing or restrictions and with a maximum slope of 45° from the vertical..
Flexible metal or asbestos-cement pipes must not be used
Pipes and bends or elbows must be made in compliance with current r
egulations
WARNINGS WITH REGARD TO FLAMMABLE WALLS OR CEILING:
If the connection has to go through elements or walls in heat­sensitive flammable materials, create a layer of at least 20 cm insulation around the pipe. (Fig. 21)
After having drilled a hole in the wall to insert the pipe through into the flueway, the air gaps must be filled with non-flammable, resilient materials with a reduced capacity of heat transmission (e.g. lightweight concrete). Fig. 22
Check that the connection to the flueway is gas/smoke-tight, since the appliance operates in a vacuum.
It is recommended that the connector pipes be insulated with insulating material having the characteristics given in the paragraph “SUITABLE HEAT INSULATING MATERIALS”.
Check that the pipe does not penetrate too far into the flueway, thereby choking the pipe for the passage of smoke and combustion gases.
45°
FLUE
20
20
Insulation
Wall to be protected
Insulation
Maximum
Fig. 21
D
T2030269-01
FLUE
Air gaps
Wall connection flange
F
ig. 22
DT2030270-00
DT2011913-00
1.12 LINING WALL
The surround or the lining wall of the firebox must be self-supporting regardless of the materials with which it is made and under no circumstances must it come into contact with the firebox. Furthermore, the surround must be made with non-flammable materials in compliance with regulations. For Gruppo Piazzetta S.p.A. surrounds, follow the instructions enclosed with the product.
Testing and lighting for first time
Only a visual inspection can be made in the intermediate stage for fireboxes, stoves and appliances that must be assembled or clad with brickwork or require the use of cement binders. In this case operation of the whole installation must be tested after all the building works directly connected with the “LIGHTING FOR THE FIRST TIME” test have been completed, following the instructions given in the booklet.
English
19
H07024510 / DT2000575 - Rev. 00
DT2010177-00
1.13 HOOD GRILLE
The hood grille has the function of allowing air to pass from inside the hood to the environment or vice versa if the Multifuoco system is installed. W
arm air comes out of the hood grille with the natural convection system and it is therefore necessary to maintain the safety distances from flammable materials such as: flammable ceilings or walls, ledges/beams, furniture, curtains, etc.. The hood grille must be installed at least 50cm from the ceiling and with at least 30cm safety d
istance to the sides.
For the hood grille size, see the “TECHNICAL DATA” paragraph.
A non-closable hood grille must be installed without connecting it to the stove so that the warm air that has stratified inside the lining wall can flow out.
With a ceiling over 3 metres high, a NON-CLOSABLE hood grille must be installed on the hood lining at a height of 30cm from the ceiling to allow the stratified air to flow out.
MIN. 30 CM MIN. 30 CM
MIN. 30 CM
FLAMMABLE MATERIALS
FLAMMABLE MATERIALS
CEILING IN FLAMMABLE MATERIAL
Fig. 23
D
T2030271-00
D
T2010178-00
1.14 WOOD MANTEL PROTECTION
Wooden finishes, e.g. wood mantels, may be mounted on the surround. Wood mantels must be:
- installed outside the heat radiation area;
- self-supporting;
- installed with 1cm air gap from the surround or from the heating
part (Fig. 24).
The expansion joint is in ceramic fibre, which has the function of insulating the surround from the metal structure of the stove.
1 cm
Firebox
Hood or surround
1
cm
Surround
Expansion joint
Load-bearing axis
Wood
mantel
Fig. 24
DT2030272-00
1.1 NORMATIVE DI RIFERIMENTO
DT2010027-02
1.16 PREVENTION OF DOMESTIC FIRES
The product must be installed and used in compliance with the manufacturer’s instructions and European and national standards as well as local regulations.
when a flue pipe passes through a wall or a ceiling, special installation methods must be applied (protection, thermal insulation, distances from heat-sensitive materials, etc.) See the paragraph “CONNECTION TO THE FLUEWAY”
- It is also recommended that all elements made of combustible or inflammable material, such as beams, wooden furniture, curtaining,
flammable liquids, etc. be kept outside the heat radiation range of the stove and at a distance of at least 1m from the heating block.
- For other information, see the paragraph “MINIMUM SAFETY DISTANCES” and “CONNECTION TO THE FLUEWAY”.
- The flue pipe, chimney stack, chimney and fresh air intake must always be free of obstructions, clean and checked periodically, that is, at
least twice during the seasonal period from the lighting of the stove and during its use. When the stove has not been used for some time it is advisable to carry out the checks mentioned above. For further information, consult a chimneysweep.
- Only use recommended fuels (See paragraph “FUEL”).
- Ensure compliance with building regulations document J.
1.1 NORMATIVE DI RIFERIMENTO
DT2010179-01
1.15 ELECTRIC POWER SUPPLY
Make sure there is a power socket 230V 50Hz in the rear stove wall ready for installing the ventilation kit and a switch on the outside of the cladding to be able to cut off the power supply during maintenance or when the appliance is not being used. The installation must be earthed and fitted with a circuit breaker in accordance with current wiring regulations. The installation of any electrical services during the installation of this appliance must be carried out by a registered competent electrician and in accordance with the requirements of the latest issue of BS 7671.
When connected ensure that the power cable does not come into contact with hot parts.
English
20
H07024510 / DT2000575 - Rev. 00
1.1 NORMATIVE DI RIFERIMENTO
2.0 TECHNICAL DATA AND SPECIFICATION
DT2010627-00
DT2010626-00
2.1 DESCRIPTION OF THE APPLIANCE
The firebox is an excellent solution because of its core. The firebox is made entirely in thick gauge steel. It comes ready for use without needing any laborious assembly work. It ensures high heating efficiency, reduced consumption and safe use. H
eat is diffused by: radiation, conduction, natural convection or forced convection with application of the Multifuoco System, which is an exclusive ventilation system for quickly and evenly distributing heat at floor level that has been created by the Piazzetta R&D Department. All the firebox are fitted with a metal hood that wraps around and covers the firebox canopy and allows a greater recovery of heated air. By connecting hoses to the holes on the metal hood, heated air may be distributed by natural convection also to adjacent rooms. With the Multifuoco System, the air is taken up from the grille located on the canopy backplate, it enters the metal hood and upon passing t
hrough special gaps is distributed by forced convection through the outlets located in the lower part of the cladding or distributed to adjacent
rooms through relative ducts. (See paragraph “METHODS OF HEAT DIFFUSION”).
No. Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Qty.
1 Aluker
®
front side panel . . . . . . . . . . . . . . . . . . . . . . . . .2
2 Aluker®rear back panel . . . . . . . . . . . . . . . . . . . . . . . . .2
3 Aluker®back panel . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
4 Grate grid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
5 Ash drawer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
6 Fireguard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
7 Grate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
8 Lower smoke baffle plate 688x345 600 HT . . . . . . . . . .1
Lower smoke baffle plate 760x370 610 HT . . . . . . . . . .1
9 Upper smoke baffle plate 685x200 600 HT . . . . . . . . . .1
Upper smoke baffle plate 776x240 610 HT . . . . . . . . . .1
No. Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Qty.
1 Aluker®side panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2 Aluker®back panel . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3 Air diffuser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
4 Grate grid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
5 Ash drawer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
6 Fireguard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
7 Grate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
8 Lower Smoke baffle plate 494x210 . . . . . . . . . . . . . . . .1
9 Upper Smoke baffle plate 467x207 . . . . . . . . . . . . . . . .1
600 HT - 610 HT
D
T2030274-02
650 HT - 655E HT - 655T HT
DT2030512-02
Spare Parts can be obtained from Robeys Limited. Contact details are on page 1 of the instructions.
English
21
H07024510 / DT2000575 - Rev. 00
DT2010183-00
2.2 ACCESSORIES AND EQUIPMENT
D
T2010181-00
2.3 FEATURES
Fuel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .wood (see “FUEL“ paragraph)
Firebox . . . . . . . . . . . . . . . . . . . . . . . . . . .painted steel
Hearth . . . . . . . . . . . . . . . . . . . . . . . . . . . .Aluker
®
Grate and grid . . . . . . . . . . . . . . . . . . . . . .cast iron
Fireguard . . . . . . . . . . . . . . . . . . . . . . . . . .removable
Ash tray . . . . . . . . . . . . . . . . . . . . . . . . . . .removable
Door . . . . . . . . . . . . . . . . . . . . . . . . . . . . .automatic rise n’fall door with ceramic glass heat-resistant up to 750°C
Smoke outlet . . . . . . . . . . . . . . . . . . . . . . .top
Hood shell . . . . . . . . . . . . . . . . . . . . . . . . .aluminised steel
DT2011543-00
2.4 PRODUCT IDENTIFICATION DATA
Every product is identified by a rating plate showing the model and the performance of the appliance as well as a plate giving the serial number. Both plates are located on the bottom shield below the ash drawer. A label bearing the serial number is also applied on the cover last page of the “Installation, operation and maintenance” booklet. Always give the information shown on these plates to the dealer or the Service Centre when requesting service or spare parts.
Product name
Serial number
F
ig. 25
DT2030944-00
PRODUCTION IDENTIFICATION AND RATING PLATE
Fig. 26
DT2030945-00
Description Accessories
Silicone paint spray can In kit Valve with smoke damper control In kit H
ood grille 145x390
I
n kit Air intake grille 175x325 In kit H
exagonal door handle tool
I
n kit Pipes and bends for connection to flueway Optional Accessories for hot air ductwork Optional Multifuoco System®ventilation kit Optional
English
22
H07024510 / DT2000575 - Rev. 00
DT2010327-02
2.5 TECHNICAL DATA
DT2010628-00
2.6 FIREBOX DIMENSIONS
These data are obtained using beech wood with moisture content below 20% and with intervals between stoking-up of approximately one hour. Appliance for intermittent use.
Technical data with closed grate for flue calculations
The above values correspond approximately to a flue with section Ø 25 cm up to 4.5 m in height and Ø 20 over 4.5 m. For model 610 HT: Ø 30 cm up to 4.5 m in height and Ø 25 over 4.5 m.
U.M. 600 HT 610 HT 650 HT 655T HT 655E HT
Rated heat output
kW 10 12.5 8 8 8
Consumption at rated heat output
kg/h 3.55 4.05 2.94 2.94 2.94
Thermal efficiency
% 74 75 72.5 72.5 72.5
CO content (with 13% O2)
% 0.18 0.17 0.18 0.18 0.18
Approved in accordance with standard
- EN 13229 EN 13229 EN 13229 EN 13229 EN 13229
T
est report No.
- C
S-06-081
C
S-07-056
C
S-06-080
C
S-06-080
C
S-06-080
Flue diameter
cm 20 25 20 20 20
Hearth opening (WxH)
cm 68x43 77x47 48x31 48x31 48x31
Grate surface area
cm
2
1900 2550 1100 1100 1100
Weight
kg 190 200 190 190 190
S
ize of packaging (WxDxH)
c
m 88x62x176 97x65x183 72x50x186 72x65x186 72x65x186
Fresh air intake (recommended minimum section)
cm
2
200 300 200 200 200
Combustion air flow rate with open intake
m3/h 93 - 93 93 93
Convective air inlet/outlet (recommended minimum section)
cm
2
350/350 350/350 350/350 350/350 350/350
U.M. 600 HT 610 HT 650 HT 655T HT 655E HT
Rated heat output
kW 10 12.5 8 8 8
Smoke flow rate
g/s 13.72 13.3 11.24 11.24 11.24
Average temp. of smoke in the flue
°C 290 304 280 280 280
Minimum draught
Pa 12 10 12 12 12
20Ø
27 28
10
65
51
164
44
45
55
70
35
20
84
21
38
DT1020235-01
Measurements in cm.
Model 600 HT
English
23
H07024510 / DT2000575 - Rev. 00
20Ø
19,5 23,5
53
48
35
43
55 67
25
75
63
173
10
18
DT1020261-01
Measurements in cm.
Model 650 HT
65
25Ø
29 30
11
67
55
38
171
59
49
79 93
45
14
21
DT1020260-01
Measurements in cm.
Model 610 HT
English
24
H07024510 / DT2000575 - Rev. 00
43 10
19,5 23,5 11,5
20Ø
10
68
70
25
173
48
43
55
R41
35
67
18
53
54,5
DT1020263-01
Measurements in cm.
Model 655T HT
19,5 23,5 11,520Ø
10
68
70
25
173
43 10
48
43
55 67
54,5
35
18
53
DT1020262-01
Measurements in cm.
Model 655E HT
English
25
H07024510 / DT2000575 - Rev. 00
3.0 PREPARATION FOR INSTALLING
DT2010326-00
- Carefully read all the information contained in the section “GENERAL RULES” before installing the firebox.
- Unpack the firebox.
- Release the counterweight by slackening the relative screw to be found inside the upper part of the door (Fig. 27 and 28).
- Release the grate by unscrewing the wing nut (Fig. 29), remove the wood shims and the metal section to be found under the grate and then replace the grate.
- Where present, remove the polystyrene parts fixing the two smoke baffle plates to the inside of the firebox.
- Fit the “Multifuoco System®” ventilation kit, if required, following the sequence given in the respective instructions and refer to the paragraph “METHODS OF HEAT DIFFUSION”.
- Adjust the height of the grate, adjusting the feet of the hearth in relation to the chosen surround and making the hearth level. The firebox is provided with feet allowing the height of the grate to be raised 25 cm above the ground (Fig. 30). If this height needs to be increased, insert suitable shims.
- Fit the smoke damper (see “INSTALLATION OF SMOKE DAMPER”).
- Connect the firebox to the flue as indicated in “CONNECTION TO THE FLUE”.
- Light for the first time and check that the firebox is working properly (see “LIGHTING FOR THE FIRST TIME”).
- If the check is successful, proceed with installation of the surround.
Fig. 27
D
T2030516-00
Fig. 28
D
T2030517-00
Fig. 29
DT2030518-00
25 cm
Fig. 30
DT2030519-00
English
26
H07024510 / DT2000575 - Rev. 00
4.0 INSTALLATION OF THE SMOKE DAMPER
DT2010328-00
The hearth is provided with a smoke damper with articulated rod which aligns with the angle of inclination to which the damper is being set. For installation purposes proceed as follows:
- Position the damper [2] in its seat and keep it in a vertical position.
- Insert the rod [1] fully into the damper [2]. During this operation, the tongue [3] remains facing downwards. (Fig. 31)
- Proceed with the installation of the smoke outlet pipe and its c
onnection to the flue as indicated in the section with the same
name.
- Construct or finish the preparation of the lining and of the facing wall.
- Insert the wooden plug provided into the box [4] and thread it onto the rod [1].
- Then determine the exact position of the box which must follow the angle of the facing wall. By moving the box with the plug, the rod [1] remains as a guide and it will thus be possible to determine the ideal position of the box, rod and facing wall.
- Cut off the rod [1] at 1 cm inside the outer face of the wall.
- Thread on the plate [5] and screw it to the box [4].
- Fit the handle [6], ensuring that the position of the damper corresponds to that of the plate.
If the facing wall is of fire resistant plasterboard (Fig. 33), the box [4] is secured to the wall by screwing on the plate [5] after turning up the side edges.
Fig. 31
DT2030520-00
Fig. 32
D
T2030521-00
PART. “A”
WALL OF PLASTERBOARD
RISES
1 CM
1 CM
PART. “A”
WALL OF PLASTERBOARD
Fig. 33
DT2030522-00
English
27
H07024510 / DT2000575 - Rev. 00
* Approximate values.
It is a good rule to purchase timber during the summer (June-July), since woods are cut down mostly in the autumn and you can therefore be sure that the timber has already been seasoned for approximately 1 year. Firewood can be classified in two qualities: “good” and “mediocre or poor". This classification is according to the heat yield of the wood, the longest flame time it provides, its composition and density.
Good fuels
- Recommended timber comes from the family of broadleaf hardwoods: beech, hornbeam, oak, false acacia, ash, birch, maple, elm.
- All low-resin and close-grained woods (that is hard and heavy timber) are most suitable, since they provide the stove with a steady, continuous flame.
Mediocre or poor fuels
- Timber that is not recommended comes from the family of conifers, willow, poplar and alder. These light soft woods are resinous and therefore create more soot, few embers and incandescent sparks, while requiring more frequent cleaning of the flue and the firebox.
- Another characteristic of softwood is that it gives a lively but short­lived flame and the consumption is higher for the same heat output.
Unsuitable fuels
- Never use wet wood, tarred wood or pellets.
- It is also best not to use: refuse (rubbish), waste paper; paper briquettes; plywood or chipboard; fibreboard; packaging materials; painted wood or wood coated with synthetic material, plastic laminates, cardboard or milk cartons.
Under no circumstances use liquid fuel of any kind whatsoever.
All these materials or similar ones could be hazardous for the user, damage the firebox, the flue connection and the flue, and, last but not least, pollute the environment.
5.0 USE
DT2010329-00
D
T2010043-00
5.1 FUEL
Use well-seasoned and dry wood with less than 20% moisture content. Wood that is ready to burn must have been dried in the open air sheltered from rain or snow for at least 2 years after having been cut. The lower the moisture content of the wood the higher its heating power. Freshly cut wood has 50% less heat value than dry wood. Burning wood that is too wet means wasting most of the calories for evaporation of the water contained in it and, in particular, the walls of the combustion chamber and the flue become fouled and encrusted thereby affecting efficiency. The table below shows how the heating power decreases as the moisture content increases.
Certain basic facts can be all-important for best performance and getting the most out of your appliance. Please find below some basic information intended to be of use with regard to the choice of firewood, the adjustment of the dampers and proper operation of the appliance. During operation, some parts of the appliance (door, handle, dampers, surround) can reach high temperatures. Therefore exercise great c
are and take all necessary precautions. When you need to add wood to the firebox or to adjust the air flow, use the glove or the hand protector provided. If the door of the product fails to close automatically, operation with the firebox open will only be possible with constant checking of the flame.
D
T2010055-02
0
0,5
1,0
1,5
2,0
2,5
3,0
Heating Power (KW h/dm
3
w=20%)
SP
RUCE
SI
L
V
E
R
F
IR
W
I
LLOW
ALDER
P
OP
L
AR
P
INE
LAR
CH
BI
RCH
BE
ECH
ASH
OAK
LOCU
ST
W
HI
T
E BE
ECH
Approximate value referred to ONE cubic decimetre of evenly shaped pieces of wood with approx. 20% moisture content.
DT2010053-00
Moisture content (W) Seasoning time
HEATING POWER OF THE WOOD (Beech)*
kWh/kg Kcal/kg kWh/dm
3
20 after 2 years 4 3400 2.9 30 after 1 year 3.4 2900 2.8 40 after 6 months 2.8 2410 2.7
English
28
H07024510 / DT2000575 - Rev. 00
Log size
The size of the wood logs can also affect the efficiency of the product. It is essential for the wood to be arranged on the grate on top of a l
ayer of embers. The logs must not touch the aluker or the glass window nor must they be put on top of each other. Place the wood as shown in the figure 34. We therefore recommend using logs of the following size:
-
perimeter approx. 30/35 cm;
- lwength approx. 20–25–30 cm according to the type of hearth.
Under no circumstances use liquid fuel of any kind whatsoever. All these materials or similar ones could be hazardous for the user, damage the firebox, the flue connection and the flue, and, last but not least, pollute the environment
P
erimeter
L
e
ng
h
t
Fig. 34
DT20300063-00
DT2011210-00
5.2 SMOKE DAMPER REGULATION
(*) Position referred to a draught of 12 Pa
When lighting the firebox, put the damper to the open “APERTO” position until a bed of embers has been formed. Once the firebox is properly lit, put the damper to the operating position, which may vary according to the atmospheric conditions, the type of flue and consequently the draught. You will learn by trial and error which is the best position for the smoke damper.
Before putting in any logs, always set the damper to the open “APERTO” position. After having put in the wood, set the damper back to the functioning position.
A C
B
Fig. 35
DT2030515-02
SMOKE DAMPER POSITION
FIREBOX IN OPERATION AT NOMINAL POWER LIGHTING OR STOKING-UP OF FIREBOX
600 HT CLOSED ()* OPEN 610 HT CLOSED ()* OPEN 650 HT OPEN (*) OPEN 655T HT - 655E HT OPEN (*) OPEN
Damper positions: closed (A), 1/2 open (B), open (C).
English
29
H07024510 / DT2000575 - Rev. 00
D
T2010333-00
5
.3 COMBUSTION AIR REGULATION
The rated thermal efficiency is determined with the air damper. Pay attention to the positions given in the table below according to the fuels being used. T
he positions given below refer to rated efficiency. Since efficiency also depends on atmospheric and climatic conditions and therefore on the draught, the most suitable position will be found with experience. Regulation is carried out as shown in figure. R
eference should also be made to the paragraph “SMOKE DAMPER
REGULATION”.
Regulation and quantity of material to be burned for rated power:
DT2010045-03
5.4 LIGHTING FOR THE FIRST TIME
Before lighting, remove the supplied accessories (see “ACCESSORIES AND EQUIPMENT” paragraph) and flammable elements from the grate or from the ash drawer and remove any elements of carriage used to protect any part of the stove. If provided in the kit, it is very important to remove the paint spray can, which could explode.
There are two important stages when lighting the appliance for the first time: the operating test and start-up.
1. Operating test
- Before carrying out the operating test, check that everything has been installed correctly (see section “GENERAL RULES”).
- Start with the lighting stage (see paragraph “LIGHTING”).
- The first load should be reduced by 50% of the normal recommended amount.
Should smoke come out:
• do not open the door of the stove;
• close the combustion air dampers (MINIMUM position) only on appliances with combustion air damper;
• let the fire go out slowly;
• open all doors and windows to ventilate the room;
• do not remain in the room or re-enter until you are sure it is safe to do so;
• check the cause of malfunctioning.
Do not extinguish the fire with water as this could damage the grate
2. Start-up
- During this first time of operation it is recommended to use the appliance at minimum capacity, stoking the grate for at least the first day with only 50% of the logs usually indicated as normal.
- Keep the air dampers in the operating position (except for lighting), see paragraph “COMBUSTION AIR REGULATION”.
- This stage allows all the parts to settle down and fumes caused by paints/varnishes, greases or oily liquids used in manufacture to disappear.
- Air the room well in this initial stage.
- This procedure must be carried out with the forced ventilation system turned off.
After this, the appliance will no longer emit odours due to paint evaporation and must only be stoked up with the indicated nominal amounts.
C
LO
S
E
D
O
P
E
N
Fig. 36
DT2030526-00
Data obtained in a laboratory qualified to issue certification.
Should the flue have a strong draught exceding 12 [Pa], the smoke damper must be moved towards the closed “CHIUSO” position.
An excessive increase in fuel and excessive opening of the air/smoke dampers, compared to the values given in the table, leads to an increase in appliance heat, decrease in efficiency and an increase in wood consumption.
600 HT 610 HT 650 HT 655T HT 655E HT
Material to be burned See “FUEL” paragraph
Air damper position Not fitted OPEN OPEN OPEN OPEN
Smoke damper position CLOSED CLOSED OPEN OPEN OPEN
Maximum quantity of fuel to be burned See “TECHNICAL DATA” paragraph
English
30
H07024510 / DT2000575 - Rev. 00
When lighting the fire, the grate should be brought quickly to working temperature. If it is done slowly, condensation will inevitably form and cause blackening of the grate and the glass
Put the fuel into the grate according to the methods described below:
- Put the air or smoke damper to the open position (MAXIMUM) (see paragraphs “COMBUSTION AIR REGULATION” or “SMOKE
D
AMPER REGULATION”). Fig. 37 Fig. 38
- Place the material for kindling (paper, firelighter, etc.) in the centre
of the grate and add small pieces of soft wood (fir) in the form of a pyramid. To light the soft wood quickly, open the door by approx. two centimetres for 5–10 minutes. Figure 38
- Once the bed of embers has been created, stoke-up with the recommended amounts of fuel. Keep the door closed except when adding more fuel and adjust the combustion air or the smoke damper as instructed in the respective paragraphs “COMBUSTION AIR REGULATION” orSMOKE DAMPER REGULATION”.
DT2010047-00
5.7 NIGHT TIME OPERATION AT MINIMUM
After normal operation during the day, the appliance may continue to operate for a few hours at night. When stoking up the fire for the last time in the evening, ensure that the bed of embers is sufficient, put the wood in the grate and then set the combustion air dampers to minimum. Night time operation of the stove at minimum depends on the type of wood (a very hard wood is recommended), the flue draught and the weather. The amount of wood to put on and the necessary adjustment of combustion air flow will be learned with experience (see the paragraph “COMBUSTION AIR REGULATION”). The next morning, start up the fire at maximum to burn off any creosote formed during the night. Creosote deposits start to form when the flue temperature falls to below 150 °C. To prevent this from happening it is important to try to maintain the grate of the appliance at normal working temperature (rated heating efficiency phase) as long as possible.
Prolonged operation of the stove at minimum could require more frequent cleaning of the grate and the flue.
Fig. 37
DT2030064-00
Fig. 38
DT2030065-00
DT2010330-00
5.5 LIGHTING
D
T2010046-00
5.6 OPENING THE DOOR
The door must remain closed while the stove is alight, otherwise it could damage the inside of the stove. The door must be opened slowly, holding it slightly ajar for a moment before opening it completely. Open the door when the flame has died down and certainly never when the flame is very intense.
Always use the hexagonal door handle tool provided.
Do not slam the door shut otherwise the glass could break.
E06030230
Hexagonal door handle tool
F
ig. 39
DT2031080-00
English
31
H07024510 / DT2000575 - Rev. 00
DT2010048-00
5.8 OPERATION UNDER ADVERSE WEATHER CONDITIONS
During the intermediate seasons with adverse weather conditions or when outdoor temperatures are higher, a sudden rise can cause malfunctioning of the draught, thereby impeding proper smoke discharge. In this case the grate must be loaded with only a little wood and the primary air damper be set fully open so that the wood burns faster and thereby stabilises the draught.
D
T2010051-00
5.9 OVERHEATING AND EXTINGUISHING
In the event of overheating or if some appliance parts or the flue turn red:
- immediately stop the supply of fuel;
-
do not open the stove door;
- close the air dampers (MINIMUM position);
The fire will go out due to lack of air.
When the appliance has cooled down, find the cause of the problem and if necessary call in specialised personnel.
In the event of fire, extinguish with a fire extinguisher.
Do not extinguish the fire with water.
Air the room well before using it again in order to get rid of any smoke and combustion gases.
English
32
H07024510 / DT2000575 - Rev. 00
6.0 MAINTENANCE
DT2010111-02
D
T2010058-00
6.1 PERIODIC CHECKS
Check for any formation of creosote in the pipes connecting to the flue and inside the flue during the seasons when the appliance is in o
peration, inspecting them at least once every two months. The combustion of the wood (especially if moisture content is higher than 30%) produces pitch and other organic vapours that give rise to creosote. The formation of creosote causes fouling, which obstructs the flue and the passage of smoke.
“Creosote” is inflammable and can catch fire, causing serious damage to both the flue and to the structure of the dwelling. Only use recommended fuels (see “FUEL” paragraph). If creosote has accumulated, it must be removed to reduce the risk of fire and to improve heat exchange.
The following must be free from obstruction and inspected at least once every two months:
- the flueways (connection to the flue, flue pipe, chimney stack);
- the fresh air intake;
- the appliance hearth (correct position of the plates, the ash tray, the grate and grid, deflectors, smoke dampers, etc);
- the ventilation system (apertures, air ducts, grilles) if installed. Check that the automatic door closing system and the air dampers are in proper working order.
Maintenance of all the above heating system must be carried out at least once a year before the season when it will be used. We also recommend periodically checking the whole heating system during the period of operation until the time when it will not be used for several months.
D
T2010059-03
6.2 CLEANING THE CERAMIC CLADDING
The ceramic cladding must first be cleaned with a soft dry cloth before using any detergent (even mild detergent). Products are available on the market which are suitable for cleaning ceramics as well as concentrated products for cleaning porcelain. These will remove oil, ink, coffee and wine stains, etc.
Never soak the ceramic cladding or clean it with cold water when it is still hot as the thermal shock could cause it to crack.
DT2010060-00
6.3 CLEANING THE STEEL PARTS
The steel sections of the cladding should be cleaned with a soft, dry cloth before applying any detergents. Afterwards it is recommended that you use a degreasing agent such as acetone or vinegar diluted in water.
DT2010061-03
6.4 CLEANING THE PAINTED METAL PARTS
When cleaning the painted metal parts of the product use a soft cloth moistened with water
Never clean metallic parts using alcohol, solvents, petroleum-based products, acetones or other degreasing or abrasive substances.
In the event of such substances being used the manufacturer will not be responsible for any damage caused. Discolouration of metallic parts may be the result of misuse.
All maintenance work (cleaning, any replacements, etc.) must be carried out when the firebox is shutdown and cold. Do not use materials that could scratch or damage the glass, since scratches could become cracks. Under no circumstances use abrasive substances.
D
T2010057-02
English
33
H07024510 / DT2000575 - Rev. 00
DT2010700-00
6.5 CLEANING THE GLASS (DAILY)
If the appliance is very slow to heat up in the ignition phase due to fuel that isn’t completely dry, this is likely to cause a build-up of tar on the glass. This will eventually burn off when the appliance is operating at full capacity. If the tar is left to build up over a long period it will require more effort to remove. We therefore recommend that the glass be cleaned daily before lighting the stove. T
he glass should be cleaned when cold using ammonia-based degreasing agents and not corrosive substances such as solvents.
Do not use any material that could scratch or spoil the glass, as scratches may develop into cracks or breaks.
Only for the purpose of cleaning the glass, the hinged-type door may b
e opened using the door handle tool provided in the kit. Insert the door handle tool into the relative hole in the door and turn to open
In case of breakage
Every one of our hearths comes with a door fitted with a 4 mm thick pyroceram panel resistant to thermal shock up to 750°C. This can only be broken by heavy impact, such as banging the door too hard. In the event of breakage replace with original Gruppo Piazzetta S.p.A. parts only. Do not operate the appliance if the glass is broked or cracked.
Seal control
Proper tightness of the door seal is essential for optimal product performance. It is therefore recommended that the seals be checked periodically or after a long period of use for signs of wear or damage. If necessary replace them using Gruppo Piazzetta S.p.A. original spare parts.
Fig. 40
D
T2031079-00
D
T2010049-04
6.7 DISPOSAL OF ASHES
Ash from natural (non-treated) wood burned in stoves or open fireboxes is composed mainly of calcium, silicon, potassium and magnesium oxides. The ashes can therefore be used as a fertiliser for plants or in the garden, albeit not exceeding 2.6 kg per 10m2annually.
The ashes should be placed in a metal container with a sealed cover. The sealed container should be placed on a non-combustible surface at a safe distance from combustible materials until the cinders have been completely extinguished.
Only when they have been fully extinguished can the ashes be thrown away with organic waste, assuming that nails or other non­organic material are not present.
D
T2010063-00
6.6 CLEANING THE GRATE AND THE ASH TRAY
The grate and the ash tray must be cleaned daily. Using the grate for a whole day contributes to the accumulation of ash or residual combustion products. If cleaning is not done regularly there will be an excess of residues, which will affect appliance efficiency. The ash tray also needs emptying regularly, because if it fills up and obstructs the grate grid it will cause appliance malfunction.
DT2010064-00
6.8 CLEANING ALUKER
®
The interior of the unit has been constructed from an innovative material called “Aluker”. Aluker is based on substances that are completely non-toxic and is heat-resistant up to 1400°C. In spite of its considerable strength it is not recommended that you throw large pieces of wood forcefully against the bricks. Aluker darkens when the stove is first lit but returns to its natural colour gradually as the bricks warm up. Some advice for optimum use of Aluker bricks:
- Don’t use water to put out the fire - leave the bricks to cool by themselves;
- Don’t scratch Aluker bricks with metal objects; To clean Aluker bricks use an ordinary brush.
34
H07024510 / DT2000575 - Rev. 00
DT2010334-00
6.9 REMOVING THE SMOKE BAFFLE PLATES
The appliance is fitted with two smoke bafle plates, which are designed to lengthen the path of the flue gas or smoke by increasing the heat exchange surface area. The smoke baffle plates rest on s
upports inside the fireboxes, as shown in figure 41-42. Should it be necessary to replace the smoke baffle plates, unscrew the hexagon nut (for the fireboxes 650HT and 655HT only) to be found on the left part of the smoke baffle plates, push the smoke baffle plates upwards, turn them downwards and remove them.
English
Smoke baffle plates supports
View of the smoke baffle plates model 650 HT - 655 HT
Upper smoke
baffle plate
Lower smoke
baffle plate
View of the lower smoke baffle plate from below
Fig. 41
D
T2030530-00
View of the smoke baffle plates model 600 HT - 610 HT
Upper smoke
baffle plate
Lower smoke baffle plate
Fig. 42
D
T2030529-00
D
T2010065-01
6.10 CLEANING THE FAN (ONCE A YEAR)
All cleaning and maintenance operations must be carried out after DISCONNECTION OF THE POWER.
Pursuant to current regulations on the safety of electrical equipment, you must contact a Piazzetta After-Sales Service Centre or a qualified electrician for all and any work connected with installation, maintenance or servicing that involves access to electrical parts.
Dust can accumulate in the ventilation kit and in particular in the holes of the protective cover of the fan, the grilles and the fan blade, which should therefore be cleaned once a year. Use a vacuum cleaner or compressed air, being careful with the electrical parts. The ventilation kit must be disassembled for proper cleaning. Follow the installation procedure in the reverse order (see the instructions enclosed in the kit).
DT2010068-00
6.11 SHUTTING DOWN
Before any long period during which the firebox will be inactive we recommend that you carry out a thorough cleaning, thereby avoiding encrustations and oxidations which will be difficult to clean later. We also recommend that as a preventative measure you carry out a general checkup as outlined in the paragraph headed “PERIODIC CHECKS”.
After a period of inactivity problems relating to the expansion of parts or the release of odorous gases may arise. We therefore recommend that upon restarting the unit you do not immediately run it at full power. Nor should you activate the ventilation system until the odorous gases have dispersed. This problem can be dealt with by simply airing the room.
DT2010379-01
6.12 CLOSING DOOR SYSTEM
This operation should be carried out by specialised personnel.
The “rise n’fall” door closing system must be checked periodically, at least once every two years; attention must be paid in particular to lubricating the roller located inside the double glazing or, depending on the model, the pulleys located outside the double glazing.
English
35
H07024510 / DT2000575 - Rev. 00
Some of the above problems could be resolved by following the instructions. Only qualified persons must carry out work on the stove and only when it is cold and disconnected from the power supply (pull out the plug). Unauthorised tampering with the appliance or use of other than original spare parts invalidates the warranty and relieves the m
anufacturer of all and any liability. The manufacturer shall not be liable for any problems caused by lack of or inefficient maintenance or by failure to comply with the instructions in the product installation and operating guide.
7.0 TROUBLESHOOTING
DT2010069-01
P
roblem Cause Remedy
The window becomes excessively dirty
Lack of draught
Open the smoke damper. Check the smoke/gas discharge pipe
W
et wood
Use dry wood
Use of mediocre or poor class fuels
Change the type of fuel (See “FUEL” paragraph)
Too little combustion air
Open the air dampers more, if installed
Condensation forms
Section of flue too large
Reduce the section by inserting a well insulated pipe with suitable section inside the flue
Flue not adequately insulated
Clad the flue with hollow tiles or other insulating materials
Slow combustion and therefore low smoke temperature
Burn smaller and dry logs. Open the primary air damper more, if installed
Smoke comes out of the firebox in ad­verse weather conditions
Chimney stack has no down-draught cowl
Replace the chimney stack with one that has a down-draught cowl
Flue not suitably insulated
Clad the flue with hollow tiles or other insulating materials
Difficulty in lighting Air or smoke dumper closed
Put the combustion air dampers, if installed, to maximum position and fully open the smoke damper
Logs too large
Use smaller logs
Wood too wet
Burn drier wood
Lack of draught
Open the smoke damper. Check the smoke/gas discharge pipe
English
36
H07024510 / DT2000575 - Rev. 00
Problem Cause Remedy
I
nsufficient heat
Quantity of wood less than necessary for nominal efficiency
Use the quantity of wood indicated i
n the instructions (See “TECHNICAL
DATA” paragraph)
Undersized grate for the environment to be heated
Integrate with another product
Inadequate insulation for the environ­ment in which the firebox is installed
Insulate well with suitable materials
Oversized fresh air intake Decrease the intake section
Too little and only lukewarm air flows from the outlets
P
ipework not insulated
S
uitably insulate
Pipework too long or with too many bends
Change the path, complying with the ventilation kit instruction booklet
Too many branches
Change the path
Environment too large for capacity of the fan and power of the product
Heat fewer rooms or use the stove as a supplementary source of heat
The fan does not work (*) Incorrect connection to power supply
Correct the connection according to the assembly diagram
Electronic regulator damaged Replace the regulator
Power failure Power the appliance
Noisy fan (*) Presence of dust or similar in the fan Clean the fan
Vibrations Check fan position
Worn rotating parts
Replace the fan
Smoke comes out upon opening the door
Door opened too fast
Keep the door just ajar for a few seconds before fully opening
There are still flames
Only open the door when just embers remain in the grate
(*) Pursuant to current regulations on the safety of electrical equipment, you must contact a Piazzetta After-Sales Service Centre or a qualified electrician for all and any work connected with installation, maintenance or servicing that involves access to electrical parts.
COPY
COPY
COPY
UK
www.miotto.it
Gruppo Piazzetta S.p.A. Technical Department - cod. H07024510 / DT2000575 - Rev. 00 - (06/2010)
Via Montello, 22
31011 Casella d’Asolo (TV) - ITALY
Tel. +39.04235271 - Fax +39.042355178
www.piazzetta.it
e-mail: infopiazzetta@piazzetta.it
Product serial number, to be quoted when requesting service from the Gruppo Piazzetta After-Sales Service Centre.